Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance FLAT NO 93 POCKET 03 SECTOR 11 DWARKA NEW DELHI 110 075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | Admitted-Finance |
| 3 | Admitted-Finance D 662 WZ 1598 R 1 NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹82,800
Closing Date
27 Feb 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE AF SUBROTO PARK
GE AF SUBROTO PARK DELHI CANTT - 110010
ADDN ALTN TO PMO SECTION OF HQ WAC BUILDING NO P96 AND PROVN OF WALL STORAGE UNITS AND CERTAIN MISC WORKS SERVICES OF HQ WAC UNDER GE AF SUBROTO PARK
2021_MES_410194_4
GE/SP/TOKEN-80/2020-2021
Open Tender
Civil Works
Item Rate
180 days
GE AF SUBROTO PARK DELHI CANTT
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE AF SUBROTO PARK
₹82,800
Yes
5 Mar 2021
13 Feb 2021
1 Mar 2021
13 Feb 2021
27 Feb 2021
13 Feb 2021
13 Feb 2021 - 13 Feb 2021
75 days
Amount
M & L for demolition of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing un serviceable tiles / debris to the out of MOD Land premises , Complete all as specified and directed by Engr-in-Charge.
M & L for 25 mm thick Plain Cement concrete type B-1, (1:2:4 ) (20mm graded aggregate) as in floors / sub base to the floor , complete all as specified and directed by Engr-in-Charge.
M&L for vitrified Dark shade/ double charge ceramic tiles 10mm thick (square/rectangular) polished, area of each tiles exceeding 0.36 sqm but not exc 0.42 sqm , in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 15 mm th screed in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L for vitrified double charge ceramic tiles 8 to 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, as in Skirtings/ dados etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match etc over 10 mm th rendering in cement mortar 1:4 complete all as specified and as directed by Engineer-in-Charge.
M&L Glazed printed/ coloured ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over 10 mm thick rendering in cement mortar 1:4 complete all as specified and directed by Engineer-in-Charge.
M & L for Dismantling of wall , ceiling baording , any description , fixed in any position with nails complete all as specified and directed by Engr-in-Charge.
S & F in repairs 'E' board(Design: LACK & hILL) MAKE: 605x605x4 mm thick, white pre laminated set embosed reinforced designer ceiling board tiles of approved texture at all height laid on hot dipped galvanised iron imposed grid with 24 mm wide T-sectionexposed flanges which shall be power coated white. The frame work shall be comprise of main runner made from 0.33 mm thickgalvanised steel sheet and of size 24 mm X32mmX300 mm board spaced at 120 mm maximum centre to centre, hangers of GI wire4 mm dia to be fixed by approved rawal plug level and fasterners and screws etc.,The last hanger at the end of each main runner shall not be greater than 450 mm from adjecent wall , flushing fitting of 1200 mm longer cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross tee longer than 600 mm to be supported independently . 600mm long cross tee centrally between the 1200 mm cross tee(with double stitching) to be interlocked between main runners at 600 mm centre to centre from 1200X600 mm modules cross Tee longer thyan 600 mm to be supported independently . The perimeter wall angle shall be 0.45 mm thick GS sheet of size 19 mm X 19 mm and 300 mm long of white colour , incl demolition/ dismantling of old wall/ ceiling boards , any thick fixed to any frame / fillet work, all as per manufacturer's instructions complete all as specified and directed by Engr-in-Charge.
Providing and fixing 10mm thick plaster of Paris ceiling (Gypsum anhydrous) to sunk or raised moulding to flat surface over metal frame work incl reinforced with G.I. wire mesh & Gl frame work for seamless ceiling comprising of Gl perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre to centre/ intermediate channel 0.9 mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx. 900 mm centre to centre with Gl cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre & Hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long incl taking down old ceiling and two coat of OBD over finish surface complete all as specified and directed by Engr-in-Charge.
Taking down frame or Chowkhats with shutters (w/o taking off shutter from the frame) of any description exc 1.50 sqm complete all as specified and as directed by Engr-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frames) n.exc. 1.5 sqm complete all as specified and directed by Engr-in-Charge.
Taking down shutters of any description exc 2.00 sqm each complete all as specified and directed by Engr-in-Charge.
S & F flush shutters,40 mm thick solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed by Engr-in-Charge.
M & L for Preparation of new or previously untreated surfaces of wood and wood based surfaces over 10 cm in width or girth and applying two coats of varnishing finishing coat with synthetic varnish over filler coat of wood filler liquid transparent complete all as specified and as directed by Engr-in-Charge.
M&L for powder coated aluminium wk as in partition wall/ door Chowkhats/ windows/ ventilatorts, shutters using JINDAL section single groove any suitable section conforming to IS-733 and IS-1285 amd coating grade A-153 confirming to IS-1868 fixed with rawl plug and screw or with fixing clips with expansion hold fasteners including necessary jointing cleats, glazing clips, rubber packing anodised aluminium snap beading packing anodised aluminium snap beading screws, powered coated anodised aluminium fittings etc gap of junction at top, bottom & sides to be filled with silicone fillers/Neoprene felt etc complete all as specified and directed by Engr-in-Charge.
S & F Powder coated (thick ness of powder coated not less than 50 micron) of any colour Anodised aluminium door shutters,aluminium section weighing 0.55 kg/m including necessary joining cleats,glazing clips, ruber neoprene packing,handles 2 Nos in each door, hinges,anodised aluminum snap beading screws etc. complete all as specified by Engr-in-Charge.
S & F for Powder coated (thick ness of powder coated not less than 50 micron) Anodised aluminium window and ventilator shutters, side hung type without sash , aluminium sections weighing 0.55 kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws anodised aluminium fittings such as peg stays 150 mm long (1no.) hinges type b-21 100 mm long (2 Nos) suitable handle (1no.) , etc. complete all as specified and directed by Engr-in-Charge.
S&F aluminium powder coated Deco grill in approved design weight not less than 1.7 Kg/Sqm incl profile etc complete all as specified and directed by Engr-in-Charge.
S&F Galvanised mild steel wire cloth, 0.56mm nominal dia of wire and average width of aperture 1.18mm and fixed with tinned tacks, or galvanised wire staples complete all as specified and as directed by Engr-in-Charge.
S & F 12 mm Block boards, grade 2 quality, interior grade, decorative type with decorative veneers on both side , complete all as specified and directed by Engr-in-Charge.
S&F vinicen blind including complete set all as specified and colour approved by GE. (Make- Vista)
S & F Mortice latch with two levers (vertical type) , brass body , length of latch 75 mm , complete all as specified and directed by Engr-in-Charge.
S & F Brass handles, cast type, polished bright size of handle 100 mm complete all as specified and as directed by Engr -in - Charge
Double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed by Engr -in-Charge
S&F 100 mm long butt hinges medium weight cold rolled mild steel alloy with galvanized complete all as specified and directedby Engr-in-Charge.
S&F 100 mm long Aluminium handles, cast type, anodised complete all as specified and directed by Engr-in-Charge.
S&F of 75 mm long Aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed by Engr-in-Charge.
S&F 300 mm long Aluminium alloy, anodised , sliding tower bolt with hasp and staple (bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed , complete all as specified and directed by Engr-in-Charge.
S&F Aluminium (extruded section body door closer hydraulically regulated, designation No 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80kg and fixed complete all as specified and as directed by Engr-in-Charge.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern) excluding flushing cistern and flush pipe and including P or S trap complete all as specified and as directed. Make : Jaquar / Hindware / Parryware
Supply and fixing of 45mm thick modular partition workstation size of each seat (1200mm x 600mm x 1200mm height ) made out of tiles base frame work of welded powder coated CRCA steel (MS grade D formed into 1.5mm C channels) to cover the frames will be powder coated 1mm thick CRCA metal sheets . The partition will be made of by two 6mm thick MDF with 0.6mm thick decorative laminate on top as approved fix on CRCA frame work. workstation having glass partition on top of the table and Pin board face on inside above worktop. Trims and caps will be made of aluminium alloy (Grade He-9 63400) of 1.2 mm thickness, powder coated to the desired colour/finish incl Three drawer mobile pedestal (450mmX450mmX715mm ) Using 18mm thick prelaminated particle boards with same texure as workstation . Drawers shall have channel arrangement for smooth operation, with best quality stainless steel handle in brush finish and Multi Drawer Lock Zinc alloy die-cast chrome finish with two keys, with powder coated CRCA Keyboard tray and powder coated CRCA CPU trolly complete all as specified and directed. Make: Cat No ESC/WS/009 of Empire Safe Co/ Royal Kaos/ Durain or Equivalent
Supply and Installation of Modular Wall mounting Storages as per approved design using 18/19mm prelaminated particle board middle wall at max spacing 600mm C/C overall height not less than 900mm and depth 450mm with openable 18/19mm pre-laminated shutters fixed to the storage with the help of auto close hinges 110 Degree, including machine pressed PVC edge banding 2mm thick in matching colour, Zinc alloy die-cast chrome finish cam lock/desk drawer locks for each shutters , brushed SS handle on each shutters etc; fixed on wall as directed by manufacture complete as directed and specified by Engr-in-Charge. Note : All joints of board to be made with help of CRCA cleat. For measurement, only front of storage will be measured complete all as specified and directed. Make :Empire Safe Co/ Royal Kaos/ Durain or Equivalent.
S&F sinks made of stainless steel 1.0 mm thick kitchen or laboratory with plugs, washers and wastes; including bedding in cement mortar on to dwarf wall or including fixing cantilever brackets and connecting union to pipe, overall size 915mm x 420mm bowl size 410mm x 330mm x 160mm complete all as specified and directed by Engr-inCharge.
S&F in repairs stainless steel rack for kitchen utensil made out of 22 gauge sheet & overall size 900mm x 750mm fixed to wall with screws complete all as specified and directed by Engr-inCharge.
Surfface dressing n.exc 15 cm deep in hard and dense soil complete all as specified and directed by Engineer-in-Charge.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, all as specified and directed by Engr-in-charge.
M & L for PCC (1:3:6) type c2 using 4 mm graded stone aggregate as in foundation etc ., complete all as specified and directed by Engr -in - Charge.
S&F in repairs Rolled mild steel in roof trusses / purlins / rafters (Circular/RHS/SHS) (framed), trussed, fastenings and heavy bracket framing (beam, tee, angle, channel or flat sections including cleats, brackets etc) conforming Fe-410W(Gde-E-250 quality 'B' , incl dismantling of MS work in any position, complete all as specified and directed by Engineer-in-Charge.
M&L preparation of steel surfaces and apply two coats of synthetic enamel paint over a coat of primer as directed by Engr-in-charge
S & F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified and as directed by Engr-in-charge
M&L 75 mm thick Cement concrete 1:4;8 type D2 using 40 mm graded stone aggregate as in sub base for floor finished complete all as specified and as directed by Engr-in-charge
M & L for 60.00 mm thick , M-40 grade Coloured Machine pressed precast concrete interlocking paver block any shape (Factory made) and size set with grey cement and pigment confirming to IS 15658-2006 over sand cushioning complete all as specified and as directed by Engr-in-charge
M/L for Sand filling under floors incl or in foundations including watering and consolidation n.exc 25 cm thick complete all as speicified and as directed by Engr-in-charge
Excavation trenches n.exc 1.50 m wide and n.exc 1.50 mtr in depth for foundation, etc., n.exc 10 Sqm on plan and n.exc 1.50 mtr depth and getting out in hard/ dense soil complete all as speicified and as directed by Engr-in-charge
Removing excavated materials , surplus materials exceeding1.50 km but not exc 5 km away from MD land and depositing where directed at a level n.exc 1.5 m above the starting point complete all as speicified and as directed by Engr-in-charge
M&L Cement concrete 1:4;8 type D2 using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as speicified and as directed by Engr-in-charge
Returning, filling in incl spreading leveling, watering and well raming in layers n.exc 25 cm in soft/loose soil concrete all as speicified and as directed by Engr-in-charge
Brick work with sub class 'B' bricks, straight or curved on plan exc 6m mean radius built in CM 1:4 concrete all as speicified and as directed by Engr-in-charge
M&L for 15 mm thick cement plaster in cement mortar 1:4 on concrete or brick surface and finished even and smooth w/o using extra cement complete all as specified and directed by Engr-in-charge
M&L for preparation of new plastered surface of walls and applying two coats of cement base paint over a coat of lime wash complete all as specified and directed by Engr-in-charge
Taking down carefully copper/aluminium point wiring light ,fan, light fittings,socket or power complete, such as switches, ceiling roses, pendents, regulators, sockets etc.removing materials to store for keeping in safe costudy or for taking credit (credit for above items should be made as per conditioned separately) and making good disturbed surface of walls, floors etc. complete all as specified and directed by Engineer-in-Charge.
M&L for point wiring with S/C of FRLS PVC insulated unsheathed IS-694 marked 1100 V grade cable multi stranded copper conductor of size 1.5 sqmm drawing through in and including PVC conduit size of not less than 20mm including conduit fittings and acessories concealed in wall / ceiling or surface conduit wiring on ceiling /wall terminated in sheet metal box along with provn of earth wire of PVC insulated, unseathed, 1100 V grade cable multi stranded FRLS IS - 694 markd copper conductor of size 1.5 sqmm all as specified and directed by Engr-in-Charge. Note : Cost of for cutting chaising and making good to disturbed surface all as to match with existing surface are deemed to be included in quoted rate.) One light point controlled by one switch one way. Rate are exclusive of modular type flush metal box and cover plate.
M&L for point wiring with 1.5sq mm PVC insulated S /C unsheathed 1100 v grade IS -694 stranded copper conductor FRLS cable drawing including and into PVC conduit not less than 20 mm dia in wall / surface including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire connected to main earth dolly for one socket point independent controlled by one switch complete all as specified and directed by Engineer in Charge.
All as per srl item 54 above but for one C/ fan/Exhaust fan/wall fan point controlled by one switch one way.
All as per item No 54 above but for one 3 pin 5 amps socket outlet on indipendent board with other switchs.
All as per item No 54 above but for one 3 pin 5 amps socket outlet on the same board with other switchs.
All as per item No 54 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size
All as per item No 54 above but with 2.5 Sq mm cable for Independent bd one 3 pin 15 Amps socket outlet including single core 2.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FR LS cable for continuous earth wire connected to gang box of required size
M&L for point wiring with 2.5 sq mm PVC insulated S /C unsheathed 1100 v grade IS -694 stranded copper conductor FRLS cable drawing including and into PVC conduit not less than 20 mm dia in wall / surface including S/C 1.5 Sq mm PVC insulated copper conductor unsheathed 1100 v grade IS -694 FRLS cable for continuous earth wire connected to main earth dolly for one power point independent controlled by one switch complete all as specified and directed by Engineer in Charge.
S&F in replacement switch piano, flush type single pole, one way, 5 Amps, 240 volts all as specified and directed at site
S&F switch piano 15 amps flush type single pole one way complete all as specified as directed.by Engr-in-Charge
S&F socket outlet flush type 5 pin 6 amps complete all as specified as directed.by Engr-in-Charge
S&F socket outlet 2 in 1, 3/5 pin 16 amps flush type complete all as specified as directed.by Engr-in-Charge
Supply and fixing of MCB distribution board with Bus bar 200A neutral link , earth bar made out of CRCA mild steel sheet surface mounting SPN 12 way 230 volts double door type regal gray horizontal type complete all as specified and as directed by Engineer-in-Charge.
S&F TP isolator 63 amps complete all as specidied and directed by Engineer-in-Charge.
S&F Isolator MCB 6 to 40 Amps SP 10 KA complete all as specidied and directed by Engineer-in-Charge.
S&F in replacement of LED ceiling light 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
M&L for Sub main wiring with under mantioned runs of single core PVC insulated but unsheathed FRLS cable of specified size with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia)along with fittings and accessories all fixed concealed on wall and surface on ceiling and also including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed by Engineer in charge. (2 runs of main cable one run of earth wire one run of PVC pipe will be measured as an one run) (a) 2 Run of 6 Sqmm cable and one run of 6 sqmm cable.
S&F modular switches 6 amps single pole one way complete
S&F modular socketes out let 6 amps 5 pin complete.
S&F modular switches 20 A x Mega single pole one way complete
S&F modular socket out let 20 A 3 pin combined shuttered complete.
S&F Step fan Speed regulator 5 steps-2M complete
S&F modular white cover plate with frame 8 modular complete. Make :- Legrand/Crabtree/Anchor
S&F flush mounting boxes 8 modular complete. Make :- Legrand Cat No 689042 or its Equivalent Crabtree/Anchor
S&F modular white cover plate with frame 6 modular complete. Make :- Legrand /Crabtree/Anchor
S&F flush mounting boxes 6 modular complete. Make :- Legrand /Crabtree/Anchor
S&F modular white cover platewith frame 4 modular complete.
S&F Flash metal boxes 4 modular complete
S&F modular white cover plate with frame 3 modular complete Make :- Legrand /Crabtree/Anchor
S&F flush mounting boxes 3 modular complete. Make :- Legrand /Crabtree/Anchor
S&F modular white cover plate with frame 1 modular complete. Make :- Legrand /Crabtree/Anchor
S&F flush mounting boxes 1/2 modular complete. Make :- Legrand /Crabtree/Anchor
S&F flush mounting boxes 1/2 modular complete. Make :- Legrand /Crabtree/Anchor
Supply and fixing in replacement of factory fabricated sheet steel enclosure, phosphatised, power painted, single pole and neutral with a two pin and earth plug and socket complete with one single pole MCB 20 amp, 240 volts, 10KA complete all as specified and directed by engineer-in-charge.
S&F in replacement of LED ceiling light 34 watt 2x2 recess LED, 6000 K luminaire having glare free symmetrical illumination Complete all as specified and directed by Engineer-in-Charge.
Supply & fix load line vertical distribution board 'A' frame made out of CRCA 2mm thick mild steel sheet,double door, surface/conceiled mounting TPN 4 way 415 volts 250 Amps rated bus bar and stove enamels dust and vermin proof suitable for TP/FP 'A' frame MCCB of 250 Amps =01 No and MCB's for outgoing comlete all as specified and as directed by Engineer-in-Charge. Note :- MCCB and MCB's shall be measured and paid seperately.
Supply & fix MCCB FP 250 Amps, 415 volt adjustable thermal release breaking cap 16 KA complete all as specified and as directed by Engineer-in-Charge. Make-Havells/L&T/C&S
Supply & fix MCCB FP 250 Amps, 415 volt adjustable thermal release breaking cap 16 KA complete all as specified and as directed by Engineer-in-Charge. Make-Havells/L&T/C&S
S&F MCB SP 6 to 40 Amps 10 KA, 240 volt 'C' Series all as specified and directed by engineer-in-charge.
Supply & fix sheet metal enclosure for DBs double door, SPN,8 way,415 volts with 200 Amps rated bus bar suitable for fixing of MCBs complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing MCB SPN 63 Amp , 240 volt, 10 KA all as specified and directed by engineer-in-charge. Make - Havells/legrand/schinder
Supply and install hi wall split units indoor/outdoor capacity of 1.5 Ton complete unit copper tube type with cordless remote control unit and with in built air ioniser and Plasma filter for better indoor air quality with minimum 5 star rating and EER 3.2.of capacity 1.5 Ton fitted on wall and out door to be fixing on roof/wall at requirement place including all necessary elecrical connections, bolting , nuts , supporting stand clamping, 3 core copper cable upto 5 mtr , cooling tube upto 5 mtr , drain water pipe 3 mtr, etc all as specified and directed by Engineer -in -Charge. Make : Voltas/LG/Blue star
Supply and fix floor/wall mounted Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 5.0 KVA including fixing on wall and necessary electrical connections all as specified and directed by Engr-In-Charge. Make: Blue gurd/voline
Supply & Fix single pole and neutral sheet metal enclosure with a two pin and earth plug and socket complete with one single pole MCB 20-32 amps complete fixing on wall all as specified and directed by Engineer-in-charge Make : Havells/L&T/Standerd
M&L cross arms bracings suppots clamps and back plates fabricated from structural steel sections including nuts bolts washers welding bending cold or hold drilled holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat one under and one finished coat of paint for installation of condesning unit on the wall / ground complete all as specified and as directed by Engineer-in-charge
S&F low density polyehylene pipes (LDPE) of pressure rating 6 kg / cm2 drain pipes of size 40mm from indoor unit to exist point as per design including accessories clmps fastners complete all as specified and as directed by Engineer-in-charge
M&L laying of copper tubing of dia 1/2" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
M&L laying of copper tubing of dia 1/4" including insulation and brazing work complete all as specified and as directed by Engineer-in-charge.
Suplly, & Fixing of 3 core flexible copper cable of size 2.5 Sq mm 1100 V grade complete fixing on wall by clamping/securing including connections all as specified and as directed by Engineer-in-charge Make : Havells/Polycab/Anchor
Supply and fix of MCCB, 415 volts, 3 pole adjustable thermal setting type 25 KA, 125 Amps complete all as specified and as directed by Engineeer-in-charge. Make : Havells or eqvnt of L&T/C&S/Legrand
S&F in repairs MCB Triple pole and neutral 6 to 32 Amps working on 415 volts 50 Hz AC supply, 10 KA 'C' sevies complete all as specified and as directed by Engineeer-in-charge. Make : Havells/L&T/C&S/Legrand
S&F in repairs MCB single pole 6 to 40 Amps working on 240 volts 50 Hz AC supply, 10 KA 'C' sevies complete all as specified and as directed by Engineeer-in-charge. Make : Havells/L&T/C&S/Legrand
M&L Design, development, supply commissioning & testing EHCC certified ground tubular effective Tripot type chemical earthing system (CPRI tested for 15 KA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit of the standard size comprising of 25mm x 3 mtr long copper rod as primary conductor and hollow pure copper tube of dia 50mm x 3 mtrs long as secondary conductor to install with suitable connection terminal conforming to IS-3043:1987 specification, hoghly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation 02 Bags / 60 Kgs minimum or sufficient quantities required as per site complete including FRP earthing pit clause suitable cover, material and labour including testing after completions and result should be less than one Ohm complete all as specified and as directed by Engineer-in-charge. Note:- Excavation for earthing in any surface hard/rock/soft soil for required length by using rock driller machine/other eqpt is inclusive in quoted rate and necessary earthing pit 60x60x6cm also inclusive in quoted rate.
M&L for copper strip 20 x 3 mm with saddle and fixing screws and and connected as per site requirement complete, all as specified and as directed by Engineer-in-charge.
S&F of sub main wiring with two single core PVC insulated unsheathed cable 1100 volts FRLS grade with milti strand copper conductor and drawn through and including PVC conduit along with continuous earthing wire by in green colour complete on surface/concealed and connected to common earth dolly of the following size :- (a) 10 Sq mm (4 single run of 10 sqmm and one run of 10 sqmm as earth wire) Note:- Three run of PVC cable and one run of PVC conduit shall be measured as one unit length.
Supply, installation, commissioning of water cooler fully stainless steel electric driven single phase having approximate storage and nominal cooling capacity 150/150 ltrs (or nearest higher size) with minimum 5 star rating suitable for CFC free refrigerant single phase 230 V, 50 Hz complete with provision of drain water pipe of suitable dia and accessories complete all as specified and as directed by Engineer-in-charge. Make : Blue Star/ Sidwal / Usha/ Voltas
M&L plug top 3 pin 15 amps complete all as specified and as directed by Engineeer-in-Charge.
S&F GI tubing medium grade 20mm with all fittings complete laid in trenches / on walls / on ceiling/ roof etc including necessary suitable size of MS clamps/ sadding on walls / ceiling etc complete all as specified and as directed by Engineeer-in-Charge. Make : JINDAL/TATA/PRAKASH SURYA
S&F gun metal globe or gate valve with iron wheel head screwed both ends for iron pipe 20mm dia complete all as specified and as directed by Engineeer-in-Charge. Make : Sant/ Kartar/ Zoloto
shiva enterprises
J D ENTERPRISES
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .