Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.7 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹29.2 L+₹53,466.94 (1.87%)Rejected-Finance | L2 | Rejected-Finance Other than lowest | |
| 3 | L3₹30.3 L+₹1.6 L (5.75%)Rejected-Finance | L3 | Rejected-Finance Other than lowest | |
| 4 | L4₹30.8 L+₹2.1 L (7.41%)Rejected-Finance | L4 | Rejected-Finance Other than lowest | |
| 5 | L5₹33.3 L+₹4.7 L (16.4%)Rejected-Finance 32 H I G AWAS VIKAS COLONY SECTOR 3 BODLA AGRA UP 282007 | AGRA | AGRA | UP | 282007 | L5 | Rejected-Finance Other than lowest |
Tender Value
₹38.9 L
EMD Value
₹77,800
Closing Date
24 Sept 2022, 6:00 pmClosed
Shri Arun Kumar, Offg GE
Ge West Agra
SPECIAL REP TO BLDG NO 07 (ANCILLARY GARAGE) OF 2 (I) PARA, BLDG NO 63 and64 (FOL DUMP) OF 17 PARA, PROVN OF HARD STANDING OF 17 PARA FD REGT, PROVN OF PLATFORM FOR MORTAL REMAINS OUTSIDE MORTUARY AT MH AND PROVN OF 01X SHED FOR DRINKING WATER 1000
2022_MES_547885_1
8012/917/E8
Open Tender
Civil Works
Item Rate
180 days
Ge West Agra
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
Ge West Agra
₹77,800
16 Dec 2022
26 Aug 2022
27 Sept 2022
26 Aug 2022
24 Sept 2022
9 Sept 2022
Amount
Surface excavation n. exc 30 cm deep & averaging 15 cm deep & getting out in soft loose soil including cutting to required gradient and camber as for formation of roads/berms complete all as specified & as directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan etc and getting out in loose/soft soil complete all as specified and directed.
M&L for PCC (1:4:8) type D-2 (using 40 mm graded brick aggregate) as in in foundations, sunken floor, filling and mass concrete complete all as specified and directed.
M&L brickwork with sub-class `B' brick straight or curved on plan to any radius in half brick thick walls built in CM 1:4 complete all as specified & directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for 12mm thick rendering in CM 1:4 on fair faces of brick work or concrete surfaces finished of wall finished surface even and smooth without using extra cement complete all as specified & directed.
M&L for ceramic non skid coloured tiles, joint free, 7mm to 8 mm thick (square /rectangular),(Ist quality/Premium quality), area of each tiles exceeding 0.06 but n exc 0.11 Sqm in floors etc, laid over and including 15 mm thick screed bed or bedding layer in cement mortar 1:6, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles, complete all as specified and directed
M&L for (350mm x 250mm x 7mm / 450mm x 350mm x 7mm thick ) coloured glazed ceramic tiles in vertical surface set and jointed in neat cement slurry and pointed with white or coloured cement mixed with pigments over 15mm thick rendering in CM 1:4 complete all as specified and directed.
M&L 75 mm thick PCC 1:4:8, type D-2 (using 40mm graded crushed stone aggregate) as in sub base, finished even and fair complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection ( 50 mm thick ) finished even and fair without using extra cement, including making joints 12mm wide to the fool depth of PCC at 3m (max) and every change of direction and filling the same with and inlcuding bitumen and sand 1:3 by weight complete all as specified.
M&L for 15mm thick rendering in CM 1:4 with water proofing compound @ 2% by wt of cement or as per manufacturer's instructions on fair faces of brick work or concrete surfaces finished even and smooth without using extra cement complete all as specified & directed. Note :- WPC shall be measured & paid separately under respective item.
Supply only integral water proofing compound complete all as specified and directed.
S&F 100mm cast iron soil waste and vent pipe in any length with or without ears laid in floor/ tranches, complete all as specified and directed
S&F 75 mm dia of outlet CI nahani trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
S&F 100 mm dia of outlet CI floor trap, with grating including jointing to waste pipe fixed in cement concrete (1:2:4), type B1(using 20 mm graded stone aggregate) complete all as specified and directed.
S&F 20 mm bore steel water tubing, medium grade, galvanized including fittings and fixed to walls, ceilings, floors or laid in floors complete all as specified and directed.
S&F rotational moulded polyethene water storage tank (cylindrical / vertical with closed top) 500 ltr capacity, ISI marked including PVC lid, 20 mm dia ball valve high pressure of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe (minimum weight 210 gms) hoisted and fixed in position with threaded, nipple of suitable size complete all as specified & as directed.
M&L for applying two coats of cement base paint on wall over a coat of primer including preparation of new plastered or un-plastered surfaces, complete all as specified and directed.
M&L for 60 mm thick precast PCC interlocking coloured paver rubber moulded block factory made of grade M 35 single layer monolithic high density manufactured by electro vibro hydraulically operated block making matching conforming to IS -15658- 2006 laid and jointed over sand cushion layer complete all as specified and directed. Note : Sand cushion shall be measured & paid separately
M&L for hard core of gauge n.exc 63mm, deposited, spread and leveled in layers n exc.15cm thick watered and rammed to a true surface complete all as specified & as directed.
M&L for cutting into existing manholes for connecting internal dia of pipe 150mm in new drain, making good to pipe and rendering cutting out existing benching for channel (1/2 or 3/4section) in cement concrete 1 : 2 : 4 type B-1 by repairing benching as required complete all as specified and directed.
S&F Pre- painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour as approved, having tensile strength of 550 Mpa as in roof /cladding , fixed to wall with self tapping screws complete all as specified & directed.
S&F roof trusses (framed), trussed, purlins, prop, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. confirming Fe-410-W(Gde-E-250) quality-B and painted one shop coat of zinc chromate primer paint (including preparation of surface) at contractors workshop before fabrication complete all as specified & as directed.
S&F for rolled section as joist, channel, angle or tee section, fixed independently, without connection plates, etc (cut to ordinary lengths i.e. within 20 mm of the length indicated) etc conforming to Fe- 410w complete all as specified & as directed.
S&F for rolled section as in main and cross beams, purlins, rafters where connected to common rafter and running rails etc conforming to Fe- 410-w complete all as specified & as directed.
M&L for preparation of new or previously untreated steel surfaces over 10 cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified & as directed.
Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in Soft/ Loose soil and removing surplus soil to a distance not exceeding 50 M and making good surface, complete all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and paving n.exc 15cm thickness (below or above ground level) complete all as specified and directed.
M&L for 100mm thickness PCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in hard standing incl necessary joint filling with bitumen complete all as specified
Taking down cement or cement lime plaster, any description on brick or stone walls, etc., including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces of wall in cement mortar 1:6 , finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for preparation of new plastered or unplastered surfaces of walls of any description by and applying two coats of oil emulsion distemper white or tinted over a coat of wall putty complete all as specified and directed.
M&L for preparation of old plastered or unplastered wall surfaces by complete removal of existing treatment and applying two coats of distemper oil emulsion (washable) over 1mm thick Birla putty complete all as specified and directed.
M&L for preparation of newly plastered or un plastered surfaces of walls and applying three coat of white wash on wall surfaces complete all as specified and directed.
M&L for preparation of old plastered or un plastered surfaces of walls including brooming down or steel wire brushing, scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc and applying one coat of white wash on ceiling on old decorated surfaces complete all as specified and directed.
Taking out / dismantling of mud or existing roof treatment of, any thickness, including plastering and leaping and tiling/ padding of any description including disposal of removed/demolished soil/material exc 1.5 km but n.exc 5 km, depositing out side the MD land or where directed, complete all as specified and directed specified and directed.
M & L for cutting out cracks to V-section in existing roofs or terracing, cleaning out, wetting grooves and supply and filling cement mortar 1:3 complete all as specified and directed
M&L for PCC 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in padding over roofs, roof kerbs etc complete all as specified and directed.
M & L for water proofing treatment of roof slab all as follows: - (a) Preparation of roof surfaces by brushing, cleaning and applying 15mm thick plaster in CM 1:4 mixed with water proofing compound as per manufacturer's instruction. (b) Applying one priming coat with bitumen primer @ 0.5 ltr/Sqm (c) Applying a hot blown bitumen grade 85/25 @ 1.2 Kg/sqm (d) Laying APP modified water proofing membrane weight not less than 3 Kg/Sqm applied bitumen coat. (e) Applying a tack coat of hot bitumen grade 85/25 @ 1.2 Kg/Sqm and spreading sand (confirming to Zone II) in dry condition over the bitumen @1.00 Kg/Sqm Note : WPC shall be measured and paid separately under respective item
M&L brick tiles 40 mm thick laid over 15 mm thick screed bed in CM 1:3 and jointed in CM 1:3 with linced oil @ 5% by weight of cement complete all as specified and directed.
M&L for applying one coat of epoxy resin (FAIR BOND EP) on old concrete surfaces of ceiling and beams, chhajja, stair case etc. @ 0.30 Kg/Sqm including preparation of surfaces as per manufacturer's instructions complete and applying 25mm thick (average thickness) of cement and sand (Fine grit) in ratio 1:3 mixed with chloride free spray concrete plasticizer (spray crete) as per manufacture instruction with guiniting machine of presser capacity not less than 5 Kg per Sqcm and finished the surfaces even and smooth complete all as specified and directed.
M&L for rendering 10 mm thick on fair faces of brick work or concrete surfaces of ceiling in cement mortar 1:4 , finished the surface even and smooth without using extra cement complete all as specified and directed
M&L for preparation of newly plastered or un plastered surfaces of ceiling and applying three coat of white wash on ceiling surfaces complete all as specified and directed.
Taking down of old precast interlocking paver block of any size and shape, any description and in any position complete all as specified and directed.
M&L for 80 mm thick precast PCC interlocking coloured paver rubber moulded block factory made of grade M 40 single layer monolithic high density manufactured by electro vibro hydraulically operated block making matching conforming to IS -15658- 2006 laid and jointed over sand cushion layer complete all as specified and directed. Note : Sand cushion shall be measured & paid separately
Demolition of brick work or stone/ boulder masonry, built in cement mortar including all quoins, pillars etc. complete all as specified and directed
M&L for brick work using sub-class `B' fly ash bricks, old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, complete all as specified and directed.
M&L for mild steel framed work as in doors or gates of angle or other section with guest plates rails, braces rail etc, confirming to Gde Fe-410-0 or Fe-310-0 (exclusive of steel sheeting or other covering), hanging, fastening and fixing complete including shop coat of red oxide complete all as specified and directed.
M&L black mild steel (plain) 1.25 mm thick sheeting in stepped flashings (measured as the minimum rectangle from which the pieces can be cut) and if welded or shouldered joint complete all as specified & as directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
Dismantling wire mesh any type and description complete all as specified and directed.
M&L for cement concrete 1:3:6, type C-2 (Using 40 mm graded stone aggregate) in foundations, filling and mass concrete complete all as specified & as directed.
S&F hand rails, half round or other stock section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embedding in concrete and screwing etc. wind ties for roof including securing bolts posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete all as specified and directed
Supply only MS Galvanized chain link fencing any size and type complete all as specified and directed
Fixing only chain link fencing including line wires, any mesh, size and type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed
S&F mild steel round bars confirming to Fe 290 Gde E-165 10mm dia as line rows for securing chain link fencing complete all as specified and directed
S&F 12mm dia mild steel screw bolts (machine made) with hexagonal or square head at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, not exceeding 5 Cm long complete all as specified & directed.
Dismantling of Asbestos cement (corrugated, semi corrugated, etc) sheets in roof coverings complete all as specified & as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified & as directed.
M&L for 25mm thick cement concrete type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) in sub floors, sub-bases etc for receiving the toping layer finish the surface even & rough, complete all as specified and directed.
M&L for 20 to 25mm thick machine cut kota stone slab flooring over 20 mm thick cement screed bed in CM 1:6, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed
M&L for 18 to 20mm thick machine cut kota stone as in vertical surfaces like skirting, steps etc, over 15 mm thick cement screed bed in CM 1:4, laid and jointed with grey cement slurry mixed with pigment to match the shade of the stone slab including cutting, grinding, rubbing and mirror polishing complete all as specified and directed
M&L for brick work with sub-class `B' bricks, old size, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6, complete all as specified and directed.
Taking down chowkhats or frames with shutters(without taking off shutter from the frames) area not exc 1.5 Sqm each complete all as specified and directed.
S & F steel windows with side hung shutters including box type hinges with Z section steel handle and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed
S & F steel windows with side hung shutters including box type hinges with Z section steel handle and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed
S & F Mild steel work in framed work such as grills, gratings etc with ends of bars shouldered and/or riveted, or forged in to spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings, frame work of water tanks, and similar work conforming to Fe-290 Gde-165 complete all as specified and directed.
M & L for Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types in slab flooring or in skirting laid over brushing neat cement slurry with 3.0kg of cement per sq. metre and 20mm thick cement screed bed or bedding layer in CM (1:6), complete all as specified and directed.
Taking down chowkhats or frames with shutters(without taking off shutter from the frames) area exc 1.5 Sqm not exc 4 Sqm each complete all as specified and directed.
M & L for cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate as in bed block for fixing of hold fast complete all as specified and directed.
S&F 35mm thick 2nd class hardwood plain framed panelled shutters (any number of panes ) with panels of timber flat on both side (feather edged ) or of veneered particle board medium density wood particle board with commercial face veneers supplied and fitted to chowkats complete all as specified and directed
M & L 35mm thick glazed and Skelton shutters, open rebated and prepared to receive glass, gauge, etc (without sash bars), edges of framing plain, chamfered of rounded fitted with cut and mitered beads for securing glass, etc sizes of members of shutters as specified in SSR Part-I, section 8, clause 8.24 (a) supplied and fitted to chowkhats complete all as specified and directed.
S&F 125 mm long medium weight, cold rolled mild steel Butt hinges complete all as specified and directed.
S & F 250 mm long Aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy complete all as specified and directed.
S & F 200 mm long Aluminium, anodised, barrel tower bolts of extruded section complete all as specified and directed
S & F 150 mm long aluminium handles, cast type, anodised complete all as specified and directed.
S&F floor door stopper 150 mm long of aluminium alloy body and tongue, anodised, with hard drawn steel spring, fixed in floor complete all as specified & as directed.
S&F 4.0 mm thick ordinary quality sheet glass and glazing with oil putty in square not exc 0.5 Sqm in each pane complete as specified and directed.
S & F in repair mild steel 300mm, ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed..
M & L for preparation of new surface of wood over 10 cm width or girth and applying two coats synthetic enamel paint over a coat of pink primer complete all as specified and directed.
M&L for preparation of newly plastered surface of wall and applying two coats of weather proof paint over a coat of primer/ wall care putty in different tint complete all as specified and directed.
M&L for applying one coat of cement base paint on wall including preparation of old plastered or un-plastered surfaces, complete all as specified and directed.
M&L PCC 1:3:6, type C-1 (using 20 mm graded crushed stone aggregate) as in plinth protection ( 75 mm thick ) finished even and fair without using extra cement all as specified.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, lamp holders, light fitting etc removing materials to store for keeping in safe custody for taking credit or reuse serviceable fittings/fixtures and making good the disturbed surfaces of wall/floors all as specified & as directed.
M&L for point wiring concealed type with 1.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 1.5sqmm PVC insulated unsheathed stranded copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed for (i) one light/ fan/street/bell point controlled by 1 one way switch 5/6 Amps
All as per item No 86 above but one socket outlet 5/6 Amps controlled by one switch on independent board but not below the switch board
All as per item No 86 above but one socket outlet 5/6 Amps controlled by one switch on the same board with other switches
Supply and fix switch piano, flush type, single pole, 5/6 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.38058 or equivalent as approved by GE.
Supply and fix socket outlet, 5/6 Amps, flush type, 5 pin 230 volts complete all as specified and directed. Make: Anchor Cat No.38320 or equivalent as approved by GE.
S&F for ceiling rose surface bakelite 62.5 x 25 mm size 3 terminals complete all as specified and directed. Make -Anchor CAT Part No-39072 or equivalent as approved by GE.
Supply and fix lamp holder insulated body with back plate for batten fitting complete all as specified and directed. Make: Anchor Cat No. 39797/ 39800 or equivalent as approved by GE.
Supply and fix electronic stepping up type ceiling fan regulator suitable to operate at 230 volts 50 Hz , AC ISI marked complete all as specified & directed.
Supply and fix LED Bulb 15 watt suitable for lamp holder complete all as specified and directed. Make -Philips/Havells/Surya
Taking down distribution boards any size any type including MCB TPN/SPN/SP etc and making good the disturbed surfaces complete all as specified and directed.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 8 way with 200 amps rated bus bar 240 volts complete all as specified and directed. Make:- Hevells or equivalent model of make Siemens/ Schneider as approved by GE.
Supply & fix MCB SPN, 6 to 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand CAT No. 4086 178 or equivalent model of make ABB/ L&T/ Schneider as approved by GE.
Supply & fix MCB SP, 6 to 32 Amps, 'C' series, 240 volts, 50Hz, 10kA complete all as specified & directed. Make:- Legrand CAT No. 4085 87 to 4085 96 or equivalent model of make Siemens/ Schneider as approved by GE.
M&L for electrically disconnecting and taking down existing ceiling/Exhaust fans from any height or in any position from existing bldg and keeping in safe custody for reuse at site after necessary repair/ servicing & painting with one coat of synthetic enable paint and writing of MES/identification No. of fans and re hanging/ re-fixing in original position but including replacement of three core flexible copper conductor cable from ceiling rose to fan connector block of size 0.75 Sqmm and hanging fan clamps, nuts, bolts and rubber reel bush etc & testing for proper functioning complete all as directed.
Supply laying and testing cable XLPE insulated screened PVC bedded galvanized steel strip or wire armoured electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core complete all as specified and directed.
Excavating in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or not exceeding 10 Sqm on plan etc and getting out in loose/soft soil complete all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25cm thick complete all as specified and directed.
Removing surplus soil to a distance n.exc 50 M and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply & laying reinforced precast concrete cable cover, class LV, type-I, flat, size 250 mm x 150 mm x 40 mm for cable protection complete all as specified & directed.
M&L for sand cushioning dry, fine for cable cushioning 8 cm below the cable and 15 cm above duly punned down to 18 cm over all complete all as specified & directed.
Material and labour for 40mm galvanised steel tubing light grade for protection of cable/earth continuity conductor fixed to poles/walls/roof or laid in floors, road crossing/in ducts fixed with clamps, bolts, nuts and washers etc complete all as specified and directed .
Supply & fix surface/wall mounting LED batten 20 watt luminaries having extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffuser and integrated electronic driver with mounting accessories complete with lamp holders fixed to wall/ ceiling with fixing accessories and connecting up with & including twin twisted copper flexible wire of size 0.75 sqmm from ceiling rose to fittings complete all as specified & directed. Make:- Havells cat part No-ENDURALINEARNEOBS20WLED865SPCWH or equivalent Model of Philips/Bajaj/CG as approved by GE.
S & F mild steel wire cloth , 0.40 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with stainless steel wire staples complete all as spd by engr-in-charge.
Supply only integral water proofing compound complete all as specified and directed.
M&L for preparation of wall plastered or unplastered old surfaces and applying two coats of oil bound distemper over a coat of1mm thick wall putty complete all as specified and directed..
M&L for preparation of new plastered or unplastered surfaces of walls of any description by and applying two coats of oil emulsion distemper white or tinted over a coat of wall putty using roller device complete all as specified and directed.
M&L for point wiring concealed type with 2.50sqmm PVC insulated, unsheathed, single core, multistranded copper conductor FRLS cable 1100 volts grade including 2.5.5sqmm PVC insulated unsheathed stranded copper conductor FRLS cable as earth continuity conductor drawn through in and including rigid PVC conduit not less than 20mm dia with its accessories, sunken type pressed steel terminal box made of 1.2mm thick MS sheet/ anodised steel box painted with one coat of red oxide primer including 3.0mm thick ISI marked laminated sheet cover for fixing switches/ socket/regulators etc including all fixing accessories and cutting chases as per standard engineering practice & making good the disturbed surfaces as per existing complete all as specified & directed for :- (i) 15/16 Amps controlled by one switch on independent board and wiring with 2.5sqmm cable.
Supply and fix switch piano, flush type, single pole, 15/16 Amps one way, 230 volts complete all as specified and directed. Make: Anchor Cat No.39991 or equivalent as approved by GE.
Supply and fix socket outlet, multi-purpose, 3 pin 5/6 Amps and 15/16 Amps, volts complete all as specified and directed. Make: Anchor Cat No.39994 or equivalent as approved by GE.
Supply and fix MCB DB sheet metal enclosure factory fabricated double door SPN 4 way with 100 amps rated bus bar 240 volts complete all as specified and directed. Make:- Hevells or equivalent model of make Siemens/ Schneider as approved by GE.
Supply, installation, commissioning of Water cooler fully stainless steel, electric driven single phase having approx storage and nominal cooling capacity of 60 Ltrs per hour and storage capacity of 120 Ltrs with 2 Nos cold water outlet & wastage water tray with drain pipe, 3 core connection cord of size 2.5 sqmm copper conductor of length minimum 2.0 Mtrs with molded 3 pin plug top complete all as specified and directed. Make :- Blue Star/ Godrej/ Voltas/ Usha
Supply and lay pipe galvanized, “Medium class”, including fittings 20 mm (3/4”) dia with all fittings complete all as specified and as directed at site. Make :- TATA, Jindal, Prakash Surya.
Sree Ram Enterprises
M/S A GUPTA AND ASSOCIATES
M/S RAJESH ENTERPRISES
m/s shanti consruction co
Asha Construction
saroj constructions
CREATIVE CONSTRUCTION
Sethi Brothers
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .