Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.1 LAccepted-AOC SHOP NO 259 LOHOGAON ROAD KALWAD KHANDVE NAGAR PUNE 411032 | PUNE | MAHARASHTRA | 411032 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹25.2 L+₹26,350 (1.06%)Rejected-Finance | L2 | Rejected-Finance High Rate | |
| 3 | L3₹34.4 L+₹9.5 L (38.3%)Rejected-Finance SHOP NO 11 18 CITY CENTRE 930 931 SYNAGOGUE STREET PUNE 01 | L3 | Rejected-Finance High Rate | |
| 4 | L4₹35.3 L+₹10.4 L (41.9%)Rejected-Finance | L4 | Rejected-Finance High Rate | |
| 5 | L5₹37.3 L+₹12.4 L (49.9%)Rejected-Finance 00 BHUSAR FARM KE PASS K K PURI NANDANPURA JHANSI UTTAR PRADESH 284003 | JHANSI | UTTAR PRADESH | 284003 | L5 | Rejected-Finance High Rate |
| Sl No | Description | Qty | Unit | M/S - SUJIT ELECTRICALS L7 | Suchit constructions L4 | Rama Electricals L1 | Sunhari Electricals L2 | PROLINK COMPUTERS L3 | A K ENTERPRISES L5 | D H L ENTERPRISES L9 | R k construction L6 | RELIABLE ENTERPRISES L8 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/poles etc in soft/loose soil and getting out complete all as specified. | 160 | Cum | 200 ₹32,000 | 162 ₹25,920 | 120 ₹19,200 Lowest | 120 ₹19,200 Lowest | 165 ₹26,400 | 211 ₹33,760 | 190 ₹30,400 | 220 ₹35,200 | 450 ₹72,000 |
| 2.00 | Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm all as specified and directed. | 155 | Cum | 150 ₹23,250 | 45 ₹6,975 | 40 ₹6,200 | 20 ₹3,100 Lowest | 60 ₹9,300 | 111 ₹17,205 | 90 ₹13,950 | 229 ₹35,495 | 100 ₹15,500 |
| 3.00 | Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point for any type of excavation. | 5 | Cum | 175 ₹875 | 63 ₹315 | 40 ₹200 | 20 ₹100 Lowest | 60 ₹300 | 111 ₹555 | 75 ₹375 | 186 ₹930 | 100 ₹500 |
| 4.00Supply and laying DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of following sizes polythylene including coupler and bend with smooth internal and profiled external surfae for non pressure under groundcable complete all as specified | ||||||||||||
| 4.01 | 50mm | 1,000 | RM | 110 ₹1,10,000 | 63 ₹63,000 | 50 ₹50,000 | 45 ₹45,000 Lowest | 81 ₹81,000 | 111 ₹1,11,000 | 78 ₹78,000 | 90 ₹90,000 | 120 ₹1,20,000 |
| 4.02 | 40 mm | 800 | RM | 90 ₹72,000 | 54 ₹43,200 | 40 ₹32,000 | 36 ₹28,800 Lowest | 60 ₹48,000 | 81 ₹64,800 | 75 ₹60,000 | 90 ₹72,000 | 150 ₹1,20,000 |
| 5.00 | M&L for cable cover of size 80mm half round complete all as specified and directed.
Note : two half round (one on top and one on bottom of cable ) shall be measured as one RM length | 100 | RM | 150 ₹15,000 | 360 ₹36,000 | 110 ₹11,000 | 105 ₹10,500 Lowest | 150 ₹15,000 | 211 ₹21,100 | 300 ₹30,000 | 240 ₹24,000 | 150 ₹15,000 |
| 6.00 | M & L for Cutting of road/hard standing and making good with PCC (1:2:4) using 20mm graded stone aggregate complete all as specified. | 7 | Cum | 3,000 ₹21,000 | 3,600 ₹25,200 | 250 ₹1,750 Lowest | 1,800 ₹12,600 | 300 ₹2,100 | 4,011 ₹28,077 | 4,200 ₹29,400 | 2,600 ₹18,200 | 500 ₹3,500 |
| 7.00 | Supply in replacement & Lay in trenches in road cross / floor/pole etc, tube galvanised iron, 40 mm bore Light grade for protection of cable all as directed. | 80 | RM | 650 ₹52,000 | 450 ₹36,000 | 200 ₹16,000 Lowest | 300 ₹24,000 | 330 ₹26,400 | 311 ₹24,880 | 290 ₹23,200 | 980 ₹78,400 | 450 ₹36,000 |
| 8.00 | M&L for PCC 1:4:8, type D2, using 40mm graded stone aggragate for pole foundations, filling and mass concrete all as specified and directed. | 1 | Cum | 3,500 ₹3,500 | 2,700 ₹2,700 | 2,500 ₹2,500 | 2,000 ₹2,000 Lowest | 3,000 ₹3,000 | 2,511 ₹2,511 | 3,200 ₹3,200 | 2,700 ₹2,700 | 7,000 ₹7,000 |
Tender Value
₹40.0 L
EMD Value
₹80,000
Closing Date
30 Jul 2025, 6:00 pmClosed
Garrison Engineer (Central) Pune
Garrison Engineer (Central) Pune, Arjun Marg, Pune-411001
8613 REPAIRS/ REPLACEMENT/ MAINT TO SECURITY LIGHT FITTINGS, POLES, CABLES IN MES INSTALLATIONS AND ALLIED ITEMS AND CERTAIN DG SET IN THE AREA OF OLD NDA WING, ASI, AIPT AND OTHER MINOR UNIT UNDER GE (CENTRAL) PUNE
2025_MES_719349_1
8613 REPAIRS/ REPLACEMENT/ MAINT TO SECURITY LIGHT FITTINGS, POLES, CABLES IN MES INSTALLATIONS AND
Open Tender
Civil Works
Item Rate
270 days
Garrison Engineer (Central) Pune
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Garrison Engineer (Central) Pune
₹80,000
Yes
15 Sept 2025
9 Jul 2025
1 Aug 2025
9 Jul 2025
30 Jul 2025
23 Jul 2025
Amount
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of LT UG cable/poles etc in soft/loose soil and getting out complete all as specified.
Returning, filling in soil, including spreading, leveling watering and well ramming in layers not exceeding 25cm all as specified and directed.
Removing excavated material not exceeding 50m and depositing where directed at a level not exceeding 1.5 m above the starting point for any type of excavation.
Supply and laying DWC (Double Wall corrugated) HDPE pipe ISI marked of outer dia of following sizes polythylene including coupler and bend with smooth internal and profiled external surfae for non pressure under groundcable complete all as specified
M&L for cable cover of size 80mm half round complete all as specified and directed. Note : two half round (one on top and one on bottom of cable ) shall be measured as one RM length
M & L for Cutting of road/hard standing and making good with PCC (1:2:4) using 20mm graded stone aggregate complete all as specified.
Supply in replacement & Lay in trenches in road cross / floor/pole etc, tube galvanised iron, 40 mm bore Light grade for protection of cable all as directed.
M&L for PCC 1:4:8, type D2, using 40mm graded stone aggragate for pole foundations, filling and mass concrete all as specified and directed.
M & L for PCC 1:3:6, type B1, using 20mm graded stone aggregate concrete mass filling, coping for poles etc including necessary form work all as directed.
Supply and fix in replacement cable insulated galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with aluminium conductor for cross sectional area of 6 Sqmm 2 core including connections with lugs all as directed.
Supply, lay / fixing in replacement, commissioning of Cable XLPE insulated Galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of size 10 sqmm 2 core and testing all as directed.
Supply and lay/ fixing in replacement Cable XLPE insulated Galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with aluminium conductor of size 10 sqmm 4 core complete all as directed.
Supply and lay/ fixing in replacement Cable XLPE insulated Galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sqmm 4 core complete all as directed.
Supply and lay/ fixing in replacement Cable XLPE insulated Galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sqmm 4 core complete all as directed.
Taking out existing old corroded pole and Supply & erect in position steel tubular pole complete with MS base plate finial tapper plug cap bolt, nut, screws etc all as specified for swaged pole of type 410 SP 31 , 09 mtrs long including painting with two coats of aluminium paint over a coat of red oxide paint all as directed. NOTE: Excavation, earth work and PCC shall be measured and paid sperately.
Disconnecting and taking down defective street light fittings of any type/ brand from post top lantern pole or street light pole of 11 mtr height / from gate pillars and repairing and refixing after replacing all unserviceable parts including internal wiring all as directed. Note : (1) spares such as nults and bolts shall be included and driver if any shall be measured in item No 18&19 (2) Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
Disconnecting and taking down defective street light fittings of any type/ brand from high mast light pole of any height using electrically operated crane / ladder and repairing and refixing after replacing all unserviceable parts including internal wiring all as directed. Notes for Items from 16 & 17 Cost of Minor items such as screws, nut, bolts, wire for internal wiring will be provided by the contractor without any extra cost to the department. (b) Spare parts required for above item will be measured and paid separately under supply only items Nos 18 to 20 here in after. Labour charges deemed to be included in quoted rates. (c) The street light fitting cover shall be cleaned properly as directed by Engineer-in-charge during repair works and rate for the same is deemed to be included in quoted rates. (d) Necessary tools, ladder, meggar and other testing equipments etc shall be arranged by the contractor at his own cost and no extra payments will be entertain on this acoount. (e) The item will be measured once irrespective of no. of visits but spares will be measured seperately
Supply and fix in repairs electronic driver suitable for LED light fitting 30 to 60 Watt system power all as specified and directed.
Supply only electronic driver suitable for LED flood light fitting 120/150 Watt system power all as specified and directed.
Supply only PVC insulated, PVC sheathed multistranded copper conductor cable of size 3 core 1.5 Sqmm with necessary electrical connections from switch gear to high mast top connector block complete all as specified and directed.
Supply and fixing in repairs/replacement of Security/Street light control panel outdoor type made out of 3.15 mm thick CRCA sheet totally enclosed conforming to relevant IS/IEC, CPRI type tested and suitable bus bar including angle iron frame made out of 40x40x 5 mm angle duly powder coated with 60 cm legs duly grouted with PCC complete all as specified and as directed comprising the following :- (a) MCCB TPN 63 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity adjustable thermal magnetic type ICS=100%ICu as incoming - 01 No (b) MCB TPN 40 Amps, 415 Volts, AC, 50 Hz, 10 KA rupturing capacity as outgoing - 02 Nos (c) Power contactor 3 Pole, AC, 3 rating, 40 Amps coil voltage 240 Volts - 02 Nos (d) Digital timer for controlling the contactor, single phase, 230 Volts AC ( e) MCB SP 06 Amps, 230 Volts, AC, 50 Hz - 03 Nos (f) Switch socket combination multipurpose 2 in 1, 3 pin, 5 and 15 Amp flush type universal complete. 01 Nos (g) Indicator lamps(RYB) - 01 Set (h) Digital multi functional multimeter for showing Volts/Amps/PF etc alongwith suitable rating CT coil - 01 Set (i) Control wiring for automatic operation of street lights with by pass arrangement all as specified and as directed. (j) Incoming and outgoing terminals for suitable cable
M&L for preparing old painted steel surfaces by scrubbing with wire brush and applying two coats of aluminium paint upto 11 mtr long LT steel tubular poles complete with connected fittings such as brackets, cross arms, metal portion etc complete all as directed by Engineer-in-Charge
M&L for earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to and including GI strip of size 32 x 6 mm 7.5 mtr beyond the earth pit as earthing lead including GI protection pipe 40 mm bore (light grade) upto 7.5 mtr beyond the earth pit and connecting to equipments by means of earthing lead , GI bolts, nuts & washer etc with provision of char-coal and salt etc all as per electrical plate No 3 of SSR Part - I, 2009 including RCC cover and MS angle iron frame watering arrangements with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-charge.
M&L for earthing with galvanised steel earth plate electrode 60cm x 60 cm x 6.3 mm burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to depth of not less than 1.5 mtr below ground level connected to and including GI wire of size 4mm, 7.5 mtr beyond the earth pit as earthing lead including GI protection pipe 15 mm bore (light grade) upto 7.5 mtr beyond the earth pit and connecting to equipments by means of earthing lead , GI bolts, nuts & washer etc with provision of char-coal and salt etc all as per electrical plate No 3 of SSR Part - I, 2009 including RCC cover and MS angle iron frame watering arrangements with GI pipe 20 mm dia (medium grade) & MS funnel, concrete pit including excavation and earthwork and testing on completion etc complete all as specified and directed by Engr-in-charge.
Supply and fix in replacement energy efficient LED security light fitting 50 Watt luminaire in pressure die cast housing with class leading IP -65/66,Surge protections for long lasting performance complete including taking down unserviceable fitting complete all as specified and directed. Note: Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
S & F in replacement pole mounting boxes (looping box) factory made out of PVC heavy duty of make Sintex cat No GSJB 2520 or equivalent, ISI marked of size 250 x 200 x 105 comprising of MCB SPN 6 Amps 240 Volts-01 No. complete all as directed. Note:- Fixing clamps shall be made out of M.S Flat Iron 40 x 3 mm thick with nut bolts and Unit rate quoted shall be deemed to be inclusive of the same. Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
S & F in replacement pole mounting boxes (looping box) factory made out of PVC heavy duty of make Sintex or equivalent, ISI marked of size 100 x 100 x 95 comprising of MCB SPN 6 Amps 240 Volts-01 No. complete all as directed. Note:- Fixing clamps shall be made out of M.S Flat Iron 40 x 3 mm thick with nut bolts and Unit rate quoted shall be deemed to be inclusive of the same. Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
S & F in replacement street light mounting bracket made out of GI pipe suitable size mm dia medium grade not less than with 0.5mtr bend as directed with and including pole fitting clamps made out of MS flat of size 40 x 6 mm bolts, nuts and washers (02 sets) all as direced by Engineer-in-charge. Note : Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
Supply in replacement and install in replacement LED Floodlight 150W on high mast pole / roof of height not exc 20 m luminaire with secondary optics made in pressure die cast housing and heat sink in aluminium extrusion with IP65/66. Note : Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
Supply and fix in replacement for Integral decorative LED bollard 9W with opal acrylic with IP65 Protection fixed on PCC foundation, PVC pipe for cable for bollard fixing complete all as directed at site Note: Rate deemed to include excavation , PCC for foundation and electrical connection complete
Supply and fix in replacement Post top for 360° indirect light 40 W LED with electric drivers superflux LEDs, 120-270 V AC inbuilt power supply, complete fixed on existing place all as accessories all as specified. Make : bajaj BGCL 40W LED WH or equivalent Note : Necessary ladder or vehicle arrangement shall be provided by contractor and rate for the same deemed to be included.
Supply and fix in replacement new generation, post top, energy saving, environmental friendly, long life aesthetically designed with symmentrical light distribution spun aluminium landscape luminaire with high power LEDs as light source of cap 40 Watts IP-65 protection including taking down old fittings complete all as specified and directed. Make : Luker LPL 430 40W WW/CW or equivalent
Supply and fix in repairs the following spare parts required for DG set panel/ street light panel as required at site
S&F in repairs RYB indicator lamp complete all as specified and directed
S & F in repairs MCCB 63A, 25kA, FP adjustable thermal magnetic Ics=100% Icu complete all as specified and directed
S & F in repairs MCB FP 63A C series 10 KA complete all as specified and directed
S & F in repairs MCB DP 32A C series 10 KAcomplete all as specified and directed
S & F in repairs Multifunction meter complete all as specified and directed
S & F in repairs Voltmeter 0-500V complete all as specified and directed
S & F in repairs Ammeter 0-500 A complete all as specified and directed.
Maintenance and servicing of DG sets once in a month including attending faults on call basis for normal repairs including replacement of defective & worn out parts by new spares such as filters, gaskets, V-belts, Engine oil, Coolant, rubber hoses, door hinges/ lock, worm drive clamps, nuts, bolts and cleaning of alternator and attending faults of AMF panels etc and greasing of bearings of engine and alternator, checking of batteries, adding distilled water, checking and topup of oil and coolant levels for following ratings as directed by Engineer-in Charge. Note : 1. Spares required for above maintenance will be measured and paid separately under relevant item. 2. Servicing to be carried out as per manufacturer instruction
D. G . Set 180 KVA, Engine make: Greaves, Location : ASI Auditorium
D. G . Set 180 KVA, Engine make: Kirloskar, Location :ASI Adm bldg
D. G. Set 160 KVA, Engine make: Kirloskar, Location : ASI SSF club
D. G . Set 62.5 KVA, Engine make: Greaves, Location : AIPT Offr mess
D. G . Set 62.5 KVA, Engine make: Cummins, Location : AIPT Auditorium Hall
D. G . Set 62.5 KVA, Engine make: Cummins, Location : AIPT Auditorium Hall
D. G . Set 50 KVA, Engine make: Cummins, Location : Old NDA Pump House
D. G . Set 15 KVA, Engine make: Cummins, Location : ASI House
Supply only diesel filter element with O ring, suitable for following capacities of DG sets
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180KVA
Supply only oil filter element with 'O' ring, suitable for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180KVA
Supply only by pass filter element with O ring suitable for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180KVA
Supply only air filter element suitable for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50 KVA
D. G . Set 62.5 KVA
D. G . Set 160/180 KVA
Supply only fan belt suitable for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180 KVA
Supply only belt for battery charging alternator for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180 KVA
Supply only rubber hose pipe set for water/Air circuit complete with clamps, suitable for following capacities of DG sets :-
D. G . Set 15 KVA
D. G . Set 50 KVA/ 62.5 KVA
D. G . Set 160/180 KVA
Supply only engine oil, multi grade 15W / 40.
Supply only Petroleum jelly.
Supply only distilled water for lead acid battery
Supply only for coolent for DG Sets.
M&L for cleaning/removing dirt and impurities particles of diesel tank and replacing damaged parts, nuts and bolts including cleaning and rectifying leakages of diesel for effective function of plant complete all as directed.
S & F in repairs Water temperature gauge including sensor and cable complete all as directed.
Dismantling of radiator from the DG set for overhauling & cleaning descaling with acid , repair of fins, removal of leakage, welding /brazing & refixing it duly repaired complete all as directed by Engineer- in- Charge for the following capacities DG sets.
D. G . Set 15 KVA
D. G . Set 50/ 62.5 KVA
D. G . Set 160/180 KVA
Calibration of FIP and injectors from the authorised dealer including petty repairs to make the FIP functional for the following capacities of DG sets including necessary spares required for smooth functioning of FIP :-
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180 KVA
M&L for repair / overhauling of self starter including replacement of carbon brushes, bearing, bushes, rewinding of armature and field etc. and varnishing complete all as directed for the following capacity :-
12 Volts self starter for DG set of capacity 15 KVA
12 Volts self starter for DG set of capacity 62.5/ 50 KVA
24 Volts self starter for DG set of capacity 160/ 180 KVA
M & L for repairing of 12 V battery charging alternator engine mounted with replacement of any of the unserviceable part such as rectifier with voltage regulator, diode plate, carbon brushes for the 100AH to 150AH capacities complete all as directed
Dismantling the existing unserviceable power contactor 3phase 4 pole of following capacities 415Volt, 50 Hz AC, from the AMF panel after disconnecting incoming and out going connections and all control connections including coil connections, supply and fixing new power contactor 3 phase 4 pole 200 Amps with 2NO+2NC with suitable 415V/220 V coil as required and connecting both incoming and outgoing connections complete all as directed. Note : The contractor shall include the rate for all necessary adjustement of panel items like busbar etc to fit the Power contactor and make it functional
S & F in repairs Time delay relay suitable for 15 KVA to 180 KVA DG Set complete all as directed
M&L for tappet setting of following capacities of DG sets complete all as specified and as directed
D. G . Set 15 KVA
D. G . Set 50/62.5 KVA
D. G . Set 160/180 KVA
Supply and fix in repairs automatic voltage regulator 15 KVA to 180 KVA DG set complete as per existing DG sets all as directed
Supply and fix in repairs voltage monitor regulator 15 KVA to 180 KVA DG set complete as per existing DG sets all as directed
Supply and fix in repairs fuel steel braided pipe with benjo bolts and washers etc of suitable size DG Sets complete all as directed
Supply and fix in repairs control wiring of the DG set up to 180 KVA complete including provision of additional auto cables heavy duty suitable for Gen set application complete all as directed
Supply and fix in repairs lead acid battery 12 Volts 150 Ah with initial charging and having indicators to know the status of level of electrolyte complete all as directed .
M & L for Top Overhauling only of DG set of following capacity of Kirloskar/Cummins/ Greaves and including replacement of gaskets etc complete all as specified and all spare parts required to complete the work to the entire satisfaction of Engineer-in-charge .
D. G . Set 15 to 62.5 KVA
D. G . Set 160/180 KVA
Supply and fix in repairs solenoid valve suitable for following capacity DG sets for smooth functioning of DG sets complete to the satisfaction of Engineer-in-Charge
D. G . Set 15 KVA to 62.5 KVA
D. G . Set 160/180 KVA
Supply and fix in repairs microprocessor based multifunction relay suitable for DG sets operation and showing the various parameters such as Volt, Ampere, frequency, RPM etc complete all as directed
Dismantling the existing unserviceable alternator up to 180 KVA DG set and Transporting the same to authorised service centre removing the short circuited winding wire fully, cleaning the armature slots carefully and rewinding fully with same gauge copper winding wire, insulating with same grade and class insulating material, varnishing drying out setting back the alternator and transporting back in location, fitted to the DG set including connecting up testing and commissioning all as directed.
M&L for Preparation of old painted surfaces of the Canopy/ Frame/ Exhaust Manifold/ Silencer of DG Sets complete degreasing and spray painting the same with two coats of approved synthetic enamel paint of approved shade complete all as directed.
Taking out turbocharger upto 180 KVA DG Set any make model, cleaning/removing dirt and impurities particles of turbo charger impeller and replacing damaged parts, washers, nuts and bolts and including rectifying leakages completely for effective function of DG Set and re-fix in same position and testing complete all as directed.
M & L for dismantling of lub oil tank replacement of the gaskets and refixing at original position including checking and repair to leakages in the engine side, replacement of unserviceable gasket complete all as directed
M & L for earth continuity conductor or main earthing lead fixed to wall as recessed and chasses or burried on ground or drawn in conduit/suitable protection pipe or any indicated situtation for loop earthing as required with 32 mm x 6mm GI flat strip including necessary welding joints/Pipe/GI nuts and bolts etc complete all as directed.
M & L for MS work for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated with including paint including dismantling of old unsviceable MS Framed works complete all as directed.
Supply and fix in replacement new tank against detoriated tank in DG set of 62.5 DG set complete all as specified and directed including necessary connections and removing of old U/.s tank from DG set and inserting new tank with all necessary connections complete all as specified and directed. Note : The quoted rate shall include rate for necessary cable, pipe and all connected items required on ground from tank to DG set complete making the DG functional
Supply and fix in replacement cubical indoor type, weather proof, AMF Control panel fabricated out of 2 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked 2 Nos 4 pole power contactors of 125 Amps rating mounted side-by-side on a base plate for changeover of engine and main supply, 2 Nos of 100 Amps 35 KA, 4 pole MCCB with overload relay range of appropriate rating for incoming mains supply and engine alternator set supply control including static battery charger of suitable rating with auto cut off facility for charging the battery from mains including AC and DC wiring. Microprocessor based Genset controller and monitoring unit for Mains and DG set supply with AMF with all required standard controls, relays, protective systems, digital type Multi functional Meter with displays, indicator lamps for various functions all as specified and directed suitable for 50 KVA DG set. Note: (a) Adequate space shall be provided for cable entry and exit (Minimum 4 Nos of cable of 3.5 core 120 Sqmm cable) shall be provided in the AMF panel. (b) Necessary modifications to the inside DG set including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost. .
Supply and fix in replacement cubical indoor type, weather proof, AMF Control panel fabricated out of 2 mm thick CRCA MS sheet for outer panel and 1.6 mm MS sheet for internal compartments, powder coated incorporating the following items including control wiring etc Mechanically and electrically interlocked 2 Nos 4 pole power contactors of 125 Amps rating mounted side-by-side on a base plate for changeover of engine and main supply, 2 Nos of 100 Amps 35 KA, 4 pole MCCB with overload relay range of appropriate rating for incoming mains supply and engine alternator set supply control including static battery charger of suitable rating with auto cut off facility for charging the battery from mains including AC and DC wiring. Microprocessor based Genset controller and monitoring unit for Mains and DG set supply with AMF with all required standard controls, relays, protective systems, digital type Multi functional Meter with displays, indicator lamps for various functions all as specified and directed suitable for 62.5 KVA DG set. Note: (a) Adequate space shall be provided for cable entry and exit (Minimum 4 Nos of cable of 3.5 core 120 Sqmm cable) shall be provided in the AMF panel. (b) Necessary modifications to the inside DG set including drilling / welding etc as required to fix the contactor shall be carried out by the contactor without any extra cost. .
Supply and fix in repair, MCCB 250 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fix in repair, MCCB 200 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fix in repair, MCCB 160 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed
Supply and fix in repair, MCCB 125 Amps , FP , 415 Volts, rupturing capacity 35 KA, 50 Hz including spreader terminals complete all as specified and directed
Sunhari Electricals (BID ID -3377800)
PROLINK COMPUTERS (BID ID -3377376)
Suchit constructions (BID ID -3377441)
A K ENTERPRISES (BID ID -3377322)
R k construction (BID ID -3377737)
M/S - SUJIT ELECTRICALS (BID ID -3376573)
RELIABLE ENTERPRISES (BID ID -3377203)
D H L ENTERPRISES (BID ID -3377639)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .