Loading…
Loading…
Updated dates
Tender Value
Refer Docs
EMD Value
₹68,000
Closing Date
12 Jun 2026, 6:00 pm6d left
GE RnD Pashan
GE RnD Pashan
REPAIR AND MAINTENANCE OF LIFTS INSTALLED AND OTHER MISCELLENEOUS WORKS AT TECHNICAL AREA UNDER GE (I) RnD PASHAN
2026_MES_765571_1
GERD/PSN/TOKEN/18 OF 2026-27
Open Tender
Electrical and Maintenance Works
180 days
GE RnD Pashan
As per tender documents
8 documents required · 8 mandatory
₹500
GE RnD Pashan
₹68,000
Yes
15 May 2026
15 May 2026
15 Jun 2026
15 May 2026
12 Jun 2026
29 May 2026
15 May 2026 - 22 May 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Monthly Periodical inspection and including attending break down complaints/ in case of any Emergency and stand by attendance duty in VIP visit days at ARDE Lab including following complete all as directed for smooth functioning of the lift all as specified and directed :-
(a) Replacements of oil and minor spares like nuts, bolts, control wires and thimbles as required.
(b) Setting /Maintaining control panels, VVF drives and other programable drives and arrange OEM/ Consultant for guidence/repair if necessary.
(c) Maintaing emergency lights, ventilating fan, intercom system, alarm system along with all components of lifts for smooth functionjing of the lift.
(d) Oiling Greasing, servicing of lift Doors, wire ropes.
(e) Testing and serviceablility checking of each lift by authorised person/ Lift Inspector in presence of Engr-in-charge, JE (E/M) and User's representative and test certficate to be produced in duplicate.
(f) Yearly once serviceability test certificate for each lift by authorized person/lift inspector to be produced in duplicate.
Passenger Lifts of catering G+4 floors, 08 passengers capacity, located in admin block of ARDE CSD Canteen side - 01 Nos | 6 | Each Job | - | - |
All as per item No 1 above but Passenger Lifts of catering G+4 floors, 13 passanger capacity, located in admin block of ARDE Main porch (officer's Lift) -01 No ' | 6 | Each Job | - | - | |
All as per item No 1 above but Passenger Lifts of catering G+4 floors, 13 passanger capacity, located in admin block of ARDE Near Binding section side-01 No ' | 6 | Each Job | - | - | |
All as per item No 1 above but Passenger Lifts of catering G+4 floors, 08 passanger capacity, located in admin block of ARDE PLANNING SEC side-01 No' | 6 | Each Job | - | - | |
All as per item No 1 above but Fright lift of catering G+4 floors, 2000 Kg capacity located in admin block of ARDE-01 No '
NOTES FOR SCHEDULE 'A' ITEM NO 1 to 5
a) maint of lifts required to be done in every month, cleaning, greasing, oiling wherever required, checking of all electrical connections in addition standard maintenance as recommended by manufacturer, quarterly & half yearly . The rate quoted by the contractor includes cost of grease, cotton waste, lugs, nut bolts, washers & misc items as directed.
b) Major defects such as hoist motor rewinding and rewinding of thruster motors, bearings, shaft and gear assembly does not includes in the rate quoted.
c) Renewal of spare parts shall be measured and paid seperately under respective items as "Supply only".
(d) The rate quoted is deemed to include for labour charges including taking down of unserviceable parts and fixing only new spares in all respect to keep up smooth functioning of lift and nothing extra shall be admissible.
e) The worker employed by the contractor will report to the concerned AGE E/M /JE E/M twice in month and in emergency breakdown conditions for assignment of job and submit completion/serviceability report on the same day. | 6 | Each Job | - | - | |
M&L for disconnecting and removing from installed position main drive gear assembly for servicing, repair including loading / unloading and transporting to nearest work shop including refixing connecting commissioning and testing in position after carry out necessary repair/ replacement complete all as specified and as directed
Note Spare parts to be renewed shall be measured and paid seperately as "Supply only" | 1 | Each Job | - | - | |
Supply only both side ball bearing with existing size and make as per numbers specified by OEM. Make SKF or equivalent as approved by GE complete all as specified . | 4 | Each | - | - | |
Supply only gears of gear box / gear assembly including testing for without lateral movement and adjustable linear speed with maximum speed complete all as specified and directed by Engr-in-Charge.
Note : Contractor is advised to visit site before quoting the rates. | 1 | Each Job | - | - | |
Supply only both side oil seals of approved make and grade complete all as specified and directed by Engr-in-Charge. | 2 | Each Job | - | - | |
Supply, install, testing and commissioning of lift controller AC variable voltage and variable frequency (VVVF) drive 12 HP / 9 KW suitable for existing specification with starting current 1.2 to 1.5 times of full load power saving and acceptable voltage fluctuation 10 to 20%. The controller mounted in totally enclosed cubicle type with hinged doors on the front as per IS-5133-1969 (Part 1) include protection against the following abnormalities and cut off the power supply, apply the brake and bring the car to a rest in the event of any of the abnormalities occurring and connected accessories to synchronies the system complete including taking down existing unserviceable VVVF drive all as specified and as directed.
Note : Test report for follwing parameters to be submitted by contractor. a) Over current
b) Under voltage
c) Overvoltage
d) Single phasing
e) Phase reversal
f) Earth leakage | 1 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.60 MB
8711.pdf
Tender Documents • 1.76 MB
BOQ_857427.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid