Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 364 4 FIRDAUS SHABANA MARKET NEW SABZI MANDI JK COLONY ROAD KANPUR 07 | KANPUR NAGAR | UTTAR PRADESH | 208001 | ₹15.1 L Quoted ₹15.3 L | L1 | Accepted-AOC ACCEPTANCE |
| 2 | L2₹15.3 L+₹6,060.50 (0.40%)Rejected-Finance | ₹15.3 L+₹6,060.50 (0.40%) | L2 | Rejected-Finance HIGHER BIDDER |
| 3 | L3₹16.4 L+₹1.1 L (7.14%)Rejected-Finance | ₹16.4 L+₹1.1 L (7.14%) | L3 | Rejected-Finance HIGHER BIDDER |
| 4 | L4₹16.6 L+₹1.3 L (8.52%)Rejected-Finance | ₹16.6 L+₹1.3 L (8.52%) | L4 | Rejected-Finance HIGHER BIDDER |
| 5 | L5₹17 L+₹1.7 L (11.2%)Rejected-Finance | ₹17 L+₹1.7 L (11.2%) | L5 | Rejected-Finance HIGHER BIDDER |
Tender Value
₹18.9 L
EMD Value
₹37,800
Closing Date
24 Jan 2020, 6:00 pmClosed
SH M V SANKAR SE
CWE NAVY VASCO VASCO DA GAMA GOA 403802
SPECIAL REPAIR TO CONVERSION OF LT OH LINE INTO LT UG CABLE AT MO GOA UNDER GE GOMANTAK VASCO
2020_MES_311608_1
85217/E8
Open Tender
Civil Works
Item Rate
180 days
CWE NAVY VASCO
AS PER TENDER DOCUMENTS
9 documents required · 9 mandatory
₹500
Yes
GE GOMANTAK VASCO
₹37,800
Yes
6 Mar 2020
3 Jan 2020
27 Jan 2020
3 Jan 2020
24 Jan 2020
17 Jan 2020
Amount
Taking down old unserviceable ACSR conductor including channels, insulators etc complete all as specified and as directed.
Supply, laying and testing cable XLPE Insulated, screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor, laid in trenches/ ducts or fixed to poles/walls or laid under roads/paths/drains/culverts duly encased in galvanised steel pipe of suitable sizes including cable gland of suitable sizes & aluminium lugs for connection complete all as specified and as directed for following size
(a) 16 sqmm 4 core
(b) 35 sqmm 3.5 core
(c) 95 sqmm 3.5 core
(d) 185 sqmm 3.5 core
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in hard/dense soil all as specified and as directed.
Excavation in trenches not exceeding 1.5 m width and not exc 1.5m in depth getting out in soft disintegrated rock all as specified and as directed.
M&L for sand cushion in trenches for cable protection complete all as specified and as directed.
Supply and lay PCC cable cover class LV type 1 flat size 250mmx150mmx40mm all as specified and as directed.
M&L for returning, filling in including spreading levelling watering and well ramming in layers not exceeding 25 cm in thick using excavated hard/dense soil all as specified and as directed.
M&L for removal of surplus soil to a distance not exceeding 50 m and depositing where directed.
M&L for laying GI pipe 40mm dia light grade for the protection of cable all as specified and as directed.
M&L for laying GI pipe 80mm dia light grade for the protection of cable all as specified and as directed.
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50x50x5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars, multifunction meter, LED lamps and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement, structure treated under 8 - tank metal treatment process and duly powder coated, complete and comprising of and including the following all as specified and as directed :- BUSBAR :- (i) Copper bus bar of size 50 x 10mm having current rating of 500 Amps, 440 volts supported on non hygroscopic fibres and brass screws for mounting - 04 Nos INCOMER (a) Supply and fixing MCCB 4 pole 440 Volts of 400 Amps - 01 No
INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B -03 Nos (b) Supply and fixing multi function meter, including CT having CTR 50/5 - 01 No (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) OUTGOING FEEDERS (a) Supply and fixing MCCB 4 pole 440 Volts of 250 Amps - 01 No (b) Supply and fixing MCCB 4 pole 440 Volts of 200 Amps - 01 No (c) Supply and fixing MCCB 4 pole 440 Volts of 100 Amps - 02 Nos
Supply, install, testing and commissioning of LT Feeder pillar Box AC 415 V, 50 HZ 3 Phase 4 wire of suitable size for accommodating the following accessories totally enclosed self supporting structure / cubicle, fully compartmentalized type, weather proof, protection IP 52, suitable for outdoor use, with bottom cable entry with suitable cable glands structure made out of 3.15 mm thick CRCA steel sheet of suitable size with angle iron frame work and legs of ISA 50x50x5 mm, with four legs grouted to PCC (1:2:4) type B1, foundation block with suitable mounting arrangement for bus bars, multifunction meter, LED lamps and MCCBs, with sloping canopy at top, double hinged doors at front with suitable locking arrangement, structure treated under 8 - tank metal treatment process and duly powder coated, complete and comprising of and including the following all as specified and directed :- BUSBAR :- (i) Copper bus bar of size 50x6mm having current rating of 300 Amps, 440 volts supported on non hygroscopic fibres and brass screws for mounting - 04 Nos
INCOMER (a) Supply and fixing MCCB 4 pole 440 Volts of 250 Amps - 01 No INDICATING DEVICES (a) Supply and fixing LED Indicating lamps for Main Supply indicating R, Y, B -03 Nos (b) Supply and fixing multi function meter, incl CT having CTR 50/5 - 01 No (Parameters : V, A, F, PF, kW, kVA, KWh, kVAh, kVARh) OUTGOING FEEDERS (a) Supply and fixing MCCB 4 pole 440 Volts of 200 Amps - 01 No (b) Supply and fixing MCCB 4 pole 440 Volts of 100 Amps - 02 Nos
Supply & Fixing sheet moulding compound junction box (SMC) suitable for terminating 2 Nos 4 x 6/10/16 Sqmm UG cable including one in Nos MCB SP 10A including cable glandes- 2 Nos, and two way connector 1 No, including dismantling old one.
Shine Enterprises
Pan Electricals
Mehta and Co.
Sai Supreme Constructions
SURAT SINGH AND SONS
NATIONAL ENGINEERING CORPORATION
SLB Enterprises
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .