Loading…
Loading…
Tender Value
₹92.6 L
EMD Value
₹1.9 L
Closing Date
10 Aug 2026, 5:30 pm
Executive Engineer, Div II Aquem Margao
Executive Engineer, Div II Aquem Margao
Supply of Switch Disconnector Fuse Unit of various ratings.
2026_ED_30723_1
10/ET/26-27 Ten-10/26-27
Open Tender
Electrical Work/ Equipment
Supply
90 days
Executive Engineer, Div II Aquem Margao
As per NIT documents
2 documents required · 2 mandatory
₹1,500
Yes
₹1.9 L
Yes
29 Jul 2026
29 Jul 2026
11 Aug 2026
29 Jul 2026
10 Aug 2026
30 Jul 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Switch Disconnector fuse unit of 200 amps with HRC fuses in sheet steel enlosure, triple pole with neutral link with suitable earthing arrangements conforming to IS: 13947/1993(pt-I&III) complete with handle assembly having door interlock in "ON" position with indicators for rated voltage of 415V, 50 Hz suitable for and BS type High rupturing capacity cartridge fuses conforming to IS: 13703 & having rupturing capacity not less than 50KA of rating 200 amps, categroy of duty AC-23A. | 100 | Nos. | 8,775 | ₹8,77,500 |
| 2 | Switch Disconnector fuse unit of 315 amps with HRC fuses in sheet steel enlosure, triple pole with neutral link with suitable earthing arrangements conforming to IS: 13947/1993(pt-I&III) complete with handle assembly having door interlock in "ON" position with indicators for rated voltage of 415V, 50 Hz suitable for and BS type High rupturing capacity cartridge fuses conforming to IS: 13703 & having rupturing capacity not less than 50KA of rating 200 amps, categroy of duty AC-23A. | 100 | Nos. | 11,984 | ₹11,98,400 |
| 3 | Switch Disconnector fuse unit of 400 amps with HRC fuses in sheet steel enlosure, triple pole with neutral link with suitable earthing arrangements conforming to IS: 13947/1993(pt-I&III) complete with handle assembly having door interlock in "ON-OFF" position with indicators. The unit shall be suitable for rated voltage of 415, 50Hz AC-23A utilization category rupturing capacity not less than 80KA for 1second & conform to IS:13947 part 3-1993/IEC 60947-3-1990 as amended upto date. The HRC fuses shall conform to IS: 13703 as amended upto date Switch Disconnector fuse unit shall be of 400A rated operational current. | 500 | Nos. | 14,360 | ₹71,80,000 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 9.54 MB
BOQ_31128.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].