Loading…
Loading…
Tender Value
₹38.5 L
EMD Value
₹77,000
Closing Date
27 Jul 2026, 6:00 pm
GE AF THANE
Office of Military Engineer Services ,Garrison Engineer (AF) Thane, Kolshet Road, Sandoz Baugh Post, Thane 400607
REPAIR MAINTENANCE OF SECURITY LIGHT, HIGH MAST DISTRIBUTION SYSTEM, CEILING FAN, EXHAUST FAN, WALL MOUNTED FAN, METER, INTERNAL WIRING FITTING AND OTHER ALLIED WORKS AT SITE P AND SITE R AT AF STATION THANE UNDER GE (AF)THANE
2026_MES_776891_1
GE (AF) T-06 OF 2026-27 (8613)
Open Tender
Electrical and Maintenance Works
180 days
THANE
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
GE AF THANE
₹77,000
Yes
7 Jul 2026
7 Jul 2026
3 Aug 2026
7 Jul 2026
27 Jul 2026
21 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Supply and providing Eletrician with helper for repair the unserviceale street light/ aviation light including taking down High Mast Light and taking up High Mast machanically/ Post Lamp fittings/ Garden Light, Gate light and reflixing the same in existing postion including testing after repair complete all as specified and directed by Engineer-in-Charge,
Note: (a) Necessary spare, fitting, excavation other related work will be measured in respective items.
(b) Necessary tools, ladder, safty equipment for electrifican and helper will be arrange by the contractor in his own coast | 10 | Each Job | - | - |
| 2 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 30 watt, complete all as specified and directed by Engineer-in-Charge. | 50 | Each | - | - |
| 3 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 45/60 watt, complete all as specified and directed by Engineer-in-Charge. | 47 | Each | - | - |
| 4 | Supply only Electronic Driver with input Voltage 220 to 240 Volt and output Voltage suitable for LED light fitting of capacity 120 watt, complete all as specified and directed by Engineer-in-Charge. | 50 | Each | - | - |
| 5 | Supply only Surge Protection Device of capacity 10KV Single Phase 50Hz, complete all as specified and directed by Engineer-in-Charge. | 30 | Each | - | - |
| 6 | S&F Multi LED Street Light fitting of capacity 30 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and directed by Engineer-in-Charge.. | 40 | Each | - | - |
| 7 | S&F Multi LED Street Light fitting of capacity 45 Watt IP 65, having Die-cast Aluminium Housing, weather proof with Accessories and connecting up with and including PVC insulated Copper Conductor cable 1.5 Sqmm, single core including Taking down unserviceable Street light fitting from the Electric pole, complete all as specified and directed by Engineer-in-Charge. | 24 | Each | - | - |
| 8 | M&L Inegaral Decorative LED 8 Watt Bollard Energy saving, Environmental friendly aesthetically designed with opal acrlylic with IP-65 proctection, providing electric connection with suitable PVC copper flexible conductor, providing PCC 1:3:6 (20mm graded aggregate) work of size 300x300x450mm including necessary formwork and earth work, complete all as specified and directed by Engineer-in-Charge. Cat part No. LHEVBDP7IN6K008 | 8 | Each | - | - |
| 9 | Supply & fixing in replacement Integral LED aviation light 30 watt comprising of aluminium housing with polycarbonate enclosure with IP-65 protection complete all as specified and directed by Engineer-in-Charge. | 2 | Each | - | - |
| 10 | Supply, fixing and testing LED Flood light fitting of 120 Watt in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 - 270 V, AC, frequency 50 - 60 Hz ,P.F should be more than 0.9 with Total Harmonic Distoration THD(I) less than 10% ,cool white colour and lamp starting time should not be more than 10 second. Fitting should be provided with 10 KV surge protection.Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection .LED light fitting should be suitable for ambient temperature from -10 degreeCentrigrade to 50 degree Centrigrade and humidity level 10% to 90 % RH. Covers should be polycarbonate/toughened glass to ensure minimum IP 65 degree protection.Cover should not degrade due to heating and ageing.The efficiency of LED luminaries system shall be more than 85 lumens per watt and must be certified by the LM-79 test report complete all as specified and directed by Engineer-in-Charge. | 10 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.29 MB
TD8613.pdf
Tender Documents • 2.05 MB
BOQ_870026.xls
BOQ • 0.67 MB
Download all tender documents and submit your bid