| 1 | L1₹30.3 LAccepted-AOC 329 COD COLONY KOYLA NAGAR PO KIDWAI NAGAR KANPUR 208011 | KANPUR | KANPUR | UTTAR PRADESH | 208011 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹36.6 L+₹5.8 L (18.9%)Rejected-Finance 11 82 GROUND FLOOR BLOCK 11 KALYANPURI EAST DELHI DELHI 110091 | EAST DELHI | DELHI | 110091 | L2 | Rejected-Finance OTHER THAN L1 | |
| 3 | L3₹38.3 L+₹7.6 L (24.5%)Rejected-Finance 15 15 KHERIYA BHAN PURANI CHAWANI GWALIOR GWALIOR GWALIOR MADHYA PRADESH 474010 | GWALIOR | MADHYA PRADESH | 474010 | L3 | Rejected-Finance OTHER THAN L1 | |
| 4 | L4₹41.0 L+₹10.2 L (33.0%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN L1 | |
| 5 | L5₹42.6 L+₹11.8 L (38.2%)Rejected-Finance | L5 | Rejected-Finance OTHER THAN L1 |
Tender Value
Refer Docs
EMD Value
₹81,300
Closing Date
6 Apr 2021, 6:00 pmClosed
GE I Kanpur
GE I Kanpur Cariappa Road Kanpur Cantt 208004
SPL REPAIR TO REPLACEMENT OF VARIOUS ITEMS IN ELECT SUPPLY AT KANPUR CANTT, PROVN OF DESERT COOLERS, ACS AND WATER COOLERS AT 9 SIKH LI AND PROVN OF WATER SUPPLY PIPE LINE TO CHILDREN SCHOOL UNDER GE (I) KANPUR
2021_MES_414245_2
GE(I)/KAN/T-68 OF 2020-21
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Kanpur
Class D category a ii and b i
7 documents required · 7 mandatory
₹500
GE I Kanpur
₹81,300
Yes
20 May 2021
16 Mar 2021
8 Apr 2021
16 Mar 2021
6 Apr 2021
25 Mar 2021
Amount
M&L for dismantling, opening of diesel engine cylinder head top for overhauling of DG Set of capacity 380 KVA by opening of its all electrial connection, opening of exhaust fume pipe from exhaust manifold, removing of canopy, disconnecting of diesel engine from the altrnator complete, cleaning of all components, reboring of cylinder on lathe machine, after reboring honing process will be carried out servicing, repair/replacement of any unserviceable spare parts of inlet manifold & exhaust manifold complete incl welding and machining work any type. While lifting and moving the engine all safety precautions will be kept in mind and engine should be handled by trained personnel. Before lifting the engine water and oil will be removed and correct size of tackles, ropes, chains, cranes, hoist or any other lifting or transportation device will be used. After overhauling the engine, the generator will be tested on full load ensuring all electrical connections, fuel, exhaust and other connections i.e. tightening of flywheel coupling, foot mounting, AVM bolts, crank pullet bolts etc complete and testing the DG set after completion of the work complete all as specified and directed. Note: 1. Fixing element of parts shall deemed to be included in this item.Spare parts shall be measured and paid in respective items mentioned hereinafter. 2. The rate deemed to be included for any other items which are not mentioned in schedule/BOQ for satisfactory working of DG Set. 3. All arrangements for testing of DG set shall be Contractor's responsibility. 4. The rate shall be deemed to be included for all tools and plants. 5. The quoted rate shall be included for any type of transportation of DG set or any parts of DG set if required from sub station to work shop and work shop to sub station.
Supply only crank shaft assembly complete set for DG set 380 KVA of make Cumins/ Stanford.
Supply only block set assembly complet set for DG set 380 KVA of make Cumins/ Stanford.
Supply only cam shaft complet set for DG set 380 KVA of make Cumins/ Stanford.
Supply only cam flyer set and Valve Guide for DG set 380 KVA of make Cumins/ Stanford.
Supply only piston assembly set with Rings, Liners and Locks for DG set 380 KVA of make Cumins/ Stanford.
Supply only connecting rod set for DG set 380 KVA of make Cumins/ Stanford.
Supply only head set for DG set 380 KVA of make Cumins/ Stanford.
Supply only E.C.P.G panel for DG set 380 KVA of make Cumins/ Stanford.
Reparing of head set complete including machine work of DG set 380 KVA of make Cumins/ Stanford.
Supply only main bearing for DG set 380 KVA of make Cumins/ Stanford.
Supply only C R bearing set for DG set 380 KVA of make Cumins/ Stanford.
Supply only cam bush set for DG set 380 KVA of make Cumins/ Stanford.
Supply only ring set complete for DG set 380 KVA of make Cumins/ Stanford.
Supply only liner set complete for DG set 380 KVA of make Cumins/ Stanford.
Supply only liner 'O' ring set for DG set 380 KVA of make Cumins/ Stanford.
Supply only bush rod for DG set 380 KVA of make Cumins/ Stanford.
Supply only filter kit complet set for DG set 380 KVA of make Cumins/ Stanford.
Supply only wiring kit complet set for DG set 380 KVA of make Cumins/ Stanford.
Reparing of pump injector complete machine work of DG set 380 KVA of make Cumins/ Stanford.
Supply only head gasket set for DG set 380 KVA of make Cumins/ Stanford.
Supply only engine gasket set for DG set 380 KVA of make Cumins/ Stanford.
Supply only oil seal complet set for DG set 380 KVA of make Cumins/ Stanford.
M&L for toping up engine oil complete all as specified and directed.
Supply & toping up coolant water complete all as specified and directed.
Cleaning of radiator blowing compressed air in the direction opposite to the normal fan airflow direction without using water or any chemicals complete for DG set 380 KVA of make Cumins/ Stanford complete all as specified and directed.
Supply only fan belt complet set for DG set 380 KVA of make Cumins/ Stanford.
Supply only hose pipe complet set for DG set 380 KVA of make Cumins/ Stanford.
Supply only hose pipe clip set complete for DG set 380 KVA of make Cumins/ Stanford.
Supply only banjo washer set for DG set 380 KVA of make Cumins/ Stanford.
Supply only grease complete all as specified and directed.
Supply only waste cotton complete all as specified and directed.
Supply and fixing in replacement of maintinance free battery 12 volt, 180 AH, 25 plate including battery leads and initial charging of battery complete all as specified and directed. Make : Exide/Amron.
S&F in replacement of self starter 24 Volt for DG set 380 KVA complete all as specified and directed. Make Cumins/ Stanford.
Excavation in trenches / foundation in soft / loose soil not exc. 1.5 metre wide and not exc. 1.5 m deep for HT / LT under ground cable / pole fondation/ for laying of pipe line and getting out including forming bottom surface to required level or slope, complete all as specified and directed.
Returning filling of excavated soil after laying the cable with spreading, leveling, watering and well ramming in layers not exceeding 25cm thick in loose/soft soil complete all as specified and directed.
Removal of surplus soil/excavated material obtained from ground level to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above from the starting point complete all as specified and directed.
M&L for clean and dry sand for cushning to U/G cable in layers of 23cm thick (8 Cm before laying the cable and 15 cm thick after laying the cable) in trenches including watering and consolidation complete all as specified and directed. Note: Only punned thickness 18 cm shall be measured and paid under this item.
Supplying and laying un-reinforced precast concrete cable cover, class HV, type-1 with flat of size 300mm x 180mm x 40mm complete all as speified and directed. Make: Mehtab tiles Indore/Hind Mosaic Tiles Upleta. Note: Purchase voucher and manufacturer test certificate shall be submitted by contractor while claiming payment.
M&L for drilling manually in soft / loose soil under road / hard standing / culvert / nala of suitable bore for protection cable & pipe upto 80 mm bore complete all as specified and directed. Note: Depth of bore shall not be more than 1 Mtr from original ground level.
M&L for 80mm bore GI tubing 'light grade' with fittings laid for protection of cable under road crossing / fixed to walls or pole complete all as specified and directed. Note: Clamps for fixing pipe, nuts, bolts washers etc shall be measured and paid separately.
All as per srl item No 41 here in before but 50mm bore GI pipe complete all as specified and directed.
Supply and installation of load break switch 11 KV, 630 Amps, 20 KA complete unit outdoor type, with IP-54 protection extensible 03 way, LBS, floor mounted with internal copper bus bars, consisting of 02 Nos incoming fixed manual load break switch and 01 No outgoing fixed manual load break switch. All live parts, bus bars, LBs connections of LBS should be enclosed in one tank (minimum 3 modules) to avoid multiple interconnections & sealed for life robotially / manually welded non magnetic and non ferrite grade stainess steel tank (SS-304) not less than 2 mm thick having IP67 degree of protection filled with gas as insulation with leakage rate less than 0.1% per year tested as per IEC 62271-200. RMU should complete with all accessories such as Terminal Boots, VPIS, cable supports, all front cable terminations, mechanical indications for Load Break Switch ON / OFF, bushings bolted type top mounted outside the tank for connection of external bus bar compatable to replace at site etc complete all as specified and directed with the following specifications as given in Annexure 'A'. Note : (i) Annexure 'A' has been uploaded alongwith the tender documents and is the part of BOQ for all purposes. (ii) Factory inspection of load break switch and is testing shall be done by the representatie of the Accepting Officer. (iii) The contractor will produce drawing of load break switch (LBS) for according approval before the ordering of material. Make of LBS - ABB / Scheneider / Siemens as approveed by GE
Supply and laying, testing and commissioning of XLPE insulated, screened, PVC sheathed, galvanized steel strip or wire armoured electric power cable with aluminium conductor of cross sectional area 95Sqmm, 3 core, 11 KV rated suitable for earthed system in trenches or passing through pipe/ducts, fixed to wall or poles complete all as specified and directed. Note : Excavation and earth work, sand cushioning, brick covers and GI pipe etc shall be measured and paid separately. Make of cable:- Gloster/ Polycab/ KEl/ CCI/Havells
Supply and fix cable end jointing kit for 11 KV grade cable for indoor termination heat shrink type joint complete with jointing material and all accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 70 to 95 Sqmm complete all as specified and directed. Make :- Denson/ M seal/3 M.
Earthing complete with GI earth plate electrode of size 60cm X 60cm X 6mm buried directly in ground vertically at a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below normal ground level surrounded from all sides by 15 cm thick and packed layer of charcoal dust and common salt filling in alternate layers etc and connected to and including GI strip of size 32x6 mm up to 7.5 mtr by means of bolts, nuts, check nuts and washers made of brass and protected by GI pipe 'light grade' of 40mm bore upto 7.5 mtr long (from earth pit) connected to main control board and GI pipe 'light grade' 20mm bore for watering and including funnel, wire mesh, RCC pit cover 50mm thick with 8mm TMT bar @ 150mm centre to centre and PCC chamber pit with PCC 1:2:4 type B-2 including excavation and earth work disposal of surplus soil to a distance not exceeding 50 metre and testing making test point and testing after completion all as specified and shown on plate No 3 of SSR Part-I 2009 including taking down old unserviceable earthing complete all as specified & directed.
Disconnecting, dismantling and taking out old steel tubular pole of any size/ length and making good all disturbed surface to match with existing specifications complete all as specified & directed.
Dsimantling of air break gang operated switch incl insulators and operating mechanism any type complete all as specified & directed.
M&L for point wiring with PVC (FRLS) insulated and unsheathed cable 1.5 Sqmm (Nominal area) multi-stranded copper conductor single core with proper colour coding including PVC conduit medium grade of 20 mm dia concealed in walls and surface on ceiling with and including pressed steel concealed terminal boxes of appropriate size and top cover 3 mm thick of plastic laminated sheet ISI marked of desired colour of make : Hylam, painting terminal boxes inside and outside with a coat red oxidé primer complete with all accessories with and including 1.5 Sqmm PVC insulated and unsheathed green colour multi-stranded copper conductor cable to common earth and connected to earth dolly complete all as specified and directed for One 5 Pin socket outlet 5 Amps on Independent board. Note: Cutting chases in walls required for concealed conduit wiring shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. Make of cable : Finolex/Plaza/Polycab/Havells/Gloster/Grandlay, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
M&L for point wiring with PVC (FRLS) insulated unsheathed copper conductormulti-stranded single core cable 2.5 Sqmm including green colour earth wire of size 1.50 Sqmm FRLS, for one 15 amps power socket point controlled by one switch, including PVC conduit medium grade of 20 mm dia concealed in walls and surface on ceiling including cutting chases in walls required for concealed conduit wiring and shall be finished with cement mortar 1:4 and, surface shall be matched with existing surface by using putty, plaster of paris etc. and applying finishing coat of existing treatment shall be deemed to be included in the unit rate quoted by the contractor. Make of cable : Finolex/Plaza/Polycab/Havells/Gloster/Grandlay, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
S&F switch piano flush type 5/6 Amps single pole one way complete all as specified and directed. Make: Anchor/SSK/Haveels/Cona
S&F socket outlet flush type, 5 pin 6 Amps, 240 Volts complete all as specified and directed. Make: Anchor/SSK/Haveels/Cona
Supply and fix single pole and neutral enclosue with a top pin and earth plug and socket complete with one SP MCB 25 Amp 240 Volt Make : Havells Cat Part No. DHDMCDPO253025 or equivalent make of Legrand/Siemens/ABB/C&S/Indo Asian
Supply and install of desert cooler 230 volts single phase having nominal air flow capacity of 5000 CMM per hours steel body complete and writing MES No in black synthetic enamel paint etc all as specified and directed.
Supply, installation and commissioning of Water cooler stainless steel tank, electric driven single phase having approx storage 80 ltrs and cooling capacity of 40 ltr / hr complete all as specified and directed. Make : USHA / Voltas / Blue Star as approved by GE. Note : Contractor will submit guarantee/warranty certificate from manufacturer.
Supply and fix Voltage stabilizer for automatic operation, single phase having digital display board naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 3 KVA. Make : V Guard / Voltas / Volina as approved by GE . Note Contractor will submit guarantee/warranty certificate from manufacturer.
M&L for platform for water cooler of size 1m x1m x0.12m high with PCC 1:2:4 type B-2 using 40 mm graded stone aggregate surface finished even and smooth without using extra cement including excavaiton & earthwork etc complete all as specified and directed.
S&F 15mm bore steel tubes medium grade galvanized with all fitting and fixed complete to walls and ceiling or laid in floor complete and all as specified and directed. Make : TATA/Jindal/ Prakash Surya as approved by GE.
S&F 15mm dia bore gun metal Gate valve with iron wheel head conforming to IS : 778/ 1984, Class-1, Screwed both end as per IS: 554 Parallel, ISI marked complete all as specified and directed Make :Leader/ Kiran/ Sant/ Partap Valves, Jallandar/ Zolotov as approved by GE.
S&F MS angle iron support of MS angle 40mmx40mmx6mm thick of suitable size as per site requirements for fixing of desert cooler including nut bolt etc including painting and making good all disturbed surfaces including PCC 1:2:4 type B-1 using 20mm graded stone aggregate for grouting of required size and number for fixing of cooler stand all as specified and directed.
M&L for drilling hole at a depth up to 1.5 mtr below the normal ground level of suitable size to insert upto150 mm dia pipe across the road in horizontal position complete all as directed by the Engr-in-Charge.
M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate finished surface even and fair including demolition of PCC path/plinth/hard standing etc complete all as directed by the Engr-in-Charge.
Supply, laying, testing and commissioning Ductile Iron pipes, 150 mm bore including Rubber gasket joints, Class K-7 in any length laid in trenches complete all as specified and directed . Make: Electrosteel/ Jindal/Lanco/Jai balajee as approved by GE
Cutting existing CI/DI water main 150mm bore pipe in position for making branch connection and CI/DI pipeline (Insertion of CI/DI tees bends of different size on connection pieces or for insertion of sluice valve) including excavation & earth work. Note : Fittings such as tees, bends, collars & reducers etc incl in this item and only run lead joints, CI/DI fittings & sluice valve shall be measured and paid separately and making good all disturbed surfaces of wall/ floor/ road/ path to match with existing specification all as specified and as directed.
M&L for Cast iron/ductile iron special fittings for spigot and socketed pipes such as bends (any type, radius and angle) socket tapers any type, (straight, bend, increasing, decreasing or double socket etc) Tee pieces, single branch, Y junction, double branch, cross (all sockets or socket and spigot) collers, caps and plugs for upto 150 mm bore pipes complete all as specified and directed.
S&F of cast iron double flanged sluice valve of 150 bore class PN 1.0 confirming to IS 14846/2000 with with high tensile stainless steel spindle with CI wheel, Gun Metal Nuts/rings 'I' bolt, ISI marked including rubber packing complete all as specified and directed. Make : Kirloskar/Upadhyay/BIR as approved by GE.
Material and Labour for brick masonry valve pit chamber of size 900mm x 900mm x 950 mm (internal) complete with PCC (1:3:6) type C-2 for foundation, brick work in Cement Mortar (1:6), 15 mm thick plastering in Cement Mortar (1:4) (internally) including 3.0 mm thick MS plate cover and angle iron frame of 40mm x 40mm x 6.0 mm including coping, 100 mm thick, PCC flooring in 1:2:4 type B-1 and two coats of synthetic enamel paint over a coat of red oxide primer including preparation of surfaces complete with locking arrangement including excavation, returning filling removal of soil complete all as specified and directed.
Supply, installation, testing and commissioning of split air cooled split unit air conditioners 1.5 Ton capacity electric driven single phase of units indoor and outdoor complete accessories including suction and discharge pipe with insulation and cordless remote control unit and with in-built air ioniser and plasma filter for better indoor air quality with BEE 5 Star rating and EER 3.2 of capacity, using Eco friendly refrigerent gas including gas charging, installing at wall including electrical connection for power supply with suitable electrical copper cable, fixing PVC drain pipe for water drainage jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall complete all as specified and directed. Make : Hitachi / DAIKIN / O General as approved by GE(I). Note : (a) The contractor shall furnish the manufactures warranty card to the Engineer in Charge. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed and specified. (c) Rate of provn of angle iron stand/wall mounted platform etc for fixing/supporting the outer unit will be included in quoted rate.
Supply, installation, testing and commissioning of split air cooled split unit air conditioners 2.0 Ton capacity electric driven single phase of units indoor and outdoor complete accessories including suction and discharge pipe with insulation and cordless remote control unit and with in-built air ioniser and plasma filter for better indoor air quality with BEE 4Star rating and EER 3.2 of capacity, using Eco friendly refrigerent gas including gas charging, installing at wall including electrical connection for power supply with suitable electrical copper cable, fixing PVC drain pipe for water drainage jointing suction & discharge line with insulation to indoor unit and all the necessary connection including grouting nut, bolt, washer and fixing of indoor unit at wall complete all as specified and directed. Make : Hitachi / DAIKIN / O General as approved by GE(I). Note : (a) The contractor shall furnish the manufactures warranty card to the Engineer in Charge. (b) The contractor shall make necessary opening on the brick / stone wall for running the refrigerant pipe and cable and making good, finishing to match the surrounding all as directed and specified. (c) Rate of provn of angle iron stand/wall mounted platform etc for fixing/supporting the outer unit will be included in quoted rate.
Supply and fix Voltage stabilizer for automatic operation, single phase having digital display board naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 4 KVA. Make : V Guard / Voltas / Volina as approved by GE(I) . Note Contractor will submit guarantee/warranty certificate from manufacturer.
Supply and fix Voltage stabilizer for automatic operation, single phase having digital display board naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5 KVA. Make : V Guard / Voltas / Volina as approved by GE(I) . Note Contractor will submit guarantee/warranty certificate from manufacturer.
M & L for sub main wiring with two single core 4 Sqmm copper conductor PVC insulated and unsheathed multi-stranded cable (FRLS) including PVC conduit medium grade of 25 mm dia, concealed in walls for sub main connection and 4 Sqmm PVC insulated and unsheathed multi-stranded green colour copper conductor cable (FRLS) as an earth wire to common earth and connected to earth dolly complete all as specified and directed. Make of cable : Finolex/Plaza/Polycab/Havells/Gloster/Grandlay, as approved by GE, Make of conduit : AKG/D-PLAST/FINOLEX/PLAZA as approved by GE
Bharat Sales Corporation
AUTOMATION AND SWITCHGEAR PANELS
M/s CHAUHAN BUILDERS & ENGINEERS
SUSHMANAND ENGINEERING WORKS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .