Tender Value
₹99.3 L
EMD Value
₹2.0 L
Closing Date
5 Jun 2026, 4:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
ELECT.G
17 conditions · 5 needing a document upload
Financial Eligibility Criteria: (Ref: RB letter No. 2022/CE-I/CT/GCC- 2022/POLICY : Advance Correction Slip No.-1 dt 14.07.2022) The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-I, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The intending tenderers should possess a valid electrical contractor license at the time of opening of tender, issued by any state government & same should be submitted along with tender documents by all bidders including working contractors of this unit otherwise offer shall be summarily rejected....... IT SHOULD BE NOTED BY THE TENDERER THAT ELECTRICAL LICENSE UNDER RENEWAL AT THE TIME OF TENDER OPENING WILL NOT BE CONSIDERED AND OFFER WILL BE SUMMARILY REJECTED. IT IS THE RESPONSIBILITY OF TENDERER TO UPLOAD VALID ELECTRICAL CONTRACTOR LICENSE ON THE DATE OF TENDER OPENING.
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
36 conditions · 4 needing a document upload
The rate to be quoted by tenderer shall be inclusive of all state/central taxes including GST. THE TENDERER SHOULD UPLOAD VALID GST REGISTRATION CERTIFICATE ALONG WITH THE OFFER.
The tender shall comply with General Condition of contract (GCC),2022 of Indian Railways (file attached). and its latest amendment, if any. The tenderer shall submit the offer after duly satisfying himself/herself with the GCC,2022 in general.
Tenderers are required to upload the Bank details as per Annexure-XII (Real Time Gross Saving (RTGS)/National Electronic Fund Transfer (NEFT) Model Mandate Form)of tender document.
Tenderers are required to upload requisite details as per Annexure-VIIB (DETAILS OF CONTRACTUAL PAYMENT RECEIVED IN LAST THREE FINANCIAL YEARS AND CURRENT FINANCIAL YEAR) without which the offer is liable to be rejected.
Tenderers are compulsorily required to upload Affidavit as per Annexure-XXIV along with tender document, without which the offer will be considered incomplete and will be rejected summarily.
All requisite documents/credentials mentioned in clause 3.5 of the tender document attached pertaining to his/their technical and financial eligibility. (As applicable).
All requisite documents mentioned in clause 3.7 of the tender document attached pertaining to constitution of firm/concern. (As applicable).
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
No post tender correspondence for submission of additional documents shall be entertained after opening of the Technical & Commercial offers. Even suo-moto post tender letters of the tenderer/s shall be treated as Null & Void.
Defective parts shall only be replaced with OEM's spares. Proper invoices/delivery challan /warranty certificate etc. shall be provided by the firm to prove genuineness of spare parts.
This tender complies with Public Procurement Policy (Make in India) Order 2017, dated 15/06/2017, issued by Department of Industrial Promotion and Policy, Ministry of Commerce, circulated vide Railway Board letter no. 2015/RS(G)/779/5 dated 03/08/2017 and 27/12/2017.
IF ANY DISCREPANCY IS FOUND IN THE TENDER DOCUMENT, NAMELY SOR ITEM DESCRIPTION, SPECIAL TENDER CONDITION ETC., CLARIFICATION CAN BE SOUGHT FROM THE OFFICE OF SRDEE/G/DLI, DRM OFFICE, STATE ENTRY ROAD, NEW DELHI.
This tender complies with Railway Board instructions for Startups (recognized by Department of Industrial Policy and Promotion, Ministry of Commerce and Industry) for exemption from payment of Bid Security as detailed in GCC 2022 as amended from time to time. Such Startup firms may note that no other exemption is applicable to them in this particular tender.
On account payment, contractor shall submitted indemnity bond with validity up to the completion/extended period in the prescribed format (please refer Annexure-XXVIII) at the contractor's cost, vesting the ownership of such material with the railways.
This tender shall also complies with "Indian Railways Standard General Conditions of Contract, April 2022 (Advance Correction Slip No. 11)" vide Railway Board letter No. 2022/CE-I/CT/GCC- 2022/POLICY/Pt.I (E-3320424), dated: 13.03.2026 (attached)
All disputes or differences of any kind whatsoever arising out of or in connection with this contract, whether during its execution or after completion, termination, or breach thereof, shall be subject to the exclusive jurisdiction of the competent courts at New Delhi only.
The issues not covered under the tender document shall be governed by General conditions of Contract (GCC) 2022 or its latest amendments if any during entire period of contract. If any contradiction in Tender Document and GCC is observed then GCC shall prevail.
Electrical work in connection with "Replacement of Old aged 03 Nos. V.T. Pumps of 150 HP with other associated accessories at New Rainey Well at HNZM near Akshardham"
81-SRDEE-G-DLI-2026-27
81-SRDEE-G-DLI-2026-27
Open
Works - General
6 Months
Delhi, Delhi
₹0
₹2.0 L
5 Jun 2026
14 May 2026
22 May 2026
21 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 99,33,103 | ||
| — | 1.00 | — | — | ||
| Dismantling of old 3 Nos. V.T. Pumps of 150 HP having discharge capacity of 9548 LPM, Head at 50 mtrs. including existing pipeline and valve and loading/ leading from the site to SSB General Store and as per explanatory note. | — | — | — | 1,75,000 | |
| — | 3.00 | — | — | ||
| Supply, lowering, testing & commissioning of clear water vertical turbine pumps self- water lubricated having discharge of 9548 LPM against a head of 50 m and pump column length of 24 meters as per IS 1710(latest version) including cost of all allied works and suitable L.T. motors vertical solid shaft of minimum 150HP for above pumps as per relevant IS, including cost of all allied civil works and as per explanatory note. Pump Make- Kirloskar, KSB, Willow, Jyoti, WPIL or equivalent make and Motor Make- Crompton, ABB, Kirloskar, Simens or equivalent make | — | — | — | 78,75,000 | |
| — | 400.00 | — | — | ||
| Construction of base and fabrication of support structure for installation of VT pumps as per site requirement & as per explanatory note. | — | — | — | 60,000 | |
| — | 1.00 | — | — | ||
| Power Distribution / MCC Control panel inclusion of the One ACB of EDO four Pole of 1000 Amp with Earth Fault, Over Load, Under Voltage relay Qty 1 No as incomer. Qty 1 No, RYB Indication Lamps - 3 Nos, Multifunctional Meter - 1 No, Suitable Copper Bus Bar, Outgoing: 4 Nos MCCB with ROH Handle of Three Pole 315 Amps and Four Pole 63 Amp, 1 No. 32 Amps MCB. Supply, erection and commissioning of LT cubical panel 3 phase and neutral 415 V, 4 wire, free standing floor mounted. LT panel made up of 14/16 SWG CRCA (Cold Rolled Carbon Annealed) sheet after seven tank process and painting with EPOXY powder coating. The panel shall consist of suitable rating TPN (Triple Pole Neutral) tinned copper bus bar supported with DMC/AMC barriers and colour coded with heat shrinkable sleeves. For operation of Pumps VFD suitable for 175 HP load with backup star-delta starters, PLC/HMI for auto cascading and data logging regarding operation of pumps. The metering shall be provided as specified. The panel shall have short circuit with standing capacity of minimum 50 KA (RMS) power frequency test and consist of the switch gear as mentioned below. The panel shall be mounted on channels including supply and fixing as per Technical specification. The complete work has to be carried out by the contractor including masonry work. After execution, all feeder cables have to be connected to new panel with suitable cable glands as per requirement of the Engineer at site and as per explanatory note. Make of Electrical Items to be used: L&T, Siemens, ABB, Havells or equivalent etc., PLC required of adequate capacity for auto operation of pumps in cascading. | — | — | — | 16,53,249 | |
| — | 2.00 | — | — | ||
| Earthing with 600x600x3mm thick copper plate earth electrode as per IS 3043(Latest version), to achieve earth resistance less than one ohm, including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement (Approx. size 600x600 mm) on top, watering pipe of length 2.7 Mtr, connections from earth plate to top with 40x6mm copper strip in 50 mm dia pipe class 'B' provision of earth plate as per drawing and conforming to CPWD General Specifications for Electrical Works Part-I Internal - 2023 and CPWD DSR (E&M) 2022 & as per explanatory note. | — | — | — | 21,834 | |
| — | 10.00 | — | — | ||
| Supplying and laying 40 mm X 6 mm copper strip at 0.3 metre below ground as strip earth electrode confirming to relevant IS as per IS:3043 (Latest version), including connection/ terminating with nut, bolt, spring, washer etc. as required & as per explanatory note. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50 mm) | — | — | — | 19,580 | |
| — | 30.00 | — | — | ||
| Supply, laying, testing & commissioning of 70 sq.mm copper 3 core flexible LT cable from starter to motor including lugs, glands etc. & as per explanatory note. Make: KEI, Havells, Polycab, Gloster, Grandlay or equivalent. | — | — | — | 94,260 | |
| — | 60.00 | — | — | ||
| Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 35 cm and depth- 75 to 100 cm ] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 25,260 | |
| — | 20.00 | — | — | ||
| Laying of one number additional PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground as per IS 1255 (reviewed in 2016) in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench [size width- not less than 55 cm and depth-(75-100) cm] etc. as required as per detail drawing approved by competent authority. In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm | — | — | — | 6,140 | |
| — | 20.00 | — | — | ||
| Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required as per IS 1255 (reviewed in 2016). In case of any demolition of PCC, RCC, road, wall surface etc. the contractor should ensure repairing of the same on own expenses as per site requirement and satisfaction of railway representative and conforming to CPWD General Specifications for Electrical Works Part-II External -2023 and CPWD DSR (E&M) 2025 & as per explanatory note. Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) | — | — | — | 2,780 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022-ACS10_merged.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf GCC ACS No 11
ATTACHMENT
TenderDocument.pdf
ATTACHMENT
SpecialConditionsofContract.pdf
ATTACHMENT
ExplanatoryNote.pdf
ATTACHMENT
Technicalspecifications.pdf
ATTACHMENT
GCCAdvanceCorrectionSlipNo.11.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .