Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
₹31.6 L
EMD Value
₹63,300
Closing Date
1 Jan 2026, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
ELECT G
12 conditions · 1 needing a document upload
(i)For participating in tender for an electrical nature of work, the contractor shall have to possess valid Electrical License of appropriate voltage issued by any State Government under clause 45 of compilation of rule of Indian Electricity rules 1956 or as amended from time to time. Electrifications of 11 KV and above including OHE, "A" class electrical contractor license is essential. (ii) The license can be possessed with one of the partners or in his own name if sole proprietor. Firm should submit a self-attested copy of the electrical contractor license along with the offer, otherwise, the offer will be summarily rejected
I/we the tenderer (s) am/are signing this document after carefully reading the contents.
I/We the tenderer(s) also accept all the conditions of the tender and have signed all the pages in confirmation thereof.
I/we hereby declare that I/we have downloaded the tender documents from Indian Railway website www.ireps.gov.in . I/we have verified the content of the document from the website and there is no addition, no deletion or no alteration to the content of the tender document. In case of any discrepancy noticed at any stage i.e. evaluation of tenders, execution of work or final payment of the contract, the master copy available with the railway Administration shall be final and binding upon me/us.
I/we declare and certify that I/we have not made any misleading or false representation in the forms, statements and attachments in proof of the qualification requirements.
I/We also understand that my/our offer will be evaluated based on the documents/credentials submitted along with the offer and same shall be binding upon me/us.
I/We declare that the information and documents submitted along with the tender by me/us are correct and I/we are fully responsible for the correctness of the information and documents, submitted by us.
I/we certify that I/we the tenderer(s) is/are not blacklisted or debarred by Railways or any other Ministry / Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/ member of the partnership firm/LLP/JV/Society/Trust.
I/we understand that if the contents of the certificate submitted by us are found to be forged/false at any time during process for evaluation of tenders, it shall lead to forfeiture of the Bid Security and may also lead to any other action provided in the contract including banning of business for a period of upto two year. Further, I/we and all my/our constituents understand that my/our offer shall be summarily rejected.
I/we also understand that if the contents of the certificate submitted by us are found to be false/forged at any time after the award of the contract, it will lead to termination of the contract, along with forfeiture of Bid Security/Security Deposit and Performance guarantee and may also lead to any other action provided in the contract including banning of business for a period of upto two year.
I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am/We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfil all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by the competent authority is enclosed)
13 conditions · 2 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying criteria mentioned in the tender document. It will not be obligatory on the part of tender committee to scrutinize beyond the submitted document of tenderer as far as his qualification for the tender is concerned. The railway reserves the right to verify all statements, information and documents submitted by the bidder in his tender offer, and the bidder shall, when so required by the railway, make available all such information, evidence and documents as may be necessary for such verification. Any such verification or lack of such verification, by the railway shall not relieve the bidder of its obligations or liabilities hereunder nor will it affect any rights of the railway there under.
No post tender correspondence shall be entertained after closing of tender even Suo moto post tender letters of the tenderers shall be treated as null/void.
The tenderers are required to observe the website to find out if any correction slips issued subsequent to uploading of the Tender . Railway reserves the right to make any additions/alterations to the tender uploaded and issue corrigendum to the same effect. In case the tenderer fails to take note of the above corrigendum, the additions and alterations entered/effected in the corrigendum shall be binding upon the tenderer and no claim what so ever will be entertained by Railway.
The tenderer should upload the documents carefully. The documents uploaded by tenderer should be clearly visible and in legible format.
Indian Railways Standard General Conditions of contract 2022 along with correction slips corrected up to date of closing of tender and the attached documents are part of the tender document.
The offers which are incomplete, without supporting documents, unsigned, conditional, will be summarily rejected.
As per letter No. 2022/CE-I/CT/GCC/Correspondence/ New Delhi, dated 14.05.2024 "On IREPS Module , a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V of GCC & uploading of physically signed Annexure-V by tenderer had been discontinued on IREPS"
Provision of additional room ( Prefeb) in Running Room SGO under ADEN/SGO sub- division.
JBP-L-T-No-37-2025~WCR
JBP-L-T-No-37-2025
Open
Works - General
6 Months
Jabalpur, Madhya Pradesh
₹0
₹63,300
1 Jan 2026
8 Dec 2025
18 Dec 2025
45 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 31,63,522.05 | ||
| for | Item Breakup | details. | — | ||
| LT power panel outdoor type fabricated approx. size 1.25 x 1.25 x 0.4 Mtrs made out of 2mm MS sheetpowder coated paint having copper busbars of size 50 x 8 x suitable length to cater a load of 400Amps. The incoming shall have 2 x 400Amps MCCB 4 pole (25 KA) andoutgoing with 6 x 200 A 4PMCCB (25KA) + 2 x 160 A 4P MCCB. The panel shall have onemultifunction meter. All MCCB will be 4pole, o of make ABBorequivalent. The panel shall have channels at the base of suitable size. All theMCCBs shall be of legrand , ABB, L&T, Schnider, Hager,Simens make or equivalent. (Dismantling ofexisting panel, structre, disconnection , reconnection of cable and released material tranported tonearest depot by contractor)Design of panel will be approved by comptent authority before supply,2mm MS sheet duly painted with powder coated , IP-65, IK-09 having suitable copper bus bars withsleeves , indicating lamps, multifunction meter , Gland ,Lugs, | — | — | — | 1,82,983.9 | |
| for | Item Breakup | details. | — | ||
| LT power panel outdoor type fabricated approx size 1.25x1.25x.0.4 mtrs made out of 2 mm MSsheetpowder coated paint having copper busbar of size 50x6x suitable legth .The incoming shallhaving2x250 A MCCB 4 pole 25 KA and outgoing with 2x200 A MCCB 4 pole plus2x100 A 4poleMCCB & 2x63A MCCB .The panel shall have one multifunctional meter.All MCCB will be 4 pole make Legrand, ABBL&T or equivalent.The panel shall have channels at the baseof suitable size.The erection is to be doneon suitable foundation of cement concrete mixtures. (Dismantling of existing panel, structre,disconnection , reconnection of cable and released material tranported to nearest depot bycontractor)Design of panel will be approved by comptent authority before supply,2 mm MS sheet dulypainted with powder coated , IP-65, IK-09 having suitable copper bus bars with sleeves , indicatinglamps, multifunction meter , Gland ,Lugs, Foundation , earthing , Door Lock arrangment, pad lock,suitable MS channel , SWG wire etc | — | — | — | 1,32,242.19 | |
| for | Item Breakup | details. | — | ||
| SDB for light and fan. TPN DB 4 way (8+12) IP-43 with metal door, 4 with ELCB, RCCB 32A TPN incomer and outgoing having 5 x 10A SPMCB and 5 x 6A SP MCB with pherrol MCB make - Legrand, Havells, Hager, simens or equivalent , | — | — | — | 48,026.24 | |
| for | Item Breakup | details. | — | ||
| "SDB for Power. TPN DB 4 way (8+12) IP-43 with metal door, with ELCB, RCCB 63A TPN incomer and outgoing having 5 x 32A SPMCB and 5 x 20/16A SP MCB. MCB make - Legrand, Havells, Hager, simens or equivalent " | — | — | — | 53,071.84 | |
| for | Item Breakup | details. | — | ||
| "Supply and Erection of Ceiling fan including electronic modular fan regulator, suitable down rod , Metal fan hook, flexible Pipe, fan box, with all necesaary arangment (BLDC, 5 star rated, 1200 mm Make- Atomberg, Usha , Bajaj,Havells or simillar make) Sample will be approved by comptent authority befor supply " | — | — | — | 2,62,494.08 | |
| for | Item Breakup | details. | — | ||
| Supply and Erection of E/Fan 380mm sweep Erection includes and fixing is to be done on already provided finished opening in the wall using required fasteners , their grouting and then connection is to be given from ceiling rose to this fan using cable of 1.5 sq. mm . size. | — | — | — | 16,471.26 | |
| for | Item Breakup | details. | — | ||
| Supply and Erection of 1 x 18/20W LED fittings 4 feet length. The fittings shall have to be erected by the contractor with all fixing accessories/MS clamps, nuts bolts etc. as per requirement at site. " | — | — | — | 5,265.36 | |
| for | Item Breakup | details. | — | ||
| "Supply, erection , testing and comssioning of 2X2 LIGHT 36W Led Recessed Luminaire IS:10322/part5/sec-2/2012 and IS 16107 (Part 2/Sec 1) : 2012 for Recess type Sample will be approved by comptentauthority befor supply Make- Syska, Havells, Wipro, Bajaj, Crompton or equivailent | — | — | — | 1,62,360 | |
| for | Item Breakup | details. | — | ||
| Supply, installation, testing & commissioning of16 watt LED Down lighter or equivalent down lighter Sample will beapproved competent authority before supply | — | — | — | 70,290 | |
| for | Item Breakup | details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x2.5 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 2.5 sqmm with one wire of 1.5 sqmm for earth conn). | — | — | — | 51,418.5 | |
| for | Item Breakup | details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x4 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of4 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 60,129 | |
| for | Item Breakup | details. | — | ||
| Supply, erection, testing and commissioning of Sub Main with 2 x 6 sqmm FRLS copper wire inside PVC Casing caping with running earth etc complete. (1 m length of submain consists one cktmtr including all accessories & 2 wire of 6 sqmm with one wire of 2.5 sqmm for earth conn). | — | — | — | 88,900.5 | |
| for | Item Breakup | details. | — | ||
| Concealed Wirings:25A/32A MCB and socket for air conditioner / Gyser/ Water cooler: (modular) Havells, Wipro, Orient, Bajaj, crompton or equivalent | — | — | — | 46,853.2 | |
| for | Item Breakup | details. | — | ||
| Supply, installation, testing & commissioning of 20 Amp AC box 1x25 No motor starter modular type switch and1No 16/20 A RCBO power supply to AC | — | — | — | 1,53,671.2 | |
| for | Item Breakup | details. | — | ||
| Supply and laying/connecting of 8/10/12 SWG GI wire as per requirement at site. This is to be connected with the earth pit to the installation. | — | — | — | 581 | |
| for | Item Breakup | details. | — | ||
| Pipe Earthing : Supply of material for Earthing pit as per IS-3043, Erection includes excavation of earth, filling of salt, charcoal, B class GI pipe with funnel at top with cast iron cover having handle and cement concrete chamber etc. as per IS latest with inscription ligibility of IR value on top of earth pit chamber with serial no-etc.Then testing with earth tester. | — | — | — | 6,544.28 | |
| for | Item Breakup | details. | — | ||
| Laying of cable on wall/pipe/pole. Cable shall be supplied by Railways free of cost which shall be transported by contractor from depot to site at his cost. | — | — | — | 3,217.5 | |
| for | Item Breakup | details. | — | ||
| Removing, Shafting,relaying of existing cable in trench, wall, soil, roof, track crossing, road crossing,cable tray, etc including MS clamp, nut, bolt, Screw, Nails,gland, lugs.Disconnection, proper reconnection,from panel or any other thing. | — | — | — | 14,175 | |
| for | Item Breakup | details. | — | ||
| Excavation of Cable trench in Cement Concrete and laying of cable, The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to thesite | — | — | — | 13,956.6 | |
| for | Item Breakup | details. | — | ||
| "Cable laying single in earth. The cable shall be supplied by Railways free of cost from depot at JBP which shall have to be transported from depot to site by contractor at his cost and then its laying.crossing rly. track/platform/road / soil/ hard murrum after diggingof trench and back filling with excavated earth after laying of pipe and making good the damages as required " | — | — | — | 9,100 | |
| for | Item Breakup | details. | — | ||
| Cable laying double in earth.(LT, HT both type) This involves Excavation of 1000mm deep trench in soil/hardmurrum/tar road/below Railway track. After this the cable shall be laid and then both sides are to becovered with bricks. The rest of the trench to be refilled by sheaved earth. The cable shall be suppliedfree of cost by Rly's which shall have to be transported by the contractor from Rly. depot,JBP to the site | — | — | — | 23,660 | |
| for | Item Breakup | details. | — | ||
| Supply, fixing, testing and commissioning of 1.5 Ton 5 Star rating Split AC, single Phase,dust filter, make Mitsubishi Heavy, O Gernal,daikin, samsung or equivalent with suitable size of stand. Metalic cage, copper tube as per site requirement , and all other accessories required for installation. | — | — | — | 17,58,110.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
37-2025tenderdoc.pdf
ATTACHMENT
AC08to10.pdf
ATTACHMENT
Allcorrectionslip.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .