| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.8 CrAccepted-Finance | ₹3.8 Cr | L1 | Accepted-Finance Qualified |
| 2 | L2₹3.9 Cr+₹2.4 L (0.61%)Accepted-Finance | ₹3.9 Cr+₹2.4 L (0.61%) | L2 | Accepted-Finance Qualified |
| 3 | Not Admitted-Fee/PreQual/Technical 09 SAVITRI ENCLAVE NEW HYDERABAD LUCKNOW LUCKNOW UTTAR PRADESH 226007 UDYAM UP 50 0123339 | LUCKNOW | UTTAR PRADESH | 226007 | - | - | Not Admitted-Fee/PreQual/Technical Others-Solvency not attached |
Tender Value
₹3.9 Cr
EMD Value
₹11.6 L
Closing Date
28 May 2026, 12:00 pmClosed
Chief Engineer
Vipin Khand, Gomti Nagar, Lucknow
Pradhikaran karyalaya bhawan New building ke Sevnth evam Eight floor ka renovation evam upgradation ka karya
2026_LDAUP_1149201_1
23/E-Nivida/CE/2026-27(3)
Open Tender
Civil Works
Percentage
180 days
Lucknow
Please refer Tender documents.
3 documents required · 3 mandatory
₹4,366
Secretary LDA
₹11.6 L
17 Jun 2026
18 May 2026
29 May 2026
18 May 2026
28 May 2026
18 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported 15.9 mm all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-1660 | 100 | RMT | 1,300 | ₹1,30,000 |
| 2 | Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported 12.7 mm all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-1202 | 100 | RMT | 1,202 | ₹1,20,200 |
| 3 | Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported 9.5 mm all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-845 | 100 | RMT | 845 | ₹84,500 |
| 4 | Interconnecting refrigerant pipe work with (19mm/13 mm thick) closed cell elastomeric nitrile rubber tubular insulation between each set of indoor & outdoor units as per specifications, all piping inside the room shall be properly supported 6.4 mm all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-650 | 375 | Nos | 650 | ₹2,43,750 |
| 5 | Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 40 mm dia with 6 MM thickness all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-595 | 100 | Rmt | 595 | ₹59,500 |
| 6 | Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 32 mm dia with 6 MM thickness all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-442 | 100 | RMT | 442 | ₹44,200 |
| 7 | Supply, Installation, testing and commissioning of Hard PVC Pipe Suitable for 10 Kg/cm2 water pressure including fittings such as elbow, socket, reducer, etc.insulated with 6 mm thick tubular nitrile insulation, 25 mm dia with 6 MM thickness all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-273 | 100 | RMT | 273 | ₹27,300 |
| 8 | Providing & fixing control cum transmission wiring of copper in suitable conduits between indoor and out door unit all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-371 | 4,500 | rmt | 228 | ₹10,26,000 |
| 9 | Supply & Laying of M S Slotted Angle for pipes and cables horizontaly and vertically along with threaded rod, nut, bolt, saddle, tie etc all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-260 | 100 | RMT | 260 | ₹26,000 |
| 10 | Wall Chaseing as per site requirement all complete as per drawing, specification and direction as approved by Engineer -in-Charge.-180 | 50 | RMT | 180 | ₹9,000 |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 5.76 MB
SBD.pdf
Tender Documents • 3.73 MB
BOQ_2151369.xls
BOQ • 0.46 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .