Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.2 LAccepted-Finance | L1 | Accepted-Finance Lowest | |
| 2 | L2₹4.3 L+₹8,870 (2.12%)Rejected-Finance | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹4.3 L+₹15,625 (3.74%)Rejected-Finance | L3 | Rejected-Finance Highest |
Tender Value
₹4.2 L
EMD Value
₹8,493
Closing Date
24 Mar 2025, 3:00 pmClosed
Director CSIR IITR Lucknow
Vishvigyan Bhawan 31 Mahatma Gandhi Marg Lucknow
Electrical wiring and SITC of Split AC new Confocal Microscope room near TDIC Building at Main campus, CSIR-IITR, Lucknow
2025_CSIR_229332_2
IITR/EME-17(29)/2024
Limited
Electrical Works
Item Rate
60 days
Vishvigyan Bhawan 31 Mahatma Gandhi Marg Lucknow
As per NIT and Tender Document
2 documents required · 2 mandatory
₹0
₹8,493
19 May 2025
10 Mar 2025
25 Mar 2025
10 Mar 2025
24 Mar 2025
10 Mar 2025
Amount
SH: Electrical and Airconditioning work
Wiring for light point/ fan point/ exhaust fan point / call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC inslated copper conductor single core cable etc. as required. Group C
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 2.5 sq. mm
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4.0 sq. mm
Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2 Pair
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required. 25 mm
Installation, Testing, Commissioning of wall bracket/ ceiling fittings of all sizes and shapes containing upto two GLS/CFL/LED lamps per fitting, complete with all accessories including connection etc. as required.
Supplying and drawing of UTP 4pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required. 2 run of cable
Supply and Fixing DP Sheet steel enclosure on surface/ recess along with 25/32 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Earthing with G.I earth plate 600mm x 600 mm x6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories and providing masonry enclouser with cover plate having locking arrangement and watering pipe of 2.7 mtr long etc with charcoal/ coke and salt as required.
Providing and fixing 25mm x 5mm copper strip on surface or in recess for connections etc., as required.
Proving and fixing 25mm x 5mm G.I strip on surface or in recess for connection etc., as required.
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including exacation, sand cushioning, protective covering and refilling the trench etc as required. Above 35 sq.mm and upto 95 sq.mm
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. 31/2 x70 sq.mm (38mm)
SITC of 1.5 Ton All wheather inverter Split Air Conditioner with Intelligent heating 3 star rating along with wall bracket for mounting of Outdoor Unit and standard fixing accessories including PVC Flexible pipe upto 3m length of 15mm dia, complete as required.
Supply & fixing of Copper pipe along with cable, drain pipe and insulation for additional length, complete as required.
Supply of 36Watt recess type LED 2X2 Panel light complete as required.
Supply and Fixing 100x50mm uPVC Trunking. complete as required
Supply and Fixing 50mm Divider. complete as required
Supply, Fixing Internal angle 100x50mm. complete as required.
Supply, Fixing End cap 100x50mm., complete as required.
Supply, Fixing joint cover 100x50mm. complete as required.
Supply and Fixing of RJ45 Internet socket complete as required.
Supply and Fixing of RJ11 Telephone Jack complete as required.
Supply & Fixing of PVC mounting Box 1-3 Module complete as required.
Supply & Fixing of PVC 1Mod.front plate. SCW complete as required.
Supply & Fixing of PVC 3Mod.front plate. SCW complete as required.
Supply & Fixing of 16A One way Swicth complete as required.
Supply & Fixing of 6/16A Socket ISI Mark complete as required.
Supply of 70 Sqmm X 3.5 Core Aluminium Armoured XLPE Power cable of grade 1.1KV complete as required
Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2x10 sq.mm + 1x6sq.mm earth wire
Supplying and fixing DP sheet steel enclosure on surface/ recess along with 40 A 240 V "C" curve DP MCB complete with connections, testing and commissioning etc. as required.
Supply of 6Watt Up-down warm white LED Wall light, complete as required.
Lite Links (BID ID -832539)
Reliable Electricals (BID ID -829371)
Lite Links (BID ID -832539)
Reliable Electricals (BID ID -829371)
stage.html
html • 0.04 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .