Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.0 LAccepted-AOC | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹44.8 L+₹1.3 L (3.00%)Rejected-Finance | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹45.5 L+₹2.0 L (4.62%)Rejected-Finance | L3 | Rejected-Finance Being other than L1 | |
| 4 | L4₹45.8 L+₹2.3 L (5.35%)Rejected-Finance | L4 | Rejected-Finance Being other than L1 | |
| 5 | L5₹46.5 L+₹3.1 L (7.03%)Rejected-Finance | L5 | Rejected-Finance Being other than L1 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
26 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE 862 EWS
GE 862 EWS PIN 913862 c/o 56 APO
REPAIR TO DRAINS PATHWAYS BOUNDARY WALL OTHER MISC WORKS IN ZONE A AND ZONE B UNDER AOR OF AGE B/R DETT B OF GE 862 EWS
2020_MES_375007_2
GER-37/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE 862 EWS
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 862 EWS
₹90,000
Yes
21 Nov 2020
13 Oct 2020
28 Oct 2020
13 Oct 2020
26 Oct 2020
13 Oct 2020
60 days
Amount
Demolition of Brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stone-work and precast concrete articles complete all as specified and directed.
Brick work with sub class 'B' bricks, old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Brick work with sub class 'B' bricks,(except bricks, using old unserviceable brick after cleaning), old size, straight or curved on plan exc 6 m mean radius, built in cement mortar 1:6 complete all as specified and directed.
Stone walling of random rubble masonry, uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Stone walling of random rubble masonry (except stones, using old unserviceable stone after cleaning), uncoursed, well bonded, bedded and soilidly hearted, built in cement mortar (1:6), complete all as specified and directed.
Extra over stone walling of any type of stone for hammer dressing to face stones and dressing of face beds with maximum depression on face from straight edge held against the dressed surface n exc 20 mm and joints, as specified, of random rubble walling, uncoursed or brought upto courses complete all as specified and directed.
PCC type B-1 (1:2:4), (using 40 mm graded stone aggregates) in surface channels and drains complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using ex- tra cement, including forms, moulds, mi-tred/stopped ends etc complete all as specified and directed.
Demolition and breaking up drain pipes of 300mm bore (Salt glazed ware, AC or Reinforced concrete) set in cement mortar complete all as specified and directed.
450mm bore Reinforced concrete pipes, class NP3, laid and jointed complete with collars complete all as specified and directed.
PCC type B-1, 1:2:4 (using 20mm graded aggregate) as in coping, benching, hold fast, water troughs, bed block and the like including weathering, slightly rounded or chamfered angle and throating including necessary form work complete all as specified and directed
Demolition of unreinforced cement concrete in ground floors and paving n exc 15 cm thickness in ground floor complete all as specified and directed.
Precast RCC 1:2:4, type B1 as in landing, cover slab, chajjas etc and similar articles with plain faces set in CM 1:6 complete all as specified and directed.
Demolition of plain cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
100mm thick PCC 1:2:4, type B-1 (using 20mm graded stone aggregates) as in hardstanding, including spike rolling to surface complete all as specified and directed.
75mm thick PCC 1:5:10, type E-2 using 40mm graded stone aggregates as in sub base of floors and mass concrete complete all as specified and directed.
Pre-polished chequered cement concrete tiles of size 30 cm x 30cm x 25 mm thick, set & jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, laid over and including 20 mm thick cement screed bed in CM 1:4 complete all as specified and as directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 60mm thick, M-35 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Machine pressed precast concrete interlocking paver block of any shape and size approved by EIC, ISI marked (IS:15658-2006) 80mm thick, M-40 grade (Medium Traffic), in paths and hardstanding,with grey cement and pigment, laid tightly over & including 25mm thick dry sand cushion (compacted) and joints filled with dry sand, colour and pattern as approved by GE, complete all as specified and directed.
Excavation in trenches not exc. 1.5 m wide and n. exc. 1.5m in depth for foundation etc in soft/ loose soil and getting out complete all as specified and directed.
PCC 1:4:8, type D-2 (using 40mm graded stone aggregate) in foundation filling and mass concrete complete all as specified and directed.
Formwork to sides of pillars, posts, struts, piers, columns and stanchions for rough finished surface of concrete complete all as specified and directed.
Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Mild steel TMT bars 5mm to 10mm dia cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends as in stirrups, spacers and binders including binding with mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for as in louvers, jallied complete all as specified and directed.
25mm thick precast cement concrete louvers and jallies 1:2:4 type B-0 (using 12.5 mm graded stone aggregate ) set in CM 1:4 including all moulding but exc frames complete all specified and directed. Note- Pattern of jallies shall be as approved by GE.
Reinforced cement concrete type B-1 (1:2:4) (20mm graded stone aggregate) as in lintel bands/coping and the like including necessary form work complete all as specified and directed
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed.
Rendering 15 mm thick on concrete/brick surface on wall in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Rendering 20 mm thick on stone surface on wall in cement mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over and including a coat of alkali resistand primer complete all as specified and directed.
Preparation of old plastered surfaces of walls and applying two coats of cement base paint complete all as specified and directed.
Galvanised, 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and directed.
Concertina coil 1050 mm dia, 56 loops, 2.5mm core wire heavy galvanised (wire-275 GSM & strip-200 GSM), tensile strength of wire 1400-1500 N/Sqmm, weight 14.63 Kg/coil, stretchable length 12M inlcuding securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground complete all as specified and directed.
Taking out old unserviceable barbed wire fencing any type complete all as specified and directed.
Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm and removing surplus soil to a distance n exc 50m and making good surface in any type of soil complete all as specified and directed.
Angle iron posts or struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc. including horizontal running MS round bars, and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed. Note :- Size of angle shall be as per standard drgs.
PCC type C2 (1:3:6), using 40 mm graded stone aggregates as in sub base, foundation filling and mass concrete complete all as specified and directed.
Preparation of new or previously untreated steel surfaces of any description, over 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply only chain link MS galvanised fencing of size 100 x 100 x 3 mm as per sample approved by GE complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire complete all as specified and directed.
Mild steel screw bolts (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long, dia meter of shank 11 to 15 mm complete all as specified and directed.
Note:- The contract sum arrived after deduction of amount of Sch of credit as listed in tender Documents.
M/S Jyoti Parkash Tilak Raj Gupta
M/s Kay Aar Enterprises
M/S RAHUL GUPTA
M/s Mool Raj Romesh Chander
M/S MINTA & CO
m/s vishkarma construction
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .