Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹29.3 LAccepted-AOC 1 225 5 6 SADAR BAZAR DELHI CANTT 110010 | NEW DELHI | DELHI | 110010 | 1 | Accepted-AOC AOC | |
| 2 | 2₹34.9 L+₹5.5 L (18.8%)Rejected-Finance A 303 VEENA CGHS LTD PLOT NO 5D SECTOR 22 DWARKA NEW DELHI 110077 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110077 | 2 | Rejected-Finance Rejected Not L1 | |
| 3 | 3₹36.9 L+₹7.6 L (25.9%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 3 | Rejected-Finance Rejected Not L1 | |
| 4 | 4₹40.9 L+₹11.6 L (39.4%)Rejected-Finance WZ 1000 NANGAL RAYA PANKHA ROAD SOUTH WEST DELHI DELHI 110046 | DELHI | SOUTH WEST DELHI | DELHI | 110046 | 4 | Rejected-Finance Rejected Not L1 | |
| 5 | 5₹41.6 L+₹12.3 L (41.8%)Rejected-Finance RZ 212F D BLOCK RAJ NAGAR PART II PALAM COLONY NEW DELHI 110077 | SOUTH WEST | DELHI | 110077 | 5 | Rejected-Finance Rejected Not L1 |
| Sl No | Description | Qty | Unit | MV Engineers And Contractors L5 | Rajindera Enterprises L7 | mayur enterprises L4 | Ridhi engineers and builders L2 | Vijay Electricals L10 | M/s JAIMAA ASSOCIATES L6 | DS CONSTRUCTION L8 | Commercial Traders L3 | SB ENTERPRISES L9 | M P TYAGI ENGINEERS AND CONTRACTORS L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/LT panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges and door handels in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engr-in-Charge. | 22 | Each Job | 1,800 ₹39,600 | 2,500 ₹55,000 | 1,000 ₹22,000 | 150 ₹3,300 | 2,500 ₹55,000 | 800 ₹17,600 | 500 ₹11,000 | 300 ₹6,600 | 999 ₹21,978 | 99 ₹2,178 Lowest |
| 2.00 | Material and labour in replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 2 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) complete all as specified and directed by Engr-in-Charge.
Note :- (a) The panel board repaired shall be made totally enclosed, weather proof for installing incoming/out going MCCB/switch fuses/ cable etc. complete all as directed.
(b) The work is required to be executed in patch works and the rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling, jointing and providing gasket for weather proof etc. as directed to match & accommodate with the existing feeder pillar box / panel board enclousers.
(c) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer with necessary filler coating. | 30 | Sqm | 390 ₹11,700 | 1,500 ₹45,000 | 2,000 ₹60,000 | 450 ₹13,500 | 1,500 ₹45,000 | 3,500 ₹1,05,000 | 2,800 ₹84,000 | 450 ₹13,500 | 999 ₹29,970 | 99 ₹2,970 Lowest |
| 3.00 | Material and labour for disconnecting and taking out old existing unserviceable voltmeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic voltmeter class I, any range matching with in built selector switch, suitable for LT 415 Volts 50Hz AC supply, flush pattern, square type, with adopter complete all as specified and directed by Engr-in-Charge. | 10 | Each | 1,200 ₹12,000 | 300 ₹3,000 Lowest | 1,000 ₹10,000 | 900 ₹9,000 | 2,000 ₹20,000 | 1,600 ₹16,000 | 500 ₹5,000 | 900 ₹9,000 | 999 ₹9,990 | 499 ₹4,990 |
| 4.00 | Material and labour for disconnecting and taking out old existing unserviceable Ammeter of any description and in any position and supply, fixing, connecting, testing and commissioning of 3 phase digital electronic Ammeter class I, any range suitable for matching with existing CT ratio and in built selector switch suitable for LT 415 Volts 50Hz AC supply flush pattern, square type, 96mm x 96 mm with adopter complete all as specified and directed by Engr-in-Charge. | 10 | Each | 1,200 ₹12,000 | 300 ₹3,000 Lowest | 1,000 ₹10,000 | 900 ₹9,000 | 3,000 ₹30,000 | 1,600 ₹16,000 | 500 ₹5,000 | 1,200 ₹12,000 | 999 ₹9,990 | 499 ₹4,990 |
| 5.00 | Material and labour for disconnecting and taking out old existing unserviceable Phase indication lamps and supply, fixing, connecting and, testing LED type Phase indication lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed by Engr-in-Charge. | 18 | Set of 3 | 350 ₹6,300 | 600 ₹10,800 | 1,000 ₹18,000 | 45 ₹810 Lowest | 4,000 ₹72,000 | 400 ₹7,200 | 300 ₹5,400 | 150 ₹2,700 | 399 ₹7,182 | 99 ₹1,782 |
| 6.00 | Material and labour for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge. | 150 | Sqm | 350 ₹52,500 | 150 ₹22,500 | 1,000 ₹1,50,000 | 45 ₹6,750 | 699 ₹1,04,850 | 120 ₹18,000 | 200 ₹30,000 | 35 ₹5,250 Lowest | 499 ₹74,850 | 49 ₹7,350 |
| 7.00Supply & fixing of MCCB 415V AC, 4 pole should have reverse load and line termination, For 32-100 A:Should have breaking capacity of min.16 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu. For 100-160 A:Should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu. For 200-315 A:should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100 % and magnetic release adustable from 5 to 10 In with Ics=100% Icu.For 400-630 A:should have breaking capacity of 36 KA and thermal release adjustable from 80 to 100% and magnetic releases adjustable from 5 to 10 In with Ics=100% Icu. with adjustable overload and adjustable short circuit protection in existing LT panel/provn of fixing arrangements by cutting and drilling busbar to exact size/provision of copper leads of suitable size at site to fix MCCB in existing panel including provision of thimbles and nut bolts of proper size and having following cap:- | |||||||||||||
| 7.01 | MCCB 630 Amp 4 pole. | 13 | Each | 22,000 ₹2,86,000 | 11,000 ₹1,43,000 | 15,000 ₹1,95,000 | 9,000 ₹1,17,000 | 30,000 ₹3,90,000 | 26,000 ₹3,38,000 | 32,000 ₹4,16,000 | 27,500 ₹3,57,500 | 11,999 ₹1,55,987 | 4,999 ₹64,987 Lowest |
| 7.02 | MCCB 400 Amp 4 pole. | 17 | Each | 19,000 ₹3,23,000 | 10,000 ₹1,70,000 | 12,000 ₹2,04,000 | 7,500 ₹1,27,500 | 20,000 ₹3,40,000 | 14,000 ₹2,38,000 | 28,500 ₹4,84,500 | 18,500 ₹3,14,500 | 9,999 ₹1,69,983 | 3,999 ₹67,983 Lowest |
| 7.03 | MCCB 250 Amp 4 pole. | 15 | Each | 16,000 ₹2,40,000 | 9,000 ₹1,35,000 | 10,000 ₹1,50,000 | 7,000 ₹1,05,000 | 20,000 ₹3,00,000 | 12,000 ₹1,80,000 | 24,000 ₹3,60,000 | 10,500 ₹1,57,500 | 5,599 ₹83,985 | 2,999 ₹44,985 Lowest |
Tender Value
₹45.5 L
EMD Value
₹91,000
Closing Date
11 Jul 2025, 6:00 pmClosed
GE UTILITY ELECTRIC SUPPLY
GE UTILITY ELECTRIC SUPPLY DELHI CANTT-10
REPAIR AND MAINT OF LT PANEL, ACBs, MCCBs AND CONNECTED ITEMS AT MANEKSHAW MARG, URBAN VILLAGE, MALL ROAD, POLO ROAD, CHURCH ROAD, TIGRIS ROAD, CASSEL ROAD, STATION ROAD, MANDIR MARG, MAUDE ROAD, 4 NO P/F, HARBAKSH STADIUM, TUBARAK LINES, 972 TPT COY
2025_MES_715732_1
GE ELECT/D-28/2025-26
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE UTILITY ELECTRIC SUPPLY
AS PER TENDER DOCUMENT
7 documents required · 7 mandatory
₹500
Yes
GE UTILITY ELECTRIC SUPPLY
₹91,000
Yes
29 Sept 2025
20 Jun 2025
14 Jul 2025
20 Jun 2025
11 Jul 2025
4 Jul 2025
Amount
Material and labour for dismantling, taking down and removing the old existing un serviceable non-functional / broken hinges of any description and in any position of existing feeder pillar boxes/LT panel boards etc and supply and fixing new cold rolled medium weight mild steel hinges and door handels in position as per existing requirement with necessary spot welding, screwing etc including making necessary adjustment for free and smooth movement of panel and locking arrangements complete all as specified and directed by Engr-in-Charge.
Material and labour in replacement of existing unserviceable/damaged part/portion of the existing feeder pillar box/ panel boards with supply and fixing new part or portion fabricated out of 2 mm thick MS sheet in position including making necessary adjustments and alignments to make the existing feeder pillar box/panel board body to required shape and size(s) complete all as specified and directed by Engr-in-Charge. Note :- (a) The panel board repaired shall be made totally enclosed, weather proof for installing incoming/out going MCCB/switch fuses/ cable etc. complete all as directed. (b) The work is required to be executed in patch works and the rates quoted by the contractor are deemed to be with and including necessary cutting, welding, leveling, jointing and providing gasket for weather proof etc. as directed to match & accommodate with the existing feeder pillar box / panel board enclousers. (c) The replaced portion shall be painted with two coat of synthetic enameled paint over a coat of red oxide primer with necessary filler coating.
Material and labour for disconnecting and taking out old existing unserviceable Phase indication lamps and supply, fixing, connecting and, testing LED type Phase indication lamp with showing red, yellow and green colours of 22.5mm dia fixed to monitor on LT panel board suitable for 240 Volts AC supply and making connections with using suitable size copper cables wires and lugs complete all as specified and directed by Engr-in-Charge.
Material and labour for preparation of old steel surfaces of steel/LT panel boards/feeder pillar boxes of any description & any position including removing disintegrated/detoriating part of paint and applying filler coat to obtain smooth surfaces and applying a coat of synthetic enamel paint using spray machine to obtain smooth finish to the entire satisfaction of Engineer-in-Charge complete all as specified and directed by Engr-in-Charge.
Supply & fixing of MCCB 415V AC, 4 pole should have reverse load and line termination, For 32-100 A:Should have breaking capacity of min.16 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu. For 100-160 A:Should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100% & fixed manetic release with Ics=100% Icu. For 200-315 A:should have breaking capacity of min.25 KA with thermal release adustable from 80 to 100 % and magnetic release adustable from 5 to 10 In with Ics=100% Icu.For 400-630 A:should have breaking capacity of 36 KA and thermal release adjustable from 80 to 100% and magnetic releases adjustable from 5 to 10 In with Ics=100% Icu. with adjustable overload and adjustable short circuit protection in existing LT panel/provn of fixing arrangements by cutting and drilling busbar to exact size/provision of copper leads of suitable size at site to fix MCCB in existing panel including provision of thimbles and nut bolts of proper size and having following cap:-
MCCB 630 Amp 4 pole.
MCCB 400 Amp 4 pole.
MCCB 250 Amp 4 pole.
MCCB 200 Amp 4 pole.
MCCB 160 Amp 4 pole.
MCCB 100 Amp 4 pole.
Material and labour for cleaning of substations, removing of stones, mud, or any other type of material from the sub station including removing of bushes and throwing them out from cantt area complete all as specified and directed by Engr-in-Charge.
Material and labour for PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate in wall or retaining walls, any thickness, size or shape including plaster, buttresses columns, pillars and posts including caps and bases complete all as specified and directed by Engr-in-Charge.
Supply and fixing of ACB, fixed type, shall confirm to IEC 60947 /IS 13947 (Part 1 & 2). The minimum breaking capacity should be 50KA. The service short circuit breaking capacity (Ics) should be equal to ultimate breaking capacity (Icu) and short time with stand capacity (Icw) with ICS =Icu=Icw. The Icw value is for 1sec. The ACB shall have microprocessor based protection units with flexible and adjustable current - time protection settings for overload, short circuit, instantaneous short circuit and Earth Fault Protections. ACB should be suitable for a 3 phase service voltage, up to 690V for 50/60 Hz AC supply and shall have an insulation voltage of 1000V. All the protection units should have built in Dedicated inbuilt LEDs for fault indication for overload, short circuit and Earth Fault complete all as specified and directed by Engr-in-Charge for the following :-
ACB 800 Amp 4 pole.
ACB 1000 Amp 4 pole.
Supply and Fixing of Junction box thermoplastics polystyrene/polycarbonate enclosure, shock proof, IP65 (weather proof), rust proof, dust proof, water proof, internally embedded gasket with provision for all side cable entry through glands(IP-65) and/or grommets(IP-55). Size of enclosure: (205x255 x112) mm With suitable connecters for 2Ph/1Ph loop in loop out and branch out vibration proof connections complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 1000/800 Sqmm complete all as specified and directed by Engr-in-Charge
Supply and fixing of aluminium lugs of size 630 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 400 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 300 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 185 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 120 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 95 Sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 70 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 50 sqmm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of aluminium lugs of size 35 sqmm complete all as specified and directed by Engr-in-Charge.
Dismantling and M&L for Danger notice plate of 1.6mm thick MS sheet vitreous enamelled white with letters, figures and conventional skull and bones in signal Red colour and inclusive fixed with MS flat clamps 25x3mm 2 Nos, nuts, bolts for LT 440 volt of size 20x15cm complete all as specified and directed by Engr-in-Charge.
Supply and fixing of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 06 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 10 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing of multi core round PVC insulated copper conductor (flexible) industrial cables PVC sheathed cables, 1100 volts conforming to IS : 694 of size 2.5 Sqmm, 3 core panel to street light inside/outside pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing of service connection with PVC insulated and PVC sheathed flat twin core cable 1100V grade heavy duty electric cable served all PVC sheathed in service connections suspendedsuspension wire and loop insulators and as directed of size 06 Sqmm cross sectional area stranded aluminium conductor complete all as specified and directed by Engr-in-Charge.
Material & labour for painting to transformer guard (XPM), fencing channels mounted on plinth to all steel parts with silver aluminium paint one coat.all as specified and directed by Engg in Charge (approx 30 to 50 sqm) complete all as specified and directed by Engr-in-Charge.
Supply and fixing of LED Flood lights 50 Watt made up of pressure die cast housing with toughned glass and individual high power LEDs with secondary optics, IP66 protection complete all as specified and directed by Engr-in-Charge.
Supplying and installation of 3 Pole power contractor, type MNX 110 having 2 NO +2 NC contacts complete all as specified and directed by Engr-in-Charge. Make : L&T Cat part no CS94137 or equivalent in Havells/Schnider as approved by GE.
Supplying and installation of Analog Time switch, 240 Volt AC, 50 Hz - 01 Nos complete all as specified and directed by Engr-in-Charge. Make L&T Cat No J648B1 or equivalent in Havells/Schnider as approved by GE.
Supply and fixing of 3.5 m long post top light pole aesthetically designed decorative hot dipped galvanised mild steel step pole with grey powder finish, plasma cut & duly chamfered opening window of 300x110 mm for terminal connections & mounting accessories. Window cover is fitted with allen screws to the pole complete all as specified and directed by Engr-in-Charge.
Supply and fixing of 35 W post top lantern having protection IP 65/66 complete all as specified and directed by Engr-in-Charge. Make :- Havells (Item code No VICTORIAPT35WLED730PSYMTOTG) or equivalent in Philips/CG as approved by GE.
S&F pole base cover aesthetically designed decorative pole base cover, enhancing the apearance of the pole complete all as specified and directed by Engr-in-Charge. Make : Havells or equivalent in Philips/CG as approved by GE. Note- The cost of excavation and PCC 1:3:6, type C-1 for foundation required for post top light pole is deemed to be included in the quoted rate
Material & labour for disconnecting all electric LT Supply from timer panel of High mast and lowering down the high mast light fitting set by using motor/manually for repair/replacement work and change the unsv/worn out parts after repair works completed check the serviceability of high mast and remove all dust/nest and greasing the rope/motor/gear assembly for proper functioning before raising up in the the original position complete all as specified and directed by Engr-in-Charge.
Supply only stainless steel rope 6mm dia complete all as specified and directed by Engr-in-Charge.
Supply only D clamp including nut bolt and washers complete all as specified and directed by Engr-in-Charge.
Supply only 6 Sqmm 5 Core flexible aluminum cable complete all as specified and directed by Engineer-in-charge
Supply only 1.5 HP motor 3 Ph 440 volt 50 hz AC supply for operating the stainless steel rope through gear assembly complete all as specified and directed by Engineer-in-charge
Supply only gear assembly used for operating the stainless rope for lowering down the high mast fitting complete all as specified and directed by Engr-in-Charge.
Material and labour for disconnecting burnt end or portion of cable removing the cable from loop including necessary excavation & earth work in soft/loose soil relaying and reconnecting the cable by removing burnt portion of cable and preparing fresh terminals including fixing of new lugs for 50 Sqmm 3½ / 4 to 400 Sqmm of LT cable to pole / main switch complete all as specified and directed by Engr-in-Charge.
Supply, laying, jointing, testing and commissioning in replacment of LT underground cables 1100 volts grade, PVC insulated XLPE and PVC sheathed, heavy duty armoured, with multistranded aluminium conductors, IS-1554 marked of size 240 Sqmm 3.5 core, laid in trenches complete all as specified and directed by Engr-in-Charge. Note : Excavation, earth work ,cable protection , sand fillings , cable joint shall be measured and paid separately.
Material and labour for Cutting / pruning of tree branches along security light pole around 2 mtr radius of security light and removing from site including arrangement of T&P (Axe, rope & ladder etc) complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement MCB SPN, 32 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-Charge.
Supplying and fixing in replacement MCB SP, 6 to 32 Amps,50 Hz,10 KA,240 Volts complete all as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT Panel board ,cubical compartmentalized , out door type double door , mounted on angle iron legs 50x50x6mm thick, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system accomodated with 01 No ACB 4 pole, 1000 Amp, 50 KA, 415 Volt AC Horizontal draw out type motorized, front operated with Micro processor based LCD protection release for adjustable over current, short circuit and earth fault protection fitted with aluminium bus bar link 1200 Amps for incomming and outgoing cable connection. The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement . including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. Outgoing. (a) Suitable hole in bus bar for out going cable connection including suitable size nut bolt and fastener complete all as specified and directed by Engr-in-Charge.
Supplying, fabrication, installation, testing and commissioning in replacement of LT panel not less than 3mm thick of modular polycarbonate thermoplastic enclosures Indoor type with copper bus bar of capacity 400A, factory made, CPRI approved,e floor mounting type, environment friendly, recyclable, UV resistant, halogen and silicon free, anti-acid and anti corrosive, enclosure should be IP-65 Protection in accordance with IEC 60529.The gasket material shall be polyurethane while the gasket shall be internally embedded including suitable working space in bus bar chamber suitable for 3 phase 4 wire system 415V,50HZ,AC supply and fixed on raised PCC 1:2:4,type B1 (20mm graded aggregate) raised base with cable glands, phase indicators, internal wiring, CT of suitable Ratio, digital voltmeter and ammeter, air passing holes with bproper spacing to accommodate to all control switches and other accessories, cable connections with suitable size of lugs/thimble etc including suitable size canopy to cover the panel with proper fixing arrangement including excavation and elarth work including dismantling the unserviceable panel and comprising the followings. Incoming:- (a) MCCB 250 Amps 3 Pole,36 KA- 01 No (b) Rotary handle- 01 No (C) spreader Link- 01 set( 08 Pcs) (d) RYB Indicating lamp (e) Digital laVoltmeter and ammeter of suitable rating (f) set of ibtCT of ratio - 250/05 Amps Outgoing. (a) Suitable hole in bus bar for out going cable connection including suitable size nut bolt and fastener complete all as specified and directed by Engr-in-Charge.
S&F in renewal on load change over switch sheet steel enclosure execution of capacity 400 Amps, 4 pole, 415 volt , 50 Hz fixed in any type of existing Floor/ wall including taking out old existing unserviceable change over from panels etc complete all as specified and directed by Engr-in-Charge.
Supply, installing, testing and commissioning in replacement of factory made and tested (including CPRI type tested certified panel) LT on load change over Panel board, cubical compartmentalized, out door type double door , mounted on angle iron legs 50x50x6mm thick, suitable for 415 volts, 3 phase, 4 wire, 50 HZ AC supply system accomodated with 01 No, on load change over switch execution of capacity 630 Amps , 4 pole , 415 volt , 50 Hz fixed in any type of . The panel shall be dust and vermin proof. IP-65 class protection and shell be made of 3.15 mm CRCA MS sheet, and 50x50x6mm thick MS angle iron frame work, powder coated finish over one coat of red oxide primer on outside surface and painted inside with two coats of red oxide primer, front and rear opening type, with apron for cable entry closing locking arrangement . including excavation, earth work and platform for the panel with PCC 1:4:8 type D-2 with 40 mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15 mm thick in CM 1:6 on exposed surfaces and 100 mm thick PCC padding 1:3:6, type C-1 using 20 mm graded crushed sotne aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45 cm above the nearest road level. NOTE:- LT panel size not less than 1000X1000X800mm.
M&L for excavation in trenches not exceeding 1.5m wide & not exceeding 1.5m in depth and n.exc 10 sqm on plan for foundations , laying of LT under ground cables/ GI pipes and steel tubular poles etc. and getting out as in soft / loose soil complete all as specified and directed by Engr-in-Charge.
M&L for returning, filling in, including spreading, levelling, watering and well ramming in layers not exc. 25 cm deep as in soil complete all as specified and directed by Engr-in-Charge.
M&L for removal of excavated material n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above in starting point complete all as specified and directed by Engr-in-Charge.
M&L for Sand filling in trenches for cushioning of UG cables as layers of 8 cm before laying and 15 cm after laying of cables complete all as specified and directed by Engr-in-Charge. Note : Measurement shall be taken after punning down.
S&F of common burnt bricks as mechanical protection of this cables using old size sub class ‘B’ bricks laid dry flat over the cable width equal to the length complete all as specified and directed by Engr-in-Charge.
All as per srl item No 53 here-in-before but using old bricks obtained under srl item No 49 complete all as specified and directed by Engr-in-Charge.
Note : contractor should procure and provide 50 % of the material as listed above within 15 days of the placing of work order and shall be verified by the Engr-in-charge
Ridhi engineers and builders (BID ID -3354945)
Commercial Traders (BID ID -3355560)
mayur enterprises (BID ID -3354217)
MV Engineers And Contractors (BID ID -3352698)
M/s JAIMAA ASSOCIATES (BID ID -3355146)
Rajindera Enterprises (BID ID -3353362)
DS CONSTRUCTION (BID ID -3355469)
SB ENTERPRISES (BID ID -3354569)
Vijay Electricals (BID ID -3355079)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .