| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.6 LAccepted-AOC 640 MAIN ROAD BABINA CANTT JHANSI UP 284401 | JHANSI | JHANSI | UP | 284401 | L1 | Accepted-AOC Being a L1 bidder | |
| 2 | L2₹29.5 L+₹1.8 L (6.35%)Rejected-Finance 1308 MAIN ROAD BABINACANTT DIST JHANSI 284 401 | BABINA | JHANSI | UTTAR PRADESH | 284401 | L2 | Rejected-Finance Other than
lowest
bidder | |
| 3 | L3₹33.9 L+₹6.1 L (22.1%)Rejected-Finance | L3 | Rejected-Finance Other than
lowest
bidder |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
9 Dec 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE BABINA
GE BABINA CANTT 284401
PROVN OF CERTAIN SPECIAL REPAIR WORK AND MINOR WORK UNDER AGE B/R-I AND AGE E/M AT GE BABIBA CANTT
2023_MES_627312_1
8175/E8
Open Tender
Civil Works
Item Rate
180 days
GE BABINA
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE BABINA
₹91,000
Yes
17 Feb 2024
7 Nov 2023
11 Dec 2023
7 Nov 2023
9 Dec 2023
24 Nov 2023
Amount
Demolition of PCC/lime concrete (Other than Ground flooors) terracing including felt in any description and in any position over roof etc complete all as specified and as directed by the Engineer-in-Charge.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in padding over roof finished and laid to required slope complete all as specified and as directed.
M&L, roughening surfaces of old concrete roof by picking ,sweeping clean and washing down with water to remove dust etc and applying a coat of cement slurry @ 3 Kg per Sqm complete all as specified and directed.
M&L for P.C.C 1:2:4 type B-0 using 12.5 mm graded stone aggregate as in coping or roof kerbs on roof chamfered on edge including troweling slightly complete all as specified and as directed.
M&L for 10 mm thick rendering in cement mortar 1:4 on concrete surfaces when concrete is stil green finished even and fair including mixing of water proofing compound as per manufacturer instruction etc complete all as specified and as directed. Note :- Water proofing compound shall be measured separately as supply only in item no 05
Supply only integral water proofing compound complete all as specified and as directed.
M&L for applying water proofing treatment with the following:- (a) First coat of bitumen primer conforming to IS-3384 @ 0.3Kg / sqm to be applied on prepared surface till the surface is properly impregnated. (b) The water proofing memberne minimum weight 3kg/sqm and minimum 3mm thick reinforced with polyestered non woven fabric (weight not less then 160gms/sqm) shall be laid on the primed surface by torch application method as per manufactured instruction including Aluminium paint complete as spd. (c) All joints and change in direction should be curved with cement mortar (1:3) mixed with SBR latex @ 200ml per bag on cement and cured well before laying of membrane.
Taking up or down existing steel water tubing 15 mm bore and connections including cleaning for refixing or removal to store complete all as specified and as dircted
Taking up or down existing steel water tubing 20 mm bore and connections including cleaning for refixing or removal to store complete all as specified and as dircted
Supply and fixing, jointing and testing galvanised iron tubing 15 mm bore medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor etc with new fittings complete all as specified and directed.
Supply and fixing, jointing and testing galvanised iron tubing 20 mm bore medium grade with all fittings such as bends, elbows sockets, reduces etc and fixed to wall, ceiling or laid in floor etc with new fittings complete all as specified and directed.
Fixing only old steel tubing 15mm dia and connections obtained from taken down against item No 3 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings etc complete all as specified and as directed.
Fixing only old steel tubing 20mm dia and connections obtained from taking down against item No 4 herein before in new or old position fixed to wall, ceiling or laid in floor with new fittings etc complete all as specified and as directed.
Cutting chases, pinning in, making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps, cills, sunshades, shelves, lintels etc., and cutting chases for concealed water tubing or concealed conduit wiring, etc., and making good, cuttingexceeding 10 cm but not exceeding 20 cm girth in brick walls complete all as specified and as directed.
S & F 1000ltr rotational moulded polyethylene water storage tanks, (cylindrical vertical with closed top) hoisted and fixed in position, all as specified in SSR part I-1991 including 20 mm dia GI pipe light grade washout pipe 450 mm long with plug and 20 mm dia GI pipe light grade over flow pipe 600 mm long with fitting and dismantling of existing unserviceable tank and removing from site, complete all as specified and directed.
S&F 20mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minium weight 210 gms ), complete all as specified and directed
S & F in repair 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
S & F 20mm dia Gun metal gate valve with iron wheel head, screwed both ends for iron pipe complete all as specified and as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and as directed.
M&L for Vitrified ceramic tiles 10mm thick (square/rectangular) polished area of each tile not exceeding 0.36 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc including 15 mm screed bed with CM(1:4) and 25 mm thick PCC(1:2:4)type B0complete all as specified and directed.
M&L for non skid coloured joint free ceramic tiles 7 to 8 mm thick (square / rectengular) area of each tile exceeding 0.11sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc including 15 mm screed bed with CM(1:4) and 25 mm thick PCC(1:2:4)type B0 complete all as specified and as directed.
M&L for vitrified ceramic tiles 10 mm thick (square / rectangular) polished area of each tile exceeding 0.18 sqm but not exc 0.36 sqm, in Vertical surfaces such as skirting, dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match to floor etc and including rendering 10mm thick on fair faces of wall or conc surfaces in CM 1:4 finished rough for wall tiling etccomplete all as specified and as directed
M&L for joint free glazed coloured tiles 350x250x7mm/450x350x7mm thick for work on vertical surface, set & jointed in cement slurry and pointed in white or coloured cement to match etc including rendering 10mm thick on fair faces of wall or conc surfaces in CM 1:4 finished rough for wall tiling complete all as specified and as directed
M&L for 20mm thick Granite (of any type) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms and like including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over 15 mm thick in CM(1:6) etc complete.
Demolition of PCC in any description and in any position etc complete all as specified at site complete all as specified and as directed
M&L for 75mm thick cement concrete type C-1, 1:3:6 (20mm graded aggregate) as in plinth protection finished even and smooth without using extra cement complete all as specified and directed
M&L PCC 1:4:8 type D2 using 40mm graded stone agg as in foundation, filling and mass concrete, Sub base/flooring complete all as specified and directed.
M&L for sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for 60 mm thickness M-35 Grade , machine pressed precast concrete Inter locking paver blocks any shape & size with grey cement and pigment conforming to IS-15658-2006 laid dry over sand cushion complete all as specified and directed. Note:-Sand cushion shall be measured and paid separately
M&L for chequered tiles (Cement) 30cm X 30cm x 25mm set and jointed and pointed in neat cement slurry in floor with grey cement and pigment over & including 20mm thick screed bed in CM (1:6) Complete all as specified and directed.
Demolition of Brick work or stone/ boulder masonry, built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles etc complete all as specified and as directed
M & L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cm (1:6) to raise the hight of brick wall complete all as specified and as directed.
M&L, Brick work with sub class ;B; bricks old size half brick thickstraight or covered on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
Taking down cement plaster on brick or stone wall including raking out joints, hocking for key scrubbing down with water etc complete all as specified and as directed.
M&L for rendering 10mm thick on fair faces of wall even and smooth finish without using extra cement on conc/brick surfaces in CM 1:6, complete all as specified and as directed
M&L for rendering 15mm thick on fair faces of wall even and smooth finish without using extra cement on conc/brick surfaces in CM 1:4, complete all as specified and as directed
M & L for Preparation of new plastered surfaceof wall and applying two coat of OBD over a coat of putty complete all as specified and as directed.
M & L for preparation of new plastered surface of wall and applying two coats of cement base paint on external wall surface over a coat of alkali resistant primer complete all as specified and as directed.
M & L for preparation of new plastered surface and applying three coat of white wash on ceiling complete all as specified and as directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) exe 1.5 Sqm but n exc 4 Sqm each etc complete all as specified and as directed
Taking down chowkhat or frames with shutters (without taking off shutters from the frame) not exe 1.5 Sqm each complete all as specified and as directed.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top & bottom rails MS frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20 mm width stuck in side with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail and bottom rail,paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement all as directed and specified by Engineer-in-Charge.
S & F solid PVC door frame of size 50 mm x 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS Square tube etc complete complete all as specified and as directed.
S&F aluminum anodized barrel tower bolts of extruded section & fixed 150 mm long etc complete all as specified and as directed
S&F aluminum handles cast type anodized 150 mm size etc complete all as specified and as directed
S&F but hinges extruded aluminium alloy with galvanised mild steel hing pin, anodised and fixed, type C-21 100 mm size in toilet for PVC doors etc complete all as specified and as directed.
S&F 300 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast- aluminium alloy complete all as specified and as directed.
S&F Pressed steel frames for doors(105x60) mm with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc., complete as specified, supplied and fixed etc complete all as specified and as directed.
Cutting holes in brick walls built in cement mortar for inserting hold fasts and making good dismantled portion in CM 1:3 or cement conc 1:2:4 type B1 as required exc half brick but not exc full brick wall complete all as specified and as directed.
M&L PCC 1:3:6 type C-1 (using 20mm graded stone aggt) as in filling in holes of hold fasts and back filling of chowkats complete all as specified and directed.
S&F of 35mm thick 2nd class Hard wood paneled door shutter factory made (two panel) with lock rail andpanel of 9mm thick BWP commercial ply wood, the size of rail and stile is as per IS 1003 (Part-I), Kiln seasoned and chemically pressure treated complete all as specified and as directed.
M&L for preparation new wooden surface of any description not otherwise described over 10 cm width or girth and applying two coat synthetic enamel paint over one coat of pink primer etc complete all as specified and as directed
S&F in repairs Vitreous chine wash down water closet pan(padestal pattern), white (EWC) including plastic seat of same colour of Wc, closed pattern with flat bottom, and cover mild steel chromium plated hinging device complete all as specified and as directed.
S & F in repair 10 ltrs capacity PVC low level flushing cistern sleek plus single flush of colour star white Make :- Hindwar with inlet, float valve and handle with 32 mm dia PVC pipe 600 mm long complete all as specified and as directed.
S&F wash hand basin counter top, size 480x400x150mm brand cera, cat no S 2020145 or equivalent, including CP coupling and waste pipe, including ,cutting of granite shelf complete all as specified and directed.
S & F in repair Vitreous China urinal, half stall type, (excluding flushing cistern, flush pipe and waste pipe) complete all as specified and directed.
S&F in repair PVC connections 15mm size with PTMT nuts of length 450mm etc complete all as specified and as directed.
S&F in repair 15mm bore cast copper alloy chromium plated angle cock with flange complete all as specified and as directed.
S&F in repair 15mm bore fancy type chromium plated bib cock long body with flange etc complete all as specified and as directed.
S&F 15mm bore fancy type chromium plated bib cock long body with flange etc complete all as specified and as directed.
S&F brass CP mixer 15mm dia bore mixing hot & cold water for wash hand basin screwed down for iron pipe and fixed all as directed.
S&F in repair PVC floor trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S&F PVC floor trap outlet dia 75mm with grating including jointing to waste pipe fixed in cement concrete type B1 (1:2:4) complete all as specified and as directed.
S & F CP Towel ring complete all as specified and directed
S&F stainless steel kitchen plate rack overall size 900mm x 900mmx 250mm make out of 0.80mm thick stainless steel sheet etc complete all as specified and as directed.
S&F stainless steel kitchen plate rack overall size 900mm x 750mm x 250mm make out of 0.80mm thick stainless steel sheet etc complete all as specified and as directed.
S&F in repair stainless steel sink with drainage board 1.00mm thick for kitchen or laboretory with plug, waste pipe, coupling, washers also incl cantilever cast iron brackets connecting union etc, overall size 915x460mm with bowl size 410x330x160mm complete all as specified and as directed.
S&F in repair 25 mm dia chromium plate curtain rod with CP brackets and knobs at both end as per sample approved by Engineer-in-charge.
Demolition and breaking up drain pipes (Salt glazed ware, AC/PVC/CI or Reinforced concrete) set in cement mortar in floors or wall in 100mm dia meter complete all as specified and as directed.
S &F 110mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall and complete all as specified and directed.
S &F 75mm dia PVC (SWR) pipes single socketed, in any length with rubber ring joints laid in trenches or in floors or wall and complete all as specified and directed.
S&F PVC (SWR) bends any radius 110mm bore complete all as specified and directed.
S&F PVC (SWR) bends any radius 75mm bore complete all as specified and directed.
S&F PVC (SWR) junction single, (single T) equal or unequal 110mm bore with access door complete all as specified and directed.
S&F PVC (SWR) vent cowl 110mm bore complete all as specified and directed.
S&F MS chromium plated peg set of five fixing with screw to wall complete all as specified and as directed.
M&L for 100mm internal dia Salt-glazed stoneware drain pipes laid in trenches and joints complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) in concrete bed to drain pipes 100mm dia pipe including packing under, and hunching against the side of pipe after they are laid and tested complete all as specified and as directed.
Excavation in trenches not exc 1.5m wide and n. exc 1.5m in depth for foundation etc not exc 10 Sqm on plan and not exc 1.5m in depth and getting out in any type of soil complete all as specified and as directed.
M&L returning filling in including spreading levelling, watering and well ramming in layers n.exc. 25mm in any type of soil complete all as specified and as directed.
Removing excavated at a level n.exc 50m and deposited where directed at a level n exc 1.5m above the starting point complete all as specified and as directed.
Taking down wall panelling and similar work etc complete all as specified and directed
S&F for Solid PVC Wall Lining consisting of 5mm thick Plain colour PVC sheet inclusive of solvent cement and fixing at site on 5mm thick PVC sheet fillet of width 35mm for wall paneling inclusive of fixing on to wall to make PVC Frame as per specifications and drawing all as specified and directed.
S&F in repair false ceiling with 9-9.5 mm thick gypsum board tiles laminated with white PVC film on face side & metalized polyster film (Aluminium foil) on the back side with all four edges sealed with PVC film of size 600 x 600 mm (595 X 595 mm) fixed with clips & screws including anodised aluminium snap grid frame work for false ceiling of Tee/Angle of weight not less than 300 gm per RM with slot for fixing including necessary suspender of flat iron or 4 mm dia bars of required length fixed in purlin of roof not exceeding 1.20 m both ways including all accessories required for suspending ceiling work and gypsum board complete all as specified and as directed by the Engineer-in-Charge.
Dismantling of Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern in roof coverings complete all as specified and as directed by the Engineer-in-Charge.
S & F Pre painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strngth of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screw complete all as specified and as directed by the Engineer-in-Charge.
S & F MS steel work in tubular trusses and tubular posts, purlin including special shaped washers etc., complete using ERW or induction butt welded tubes conforming to I.S.I 1161-1998 Grade St-240 with one shop coat of zinc chromate primer paint complete all as specified and as directed by the Engineer-in-Charge.
M&L, preparing for new steel surfaces and applying two coats of synthetic enamel paint over one coat of red oxide primer over 10 cm width or girth complete all as specified and as directed.
M & L for complete removal of existing treatment from surface of wall complete all as specified and as directed by the Engineer-in-Charge
M & L for applying one coat of putty as per manufacturer instruction complete all as specified and as directed by the Engineer-in-Charge
M & L for applying two coat of oil bound distemper including preparation of surfaces complete all as specified and as directed by the Engineer-in-Charge
M&L Preparing old decorated surfaces of wall and applying two coats cement base paint complete all as specified and as directed.
M&L, Preparing old plastered/unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and directed.
M/L for brick work with kiln burnt bricks built in cm (1:4) using sub class 'B' bricks of compressive strength not less than 35 Kg/Sqcm straight or curved on plan exceeding 6 mtr mean radius with old size bricks all shown on drawing complete all as specified and as directed by the Engineer-in-Charge.
M & L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 m mean radius built in cement mortar (1:4) but except bricks (Brick shall be obtained from demolition. Unit rate for cleaning of old bricks shall be included in this item).
Demolition of un-reinforced cement concrete in ground floors and pavings not exceeding 15 cm thickness, (Below or above ground level) and disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 M as directed by the Engineer in Charge.
M & L for cement concrete 1:3:6 type C2 (using 40 mm graded stone aggregate) as in surface channels, drains and manhole foundation etc complete all as specified and as directed by the Engineer-in-Charge.
M&L, for extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
M&L, for Add or deduct for each 25 mm girth or part thereof over or under 30cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi- tred/stopped ends etc complete all as specified and directed.
Demolition of reinforced cement Concrete of any description and in any position disposal of unserviceable materials, debris and rubbish to a distance not exceeding 100 m as directed by the Engineer in Charge. (Reinforcement shall be cut as required to facilitate demolition).
M & L for precast reinforced cement concrete (1:2:4), type B-1 (using 20 mm graded stone aggregate) as in cover slabs (for drain etc) and similar articles with plain faces and set in cement mortar (1:4) complete all as specified and as directed by the Engineer-in-Charge.
M & L for mild steel TMT bars 10 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
M & L for mild steel TMT bars 6 to 8mm dia., cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and as directed by the Engineer-in-Charge.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil complete all as specified and directed.
Use and waste of formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work;not exceeding 200mm thick, rough finish complete all as specified and as directed.
Use and waste of formwork to beams, lintel band/beam, shelves rough finish work complete all as specified and as directed.
Use and waste of formwork to edges of concrete in roof, chajja etc exc 10cm and n exc 20cm wide complete all as specified and as directed.
M&L for RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate ) as in Beams, cantilevers,bressummers, lintels over 1.5m span complete all as specified and as directed.
M&L for RCC 1:1.5:3 type A1 (using 20mm graded stone aggregate ) as in Slabs supported on walls,beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed.
M&L for hardcore of gauge of brocken stone or boulder n exc. 63mm, deposited, spread and levelled in layers n exc.15cm thick, watered and rammed to a true surface complete all as specified and directed.
M&L for moorum/red bajri filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed by Engr-in-charge.
M&L for rendering 5mm thick on ceiling surfaces and finish even and smooth finish without using extra cement in CM 1:3 complete all as specified and as directed
M&L for preparation of new plastered surfaces of wall and applying two coats of oil bound distemper over a coat of alkali registance primer complete all as specified and directed by Engr-in-charge.
M&L for preparation of new plastered surfaces of wall and applying two coats of cement base paint over a coat of alkali registance primer complete all as specified and directed by Engr-in-charge.
M&L for 18/19mm thick prelaminated particle board, exterior grade, prelaminated one side with decorative choice lamination & other side balancing white lamination, fixed with screws to timber frame work complete all as specified and directed by Engr-in-charge.
M&L for 12mm thick plywood, grade BWR,type BB, fixed with screws to timber frame work complete all as specified and directed by Engr-in-charge.
M&L for 19mm cover fillet of external teak wood lipping 6mm thick fixed with nail complete all as specified and directed by Engr-in-charge.
M&L for Hasp and staple, safety type, aluminium anodised with mild steel hinge pin including bolt to hinge plate and fixed with screws complete all as specified and directed by Engr-in-charge.
M&L for 40mm dia, cupboard knobs fixed with nut, screw and washer of mild steel, bright finished complete all as specified and directed by Engr-in-charge.
S & F continuous (piano) hinges,mild steel, bright finish or electrogalvanised, width of flap(when open) 30mm complete all as specified and directed by Engr-in-charge.
S&F 35mm thick flush shutters,factory made, solid core construction, with block board core and plywood face panels, with decorative face veneers on both faces with lipping to match complete all as specified and directed by Engr-in-charge.
S&F factory made fabricated 35mm thick 2nd class hard wood Glazed and skeleton shutters , open rebated and prepared to receive glass, gauze, etc. (without sash bars), edges of framing plain, chamfered or rounded, fitted with cut and mitred beads for securing glass, etc. sizes of members of shutters as specified in SSR Part I, Section 8, clause 8.20 (a) fitted to chowkhats complete all as specified and as directed by the Engr-in-Charge. complete all as specified and directed by Engr-in-charge.
M&L for 2nd class hard wood for plain, solid, straight chowkats and frames for doors, wondows, ventilators etc. wrough, framed rebated on the solid, rounded or chamfered, put together with glue pinned at joints and fixed in position complete all as specified and as directed.
S&F galvanised mild steel wire cloth 0.63 mm nominal dia of wire and average width of apperture 1.40mm and fixed with stainless steel staples in steel/wooden /aluminium frames complete all as specified and as directed by the Engr-in-Charge.
S&F 3mm thick Sheet glass, ordinary quality and glazing with oil putty in square n.exe 0.50 Sqm in each pane complete all as specified and as directed.
S&F PVC waste pipe with 32mm bore and 65Cm long with cap complete all as specified and directed by Engr-in-charge.
Taking down carefully unserviceable aluminium point wiring (light, fan, socket or power) complete with fitting such as switches, ceiling roses, lamp holders, sockets, fan regulators, wooden terminal box plastic laminated sheet cover from TW battens including TW batten or drawing from existing conduit removing including TW batten all as specified and as directed by Engr-in-Charge.
Taking down carefully existing wooden board , Main switch, MCB DB boxes with MCBs, sheet metal boxes, cut out, etc of any size any capacity from boards complete all as specified and as directed.
Taking down carefully sub main wiring / service connection twin core from wall / LT pole of any size of Aluminum with wooden batten and or through rigid conduit including GI wire and making good the disturbed surfaces of walls, roofs, floors etc complete all as specified and as directed.
M & L for concealed point wiring for one light point controlled by one switch complete with PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable of 1.5 sqmm (nominal area) with stranded copper conductor single core 1100 volts grade in and including rigid PVC conduit not less than 20 mm dia, clip, with MS terminal boxes (not less than 1.6 mm thick) and painted with one coat of red oxide primer all around and two coats of black bituminous paint from out side and two coat of aluminum paint from in side including common earth dolly with 3 mm thick plastic laminated sheet top cover of approved make and colour including 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete including cutting necessary chases on wall / ceiling surfaces for drawing of conduit & cables as required and making good disturbed surfaces of walls with CM 1:3:6 and matching with the existing surfaces including colour washing all as specified and as directed .
Description same as per item No 134 above but one fan point controlled by one switch & regulator.
Description same as per item No 134 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on same board.
Description same as per item No 134 above but One 3/5 pin 5 Amp socket outlet point controlled by one switch on independent board.
Description all as per item No 134 above but using 2.5 sqmm single core multi stranded copper conductor PVC insulated and unsheathed flame retardant low smoke and halogen ( FRLSH ) cable for 3/6 pin 15 Amp socket outlet controlled by one switch on independent board with 1.5 sqmm green stranded copper conductor as continuous earth wire with lugs complete all as specified and as directed.
S&F switch piano flush button type 5 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp flush type complete all as specified and as directed.
S&F switch piano flush button type 15 Amp single pole one way complete all as specified and as directed.
S&F socket outlet 2in1, 3 pin, 5 Amp and 15 Amp flush type complete all as specified and as directed.
S&F ceiling rose,surface bakelite 63 x50mm three terminals complete all as specified and as directed.
S & F Sheet metal enclosure double door concealed suitable for distribution board when MCB to be used having 100 Amp rated bus bar SPN DB 8 ways 240 volts complete all as specified and as directed.
S&F MCB single pole and neutral 40/63 Amp 240 V ,10KA , 'C' series, connected with copper lugs complete all as specified and as directed.
S&F Rigid non-metallic PVC conduit not less than 25mm dia exclusive of boxes (junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, locknuts, saddles, pipe hooks etc. complete all as specified and as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV type 1 flat size 250x150x40mm peak, laid perpendicular to the axis of cable in trenches complete all as specified and as directed.
S&F ceiling fan complete with blades, down rods, electronic regulator and accessories, 230V, 1200mm sweep. Minimum air delivery 210CFM with service value 6.00BEE. Five star rated with squirrel cage induction motor, copper binding complete all as specified and as directed.
S&F exhaust fan, copper binding, steel body AC, Single Phase, 230V of size 300mm sweep, 1400RPM with louvre complete including all arrangement of making holes on wall, making good and finishing of disturbed surfaces matching with the existing surfaces, necessry fixing arrangement such as fastrener, bolts, nuts, washers etc of appropriate size complete all as specified and as directed.
Supply and lay river bed sand free from sharp materialsa for Sand cushioning for cables 8 cm below the cable and 15 cm above the cable all as specified and directed .
Supply and laying GI pipe 50mm bore "LIGHT GRADE" in trenches, under floors, roads, along poles for protection of cables, including sealing ends complete all as specified and as directed.
S&F MCB single pole 6 to 32Amps 240 V,10KA, 'C' series, connected with copper lugs complete all as specified and as directed.
S&F MCCB 4 pole, 415V, AC , 3 phase, 50 HZ, breaking capacity 16 KA with fixed thermal and fixed magnetic setting of capacity 125 Amps 'C' series complete all as specified and as directed.
S & F Lamp holder,PVC/Urea type with back plate suitable for batten fittings complete all as specified as directed
S & F delux Fan Regulator electronic rotary, step type 240 Volt 50 Hz, complete all as specified as directed.
S&F LED security/street light fittings1x35W LED 5700K energy saving and envoiremental frendly long life versatile pressure die cast aluminium housing with acrylic cover as diffuser with IP 66 protection and impact resistance of IK 07 luminaire with high power LED as light siurce and electronic driver suitable for pole dia 35mm including 35mm dia light grade tube bracket, bend to shape 1.80m long with two numbers clamp of size 50mmx6mm with nuts, bolts, washers etc including connection with 1.5Sqmm two single core PVC insulated and PVC sheathed cable stranded copper conductor upto ceiling rose and fixing on wall /pole complete as ditrected by Engineer in Charge. Make: Bajaj Cat Part No BRLEP20WLEDWH or equivalent make as specified in Appendix B to particular specification.
S & F 9W/10W LED retrofit lamp B-22 holder base with polycorbonate body and aluminium heat sink complete all as specified as directed. Make C&S Cat No LTHPLEDLAMP7W/B22 or equivalent make as specified in Appndx 'B' to PS .
M&L for sub main wiring with 2 run of single core PVC insulated and PVC Unsheathed, multistranded copper condutor of nominal area 6 sqmm FRLS, 1100 Volts grade cable drawn into conduit (Existing / new) including all fittings and one run of PVC insulated and PVC unsheathed, multistranded copper conductor of nominal area 6 sqmm FRLS 1100 volts grade cable continuous earth wire of green colour code complete all as specified and as directed Note:- (a) Two runs of 6 sqmm cable and one run of 6 Sqmm cable as earth lead with conduit shall be measured as one unit length for payment. (b) New conduit and conduit accossories shall be measured separately.
Supply and fixing in repair 20/22W LED 6000k Decorative ultra slim linear LED fitting fixture with extruded polycarbonate ,environmental friendly ,energy efficentinterated driver and 22watts lamp fitted including wiring upto and terminal into ceiling rose complete all as specified and directed by Engr-in- Charge.
Supply,laying connecting and testing of cable XLPE insulated,screened,PVC bedded galvanized steel strip or wire armoured electric power cable (heavy duty) 1100 V grade with multi stranded aluminium conductor of size 16 sqmm 4 core as per IS 7092 Pt-I complete all as specified and as directed.
S&F TPN DB-DPX 125 MCCB DBs 4 way single door with provision for DPX 125 MCCB and as incomer and SP/TP MCBs as outgoing Nos of modules DPX 125+12, including 125 Amp MCCB complete all as specified and directed.
M&L for earthing complete with galvanised steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick weithing not less than 17.5 Kg buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below ground level, connected to galvanized earth lead wire 4.00 mm dia by means of bolts nuts check nuts & washers of galvanized iron or steel , procteded by GI pipe 15 mm bore( light grade) and watering pipe 20 mm bore GI pipe (light grade) and chamber of pcc 1:4:8 type D2 using 40 mm graded stone aggregate and coping shall be in PCC 1:3:6 type C1 using 20mm graded stone agg. 50 mm thick cover of RCC 1:2:4 type B1 using 20 mm graded stone agg. reinforced with 8 mm dia MS tor bar @ 80 mm c/c both ways including excvation and earth work and removal of surplus soil complete all as shown in electrical plate no 3 of SSR PT 1, 2009 with charcoal dust and salt complete and earth lead connected to earthing test point (up to main switches, DBs) complete all as specified & testing on completion. NOTE:- (I) item includes the cost of 7.5 mtr length GI pipe for protection for GI earth wire. (ii) item rates includes the cost of 7.5 mtr earth lead GI earth wire. (iii) PCC pit shall be provided at least 500mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe,bends,elbow etc shall be deemed included in the unit rate.
M/S RAJ KUMAR SINGH
M/s Hansraj Shivhare
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .