| 1 | L1₹2.7 CrAccepted-AOC FLAT NO 601 TOWER NO 30 SECTOR NO 21 AMANORA PARK TOWN HADAPSAR PUNE 411028 | PUNE | MAHARASHTRA | 411028 | ₹2.7 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹2.8 CrRejected-Finance SHOP NO 10 BMC SHOPPING CENTRE MITHA NAGAR GOREGAON W MUMBAI 400 104 | MUMBAI SUBURBAN | MAHARASHTRA | 400104 | ₹2.8 Cr | L2 | Rejected-Finance Not lowest |
| 3 | L3₹2.8 CrRejected-Finance | ₹2.8 Cr | L3 | Rejected-Finance Not lowest |
| 4 | L4₹3.0 CrRejected-Finance | ₹3.0 Cr | L4 | Rejected-Finance Not lowest |
| 5 | L5₹3.4 CrRejected-Finance BHAPKAR PATIL PLOT NO 24 GURHSHIP HOUSING SOCIETY SATBHAL MALA DEHIGATE AHMEDNAGAR 414001 | AHMEDNAGAR | AHMEDNAGAR | MAHARASHTRA | 414001 | ₹3.4 Cr | L5 | Rejected-Finance Not lowest |
| Sl No | Description | Qty | Unit | S G Enterprises L3 | M/s S. R. Constructions L5 | UNIQUE ENGINEERS L1 | Shree Ayyappa Engineering L2 | Shri Sant Cosntruction L4 |
|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling / taking down doors, windows and clerestory windows (steel, aluminium or wood) shutter including chowkhats, architrave, holdfasts etc and stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed. | 60 | EACH | 300 ₹18,000 | 1,500 ₹90,000 | 235 ₹14,100 | 240 ₹14,400 | 320 ₹19,200 |
| 2.00 | Dismantling / taking out doors windows and clereslory window shutters (steel, aluminium or wood) including stacking within 50metres lead of area 3 sqm and below complete all as specified and directed. | 10 | EACH | 150 ₹1,500 | 2,000 ₹20,000 | 140 ₹1,400 | 265 ₹2,650 | 200 ₹2,000 |
| 3.00 | Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed. | 1 | CUBIC METRE | 350 ₹350 | 4,000 ₹4,000 | 1,690 ₹1,690 | 539.8 ₹539.80 | 2,000 ₹2,000 |
| 4.00 | Taking down / chipping of all swolen / loose concrete in chajjas / beams, roughening the surface with wire brushes and applying a coat of cement slurry @ 1.20 kgs per Sq.m of surface, and rendering 15mm CM 1:4 complete all as specified and directed. | 20 | SQUARE METRE | 400 ₹8,000 | 5,000 ₹1 L | 282 ₹5,640 | 345 ₹6,900 | 200 ₹4,000 |
| 5.00 | Demolishing brick work built in cement mortor manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed. | 4.5 | CUBIC METRE | 250 ₹1,125 | 3,000 ₹13,500 | 1,125 ₹5,062.50 | 460 ₹2,070 | 500 ₹2,250 |
| 6.00 | Material and Labour for PCC block masonry with soild blocks type C1, 1:3:6 (20mm grade stone aggregate) exceeding 10 cm in width and setting in CM 1:6 cement mortar complete all as specified and directed. | 4.5 | CUBIC METRE | 6,200 ₹27,900 | 8,000 ₹36,000 | 7,050 ₹31,725 | 7,800 ₹35,100 | 8,000 ₹36,000 |
| 7.00 | Dismantling tile work in floors, walls and roofs for thickness of tiles 10 mm to 25 mm laid in cement mortar including stacking material within 50 metres lead complete all as specified and directed. | 1,146 | SQUARE METRE | 25 ₹28,650 | 100 ₹1.1 L | 55 ₹63,030 | 38 ₹43,548 | 30 ₹34,380 |
| 8.00 | Demolishing cement concrete of any description and position manually / by mechanical means including disposal of material within 50 metres lead as per direction complete all as specified and directed. | 33.02 | CUBIC METRE | 500 ₹16,510 | 3,000 ₹99,060 | 1,130 ₹37,312.60 | 510 ₹16,840.20 | 250 ₹8,255 |
| 9.00 | Taking down of old plaster of any description and position and raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed. | 450 | SQUARE METRE | 15 ₹6,750 | 150 ₹67,500 | 40 ₹18,000 | 35 ₹15,750 | 30 ₹13,500 |
| 10.00 | Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed. | 3,450 | KILO GRAM | 30 ₹1.0 L | 50 ₹1.7 L | 8 ₹27,600 | 3 ₹10,350 | 10 ₹34,500 |
Updated dates
Tender Value
₹2.8 Cr
EMD Value
₹3.6 L
Closing Date
10 Dec 2025, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
SPECIAL REPAIRS TO BUILDING No. P179 SEMINAR CUM MODEL ROOM AUDITORIUM AT RNDE ENGRS DIGHI PUNE UNDER GE I RND GIRINAGAR, PUNE
2025_MES_725513_2
85332
Open Tender
Civil Works
365 days
GIRINAGAR PUNE
Class B
category a(i)
8 documents required · 8 mandatory
₹2,000
GARRISON ENGINEER I RND GIRINAGAR PUNE
₹3.6 L
Yes
26 Feb 2026
12 Nov 2025
12 Dec 2025
12 Nov 2025
10 Dec 2025
26 Nov 2025
Amount
Dismantling / taking down doors, windows and clerestory windows (steel, aluminium or wood) shutter including chowkhats, architrave, holdfasts etc and stacking within 50 metres lead of area 3 sqm and below complete all as specified and directed.
Dismantling / taking out doors windows and clereslory window shutters (steel, aluminium or wood) including stacking within 50metres lead of area 3 sqm and below complete all as specified and directed.
Demolishing R.C.C. work manually / by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead complete all as specified and directed.
Taking down / chipping of all swolen / loose concrete in chajjas / beams, roughening the surface with wire brushes and applying a coat of cement slurry @ 1.20 kgs per Sq.m of surface, and rendering 15mm CM 1:4 complete all as specified and directed.
Demolishing brick work built in cement mortor manually / by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead complete all as specified and directed.
Material and Labour for PCC block masonry with soild blocks type C1, 1:3:6 (20mm grade stone aggregate) exceeding 10 cm in width and setting in CM 1:6 cement mortar complete all as specified and directed.
Dismantling tile work in floors, walls and roofs for thickness of tiles 10 mm to 25 mm laid in cement mortar including stacking material within 50 metres lead complete all as specified and directed.
Demolishing cement concrete of any description and position manually / by mechanical means including disposal of material within 50 metres lead as per direction complete all as specified and directed.
Taking down of old plaster of any description and position and raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead complete all as specified and directed.
Dismantling steel work in built up sections in angles, tees, flats and channels including all gusset plates, bolts, nuts, cutting rivets, welding etc. including dismembering and stacking within 50 metres lead complete all as specified and directed.
Dismantling roofing GS sheets including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead complete all as specified and directed. Note: Work will be executed at a height of upto 20m. Hence necessary scaffloding and all sefety precaution deemed to be included under rate quoted by contractor.
S&F, precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm (+ 0.05 %) total coated thickness with zinc coating and 80 to 100 mm thick sandwich puf, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre. The sheet shall be fixed using self drilling / self tapping screws of size (5.5 x 55 mm) with EPDM seal or as per laid specification as complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
S&F, precoated galvanised steel sheet roofing accessories Ridges plain 600mm width 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling / self tapping screws complete all as specified and directed.
S&F, precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) 0.50 mm (+ 0.05%) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-Charge. The sheet shall be fixed using self drilling / self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal / vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required complete all as specified and directed.
M&L for structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and complete all as specified and directed.
M&L for steel in gratings, frames, guard bar, ladder, railings, brackets, gates and similar work welded in built up sections / framed work, including cutting, hoisting, fixing in position using structural steel complete all as specified and directed.
M&L for applying two coats on new work including a coat of primer of (wooden / steel) for painting with synthetic enamel paint of approved brand and manufacture to give an even shade on wooden and steel surface complete all as specified and directed.
M&L for applying one coat on old work on (wooden / steel) for painting with synthetic enamel paint of approved brand and manufacture to give an even shade on wooden and steel surface complete all as specified and directed.
S&F, powder coated aluminium (minimum thickness of powder coating 50 micron) aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections / appropriate Z sections and other sections of approved make, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions i.e., at top, bottom and sides with required EPDM rubber / neoprene gasket etc., aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, complete all as specified and directed. (Glazing, wire mesh to be paid for separately under relevent items for payment purpose).
S&F, powder coated aluminium (minimum thickness of powder coating 50 micron) shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required complete all as specified and directed. Note: Only weight of aluminium members deemed to be considered for payment purpose.
S&F, glazing with float glass panes of 5mm thickness in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc., complete all as specified and directed.
S&F, glazing with float glass panes of 8mm thickness in aluminium door, window, ventilator shutters and partitions etc., with EPDM rubber / neoprene gasket etc., complete as per specified and directed.
S&F, factory made P.V.C. door frame of size 50mm x 47 mm with a wall thickness of 5 mm, wood grain printed PVC sheet & edges will be paintd to match with printed sheet made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15mmx15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19mmx19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as specified and directed.
S&F, factory made panel PVC door shutter of 30mm thickness wood grain printed PVC sheet consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15 x 15 mm for top & bottom rails M.S. frame shall have a coat of steel primers of approved make and manufacture M.S. frame covered with 5 mm thick heat moulded PVC 'C' channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mm wide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel 10 mm (5 mm x 2) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded / sealed to the styles & rails with 7 mm (5 mm+2 mm) thick 15 mm wide PVC sheet beading on inner side and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the 'C' Channel using PVC solvent adhesive etc., complete all as specified and directed.
Providing and fixing ISI marked flush door shutters of 35 mm thickness of decorative type, core of block board construction with frame of IInd class hard wood and well matched both side laminated of shutters complete all as specified and directed.
M&L for 40mm x 5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 30mm x 10mm x 15cm, 1:3:6 type C1 mix (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) complete all as specified and directed.
S&F, 300mm aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10), transparent or dyed to required colour or shade with nuts and screws etc., complete all as specified and directed.
S&F, 150mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10) transparent or dyed to required colour or shade with necessary screws etc., complete all as specified and directed.
S&F, 250mm aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10) transparent or dyed to required colour or shade, with necessary screws etc., complete all as specified and directed.
S&F, 125 mm aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10) transparent or dyed to required colour or shade, with necessary screws etc., complete all as specified and directed.
S&F, aluminium hanging twin rubber stopper floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10) transparent or dyed to required colour and shade with necessary screws etc., complete all as specified and directed.
S&F, ISI marked 100mm M.S. pressed butt hinges bright finished with necessary screws etc., complete all as specified and directed.
S&F in repair double action hydraulic floor spring of approved brand and manufacture having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kgs for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc., complete as specified and directed.
S&F in repair aluminium extruded section body tubular type universal hydraulic door closer (having brand logo with embossed on the body, door weight upto 36 kgs to 80 kgs and door width from 701 mm to 1000 mm) with double speed adjustment with necessary accessories and screws etc., complete all as specified and directed.
S&F in repair and fixing bright finished 100 mm mortice lock with 6 levers without pair of handles of approved quality for aluminium door with necessary screws complete all as specified and directed.
M&L for cement concrete 1:2:4 type B1 using 20mm graded stone aggregate as in sub base of floor complete all as specified and directed.
M&L for providing and laying glazed vitrified tiles double charge in floor in size of tile 800mm x 800 mm (thickness to be specified by the manufacturer) with water absorption less than 0.08% and approved brand & manufacturer in all colours and shade, laid on including provisioning screed bed 20 mm thick cement mortar 1:4 (1 cement : 4 coarse sand) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments. The tiles must be cut with the zero chipping diamond cutter only. Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily complete all as specified and directed.
M&L for providing and laying glazed vitrified tiles double charge in 800mm x 800mm size of tile (thickness to be specified by manufacturer) with water absorption less than 0.08% and conforming to approved make in all colours & shade in skirting, riser of steps, over 12 mm thick backing coat and inclusive provisioning of cement mortar 1:3 (1 cement : 3 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joint with white cement & matching pigments complete all as specified and directed.
M&L for providing and laying rectified glazed ceramic floor tiles of size exceeding 0.09 sqm and not exceeding 0.16 Sqm of 1st quality conforming to IS:15622 of approved make in colours White, Ivory, Grey, Fume Red Brown, laid on and inclusive provisioning screed bed 20 mm in thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments complete all as specified and directed.
M&L for providing and laying Ist quality ceramic glazed wall tiles of size exceeding 0.12 sqm and nexc 0.24 sqm to conforming to IS:15622 of approved make in all colours, shades except burgundy, bottle green, black of any size as approved in skirting, risers of steps and dados, over inclusive provisioning of 12 mm (average) thick backing coat of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kgs per sqm, including pointing in white cement mixed with pigment of matching shade complete all as specified and directed.
S&F, 20-22mm thick kota stone slab flooring laid over and including provisioning of 20mm (average) thick of screed bed in cement mortar 1:3 (1 cement : 3 coarse sand) laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and mirror polishing complete all as specified and directed.
S&F, prepolished kota stone slabs 20 mm thick in risers of steps, skirting, dado laid on and including provisioning of 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs complete all as specified and directed.
M&L for providing and laying flamed granite stone slab Jet Black, Cherry Red, Elite Brown, Cat Eye as approved flooring in required design and patterns in linear as well as curvilinear portions of the building with 18 mm thick stone slab over and including 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing complete as specified and as directed.
Mirror polishing on marble work / granite work / stone work wherever required to give high gloss finish complete all as specified and directed.
M&L for providing and laying 18 mm thick granite stone slab colour black, Cherry / Ruby red, area of slab over 0.50 sqm, gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over and including provisioning of 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish complete all as specified and directed.
Extra for providing opening of required size & shape for wash basin / kitchen sink in kitchen platform, vanity counter and similar location in marble / granite / stone work, including necessary holes for pillar taps etc., including moulding, rubbing and polishing of cut edges etc., complete all as specified and directed.
Extra for fixing marble / granite stone over and above corresponding basic item in facia and drops of width upto 150 mm with epoxy resin based adhesive including cleaning etc., complete all as specified and directed.
M&L for providing and laying Udaipur green marble of 18 mm thick area of slab over 0.50 sqm gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over and including provisiong of 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish complete all as specified and directed.
M&L for providing and laying machine cut cudappa stone slab 20-25mm thick jointed with grey cement slurry mixed with pigment to match the shade of the slab complete all as specified and directed.
S&F, wash basin snow white (Table Top) of size 530mm x 425mm x 140 mm including 15 mm C.P. brass fancy swan neck table top pillar taps, 32 mm PVC waste pipe and necessary fitting of standard pattern including fitting on slab complete all as specified and directed.
S&F in repair stainless steel 'A' ISI 304 (18/8) kitchen sink of overall size 495mm x 420mm bowl size 410mm x 330mm x 160mm as per IS:13983 with C.I. brackets and stainless steel plug 40 mm including painting of fittings and brackets, cutting and making good the walls wherever required complete all as specified and directed.
S&F in repair white vitreous china orrisa pattern WC pan of size 530mm x 425mm with integral type foot rests and 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern of approved make, including flush pipe with manually controlled device (handle lever) conforming to IS:7231 with all fittings and fixtures complete including cutting and making good the walls and floors wherever required complete all as specified and directed.
S&F in repair white vitreous china full stall urinal flat back lipped front urinal basin of size 350 x 340 x 615 mm with 15 mm CP urinal spreader weighting not less than 60gms & CP urinal cock of approved quality and necessary fitting colour complete all as specified and directed.
S&F in repair CP brass 32mm size bottle trap of approved quality & make complete all as specified and directed.
S&F in repair white vitreous china pedestal type water closet one piece of size (size 655 x 345 x 750mm (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe with manually controlled device (handle lever) with all fittings and fixtures complete including cutting and making good the walls and floors wherever required : W.C. pan with ISI marked white solid plastic seat and lid complete all as specified and directed.
S&F in repair 15mm bore two ways bib cock (chromium plated) with inlet and outlet screwed for pipe and connections including necessary fittings complete all as specified and directed.
S&F in repairs 15mm bore heath faucet (chromium plated) with inlet and outlet screwed for pipe and connections including necessary fittings complete all as specified and directed.
S&F in repair C.P. brass stop cock (concealed) of standard design and of approved make conforming to IS:8931,15 mm nominal bore complete all as specified and directed.
S&F in repair C.P. brass angle cock for flush tank and geyser points of approved 15mm nominal bore complete all as specified and directed.
S&F in repair 450 mm uplasticised PVC connection pipe, 15 mm nominal bore with brass unions and nuts complete all as specified and directed.
S&F in repair CP towel rail of size 600 mm fancy type complete with brackets fixed with screws with concealed fittings arrangement of approved quality complete all as specified and directed.
S&F in repair CP brass toilet paper holder complete all as specified and directed.
S&F in repair C.P. brass long body bib cock, 15 mm nominal bore of approved quality complete all as specified and directed.
S&F in repair 50mm bore Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
S&F in repair 100 mm inlet and 75 mm outlet trap of self cleansing design with screwed down or hinged grating with or without vent arm complete including cost of cutting and making good the walls and floors complete all as specified and directed.
Taking up or down 15mm bore steel tubing and connections including cleaning for refixing with new fittings complete all as specified and directed.
Taking up or down 20mm bore steel tubing and connections including cleaning for refixing with new fittings complete all as specified and directed.
S&F, 15mm Chlorinated Polyvinyl Chloride (CPVC) pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement as in walls or concealed work and the cost of cutting chases and making good the same including testing of joints complete as specified and directed.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) 20 mm nominal dia pipes having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing this includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete all as specified and directed.
S&F, 1000 ltrs capacity polyethylene water storage tank, IS:12701 marked with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings complete all as specified and directed.
S&F in repair 20mm bore gun metal gate valve with C.I. wheel of approved quality (screwed end) complete all as specified and directed.
S&F in repair 20mm bore PTMT ball cock of approved quality, colour and make complete with epoxy coated aluminium rod with L.P. / H.P.H.D. plastic ball complete all as specified and directed.
S&F, 20mm bore PTMT extension nipple for water tank pipe, fittings of approved quality and colour complete all as specified and directed.
Rounding and noising to edges of stone slabs one edge such as in steps, cooking platform and other similar situations complete all as specified and directed.
S&F, 110mm bore on wall face unplasticised rigid PVC rain water pipes single socketed on wall face conforming to IS:13592 type A, including jointing with seal ring 10 mm gap for thermal expansion complete all as specified and directed.
S&F, unplasticised PVC moulded 110mm bore bend 87.5° fittings wall face for unplasticised rigid PVC rain water pipes confirming to IS:13592 type A, including jointing with seal ring leaving 10 mm gap for thermal expansion complete all as specified and directed.
S&F, unplasticised PVC moulded 110mm dia shoe (plain) on wall face for unplasticised rigid PVC rain water pipes confirming to IS:13592 type A, including jointing with seal ring leaving 10 mm gap for thermal expansion complete all as specified and directed.
S&F, unplasticised PVC moulded 110mm x 110mm x 110mm single tee with door on wall face for unplasticised rigid PVC rain water pipes confirming to IS 13592 type A, including jointing with seal ring confirming to IS:5382 leaving 10 mm gap for thermal expansion complete all as specified and directed.
S&F, 110mm bore PVC (SWR) vent cowl complete all as specified and directed.
S&F, 75mm bore on wall face unplasticised rigid PVC rain water pipes single socketed on wall face conforming to IS:13592 type A, including jointing with seal ring 10 mm gap for thermal expansion complete all as specified and directed.
S&F, unplasticised PVC moulded 75mm bore bend 87.5° fittings wall face for unplasticised rigid PVC rain water pipes confirming to IS:13592 type A, including jointing with seal ring leaving 10 mm gap for thermal expansion complete all as specified and directed.
S&F, unplasticised PVC moulded 75mmx 75mm x 75mm single tee with door on wall face for unplasticised rigid PVC rain water pipes confirming to IS:13592 type A, including jointing with seal ring confirming to IS:5382 leaving 10 mm gap for thermal expansion complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:6 and making the surface even and fair without using extra cement complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1:4 and making the surface even and fair without using extra cement complete all as specified and directed.
M&L for preparation of new surface applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS:15489-2004, alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over over white cement based putty of average thickness 1 mm, of approved brand and manufacturer complete all as specified and directed.
M&L for finishing walls with two coats of ready mixed premium acrylic emuslion paint (company depot tinted) having VOC less than 50gm/litre and UV resistance as per IS:15489-2004 alkali & fungal resistance, dirt resistance exterior paint of required shade with silicon additives applied @ 1.67 ltr/10sqm over and including priming coat of exterior primer applied @ 2.20kg/10sqm with acrylic smooth exterior paint of required shade over new wall surface complete all as specified and directed.
M&L for complete removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches complete all as specified and directed.
M&L for preparation of old wall surfaces applying priming coats with primer of approved brand and manufacture having low VOC (Volatile Organic Compound) content with water thinnable cement primer on wall surface having VOC content less than 50 grams/litre over white cement based putty of average thickness 1 mm of approved brand and manufacturer over the plastered wall surface to prepare the surface even and smooth and applying two coats of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS:15489-2004, Alkali & fungal resistance, dirt resistance interior emulsion paint of required shade with silicon additives @ 1.43 litre/10 sqm complete all as specified and directed.
M&L for finishing walls with acrylic smooth exterior paint of required shade on Two coat applied new work (@ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) over new surface complete all as specified and directed.
Taking out old APP membrane of any thickness and description carefully without damaging the mother slab from roof and disposing off outside MD land complete all as specified and directed.
Demolition of cement concrete in roofs, floors (other than ground floors) of any thickness complete all as specified and directed.
M&L for providing, cement concrete type B0, 1:2:4 (12.5 mm graded stone aggregate) on roof as in levelling course and making the surface even and smooth complete all as specified and directed.
M&L for waterproofing treatment to sound, moisture free concrete surface system includes proper surface preparation to remove loose dust, dirt, loose mortar, curing compound and making the surface even and smooth to carry out cementitious injection grouting at leakage points and construction joints using cement slurry modified with Cebex 100-Plasticised expandive grout admixture supplied in 225 gm pouch, treatment of construction joints using polymer modified mortar prepared by using Nitobond SBR Latex, application of polymer modified vatta at floor-wall junction, filling of annular space around rain water outlet using Conbextra GP2 - Non-shrink cementitious grout any undulated surface and pot holes shall be filled with epoxy mortar to obtain sound / levelled surface.
Application of primer Nitoproof WB Primer on sound mother slab surface. Followed by application of two coats of Nitoproof 600PF - Liquid applied single component pitch free polyurethane coating supplied in 25 kgs drum coverage @ 2.3 kg/m2 to achieve 1.5 mm thickness in two coats complete including all tools and tackles as per manufacturer’s specification and as directed. Coating shall be having crack bridging of 2 mm, elongation (ASTMD 412) > 600%, tensile strength (ASTM D412) - 2.5 N/mm2, Recovery from Elongation (ASTM D412) - 95%, 85% Solid Content, Tear Resistance (ASTM D624) - 15 Kn/m, Shore A Hardness (ASTM D2240) - 60, Water vapour transmission not more than 1g/m2/hr, Water Permeability (DIN 1048) - Nil, Service Temperature -40°C to 70°C, Flash Point > 70 °C.
HSE Guidelines: It is recommended to provide adequate general and local exhaust ventilation, provide protection to eye, face, hand and other skin by wearing appropriate gloves, goggles, face shields, respiratory protection etc., as directed in SDS of the product.
Supply only liquid waterproofing compound complete all as specified and directed.
M&L for seperation & protection layer- Geotextile membrane 150 gsm prior to protection screed complete all as specified and directed.
Dismantling aluminium / Gypsum partitions, doors, windows, fixed glazing and false ceiling including disposal of unserviceable material and stacking of serviceable material with in 50 meters lead complete all as specified and directed.
M&L for Soft Fibre Acoustical Suspended Ceiling System with Optra (Bevelled Tegular) edge tiles with 15mm exposed Grid. The tiles should have Humidity Resistance (RH) of 95%, NRC 0.9 - 1.0, Light Reflectance ≥ 85%, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 15mm, suitable for green building application with recycled content of 66% GW & 74% RW. The tile shall be laid on suprafine 32 with 15 mm wide T section flanges colour white having rotary stitching on all T sections i.e., the main runner, 1200 mm & 600 mm cross tees with a web height of 32mm and a load carrying capacity of 7.5Kgs/M2 with a minimum pull out strength of 100 kgs. The T Sections have a galvanizing of 90 grams per M2 and need to be installed with suspension system and necessary angle and approved colour complete all as specified and directed.
S&F, ‘Optra Acoustical Wall Paneling’ with square edges made of fibre glass substrate 25mm thick and wrapped on the front side with an acoustically transparent and classified for fire reaction class A as per ASTM E-84, fabric with an option of colors - Husk, Copper, Sangria, Sesame, Coffee, Charcoal, Titanium, Flame, Peanut & shell as per the choice of the Architect of size 600 x 600 mm providing a minimum sound absorption level of 0.85 NRC to be affixed to wall using wall panel impalers and necessary aluminium frame work supplied by M/s Armstrong or equivalent make as approved by GE. Industries India Pvt Ltd and construction adhesives as per the instructions laid down by the manufacturer complete all as specified and directed.
S&F, channeled wood works perforated panels of width 192mm, thickness of 15mm and length 2400 mm or made of a high density fibre board with minimum 725 Kg/M3 density substrate with a laminated facing as per the approved shade & finish and a melamine balancing layer on the reverse side. The boards shall have a special perforation pattern where the visible surface has a “Helmholtz” fluted perforation of 3mm width and 21mm of visible panel each. The edges of the panels shall be “tongue-and-grooved” to receive special clips for installation. The back of the perforated panel shall have sound absorbing non-woven acoustical fleece having NRC of 0.52. The panels shall be mounted on special aluminium splines using clips and necessary aluminium frame work complete all as specified and directed.
S&F, bonded mineral wool blanket slab made from glass density 24 kg/Cum and fixed as per manufacturer instruction 40 mm thick and one side of blanket with polythene based jute hessian cloth including necessary binding accessories and removal of existing bonded mineral wool blanket slab complete all as specified and directed.
M&L for diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion): Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1:2 (1 cement : 2 coarse sand) to match the existing floor: with Chlorpyriphos / Lindane E.C. 20% with 1% concentration complete all as specified and directed.
M&L for diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion): along the external wall below concrete or masonry apron using chemical emulsion @ 2.25 litres per linear metre including drilling and plugging holes etc: with Chlorpyriphos / Lindane E.C. 20% with 1% concentration complete all as specified and directed.
M&L for Diluting and injecting chemical emulsion for POST-CONSTRUCTIONAL anti-termite treatment (including the cost of chemical emulsion): Treatment at points of contact of wood work by chemical emulsion Chlorpyriphos / Lindane (in oil or kerosene based solution) @ 0.5 litres per hole by drilling 6 mm dia holes at downward angle of 45 degree at 150 mm centre to centre and sealing the same complete all as specified and directed.
Taking down existing old unserviceable aluminium partion cum casement type windows cum doors fixed including fitting and fixtures complete all as specified and directed.
M&L for providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete including fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size on the top of the floor or the side of waist slab with suitable arrangement complete all as specified and directed. Note: Only weight of stainless steel members deemed to be considered for payment purpose.
Providing and fixing factory made uPVC glazed / wire mesh windows / doors comprising of lead free uPVC multi chambered frame, sash and mullion / coupler (wherever required) extruded profiles having minium wall thickness of 1.70mm for series R1 & R2 profiles and 2.10mm for R3 & R4 profiles confirming to EN:12608 in any shape, colour and design duly reinforced with galvanised mild steel section made of required shape and size as per specifications, uPVC extruded glazing beads, interlocks and inline sash adoptor (wherever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteneres of minimum 8mm dia with counter shunk head, comprising to matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS:1367-Part 1 to 14, plastic packers, plasteic caps and necessary stainless steel screws.
Profile frame, sash & mullion (if required) shall be mitred cut and fusion welded / mechanically jointed duly sealed at all corners including drilling holes for fixing hardware and drainage of water after fixing frame the gap between frame and adjucent finished wall shall be filled with weather proof silicon sealent over backer rod of approved size and quality, all complete as per approve drawing confirming to DSR specificatons & directions of GE complete all as specified and directed for the following:- Section of steel reinforcement and cross sections of UPVC profiles to be as per design approved by GE. Note: Wire mesh / glazing shall be measured and paid separately under relevant item.
(a) Casement door double panel with french (false) Mullion with zinc alloy (zamak) 3D hinges, muilti-point locking system with cylindrical, zinc alloy (zamak) powder coated handles on both sides : using R3 series with frame (55mm & above) x (50mm & above) & sash (55mm & above) x (85mm & above) & french (False) mullion (55mm and above) x (60mm & above) (height upto 2.5 metre).
(b) Casement cum fixed panel window having single casement panel at both ends & middle fixed panel with SS 304 friction hinges as per size and weight of sash, muilti-point locking system, zinc alloy (zamak) powder coated handles : using R2 series with frame (39mm & above) x (39mm & above) & sash (39mm & above) x (60mm & above) & mullion (39mm and above) x (60mm & above) (height upto 1.8 metre; each openable shutter upto 0.8 width).
(c) Fixed window / ventilator with mullion / transom : using R2 series with frame (39mm & above) x (39mm & above) & mullion (39mm and above) x (60mm & above) (height upto 1.2 metre).
S&F, only float glass panes of nominal thickness 5 mm (weight not less than 12.50 kg/sqm) complete all as specified and directed.
Dismantling existing unserviceable auditorium chairs of any size and description and making good to the surface of floor complete all as specified and directed.
S&F, new molis plus chairs venus I frame main PP Armrest, Manual Tip up, seat back cover, Aisle and Row number visibility groove of size 60.9 cm x 98.4cm x 65.4 cm matt finish Auditorium Chair complete all as specified and directed.
M&L for complete removal of existing treatment including washing, rubbing down and stopping etc., distembered wall surfaces and two coats of Lustre paint over a coat of primer including one coat wall care putty complete all as specified and directed.
S&F, curved urinal glass partition of 10mm thick of size 900mm x 450mm and fixed on walls with fitting accessories complete all as specified and directed.
S&F, fly proof stainless steel grade 301 wire guage with 0.5mm dia wire and 1.4mm wide aperture complete all as specified and directed.
AIR CONDITIONING Note for Sl item Nos. 115 to 152: Air conditioning works shall be got executed through specialist agency having minimum 05 years experience in execution of Air conditioning works / OEM. The agency shall be approved by GE. Dismantling of existing chiller system alongwith all the components including cooling tower, motor pumps, AHUs, HVAC Panel, pipelines etc and shifting it to MES Yard complete all as specified and directed.
Supply, installation, testing & commissioning WATER-COOLED DX TYPE SCROLL CHILLER UNIT (1W) - with ISEER complied & minimum 3 STAR rated, factory designed, pre-fabricated and floor-mounted hermetic scroll type water cooled chiller machine of Minimum 74 TR (2 x 37) capacity and complete with hermetic scroll compressors having independent refrigerant circuits & automatic stepless capacity control,
water-cooled S/T type condenser, S/T horizontal flooded type evaporator with MS shell and seamless copper tubes with elastomeric insulation, suitable numbers of herrmatically sealed Inverter compressor, unit mounted variable frequency drive (VFD) along with necessary drive arrangement, lubrication system as per manufacturer's design required for smooth and trouble-free operation of the chiller package, common base frame, interconnected copper refrigerant piping along with elastomeric insulation, fittings, valves, expansion valves and accessories to interconnect compressor, condenser, chiller and expansion valve, microprocessor based control panel comprising of controls including sensors and equipped with a keyboard, LCD touch screen min 7" access input system, protection and monitoring devices to perform control functions, wiring, vibration isolators,
gauge panel, automatic safety controls, flow switch at evaporator and condenser and ozone friendly, CFC-free refrigerant R-410A/407C complete as specified and directed by the Engineer-in-Charge. The chiller shall conform to the following requirements / specifications: [i] Chilled water inlet / outlet temperature: As per OEM to maintain inside temperature of 24 +/- 2 C. [ii] Evaporator fouling factor: 0.00010 ⁰Fft²hr/Btu. [iii] Evaporator side pressure drop: 5 m of H2O (maximum). [iv] Condenser water inlet / outlet temperature: 30/35 ˚C. [v] Condenser fouling factor: 0.00025 ⁰Fft²hr/Btu. [vii] Refrigerant (Ozone friendly type): R410A/R407C/Eco friendly gas not banned by HVAC industry. [viii] Test standard: In accordance with AHRI 550 / 590.
Supply, installation, testing & commissioning of FRP INDUCED DRAUGHT COOLING TOWER with Twin Cell FRP rectanguler shape, vertical, induced draught counter flow cooling tower of minimum 100 TR size (2 x 50) with uniform water distribution and optimal heat transfer, having tough Fiberglass Reinforced Plastic (FRP) casing of sufficient structural strength to withstand vibrations and wind velocity upto 60 m/s, FRP basin, rigid honeycomb type PVC fill of suitable thickness, SS sprinklers and non-clogging sprinkler pipes, FRP drift eliminator, energy efficient induced draught axial type fans with factory set and dynamically balanced blades pitch, IE3 TEFC squirrel cage induction motor, suitable for operation on 3-Ph, 415 V, 50 Hz AC supply with IP 65 protection for enclosure, conforming to IS 12615: 2018, inlet, outlet, drain and over-flow nozzle connections etc., complete with accessories as specified and directed.
Notes: Cost of necessary civil work viz. foundation, supporting structure etc., for placement of cooling tower shall be deemed to be included in quoted unit rate.
Supply, installation, testing & commissioning of double-skin type horizontal, floor-mounted, top / side discharge outdoor type air handling unit of the 32000 CFM capacities at 50 mm static pressure, Hollow profile, with air-tight casing using gaskets and self-adhesive tapes and 0.6 mm thick pre-coated outer skin and 0.6 mm thick GI inner skin, 25±2 mm thick double skin panel with pressure injected CFC & HCFC free PUF having 'k' value of 0.02 W/°C/m & density 40 kg/m³ belt driven or plug fans with backward curved impellers for high static pressure mounted on aluminium extruded side rail base frame, EU4 pre-filter of 4/6 rows DX type copper coils with anti-corrosion aluminium fins, suitable high efficiency (IE3) TEFC flameproof squirrel cage induction motor, electric step heater, PVC/nylon hinges & handles, view port and marine lamp, limit switch, SS-304 drain pan,
vibration isolators / rubber pads (minimum 1" thick) inspection windows / doors, mixing box and supply / return / fresh air openings fitted with aluminium volume control dampers complete all as specified and directed. The AHU shall comprise of the following: [a] Suitable SISW backward curved plug fan, dynamically balanced with AMCA certified blower. [b] Flame-proof foot mounted (B3 construction) 3-Phase squirrel cage induction motor 415 V ± 10%, 50 Hz ± 5%, combined variation ±10%, insulation class F, (for blower of AHU) of 11 kW capacity with temperature rise limited to class B, degree of protection IP 55, duty 51, ambient temperature 45ºC, conforming to IS:12615-2011, IS/IEC 60079-1:2007, IS:3682-1966 gas group II A, II B.
[c] Flexible connetion made with air tight ASTM E84 (Class I) polyester fire retardant cloth riveted on periphery of cloth with extruded aluminium 'L' angle flange as per fan size at discharge duct / plenum. [d] Washable type of 'EU4' filter (pre-filter, efficiency 90% down to 10 micron) and 'EU7' filters (Micro Vee filters, efficiency 99% down to 3 micron). [e] 4 / 6 rows deep DX type cooling coil section with 0.15 mm thick copper fins and 0.36 mm diameter copper tubes tested on 21 kg/cm², with SS sandwiched drain tray (a 350 mm service section between eliminator and heater is required). [f] Condensate drain pan fabricated from 18 gauge SS 304, powder coated and insulated with elastomeric insulation of suitable thickness.
[g] Heater banks of 36 KW consisting of strip heaters alongwith power and control wiring, electric starters, air stat, humidistat and any other control require to operate the heater bank and safety device. [h] AHU panel made out of 2.00 mm thick mild steel CRCA sheet duly powder coated in compartamentalised construction with incomer and outgoing feeders for AHU motor, 3-way valve actuator motor, fire damper actuator motor complete with required Variable Frequency Drive (VFD), relays, timers, contactors, PT, push buttons, switches, internal wiring etc.
[j] Variable Frequency Drive (VFD) with IP 55 enclosures and mains disconnect switch suitable for 11 kW and comprising of the following complete with accessories of Danfoss, Schneider, L&T, ABB or Fuji make: - (i) Built in dual 5% impedance DC link reactor (harmonic filters) on the positive and negative rails of the DC bus of the Variable Frequency Drive.
(ii) Built in EMC filters (Electro Magnetic Compatibility filters) for restriction of conducted emissions to comply with IEC-61800:3 (unrestricted distribution) : 2004 category C1 (50 meter). (iii) Three feedback PID controller having capability to simultaneously accept 3 feedback signals from temperature sensors or pressure sensors for process optimization and accordingly control the speed of the AHUs or pumps. (iv) Integral graphical keypad.
Supply, installation, testing & commissioning of monoblock, self-priming, single-stage centrifugal pump, capacity of minimum 3 HP and of suitable head and flow to match Chiller plant condensor flow and cooling tower capacity (as per OEM TDS), having cast iron casing, enclosed type dynamically balanced cast iron impeller, carbon steel pump shaft, gland packed sealing, deep groove ball bearings etc., with TEFC squirrel cage induction motor having class 'B' insulation, IE3 efficiency, conforming to IS-12615:2018 and suitable for operation on 3-Ph, 415 V±10%, 50 Hz AC supply, base plate, mounting channel frame, accessories and fittings viz. pressure gauges, thermometers, drains, coupling, coupling guard, vibration isolation arrangement by means of spring / rubber type mounting complete all as specified and directed.
Note: Necessary civil work foundation for placement of pump and pump accessories shall be deemed to be included in quoted unit rate.
S&F, set of strip heater bank of requisite 3 KW rating for full load for monsoon and winter heating to maintain desired temperature and humidity conditions complete all as specified and directed.
Supply, installation, balancing & commissioning of factory fabricated galvanized steel sheet metal (G.S.S.) round / rectangular ducting of following sheet thickness 18G having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports etc., as per approved drawings and conforming to the latest edition of IS:655-2006 & HVAC Duct Construction Standards - Metal and Flexible of SMACNA alongwith required scaffolding work to install the ducts at site complete all as specified and directed by Engineer-in-Charge.
Supply, installation, balancing & commissioning of factory fabricated galvanized steel sheet metal (G.S.S.) round / rectangular ducting of following sheet thickness 20 G having zinc coating of 120 g/m² total on both sides and complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, volume control dampers, hangers, supports etc., as per approved drawings and conforming to the latest edition of IS:655-2006 & HVAC Duct Construction Standards - Metal and Flexible of SMACNA alongwith required scaffolding work to install the ducts at site complete all as specified and directed by Engineer-in-Charge.
S&F, closed cell elastomeric 19mm nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20° C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/m³. The insulation material shall be FM (Factory Mutual) dust & fibre free. The aluminium foil shall be 12 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 sqmm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 complete all as specified and directed.
S&F, closed cell elastomeric 13mm nitrile rubber insulation with aluminum foil laminated on one side, having thermal conductivity not exceeding 0.037 W/mK at mean temperature of 20°C as per EN 12667, moisture diffusion resistance factor or ‘µ’ value of minimum 7,000 for base insulation material without the foil as per EN 12086, fire performance such that it passes Class 1 as per BS476 Part 7 for surface spread of flame and also fire performance of V0, HB as per UL 94, 1996, density without the foil between 40 to 55 kg/m³. The insulation material shall be FM (Factory Mutual) dust & fibre free. The aluminium foil shall be 12 microns thick and its weight shall be 193 gsm as per EN ISO 2286-2, tensile strength 90 N / 15 sqmm as per EN ISO 527-3 with elongation > 10% as per EN ISO 527-3 complete all as specified and directed.
S&F, open-cell engineered 25 mm thick nitrile rubber foam acoustic insulation having good sound absorption, damping and barrier properties, antimicrobial product protection, thermal conductivity not exceeding 0.047 W/mK at 20° C, conforming to EN 12667, density 140-180 kg/m³ and conforming to class 1 rating for surface spread of flame in accordance with BS 476 Part 7 & UL 94 (HB, V- 0). The acoustic insulation material shall be free of dust and fibre; it shall pass fungi / mould resistance as per DIN EN ISO 846 method A and bacterial resistance as per DIN EN ISO 846 method C and air erosion resistance test in accordance to ASTM Standard C 1071-05 without any laminate or covering (Section 12.7) from an independent accredited testing agency complete all as specified and directed.
S&F, Air Grill / Diffuser with damper of powder coated aluminium with aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed.
S&F, Air Grill / Diffuser with damper of powder coated aluminium without aluminium volume control dampers with anti smudge ring & removable core complete all as specified and directed.
S&F, GI construction volume control dampers lever operated type to be mounted on duct complete all as specified and directed.
Supply, erection, testing & commissioning of fusible link type fire damper as per UL555 complete all as specified and directed.
Supply, laying, fixing, testing & commissioning of 100mm NB condenser water piping including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators etc., including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories complete all as specified and directed.
Supply, laying, fixing, testing & commissioning of 125mm NB condenser water piping including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, drain valves, structural support, necessary clamps, vibration isolators etc., including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories complete all as specified and directed.
Notes for Sl item Nos. 130 & 131: [i] The pipe size 150 mm NB & below shall be MS 'C' class as per IS-1239 (Part-1) : 2004 & IS 1239 (Part-2) : 2011. [ii] The pipe size above 150 mm NB shall be welded black steel pipe heavy class as per IS-3589:2001. [iii] Minimum thickness of MS sheet for pipe size above 150 mm NB and upto 350 mm NB shall be 6.35 mm and it shall be 7 mm for pipe size 400 mm NB and above.
Supply, laying, fixing, testing & commissioning of copper refrigerant piping (sizes as per OEM approval) including necessary fittings viz. bends, tees, reducers, flanges, air purge valves, structural support, necessary clamps, vibration isolators etc., including painting and supporting / fixing the pipe in excavated trenches or on floor / wall / ceiling with clamps, hangers, angles, channels (using anchor fastners) with necessary accessories duly insulated with FM approved highly-flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of 25mm thickness with necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of 100mm NB water type PN 1.6 rated short pattern CI butterfly valve having Grade FG-200 CI body conforming to IS-210:2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI-410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI-125 with necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of 80mm NB water type PN 1.6 rated short pattern CI butterfly valve having Grade FG-200 CI body conforming to IS-210:2009, seat having EPDM rubber lining, CF 8 stainless steel disc, AISI-410 stainless steel stem, 2.4 MPa body test pressure & 1.6 MPa seat test pressure and standard flange end conforming to BS 10 Table D/E & ANSI B 16.1 CI-125 with necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of 80mm NB cast steel bolted cover Y-type strainer conforming to ASTM A- 216 Gr. WCB, AISI 304 screen with 1.2 mm diameter perforation, 16 kg/cm2 body test pressure & 20 kg/cm2 maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150 with necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of 100mm NB cast steel bolted cover Y-type strainer conforming to ASTM A- 216 Gr. WCB, AISI 304 screen with 1.2 mm diameter perforation, 16 kg/cm2 body test pressure & 20 kg/cm2 maximum working pressure and standard flange end conforming to BS 10 Table F / Class-150 with necessary accessories complete all as specified and directed.
Suply, installation, testing & commissioning of 80mm NB water type PN 1.6 rated swing check type valve (NRV), designed & tested as per IS:5312 (Part-2) : 1986, suitable to handle clear water having turbidity upto 5000 PPM having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection etc., with other necessary accessories complete all as specified and directed.
Suply, installation, testing & commissioning of 100mm NB water type PN 1.6 rated swing check type valve (NRV), designed & tested as per IS:5312 (Part-2) : 1986, suitable to handle clear water having turbidity upto 5000 PPM having CI body, door and diaphram, leaded tin bronze seat rings and flange drilling standard end connection etc., with other necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of electronic, self-balancing, pressure independent type dynamic balancing valve rated for minimum 25 bar working pressure with integrated 3-way modulating control valves in a single body and actuator capable of accepting upto 10 V DC and upto 20 mA electric signal and provide similar transduced feedback output to control system duly insulated with FM approved highly-flexible, closed-cell thermal insulation of elastomeric foam based on synthetic rubber (NBR) of apppropriate thickness laminated with 12 micron aluminium foil facing with reinforced glass scrim alongwith adhesives and other necessary accessories complete all as specified and directed. Notes: [i] Maximum close off pressure shall not be less than 6 bar for upto 50 mm valves. [ii] Maximum close off pressure shall not be less than 7 bar for 65 mm & above.
Supply, installation, testing & commissioning of precise balancing, double regulation type cast iron balancing valve 100 mm NB having FG 200 cast iron body conforming to IS:210-2009, copper alloy trim, stainless steel 2 Cr. 13 stem, 2.4 MPa body test pressure & 1.6 MPa maximum working pressure and standard flange ends with necessary accessories complete all as specified and directed.
Supply, installation, testing & commissioning of precise balancing, double regulation type cast iron balancing valve 80 mm NB having FG 200 cast iron body conforming to IS:210-2009, copper alloy trim, stainless steel 2 Cr. 13 stem, 2.4 MPa body test pressure & 1.6 MPa maximum working pressure and standard flange ends with necessary accessories complete all as specified and directed.
S&F, 6" dual scale (°F/°C), lower mount (radial), bimetal thernometer having 0.5 NPT process connection, Grade A accuracy class as per ASME B40.200, stem diameter 6.35 mm, laminated safety glass window, stainless steel 304 case, steam, process connection & joint, aluminium dial & pointer, IP67 protection, scale range 0-60°C with accessories complete as specified and directed.
S&F, 4" bourdon tube pressure gauge conforming to EN 837-1, having copper alloy process connection & pressure element, plastic black pointer & case, plastic crystal-clear window, snap-fitted in case, accuracy class 2.5, scale range 0-25 bar with accessories complete as specified and directed.
Supply & installation, rotational moulded polyethylene water storage tank of 5000 Litres capacity (triple layered ISI marked cylindrical vertical with closed top), hoisted and fixed in position on the roof or platform of plant room, connecting up pipes, securing access covers etc., complete all as specified and directed.
Supply, installation, commissioning & testing of factory made, CPRI type tested, indoor, cubical compartmental type "HVAC Panel" of suitable size, conforming to IEC 61439-1 & 2, IEC 61641, having both sides openable with hinged double doors & locking arrangement and IP 42 protection made out of 2.0 mm thick mild steel CRCA sheet, supported and fixed on structural frame of angle iron of suitable size, including earthing stud, labeling, painting to all internal & external exposed steel surfaces with powder coating paint (7 tank process), duly fixed in ground with PCC foundation 1:2:4 type B1, with danger notice plate of 1.6 mm thick mild steel sheet, vitreous enameled (white) with letters figures and conventional skull and bones in signal
red colour, suitable for 3-Phase 4 wire system, 500 V grade with necessary wiring, PVC sheathed stranded copper conductor of appropriate length & size including fixing lugs, bolts, screws etc., with accessories complete all as specified and directed. Make: CPRI approved panel builder the HVAC panel shall comprise of the following: Busbar Chamber: [i] 01 set (3L + N) of copper busbar of rated capacity 320 A, covered with PVC insulated sleeves including insulator, nuts, bolts etc., with complete connection.
Incoming: [i] 250 A, 415 V, Ics = 100% Icu = 36 kA, 50 Hz FP MCCB, conforming to IEC:60947-2, having thermal magnetic based trip unit, adjustable overload setting (0.7 - 1 X In), adjustable short-circuit setting (5 - 10 X Ir), adjustable neutral protection (N, N/2, OFF), front indication LEDs (Ready, Overload and pre-alarm & Overload) - 01 No. [ii] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs, Onhrs & interupts.
Outgoing: [i] 80 A, 415 V, Ics = Icu = 16 kA, conforming to IEC:60947-2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD) - 03 Nos. [for chillers]. [ii] 63 A, 415 V, Ics = Icu = 16 kA, conforming to IEC 60947-2, 50 Hz, FP MCCB with adjustable thermal settings (0.70 - 1 X In) & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD) - 01 No. [for AHU].
[iii] 32 A, 415 V, Ics = Icu = 16 kA, conforming to IEC:60947-2, 50 Hz, FP MCCB with adjustable thermal settings & fixed magnetic settings with compression lug connectors and thermal magnetic trip unit (TMD) - 08 Nos. [for chilled water supply pump, condenser water supply pump & cooling tower]. [iv] LED phase indicators (Red, Yellow, Blue) - 12 sets. [v] Cl 1.0 multi-function meter capable of measuring V, A, F, PF, W/VA, Wh/VAh, Runhrs, Onhrs & interupts - 12 Nos. [vi] DOL starter suitable for chilled water circulation pump [3 HP] - 03 Nos. [vii] DOL starter suitable for condenser water pump [3 HP] - 03 Nos. [viii] DOL starter suitable for cooling tower motor [2 HP] - 02 Nos.
M&L for 4 core 16 mm2 (for AHU) ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS:7098 (Part 1) - 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS:8130-1984, PVC inner sheath, single armouring of galvanized steel strip / wire and PVC type ST-2 outer sheath conforming to IS:5831-1984, including termination complete as specified and directed.
M&L for 4 core 4 mm2 (for pumps) ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS:7098 (Part 1) - 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS:8130-1984, PVC inner sheath, single armouring of galvanized steel strip / wire and PVC type ST-2 outer sheath conforming to IS:5831-1984, including termination complete as specified and directed.
M&L for 4 core 10 mm2 (for cooling tower) ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS:7098 (Part 1) - 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS:8130-1984, PVC inner sheath, single armouring of galvanized steel strip / wire and PVC type ST-2 outer sheath conforming to IS:5831-1984, including termination complete as specified and directed.
M&L for 3.5 core 35 mm2 (for chillers) ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS:7098 (Part 1) - 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS:8130-1984, PVC inner sheath, single armouring of galvanized steel strip / wire and PVC type ST-2 outer sheath conforming to IS:5831-1984, including termination complete as specified and directed.
M&L for 2 core 1.5 mm2 (for chillers interlocking) ISI marked 1.1 kV grade aluminium conductor, XLPE insulated armoured cables, conforming to IS:7098 (Part 1) - 1988 having stranded aluminium compact shaped conductor as per Cl. 2, IS:8130-1984, PVC inner sheath, single armouring of galvanized steel strip / wire and PVC type ST-2 outer sheath conforming to IS:5831-1984, including termination complete as specified and directed.
M&L for laying foundation to equipment such as package chillers AHUS, HWG LT panel board, pump sets, cooling tower, pipeline, common headers etc., including any other masonary work, excavation and earth work for pipe work, cable work, foundation support etc., and opening in walls for duct work, grills / diffusers / blanking plates etc., finishing of openings including painting / white wash work to match the interior decoration existing work complete all as specified and directed.
M&L for earthing complete with 60cm x 60cm x 6mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with GI strip of size 32 x 6mm as earthing lead with bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified including testing on completion including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6) type C1 in chamber, precast 50 mm thick in cement 1:2:4, type B1 with CI frame with cover, 20mm dia bore light grade GI watering pipe funnel etc fixing of GI Pipe 40 mm bore protection for earthing strip from earth pit to test point complete & making connection complete all as specified and directed. Note: Earthing lead beyound 7.5 m will be measured and paid seperately under relevant item.
M&L for earthing complete with GI earth plate electrode 60cm x 60cm x 6mm thick burried directly in ground (earth pit not less than 2.25m deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level connected to GI strip 25 x 4mm thick as earthing leads by means of bolt, nut, check nuts and washers galvanised iron or steel all as shown in elctrical plate No. 5 of SSR Part I connected to earthing test point or as specified or indicated and testing on completion including excavation and earth work, PCC pit with RCC cover having suitable handle, 32mm bore GI medium grade watering pipe with funel and wire mesh, 15 mm dia GI light grade protection pipe complete all as specified and directed. Note: Earthing lead beyound 7.5 m will be measured and paid seperately under relevant item.
S&F, GI strip 25mm x 4 mm with saddles & fixing screws for earth continuity conductor fixed on PCC block with all necessary fixing arrangement for lightning protection complete all as specified and directed.
S&F, air termination single pointed aluminium rod of 12mm dia, 300mm long fixed with 02 Nos suitable sized nuts, bolts & washers including making good the disturbed surfaces complete all as specified and directed.
S&F in repair of test point terminal block made of gun metal or phosphorous Bronze 75mm x 75mm x 25 mm dilled and screwed including 03 Nos 8mm dia 50 mm long hex head screws rectangular opening at top and bottom for entry of down earth strip, fixing screws and bolts for mounting on wall complete all as specified and directed.
S&F, suitable sized heavy duty bridge / post porcelain / mini busbar insulator on wall / roof with suitable size of PVC plugs / gutties, screws for fixing aluminium / GI strip including making good the disturbed surfaces complete all as specified and directed.
M&L for jointing copper / G.I. tape (with another copper / G I tape, base of the finial or any other metallic object) by riveting / nut bolting / sweating and soldering as required complete all as specified and directed.
M&L for PCC in foundation for filling of road in plinth protection as in bed plates for fixing of aluminum strip in PCC 1:3:6, type C1 with 20 mm graded stone aggregate complete all as specified and directed.
M&L for GI pipe light grade 32 mm dia for fixing of air termination single pointed aluminum rod of 12mm dia, 300mm long on the roof of builings for effective lightning protection system including PCC for fixing complete to the satisfaction complete all as specified and directed.
S&F, LED 40W decorative post top lantern for 360 degree indirect light, made in cast aluminium with decorative opal polycarbonate diffuser with IP 65 protection, resistance to impact and corrosion, glare free and better uniformity complete all as specified and directed.
Supply, laying & testing, cable XLPE insulated heavy duty electric cables with aluminium conductor 1100 volts grade cross sectional area 6 Sqmm, 2 core cable connection lugs, glands, jointing materials etc laid on wall, floors, roof, ducts and fixing using clamps, saddle complete all as specified and directed.
Supply & laying, 40mm outside dia double wall corrugated pipe (DWC) of HDPE ISI mark for enclosing cable below ground / surface to a required depth including suitable size couplers for jointing of pipe as per site requirement complete all as specified and directed.
Taking down carefully unserviceable sub main wiring including conduit from ground complete all as specified and directed.
Taking down unserviceable DBs/MCB SP/SPN/isolator of any rating & size carefully disconnecting and making good disturbed surfaces complete all as specified and directed.
Taking down carefully Copper/ aluminium point wiring light, Fan, socket or power complete including fixture & fitting such as switches, sockets or power socket complete fitting bracket holder, boards, and making good disturbed surfaces of wall and ceiling etc complete all as specified and directed.
M&L for wiring of light point / fan point / exhaust fan point / call bell point with 2 x 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable complete all as specified and directed.
All as per Sl item No. 167 above but 6 Amps socket wiring alongwith earth wire with FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for 2 x 1.5 sq. mm + 1 x 1.5 sq. mm earth wire.
M&L for wiring of 16 Amps power socket wiring alongwith earth wire with FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required for 2 x 4.0 sq. mm + 1 x 4.0 sq. mm earth wire complete all as specified and directed.
S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections as required complete all as specified and directed.
S&F, suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections as required complete all as specified and directed.
S&F, 25mm size of medium class PVC conduit alongwith accessories in surface / recess including cutting the wall and making good the same in case of recessed conduit as required complete all as specified and directed.
S&F, call bell / buzzer suitable for single phase, 230 V, complete all as specified and directed.
S&F, Bell push modular type SP 6 Amps complete all as specified and directed.
S&F, fan regulator electronic 2 modular type volts AC 50 HZ, 300 Watts, 4 step complete all as specified and directed.
S&F, ceiling rose, 3 phase, PVC polycarbonate, insulated body ISI marked complete all as specified and directed.
S&F, 2 feet 10 watts basic all purpose surface and wall mounted 2 feet LED batten with aluminum housing & integrated electronic driver including all fixing accessories and connected with 3 core white isulated copper cable to the ceiling rose complete all as specified and directed.
S&F, LED flat panel 15W aesthetically designed 1 x 1 LED flat panel for surface mounting which provides soft-light and glare free symmetrical illumination complete all as specified and directed.
S&F, 4 feet 18/20 watts basic all purpose surface and wall mounted 4 feet LED batten with aluminum housing & integrated electronic driver including all fixing accessories and connected with 3 core white isulated copper cable to the ceiling rose complete all as specified and directed.
S&F, surface mounted spot light 5 watts in matt finish for premium aesthetics complete all as specified and directed.
S&F, LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including therma management in multiple optics complete all as specified and directed.
S&F, 30W new generation, energy saving, aesthetically designed, recessed mounted down light pressure die-cast aluminum heat sink & high efficiency long life COB LED mounted on MCPCB with high efficacy of used for enhanced lumen output complete all as specified and directed.
S&F, energy saving, environment friendly & robust highbay LED luminaire with high efficacy (100lm/W) with toughened glass complete of capacity 100Watts including driver and all other accesories and fixing arrangements complete all as specified and directed.
S&F, auditorium exit / signage LED light fittings complete all as specified and directed.
S&F, auditorium steps lights with numbers anti glare with required colour complete all as specified and directed.
Taking down carefully existing ceiling / exhaust fan and cleaning the surface of fan keep in safe custody and refix the same without any damage complete all as specified and directed.
S&F, vertical MCCB DB TPN 6 way vertical type with sheet steel enslosure acrylic door fitted with DIN channel TP 200 Amps copper bus bar neutral earth link suitable for TP/SP MCBs as out going 3 Phase 415 V complete all as specified and directed.
S&F, sheet metal enclosure MCB DB TPN double door 4 way suitable for 415 V with 200 Amps rated bus bar including flushed on walls and making good disturbed surfaces complete all as specified and directed.
S&F, single pole and neutral, sheet steel, MCB distribution board double door 6 way, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing complete all as specified and directed.
S&F, single pole and neutral, sheet steel, MCB distribution board double door 8 way, 240 V on surface / recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing complete all as specified and directed.
S&F, MCCB triple pole, 415 volts, 63 Ampere, rupturing capacity 16 KA complete all as specified and directed.
S&F, MCB TPN 32A 415V 'C' curve with 10kA breaking capacity with ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed.
S&F, MCB TP 32A 415V 'C' curve with 10kA breaking capacity with ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed.
S&F, MCB SPN 20A 240V 'C' curve with 10kA breaking capacity with ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed.
S&F, MCB SP 5A-32 A 240V 'C' curve with 10kA breaking capacity with ISI marked as per IS/IEC 60898-1 2002 complete all as specified and directed.
S&F, DP sheet steel enclosure on surface / recess along with 25/32 A 240 V 'C' curve DP MCB complete with connections, testing and commissioning complete all as specified and directed.
M&L for wiring for circuit / submain wiring alongwith earth wire with 2 x 1.5 sqmm + 1 x 1.5 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.
M&L for wiring for circuit / submain wiring alongwith earth wire with 2 x 2.5 sqmm + 1 x 2.5 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.
M&L for wiring for circuit / submain wiring alongwith earth wire with 2 x 4.0 sqmm + 1 x 4.0 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.
M&L for wiring for circuit / submain wiring alongwith earth wire with 4 x 6.0 sqmm + 2 x 6.0 sqmm of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required complete all as specified and directed.
Earthing with G.I. earth plate 600 mm x 600 mm x 6 mm thick including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long with charcoal / coke and salt as required complete all as specified and directed.
Supplying & laying, 6 SWG G.I. wire at 0.50 metre below ground level for conductor earth electrode, including connection / termination with GI thimble as required complete all as specified and directed.
S&F, 32 mm dia 2.00 metres long G.I. pipe (light grade) bracket for mounting of LED street light fitting on pole including bending the pipe to the required shape, 02 Nos 40 mm x 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint as required complete all as specified and directed.
S&F, dimmer pack suitable for auditorium lighting complete with all accories complete all as specified and directed.
Dismantling the old unserviceable LT panel board and fabrication, supply, installation commisioning of indoor electrical panel of cubical construction, floor mounted type, fabricated out of 2.00 mm thick CRCA sheet for intaernal and compartments with hinged locable doors, dust & vermin proof, powder coated of approved shade of 7 tank tretment process, cable interconnections FRLS copper conductors with following incoming and outgoing switch gears, 415 volts, 50 Hz AC complete all as specified and directed. Incoming: a) LED/Neon indicator bulb in RYB colour - 01 Set.
b) 04 Nos aluminium bus bar 250 Amps with chamber. c) Digital multi function meter for showing Amps (upto 200 Amps) and Voltage (upto 500 voltage) with suitable CT & PT. d) Onload Changeover switch 125 Amps, 415 V, Thermal Magnetic O/L & S/C protection, 125A with breaking capacity 25 KA - 01 No. Out going: e) MCCB 4 Pole, 415 V, thermal magnetic O/L & S/C protection, 63-100 A with breaking capacity 16 KA - 02 Nos. f) MCB 4 Pole, 415 V, 40 A - 01 No.
Shree Ayyappa Engineering (BID ID -3488679)
S G Enterprises (BID ID -3488254)
Shri Sant Cosntruction (BID ID -3488861)
M/s S. R. Constructions (BID ID -3488578)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.50 MB
85332_Tender.pdf
Tender Documents • 1.90 MB
BOQ_828005.xls
BOQ • 14.13 MB
Download all tender documents and submit your bid