| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.5 CrAccepted-AOC | ₹2.5 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹2.7 Cr+₹21.5 L (8.60%)Rejected-AOC NEAR R K HOTEL DISTRICT POONCH J K PIN 185101 | POONCH | POONCH | JAMMU AND KASHMIR | 185101 | ₹2.7 Cr+₹21.5 L (8.60%) | L2 | Rejected-AOC Other than lowest |
| 3 | L3₹3.1 Cr+₹62.4 L (25.0%)Rejected-AOC MAIN BAZAR SURANKOTE DISTT POONCH 185121 J K | SURANKOTE | POONCH | J K | 185121 | ₹3.1 Cr+₹62.4 L (25.0%) | L3 | Rejected-AOC Other than lowest |
Tender Value
₹2.8 Cr
EMD Value
₹3.5 L
Closing Date
3 Jun 2024, 6:00 pmClosed
CWE RAJOURI
HQ CWE RAJOURI
PROVN OF 08 X MAJ SINGLE LIVING OFFRS ACCN FOR POONCH UNDER GE 881EWS
2024_MES_648956_1
CWE/PNH-02/2024-25
Open Tender
Civil Works
Lump-sum
540 days
POONCH
AS PER NIT
9 documents required · 9 mandatory
₹2,000
Yes
GE 881 EWS
₹3.5 L
Yes
HQ CWE RAJOURI
3 Jul 2024
2 Apr 2024
10 Jun 2024
2 Apr 2024
3 Jun 2024
20 May 2024
27 Apr 2024
Amount
Schedule 'A' Part-I (Building Work) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Construction of single living Accn for officers (D/S) completes all as shown on drawings and as specified.
Construction of Garrages for Officers Vehicle completes all as shown on drawings and as specified.
Schedule 'A' Part-II (Internal Water supply works)
Total amount of Sch 'A' Part-II(Internal Water supply works) brought forward from srl page No-28
Schedule 'A' Part-III(Internal Electric Supply)
Total amount of Sch 'A' Part-III(Internal Electric Supply) brought forward from srl page No-30
Schedule 'A' Part-IV (Plumbing works)
Total amount of Sch 'A' Part-IV(Plumbing works) brought forward from srl page No-31
Schedule 'A'Part-V(Protective Work)
Total amount of Sch 'A' Part-V(Protective Work) brought forward from srl page No-32
Schedule 'A'Part-VI(Area drainage Works)
Total amount of Sch 'A' Part-VI(Area drainage Works) brought forward from srl page No-33
Schedule 'A'Part-VII(Sewage Disposal Works)
Total amount of Sch 'A' Part-VII(Sewage Disposal Works) brought forward from srl page No-35
Schedule 'A'Part-VIII(Road / Path/ hardstanding/Culvert Works)
Total amount of Sch 'A' Part-VIII(Road / Path/ hardstanding/Culvert Works) brought forward from srl page No-38
Schedule 'A'Part-IX( Hot Water Supply )
Total amount of Sch 'A' Part-IX(Hot Water Supply) brought forward from srl page No 39
Schedule 'A'Part-X(External water supply Works)
Total amount of Sch 'A' Part-X(External water supply Works) brought forward from srl page No-40
Schedule 'A'Part-XI(External External Electrification Works)
Total amount of Sch 'A' Part-XI(External External Electrification Works) brought forward from srl page No-42
Schedule 'A'Part-XII(Ventilation )
Total amount of Sch 'A' Part-XII(Ventilation) brought forward from srl page No43
Schedule 'A'Part-XIII(Misc Items of Works) Note : This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under Col. 5 siginifies this fact only.
Point wiring with two single core 2.5 Sqmm FRLS PVC insulated unsheathed copper conductor cable (nominal cross section area) and one single core 2.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including medium grade rigid non metallic PVC concealed conduit 25 mm with all fitting ISI marked in wall after cutting chases in wall including all requisite accessories such as PVC elbow, Tee, collars, bends etc controlled by one switch including modular MS sunken box of reqd size with modular cover plate with frame suitable for fixing of modular plug socket & modular MCB SP 16 Amp, 240 volt complete all as specified and directed. Note:- The rates are inclusive of cutting/ chassis in wal & suitable PCC works including making good to distrubed surfaces..
S&F angle valves, 15mm, chromium plated, cast copper alloy screwed down, high pressure rating, fancy type complete with all fittings all as specified and as directed.
Point wiring for one fan point with two single core 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor cable (nominal cross section area) and one single core 1.5 Sqmm FRLS PVC insulated unsheathed copper conductor cable as earth continuity to common earth and connecting to earth dolly running in and including medium grade 25 mm dia (ISI marked) rigid non metallic PVC concealed conduit in wall after cutting chases in wall including all requisite accessories such as PVC elbow, Tee, collars, bends etc and controlled by one way switch 6 Amp including modular MS sunken box of reqd size with suitable modular cover plate with frame complete all as specified and directed.
Material and labour for point wiring complete with PVC insulated, FRLS type, unsheathed, multistranded, flexible, copper conductor cable 1.5 sqmm,1100 volts grade, 2 Single core ,drawn through and including concealed PVC conduit of suitable size 25 mm with all fitting (ISI marked) or above as required at site with all accessories such as Tee, corner, connector etc.on walls, roofs and ceilings etc. including concealed modular sheet terminal box factory made of suitable size with modular cover plate with frame for mounting modular switches, sockets, fan regulators, etc and including 1.5 Sqmm PVC insulated, multistranded, unsheathed (Green colour),FRLS type single core, copper conductor cable as earth continuity conductor and connecting to common earth dolly complete all as specified and directed for one light/ Exhaust fan point controlled by one switch all as specified and directed.
All as per item No 13.05 above, but for One 3 pin 6 amps socket out let point controlled by one 6 amps switch on independent board.
All as per item No 13.05 above, but for One 3 pin 6 amps socket point controlled by one 6 amps switch on same board.
All as per item No13.05 above, but for one light point controlled by two 2 way 6 amps switch
All as per item No 13.05 above, but for one bell point controlled by one bell push.
All as per item No.13.05 above, but with 2.5 sqmm for One 3 pin 16 amps socket outlet point controlled by one 16 amps switch on on independent board.
All as per item No.13.05 above, but with 4 sqmm for One AC point controlled by one modular MCB SP 20 Amps on independent board.
Supply and fixing LED tube light fitting 1x 20W, 220V AC with driver, connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as required at site or directed.
Supply and fixing LED tube light fitting 1x 10W, 220V, with driver, connecting up with flexible copper conductor cable of suitable size from ceiling rose complete all as required at site or directed.
Supply and fixing LED street light fitting 25W, 220V, AC fixed on building including GI bracket made of suitable size & length connecting up with flexible copper conductor cable of suitable size all as required at site or directed.
S&F for factory made sheet metal enclosure, double door, 415 volts, AC, TPN vertical distribution board 4 way suitable for mounting MCCB as incomer of rating upto 125 Amps and MCB SP as outgoing and complete with suitable rated busbar, neutral bar, earth bar, connecting cable links with and including top bottom removable gland plate with IP 43 protection complete all as specified and directed. (Note:- MCCB & MCBs will be measured separately.)
Supply and fix MCCB TP ,415 volts with thermal magnetic protection unit, 100 Amps, 25 KA, complete all as specified and directed.
S & F modular RJ11 telephone socket 1 module,complete all as specified and directed.
S & F modular television socket 1 module, complete all as specified and directed.
S&F sheet metal enclosure MCB distribution board Single pole & neutral 230 volts 6 way with IP-43 protection double door fixed flush in wall complete all as specified and directed. (Note-MCBs will be measured separately.)
Supply and fix MCB SP 6 to 32 Amps,10 KA, "C" series, 240 volts complete all as specified and directed.
Supply and fix MCB SP 63 Amps,10 KA, "C" series, 240 volts complete all as specified and directed
S & F modular plug socket 20 Amps alongwith 20 Amp MCB SP 240 Volts all as specified and directed
Supply & fix MCB SPN 40-63 Amps 10 KA, "C" series, 240 volts complete all as specified and directed.
Supply & fix MCB SPN 06 Amps 10 KA, "C" series, 240 volts complete all as specified and directed.
S & F modular plug socket 16 Amps alongwith modular 16 Amp MCB SP 240 Volts all as specified and directed.
Condtruction of Septic tank for 25 User ( Brick Construction) Complete all as shown on drawing and all as specified.
Construction of Sokage well (brick work) of size 1.8 mtr dia X 3.0 mtr deep ( internal dimension)Complete all as shown on drawing and all as specified.
S & F Ceiling Fan BLDC suitable for working on fan regulator complete with three blades, down rod and accessories, 230 volts, 1200 mm sweep complete all as specified and directed.
M/S RAJINDER KUMAR
M/S KIRAN CONSTRUCTIONS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .