Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.8 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹19.0 L+₹1.4 L (8.05%)Rejected-Finance | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹22.7 L+₹5.1 L (29.1%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹23.6 L+₹6.0 L (34.2%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹24.0 L+₹6.4 L (36.1%)Rejected-Finance H NO 1346 SECTOR 13 P HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
Refer Docs
EMD Value
₹72,500
Closing Date
6 Mar 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Col S S Babu
Headquarters 138 Works Engineers Pin-914138 C/o 56 APO
SPL REPAIR/REPLACEMENT OF DISTRIBUTION WIRES, INSTALLATION OF FEEDER UNIT CIRCUIT BREAKERS AND OTHER EQUIPMENT AT 360 COY ASC (SUP) TYPE E UNDER GE 865 EWS AT LEH
2021_MES_419532_1
138WE/L-68/2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
As per NIT
8 documents required · 8 mandatory
₹500
GE 865 EWS
₹72,500
Yes
12 Apr 2021
5 Feb 2021
8 Mar 2021
5 Feb 2021
6 Mar 2021
20 Feb 2021
60 days
Amount
Dismantling of existing steel tubular swaged poles of any size carefully and shifting to mes store yard, complete all as specified and directed by Engr-in-Charge.
Taking down old and unserviceable cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers and setting aside within 50m or as directed by Engr-in-Charge.
Taking down old and rusted earthing plate and connected items, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable drop out fuse unit, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Gang operated Air break switch and connected items i.e. HT insulator, operating device etc., complete all as specified and directed by Engr-in-Charge.
Taking up/down old unserviceable HLPE cable, 11000 volts grade, 3 core, 95 Sqmm, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Insulator any type/size/rating, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Danger notice board of any size/shape, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Lightning arrester and connected items, complete all as specified and directed by Engr-in-Charge.
Taking up or down old unserviceable HLPE insulated cable, 11000 volts grade, 3.5 core, 120 Sqmm, complete all as specified and directed by Engr-in-Charge.
Taking up or down old unserviceable HLPE insulated cable, 11000 volts grade, 4 core, 35 Sqmm, complete all as specified and directed by Engr-in-Charge.
Taking up or down old unserviceable HLPE insulated cable, 11000 volts grade, 2 core, 10 Sqmm, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable 1100 volts grade heavy duty cable, PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections aluminium conductor of size 10 Sqmm, two core including connected items, complete all as specified and directed by Engr-in-Charge.
Taking up or down old unserviceable GI pipe, light grade of size 80mm dia, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable stay assembly and connected items, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable ACSR conductor of any size and any description from any heights/ poles or any location, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable steel wire of any size, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable LT panel of any type/shape and connected items, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Street light of any type/capacity, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable GI bracket and connected items, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Copper conductor of size 1.5 Sqmm, 3 core, complete all as specified and directed by Engr-in-Charge.
Taking down old unserviceable Junction box of any size/type alongwith connected items, complete all as specified and directed by Engr-in-Charge.
Supply and erection of Steel tubular swaged poles, complete with cast iron base plate, finial taper plug, bolts, nuts and screws as specified, type-410, SP-55 (11.00 metres long), pre-painted internally and externally including painting with two coats of aluminium paint over one coat of zinc chrome primer after preparing the surface, after erecting the pole, complete all as specified and as directed by Engineer-In-Charge. Note: Excavation, earth work and cement concrete shall be measured and paid under relevant items of the schedule.
M&L for Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint, complete all as specified and as directed by Engineer-In-Charge.
Material & labour for earthing complete with galvanised iron earth plate electrode 600mm x 600mm x6mm burried directly in ground (earth pit not less than 2.25mtr deep below ground level) with top edge of earth plate not less than 1.50 mtrs below normal ground level, connected with 32 mm x 6 mm size GI strip as earth lead by means of bolts, nuts, checknuts and washers of falvanised iron or steel, complete with 40mm dia GI pipe light grade protection pipe, 20mm dia GI medium grade watering pipe with funnel including charcoal, dust, salt, PCC M-15, type B-1 (using 20 mm graded crushed stone aggregates) in cover reinforced with XPM not less than 4.0 Kg per Sqm, test point etc., all as shown in electric plate No-3 of SSR Part - I (2009), complete with necessary earth work in any type of soil, removal to a distance not exceeding 50 mtr, including testing on completion, complete all as specified and directed by Engr-in-Charge. Note : Earth pit chamber and RCC pit cover shall be painted with two coats of red synthetic enamel paint over one coat of primer including preparing of surface.
M&L for Dropout fuse unit, complete set suitable for 11 KV HT, outdoor type, capacity 200 Amps, including jumper connections with copper flexible designed jumper and testing, commissioning, complete all as specified and as directed by Engineer-In-Charge.
Supply, installation, testing and commissioning of 11 KV outdoor and dropout type, Gang operated air break switch, vertical mounting complete with GI operating rod of suitable length for operating mechanism worked from ground level complete in OFF & ON position for current rating upto 200 Amps, each pole consist of GI steel base, HT insulators as per BSS/ISS, non ferrous knife & spring loaded contacts, arcing horns of adequate section to break magnetising current of the TFs. All ferrus parts hot dipped galvanised and non ferrous parts heavily tinned to withstand weather, complete all as specified and directed by Engineer-In-Charge.
Supply, Laying, jointing and testing of XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables (heavy duty) 11000 volts grade (Earthed), with standard aluminium conductor of size 95 Sqmm 3 Core, complete all as specified and directed by Engr-in-Charge. Make- Gloster/Polycab/Havells.
M&L for cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type joint complete with jointing materials and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 Sqmm to 95 Sqmm, complete all as specified and directed by Engr-in-Charge.
Supply and fixing Pin type, porcelain, vitreous, white, brown or green insulator, size 150mm height, 150mm dia suitable for working pressure 11000 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321- 1931, complete all as specified and directed by Engineer-In-Charge.
Supply and fixing Disc type insulator, porcelain, vitreous 145mm high and 255mm dia ball and socket type, white, brown or green single disc assembly assembly for tension with tension clamps for conductors, suitable for working pressure 11000 volts complete all as specified and as directed by Engineer-In-Charge.
M&L in replacement of Danger Notice board of size 25 x 20 cm and 1.6mm thick MS plate for HT with proper clamping arrangements, complete all as specified and directed by Engr-in-Charge.
S&F Lightning arresters expulsion type complete with all fittings, transmission class, discharge capacity 65 KA, complete all as specified and directed by Engr-in-Charge.
Supply, Laying, jointing and testing of XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables (heavy duty) 1100 volts grade (Earthed), with standard aluminium conductor of size 120 Sqmm 3.5 Core, complete all as specified and directed by Engr-in-Charge. Make- Gloster/Polycab/Havells.
Supply, Laying, jointing and testing of XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables (heavy duty) 1100 volts grade (Earthed), with standard aluminium conductor of size 35 Sqmm 4 Core, complete all as specified and directed by Engr-in-Charge. Make- Gloster/Polycab/Havells.
Supply, Laying, jointing and testing of XLPE insulated screened PVC bedded, galvanised steel strip of wire armoured, electric power cables (heavy duty) 1100 volts grade (Earthed), with standard aluminium conductor of size 10 Sqmm 2 Core, complete all as specified and directed by Engr-in-Charge. Make- Gloster/Polycab/Havells.
Supply, Laying, jointing and testing of 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circular stranded conductor of size 10 Sqmm, complete all as specified and directed by Engr-in-Charge. Make- Gloster/Polycab/Havells.
Construction of platform for single transformer of size 3.00m x 2.00m x 1.20 mtr high from natural ground level with brick/PCC block masonary walling including steps, XPM fencing fixed on angle iron posts upto 1.20m hight with gate and licking arrangement, painting etc., complete all as specified and directed by Engr-in-Charge.
Excavation in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth and getting out, in any type of soil, complete all as specified and directed by Engr-in-Charge.
Sand cushioning to protection of underground cables, laid 8 Cm before laying and 15 Cm after laying of cable, and punned to form an overall layer of 18 Cm thick, complete all as specified and directed by Engr-in-Charge. Note: Punned thickness shall be measured.
Returning filling in incl spreading levelling watering and well ramming in layers n. exc 25cm thick complete all as specified and directed by Engr-in-Charge.
Removing excavated soil to a distance n exc 50m and depositing at a level n exc 1.5m above the starting point complete all as specified and directed by Engr-in-Charge.
Supplying and laying un-reinforced precast concrete cable cover, Class LV Type-I, flat, size 250mm x 150mm x 40mm, complete all as specified and directed by Engr-in-Charge.
Supply and laying Tubes, 'light grade' galvanised 80 mm bore, ISI marked, laid in trenches or fixed to walls/ poles with mild steel clamps, nuts, bolts and washers; for protection of electric cable, complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:4:8 (nominal mix) type D-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:3:6 (nominal mix) type C-2 (using 40mm graded crushed stone aggregates) as in foundation filling and mass concrete for stay complete all as specified and directed by Engr-in-Charge.
M&L for Plain cement concrete 1:2:4 (nominal mix ) type B-1 (using 20 mm graded crushed stone aggregates) as in copings and the like including weathering, slightly rounded or chamfered angles and throating including necessary formwork where required complete all as specified and directed by Engr-in-Charge.
M&L for stay assembly using stay rod 20 mm dia complete with accessories as shown in electric plate No - 1 of SSR Part - I (2009), including loop insulator and galvanised steel wire stranded or size 7/4mm, (excavation and concrete measured separately), complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing overhead ACSR conductor of size squirrel, steel reinforced, weasel, including making connections and fixing on poles with all necessary arrangements, complete all as specified and as directed by Engineer-In-Charge. Note: Weight of ACSR or all aluminium conductors drawn for overhead lines is to be determined by measuring taut horizontal distance between centers of two adjacent poles and compounding the weight of conductors of that size and length and 3% extra added for sag, jointing, jumpers, etc.
M&L for fixing galvanised steel wire with new galvanised steel wire of 3.15/4mm dia, as earth continuity conductor or as cradles hexagonal/ rectangular guard wire, on poles, complete all as specified and directed by Engineer-In-Charge.
Supply and fixing Pin type, porcelain, vitreous, white, brown or green insulator, size 100mm height, 65mm dia for 1100 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321- 1931, complete all as specified and as directed by Engineer-In-Charge.
Supply and fixing Shackle type, porcelain, vitreous, white, brown or green insulator, size 100mm height, 115mm dia for 1100 volts grade, including two galvanised mild steel strip of size 31mm x 5mm, two galvanised iron bolt, two galvanised iron washers and one galvanised iron nut, conforming to IS: 7321- 1931, complete all as specified and as directed by Engineer-In-Charge.
Supply, installation, commissioning and testing Polycarbonate CPRI approved OEM made main LT feeder pillar. The panel shall be made of modular Polycarbonate Thermoplastic Enclosures which should be UV resistance in accordance with IEC 61439-1 clause 10.2.4. The panel should be anti acid and anti corrosive, degree of protection against mechanical load should be IK08 (5 Joule) in accordance with IEC 62262. The manfacturer of board/panel shall submit a copy of CPRI test report in Polycarbonate of Degree of Ingress protection IP65/IP54 in accordance with IEC 60529. The gasket should be internally embedded made of polyurethane. The manufacturer of board/panel shall submit a copy of type test report of a board made out of Polycarbonate Hermoplastic panel in accordance with IEC 60439-1. The CPRI report shall have mention of following tests performed and passed out satisfactorily : Temperature rise, Dielectric properties, Short circuit withstand current - rated peak and short time withstand current and rated conditional short circuit current, effectiveness of protective circuits, clearance & creepage distance, Mechanical operation, for the assembly of power switch gear and control gear assemblies (PSC) upto 630A in accordance with IEC 61439 Part 1&2.
The board manufacturer must submit the copy of type test reports for Polycarbonate Thermoplastic Board only. Test reports submitted of other material of construction like MS, SS will not be applicable. Each Board shall have individual routine test report of the manufacturer, Guarantee and Warrantee certificates will be accepted only from original manufacturer. The panel should passed glow wire test 960oC in accordance with 60695-2-11 (flame retardant and self-extinguishing). Make : Hensel/Rittal/Emitter/Schneider.
Power Distribution Panel outdoor/floor mounting with accessories :- Incoming : (i) 250 Amp, 50 KA MCCB TP - 01 No Outgoing : (i) 63 Amp, MCB TP - 02 Nos (ii) 40 Amp, MCB TP - 02 Nos (iii) Digital Ammeter, Digital Voltmeter, LED indicators (RYB) (iv) Aluminium Busbar 250 Amp (v) Onload Changeover switch 250 Amp
Supply, fixing, connecting and testing street light LED type suitable for working on 230 volts, 50 Hz, AC of 45 Watts, complete all as specified and directed by Engr-in-Charge. Make : Havells/Crompton Greaves/Bajaj/Syska.
Supply and fixing GI Bracket made out of 50mm dia, medium grade pipe, 1.20m length to shape for fixing on pole and suitable for 45 Watt street light with 02 Nos clamps of flat iron (40 x 4mm) nuts, bolts and washers including painting with two coats of aluminium paint over a coat or primer, complete all as specified and directed by Engr-in-Charge.
Supply, laying and jointing insulated PVC sheathed copper conductor cable 1.5 Sqmm, 3 core from loop in and loop out Jn box to street light fitting, complete all as specified and directed by Engr-in-Charge.
S&F pole junction box, insulated and made out of Polycarbonate with glass fibre reinforced suitable for 25 Sqmm, 4 core with one MCB SP 6 Amps. The size should not be less than 205 x 255 x 112mm, cat part No KF2525. The polycarbonate JB shall be enviornment friendly, recyclable, UV resistant, halogen & silicon free, anti acid and anto corrosive. The JB shall be rated for degree of ingress protection IP66/67 in accordance with IEC 60529. The gasket material shall be polyurethane and the gasket shall be internally embedded. The JB shall be complies with requirements of the standards IEC 60998-1, IEC 60998-2-1, IEC 60670-22 & IEC 60670-2-5. The JB colour according to RAL 9011. The manufacturer of JB/enclosure shall submit a copy of IEC certificate. For better safety the polycarbonate enclosure shall be fire retardant & self-extinguishing in accordance with IEC 60695-2-11, DIN VDE 0304 Part 3, UL subject 94 for flammability V-2. It should be tested at Glow Wire Test for 960oC. The impact strength of polycarbonate enclosure/board i.e. the degree of protection against mechanical load shall be in accordance with EN 50298-98 for IK 08. JB should be with one 6 Amp SP and terminal set assemble by OEM with flap cover. To maintain IP protection supply with 3 Nos of glands polyamide material with metric size. Manfacturer should submit routine test certificate for CJB/PJB. Make : Hensel/Siemens/GE Power/Rittal.
M/S MALIK CHAND SIRI RAM
darshan kumar gandhi
R B TRADERS
Horizon Construction Company
S S BUILDERS
M.S Sharma Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .