Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.3 LAccepted-AOC NEAR S B O P WARD NO 1 SURDULGARH MANSA | SURDULGARH | MANSA | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹2.5 L+₹8,603.40 (3.57%)Rejected-Finance H NO 2049 HANUMAN COLONY NEAR TCP 3 HISAR CANTT PIN 125006 HARYANA | HISAR | HARYANA | 125006 | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹3.2 L+₹81,732.30 (33.9%)Rejected-Finance CC III 28A JANTA BHAWAN ROAD SIRSA HARYANA 125055 | SIRSA | HARYANA | 125055 | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹4.3 L+₹1.9 L (78.6%)Rejected-Finance FLAT NO 10 S NO 98 PLAT NO 78 SAI SAYAJI PARK A RIGHT BHUSARI COLONY KOTHRUD PUNE 411 038 | PUNE | MAHARASHTRA | 411038 | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹5.0 L+₹2.6 L (108.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
| Sl No | Description | Qty | Unit | shiv shanker enterprises L6 | M/s MANN CONSTRUCTIONS L1 | STAR CONSTRUCTIONS L2 | Ajay Enterprises L4 | M/s Har Nandi Construction Company L5 | M/s Satguru Traders L3 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling and taking down existing false ceiling including grid system, frames, hangers, boards/tiles/panels of any material from any height including scaffolding, staging, safety arrangements and all access equipment, careful removal without damaging adjoining structures, stacking serviceable materials within 50 m lead as directed and disposal of unserviceable materials/debris outside MOD land or to designated dumping area as directed by Engineer-in-Charge, complete all as specified and directed. | 860.34 | SQM | 45 ₹38,715.3 | 5 ₹4,301.7 Lowest | 7 ₹6,022.38 | 100 ₹86,034 | 50 ₹43,017 | 25 ₹21,508.5 |
| 1.02 | S&F powder coated GI suspended ceiling grid system for seamless false ceiling comprising of GI perimeter channel 0.55 mm thick with unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding walls with nylon sleeves and screws at 450 mm c/c; intermediate channel 0.90 mm thick having equal flanges of 15 mm and web of 45 mm suspended from soffit at approximately 900 mm c/c using GI cleats and steel expansion fasteners; ceiling sections (not exceeding 1.2 m length) 0.55 mm thick having knurled web of 50 mm and flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channels with connecting clips at 457 mm c/c, including GI hangers 6 mm dia up to 1200 mm length, adjustable, fixed to RCC slab with ceiling cleats made out of GI flat 40×3 mm size 60 mm long and expansion fasteners 12.5 mm dia 40 mm long, complete all as specified and directed, at any height and including all necessary scaffolding, staging, ladders, access arrangements, safety measures and protective equipment required for execution.
NOTES:
(1) Ceiling boards/tiles shall be measured and paid separately under respective items.
(2) The false ceiling grid shall be executed in coordination with air-conditioning ducting works being executed by other agency, and final levels/positioning shall be fixed only after completion/approval of ducting layout as directed by Engineer-in-Charge. No claim on account of sequencing or coordination shall be admissible. | 860.34 | SQM | 606 ₹5,21,366.04 | 230 ₹1,97,878.2 | 270 ₹2,32,291.8 | 250 ₹2,15,085 | 485 ₹4,17,264.9 | 200 ₹1,72,068 Lowest |
| 1.03 | Refixing old non-asbestos cement fibre boards in existing false ceiling grid at any height involving alignment, cutting where required, fixing with suitable screws/clips as per existing system, replacement of damaged fittings where necessary, and ensuring true level and finish, including all scaffolding, staging, ladders, access arrangements and safety measures required for execution, complete all as specified and directed.
NOTE: Refixing of false ceiling boards shall be carried out only after completion of air-conditioning ducting works by other agency and clearance by Engineer-in-Charge. The contractor shall plan execution in coordination with other agencies, and no claim on account of sequencing or coordination shall be admissible. | 860.34 | SQM | 65 ₹55,922.1 | 45 ₹38,715.3 | 13 ₹11,184.42 Lowest | 150 ₹1,29,051 | 50 ₹43,017 | 150 ₹1,29,051 |
Tender Value
₹8.7 L
EMD Value
₹17,440
Closing Date
27 Jun 2026, 6:00 pmClosed
GE (AF) SIRSA
AIR FORCE STATION SIRSA HARYANA-125055
REPLACEMENT OF FALSE CEILING IN CERTAIN DBs INSIDE TECH AREA AT AF STN SIRSA
2026_MES_772224_1
GE/SRA/T-09/2026-27
Open Tender
Miscellaneous Works
Item Rate
60 days
GE (AF) SIRSA
PLEASE REFER TENDER DOCUMETNS
9 documents required · 9 mandatory
₹500
GE (AF) SIRSA
₹17,440
Yes
30 Jul 2026
15 Jun 2026
29 Jun 2026
15 Jun 2026
27 Jun 2026
22 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Dismantling and taking down existing false ceiling including grid system, frames, hangers, boards/tiles/panels of any material from any height including scaffolding, staging, safety arrangements and all access equipment, careful removal without damaging adjoining structures, stacking serviceable materials within 50 m lead as directed and disposal of unserviceable materials/debris outside MOD land or to designated dumping area as directed by Engineer-in-Charge, complete all as specified and directed. | 860.34 | SQM | - | - |
| 1.02 | S&F powder coated GI suspended ceiling grid system for seamless false ceiling comprising of GI perimeter channel 0.55 mm thick with unequal flanges of 20 mm and 30 mm and web of 27 mm fixed to surrounding walls with nylon sleeves and screws at 450 mm c/c; intermediate channel 0.90 mm thick having equal flanges of 15 mm and web of 45 mm suspended from soffit at approximately 900 mm c/c using GI cleats and steel expansion fasteners; ceiling sections (not exceeding 1.2 m length) 0.55 mm thick having knurled web of 50 mm and flanges of 26 mm each with lips of 10.5 mm fixed to intermediate channels with connecting clips at 457 mm c/c, including GI hangers 6 mm dia up to 1200 mm length, adjustable, fixed to RCC slab with ceiling cleats made out of GI flat 40×3 mm size 60 mm long and expansion fasteners 12.5 mm dia 40 mm long, complete all as specified and directed, at any height and including all necessary scaffolding, staging, ladders, access arrangements, safety measures and protective equipment required for execution.
NOTES:
(1) Ceiling boards/tiles shall be measured and paid separately under respective items.
(2) The false ceiling grid shall be executed in coordination with air-conditioning ducting works being executed by other agency, and final levels/positioning shall be fixed only after completion/approval of ducting layout as directed by Engineer-in-Charge. No claim on account of sequencing or coordination shall be admissible. | 860.34 | SQM | - | - |
| 1.03 | Refixing old non-asbestos cement fibre boards in existing false ceiling grid at any height involving alignment, cutting where required, fixing with suitable screws/clips as per existing system, replacement of damaged fittings where necessary, and ensuring true level and finish, including all scaffolding, staging, ladders, access arrangements and safety measures required for execution, complete all as specified and directed.
NOTE: Refixing of false ceiling boards shall be carried out only after completion of air-conditioning ducting works by other agency and clearance by Engineer-in-Charge. The contractor shall plan execution in coordination with other agencies, and no claim on account of sequencing or coordination shall be admissible. | 860.34 | SQM | - | - |
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.69 MB
Tender.pdf
Additional Documents • 1.05 MB
CREDIT.pdf
Additional Documents • 0.06 MB
BOQ_864697.xls
BOQ • 0.58 MB
GENINSTRUCTION.pdf
Tender Documents • 1.96 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .