Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.1 LAccepted-AOC | L1 | Accepted-AOC lowest tenderer | |
| 2 | L2₹7.6 L+₹35,475.50 (4.88%)Rejected-Finance | L2 | Rejected-Finance Other than lowest tenderer |
Tender Value
₹10.1 L
EMD Value
₹20,200
Closing Date
25 Feb 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE(AF) B/R Chakeri Kanpur
GE(AF) B/R Chakeri Kanpur
ADDITION ALTERATION TO UTILITY COMPLEX AT 7 AFH KANPUR CANTT
2022_MES_504185_1
GE(AF)/CHK/T-48 OF 2021-22
Open Tender
Civil Works
Item Rate
GE (AF) B/R Chakeri
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE(AF) B/R Chakeri Kanpur
₹20,200
Yes
22 Mar 2022
28 Jan 2022
4 Mar 2022
28 Jan 2022
25 Feb 2022
11 Feb 2022
60 days
Amount
Demolition of brick work or rubbled stone masonry including all qoins arches , pillars etc built in cement mortar complete all as specified and directed.
M & L for brick work with fly ash bricks, straight or curved on plan exc 6 m mean radius, built in CM (1:6) complete all as specified and directed
M & L for 7 to 8 mm thick non skid ceramic coloured joint free tiles square or rectangular of size exceeding but exceeding 0.11 sqm but not exceeding 0.18 sqm in floors laid over and including 15 mm thick screed bed in CM 1:6 and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles including dismantling of old tiles and removing the same from MD land complete all as specified and directed.
M & L for 7 to 8 mm thick glazed coloured ceremic joint free tiles in vertical surface of size 600 mmX300 /450mm x 300 mm or as required, set over and cncluding 10 mm thick backing coat in CM (1:4) and jointed in neat cement slurry and pointed in white or coloured cement tomatch shade of tiles including dismantling of old tiles and removing the same from MD land complete all as specified and directed.
Dismentaling of corrugated AC sheet in roof covering complete all as specified and directed.
S & F 0.50 mm thick pre painted galvalume aluminium zinc coating GI based corrugated steel of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Taking down cement plaster on brick walls including raking out joints hacking for key scrubing down with water etc.
M & L for rendering 15 mm thick in cement mortar (1:6) finished even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in CM(1:4), finishing surfaces even and smooth without using extra cement, complete all as specified and as directed.
M&L for preparation of newly plastered surfaces of walls including cornices plaster etc and applying two coat oil bound distemper over a coat of primer complete all as specified and directed.
M & L for applying two or more coat coat of 100% premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance , dirt resistance exterior paint of required shade(company depot tinted) with siliconadditive @ 1.43 litre/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm over new surfaces complete all as specified and directed.
Demolition of PCC not exceeding 15 cm thickness in floors, roofs or pavings and throwing debris at low lying area not exceeding 1 km complete all as specified and directed
M & L for 100 mm thick PCC (1:3:6) type B-2 using 40 mm graded aggregate as in floors, pavings, spike rolling to surface or making impressions of expanded metal, whilst the concrete is green complete all as specified and directed
S & F aluminim dividing strips of size 38 mm width 1.5 mm thick complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in plinth protcetion and couetyard, laid in slope (1:40) finished the surfaces even and smooth with out using extra cement complete all as specified and directed.
Dismantling structural steel work including doors, gates, cattle traps etc, but excluding framed truss etc.
M & L for mild steel framed work as grills, grating, etc. with ends of bar shouldered and/or riveted or forged into Spikes, Framed Guard Bars and Similar Work, etc. conforming to Fe-290 Gde E-165 including all necessary drilling, bolting or riveting, etc., complete all as specified and as directed.
S & F steel work as in strusstes, purlins, rafters etc complete all as specified and directed.
M & L for preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enameled paint over a coat of red oxide complete all as specified and directed.
M & L for granite work (of any type) (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking plat- forms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite over and including 15 mm thick screed bed in CM ( 1:4 ) including dismantling old stone slab complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded. complete all as specified and directed.
S & F steel windows with side hung shutters including projecting type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded. complete all as specified and directed.
S & F steel ventilator with top hung shutter including hinges, steel peg stay, complete all as specified & directed.
S & F stainless steel wire cloth, 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples. complete all as specified and directed.
S & F 3 mm thick sheet glass ordinary quality glazing with oil putty or wooden beads in square not exceeding 0.5 Sqm in each pane all as specified and directed.
S & F 15 mm bore tubes medium grade galvanized with all fitting and fixed complete to walls and ceilings or laid in floors of any length including taking down old steel tubing and removal from site, complete all as specified and as directed
S & F in repair fancy type CP bib taps(long body) cast copper alloy chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule 15mm bore complete all as specified and directed.
M & L for 25 mm thick PCC (1:2:4) type B-1using 20 mm graded stone aggregate, as in sub base of floor tiles etc, complete all as specified and as directed.
S & F 110 mm bore PVC (SWR) pipe single socket in any length with rubbepr ring joints fixed to walls with MS flat iron clamps with 50 mm x 6 mm and 16 mm dia round bar stay of required shape and size inclduing drilling holes and embedded in CM (1:3) surface finished complete all as specified and directed.
S & F in repairs steel rolling shutters without ball bearing as specified including top cover anchoring rod hasp and staple and one coat of primer erected in position as indicated of 1.25 mm thick laths, push pull or manual type complete all as specifed and directed.
S & F single phase 2 wire token based prepaid electronic Energy Meters class Accuracy 1, 1x240 Volt, 10-60 Amps LCD display with KWH PF, 1, V for all three months and so on for one full year. Meter should be BIS as per IS-15884 with load and current limiting feature including provision of Optical for data downloading complete all as specified and directed.
S & F PVC/polycarbonate rectangular block for mounting of electric meter of any rating with 3 mm thick plastic laminated sheet cover of size 350 mmx300mmx50mm complete all as specified and directed.
M & L for sub main wiring with two runs of single core 4 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable drawn and PVC rigid conduit 2 mm dia with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 2.5 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring all as specified. Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run unit.
Taking down ceiling fan of any size, any make fixed/hanged at different locations in Air Force Station, dismantling the fan complete cleaning and re-assembling the same including placing Anti Suicide down rods, split pins flexible cooper cable of size 23/0.0076 twin core, suitable length and refixing the ceiling fan on the same location in original position, testing and commisioning of fan from smooth running as per entire satisfaction of Engr-in-Charge. Note: (i) Quored rate by tenders of anytimne of the schedule in inclusive of listing shown the ceiling fan from the position and re-fixing /hanging in position connecting and resting complete. (ii) Anti Suicide down rods replacement of spaces shall be measured and paid repaterly under appropiate items. (iii) Old MS Down rods to be deposited at AGE E/M Store Yard.
S & F capacitor of 3.15 Mfd including fixing complete and including necessary items such as sleeves etc complete all as specified and directed.
S&F Step type electronics fan regulaotr AC 220V Single phase complete all as specified and directed.
S&F metallic clamps for hanging of ceiling fans with bolts & nuts, split pin etc., complete all as specified and directed.
S&F rubber replaced of suitable size for ceiling fans of any size and male complete all specified and directed.
S&F 260 mm Gold Life Anti MS Down rod (Anti Suicide Fan Rod) white/brown clour ceiling fans of any size and make complete all specified and directed.
S&F 300 mm Gold Life Anti MS Down rod (Anti Suicide Fan Rod) white/brown clour ceiling fans of any size and make complete. Make Safety solutions Industries/Gold Life Smart Fan down rod complete all specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5m in depth for laying of UG Cable including getting out in soft/loose soil complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as specified and directed.
Removing excavated material not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above starting point complete all as specified and directed.
M & L for dry clean Ganga sand spreading & leveling in trenches for cushioning of UG cable complete all as specified and directed.
M & L for sub class old size Brick in trenches for cable protection of LT Cables complete all as specified and directed.
S & F in replacement of unserviceable XLPE insulated , screened, PVC bedded galvanised steel strip or wire armoured electric power cable heavy duty with aluminium conductor 1100 volts grade having cross sectional 70 sq mm 3.5 core, laid in trenches/ducts /encased in GI pipe /fixed to pole complete all as specified and directed.
S & F 50 mm dia GI pipe light grade laid in trenches /fixed on pole / wall with required size of flat iron clamp duly painted with two coats of super enamal paint over a coat of red oxide primer complete with bolts, nuts and washers of complete all as specified and directed.
Taking down carefully point wiring from existing place (light/fan, socket or power points complete) with all fittings such as switches, sockets ceiling rose , pendant holder, fitting and fixtures , MCB DB’s , MCB, Main switches, call bell etc and making good to disturbed surface to wall ,floor etc to match with existing surface either by using same colour distemper or white colour wash all as required and directed.
M & L for point wiring PVC FRLS insulated and unsheathed copper stranded conductor cable of size 1.5 Sq mm , 1100 V concealed wiring drawn in and including 20 mm dia non metallic PVC conduit medium complete including cast iron/pressed steel terminal box 1.6 mm thick of required size Bakelite sheet 3mm thick for mounting switch , socket brass screws and washer including PVC insulated and unsheathed solid copper wire of size 1.5 Sq mm used as continuous earth wire for the following :-
One light /fan point controlled by one, one way switch
One 5/6 Amp socket on the same board with other switch
One 5/6 Amp socket on independent board.
One 3 pin 15 Amp socket independent but with 2.5 q mm PVC insulated unsheathed copper stranded conductor and earth wire with 1.5 Sqmm
S & F in replacement switch piano type 240 V, 5 Amp , SP one way flush type complete all as specified and directed.
S & F socket outlet 2 in 1, 3 pin 5 Amps complete all as specified and directed.
S & F in replacement of socket out let combination multipurpose 3 Pin 5 amp, 240 volt and with 2 pin 5 amp out let also flush type including for existing points also (non shuttered) complete as specified and directed.
S & F in replacement of switch socket outlet combination 3 pin 15 Amp, 3 Pin 5 Amp out let also flush type (non shuttered) including for existing points complete all as specified and directed.
S&F in replacement ceiling rose surface backelite of size 65mm x 20 mm three terminal complete all as specified and directed.
S & F for lamp holder metal cased body of brass with back plate complete with 5 Watt LED lamp of make - C&S Cat Part No LTHPLEDLAMP5W/B22 or equivalent make in Crompton Greaves/Philips/Bajaj as approved by GE in writing.
S & F in replacement sheet metal enclosures for Vertical distribution board TPN, 4 way double door type including with MCCB 4 Pole, 100 Amps, 16 KA fixed type as incomer with 200 amp rated bus bar complete all as specified and directed.
S & F sheet metal enclosures for MCB distribution board SPN 8 way double door type with 200 amp rated bus bar and suitable for SPN Isolator as incomer complete all as specified and directed.
S & F in replacement MCB SP upto 6-30 Amp ,240 Volt complete all as specified and directed.
S & F in replacement Isolator SPN , 20 to 40 Amp , 240 Volt complete all as specified and directed.
M & L for replacement of regulator Electronic type 240 Volt single phase suitable for ceiling fan step type complete all as specified and directed.
M & L for earthing complete with galvanized steel earth plate electrode of size 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 Mtrs deep below ground level) with top edge of the plate not less than 1.50 Mtr below normal ground level connected to galvanized earth lead strip of size 25 mm x4 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No.5 connected to ear thing test point complete all as specified and directed including testing on completion including PCC type C-2 pit of (1:3:6) using 40 mm graded stone aggregate, RCC (1:2:4) Mix type B reinforced with 6mm dia MS bars @ 150 mm RCC cover slab 40 mm thick with two no’s fitting handle, GI pipe 20 mm dia light grade with funnel & wire mesh for watering and 40mm dia light grade GI pipe for earth strip of size 32 mm x 6 mm protection etc (Earthing result not more than 2 ohm and test result duly signed) complete all as specified and directed. ( Note : Earth strip having length 7.5 Mtr per earthing shall deemed to be included in the quoted unit rate.).
M & L for sub main wiring with two runs of single core 6 Sqmm (nominal area) PVC insulated and unsheathed multi stranded copper conductor cable LT 1100 grade FRLS cable concealed wiring drawn in and including 20 mm dia non metallic PVC conduit medium complete with all necessary fittings and accessories and run of PVC insulated and unsheathed single core cable with copper conductor of size 4 Sqmm as earth wire (green in colour ) run through PVC rigid conduit and connected to common earth dolly , including taking out the old sub main wiring all as specified. (Note. Two run of cable and one run of PVC conduit and one run of earth continuity wire shall be measured as one run complete all as specified) .
S & F LED light fitting 1 x 20 W, 220V, AC decoreative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
S & F in repair of sheet metal enclosures with 2 pins and earth plug single pole neutral link and one Nos MCB SP 20 Amp complete all as specified and directed.
SAXENA BANDHU
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .