Loading…
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹62,900 ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | L1 | - | |
| 2 | L2₹97,100+₹34,200 (54.4%) ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | L2 | - | |
| 3 | L3₹1.2 L+₹52,400 (83.3%)Financial bid opened ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | L3 | Financial bid opened | |
| 4 | L4₹1.2 L+₹61,100 (97.1%)Financial bid opened ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | L4 | Financial bid opened | |
| 5 | L5₹1.2 L+₹61,600 (97.9%) ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.) | L5 | - |
| Sl No | Description | Qty | Unit | M/s Mirchandani & Sons (9811131961) L3 | M/s S K Enterprises L2 | SUPER ELECTRICAL CO. L6 | M/S NETROMICS ENGINEERING SOLUTIONS PRIVATE LIMITED, GURUGRAM L4 | Garv Jaswaya L5 | SONU L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1 | Providing and making 11 kV grade heat-shrinkable type end termination for 1C x 185 sq.mm XLPE HT cable, complete with all accessories including suitable cable lug, gland, stress-control and insulating components, screen/armour earthing arrangement, cable preparation, crimping, sealing and connection to HT equipment, including testing of the complete cable by calibrated HV/High-Pot testing machine after termination, insulation resistance, continuity and phase identification tests, necessary safety arrangements, discharge and earthing after testing, recording and submission of test results, complete as per CPWD specifications, relevant IS standards, manufacturer's instructions and as directed by the Engineer-in-Charge.” | 6 | Job | 9,000 ₹54,000 | 5,000 ₹30,000 | 15,000 ₹90,000 | 9,000 ₹54,000 | 8,500 ₹51,000 | 3,000 ₹18,000 Lowest |
| 2 | Supply of 11 kV grade, 1 core × 185 sq. mm, XLPE insulated, screened, PVC sheathed, armoured HT power cable with stranded aluminium conductor, suitable for 11 kV system voltage, conforming to IS 7098 (Part-II) and relevant CPWD specifications, complete in all respects as required and as directed by the Engineer-in-Charge | 6 | Mtr | 2,800 ₹16,800 | 2,100 ₹12,600 Lowest | 4,435 ₹26,610 | 8,000 ₹48,000 | 8,000 ₹48,000 | 3,400 ₹20,400 |
| 3 | Testing, checking and servicing of 750 kVA, 11 kV oil-filled HT transformer, including High Pot testing, checking, cleaning and decarbonizing of contacts, tightening of all electrical connections/joints, bushing connections, cable termination connections and associated nuts & bolts, complete in all respects as required. | 1 | No | 17,500 ₹17,500 | 40,000 ₹40,000 | 25,000 ₹25,000 | 13,000 ₹13,000 | 9,500 ₹9,500 | 8,500 ₹8,500 Lowest |
| 4 | Checking, testing and comprehensive cleaning of 11 kV HT FS-6 panel board, including opening and checking incoming/outgoing cable terminations, CT chambers, bus-bar and switchgear contacts; removal of dust/moisture; cleaning and decarbonizing of bushings and contacts; tightening of all electrical connections, bus-bar joints and cable terminations; replacement of defective nuts, bolts and hardware; application of insulated epoxy paint; taping and application of insulating compound at cable terminations; and testing by suitable HV/High-Pot test equipment, complete in all respects as required. | 1 | No | 28,000 ₹28,000 | 15,000 ₹15,000 | 13,500 ₹13,500 | 10,000 ₹10,000 Lowest | 21,000 ₹21,000 | 16,100 ₹16,100 |
| 5 | Credit/buyback for dismantled Material i/c dismenting of dismentled materials. (All materials assumed as assorted) | 1 | Job | 1,000 ₹-1,000 | 500 ₹-500 | 1,500 ₹-1,500 | 1,000 ₹-1,000 | 5,000 ₹-5,000 | 100 ₹-100 Lowest |
Tender Value
Refer Docs
Closing Date
12 Oct 2026, 3:00 pmClosed
AE-E-4
Assistant Engineer (E) SD-4 NCERT Campus
ARMO of sub station and AC Plant at IGNOU Campus Maidan Garhi New Delhi. (SH:- Repairing and replacement of worn out part in 750 kVA oil type Transformer at IGNOU Campus.)
171604
NIQ AEE-4/DED-61/2026-27/184
OPEN
Electrical Works
NCB
3 days
South Delhi, Delhi
4 documents required · 4 mandatory
Not Applicable
12 Oct 2026
8 Oct 2026
12 Oct 2026
12 Oct 2026
12 Oct 2026
stage.html
html • 0.07 MB
boq_comp_chart.xls
xls
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
NIQ184.pdf
document • 1.17 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .