| 1 | L-1₹4.9 LAccepted-AOC NEAR BSNL EXCHANGE WARD NO 14 BIRSINGHPUR PALI DISTT UMARIA M P | BIRSINGHPUR PALI | UMARIA | MADHYA PRADESH | L-1 | Accepted-AOC Accepted as L-1 | |
| 2 | Rejected-Technical AT PO BANDHABAHAL DIST JHARSUGUDA 768211 | BANDHABAHAL | JHARSUGUDA | ODISHA | 768211 | - | Rejected-Technical Reject as L-6 bidder | |
| 3 | Rejected-Technical NEAR TELEPHONE EXCHANGE DHANPURI DISTT SHAHDOL MADHYA PRADESH | DHANPURI | SHAHDOL | MADHYA PRADESH | 484114 | - | Rejected-Technical Reject as L-5 bidder | |
| 4 | Rejected-Technical 12 69 NEAR BLOCK OFFICE GAYATRI MANDIR LINE WARD NO 12 BIRSINGHPUR PALI BIRSINGHPUR PALI UMARIA MADHYA PRADESH 484551 UDYAM MP 50 0001263 | UMARIA | MADHYA PRADESH | 484551 | - | Rejected-Technical Reject as L-3 bidder | |
| 5 | Rejected-Technical CAMP CHACHAI DISTT ANUPPUR MP 484220 | CHACHAI | ANUPPUR | MADHYA PRADESH | 484220 | - | Rejected-Technical Reject as L-7 bidder |
Tender Value
₹10.6 L
EMD Value
₹13,200
Closing Date
4 Feb 2023, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Staff Officer EnM SECL Sohagpur Area
Staff Officer EnM SECL Sohagpur Area Dhanpuri Distt Shahdol MP 9425533402
Erection of LT Over Head Line for Quarry Lighting at Rampur Batura OCM of Sohagpur Area
2023_SECL_268007_1
SECL/SGP/EnM/eT/22-23/193 Date 17.01.2023
Open Tender
Electrical and Maintenance Works
Item Rate
45 days
Rampur Batura OCM Sohagpur Area
As per NIT and Tender documents
5 documents required · 5 mandatory
₹13,200
6 Mar 2023
19 Jan 2023
6 Feb 2023
19 Jan 2023
4 Feb 2023
20 Jan 2023
19 Jan 2023 - 28 Jan 2023
Amount
Erection of LT Over Head Line for Quarry Lighting at Rampur Batura OCM of Sohagpur Area.
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 8.0 metre and upto 11.0 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) fundation including excavation and refilling etc. as required.
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 4 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required .
Supplying of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) cross arm for 2 wire over head line complete with clamps, bolts, nuts and washer etc including drilling of holes for insulator pins etc (as per drawing) and painting with primer and finished paint as required
Erection of angle iron/ channel iron cross arm on wood/ RCC/ PCC/ steel tubular/ rail pole etc. as required.
Supplying and erection of 100 mm X 110 mm shackle insulator with G. I. Bolt, nuts and straps etc. as required .
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required. 620x4 = 2480 mtr 2480x 0.214= 530.72 KG and 2660x2= 5320 mtrs 5320x0.214= 1138.48 kg, total 530.72+1138.48 = 1669.20 kg
Erection of cradle Guard as required.
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 200 A, 16 KA,TPMCCB
Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A, 16 KA,TPMCCB
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A
Total impact of GST for the purpose of CTC
zealots enterprises
KAMRAN KHAN
Vindhyavasini Electrical workshop
Azhar Enterprises
AJAY KUMAR SINGH
M FAIYAZ CONTRACTOR
stage.html
html • 0.04 MB
techsummary_277269.pdf
PDF • 0.50 MB
finsummary_277269.pdf
PDF • 0.50 MB
LOI193.pdf
PDF • 0.72 MB
BOQ Comparative Chart
xlsx • 0.01 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .