Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance 204 4 KATHIRKUPPAM VILLAGE MUGUNDARAYAPURAM POST RANIPET WALAJA TALUK VELLORE 632 405 | VELLORE | VELLORE | TAMIL NADU | 632405 | Admitted-Finance |
Tender Value
₹21.6 L
EMD Value
₹22,100
Closing Date
4 May 2023, 3:00 pmClosed
Block Development Officer,
Block Development Officer, Walajah Block 631102
Construction of 60000 ltr OHT in at Agravaram H/o Mukundharayapuram Panchayat Walajah Block Ranipet District.
2023_RDTN_305678_1
B2/1386/2023/10.04.2023
Open Tender
Civil Works
Works
90 days
Walajah Block
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹22,100
18 May 2023
24 Apr 2023
4 May 2023
24 Apr 2023
4 May 2023
24 Apr 2023
Amount
Walajah Block
Construction of 60000 lit's Capacity OHT (12.00m Staging Height) at Agaravaram H/O Mukundarayapuram Panchayat
Earth work Excavation for Foundation in all soils and Sub Soil as per SS20B for foundation etc. complete.SS 20B
Second depth of 0.25m
Supplying and filling foundaton and basement with filling sand n layaedrts not more the 15cm thick well remed waterede and compacted complete complying with standard specifcatiion
Cement concrete 1:4:8 mix using 40mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete for 10 cum.
Cement concrete 1:1.5:3 mix using 20mm ISS metal including cost and conveyance of all materials to site and all labour charges for mixing,laying and curing etc complete for 10 cum.
Items 1.50 m to 4.50m below GL
Items 0 m to 1.50m below GL
Items 0.0 to 4.50m Above GL
Items Above 4.51m to 7.32 m
Items Above GL 7.33m to 10.98m
Items 10.98 m to 14.64 m above GL
14.64 m 18.30m above GL
Supplying and erecting centering shuttering inculding necessary support for plane surfae foundation and basement and in all floors for RCC column footing column plinth beam roof slabs, strircase steps bed blocks critical
Square column
Below GL
8.31 to 9.30m ht
10.31 to 11.30m ht
For Plan surface
Below GL
From 0.00 -3.30m
From 5.30m to 6.30 m
From 8.30m to 9.30m above G.L
From 11.30 m to 12.30m
Upto 0-3.30m height
From 5.31-6.30m Height
Supply and fabrication of steel including cost and conveyance and labour charges etc complete.
Painting two coats over new plastered using approved cement paint including cost and conveyance of all materials to site and all labour charges etc comoplete
Supplying and Fixing in Position of Cut Stone set in Cm 1:3 using well dressed cut stone supporting inlet pipe inside the tank and as directed by the officers
Provision for pipe connection arrangements for inlet outlet, scour and overflow etc., includeing cost of pipes, specials, valve, labour charge for lifting, aligning, cutting, threading, fixing and painting of GI pipes with two coats of approved quality enamel paint etc., complete as detailed below.
For Inlet Arrangements
80mm GI Pipes
80mm GI Coupling
80mm GI Bend
80mm GI Flange Set
90mm PVC Threaded Coupler
For Outlet Arrangements
80mm GI Pipes
80mm GI Coupling
80mm GI Bend
80mm GI Flange Set
80mm GM Gate Valve
65mm GM Gate Valve
90mm PVC Threaded Coupler
90mm x 63mm PVC Reducer
For Source Arrangemets
80mm GI Pipes
80mm GI Coupling
80mm GI Bend
80mm GI Flange Set
80mm GM Gate Valve
90mm PVC Threaded Coupler
For Overflow Arrangements
80mm GI Pipes
80mm GI Coupling
80mm GI Bend
80mm GI Flange Set
90mm PVC Threaded Coupler
Labour Charges
80mm GI Pipe - Cutting
80mm GI Pipe - Threading
Fabrication,supply, delivery and fixing of outside MS ladder of 45cm wide made out of 50x50x6m MS angle for sides and steps in 16mm MS plain rods fixed at 30cm centre to centre welded, jointed etc., providing with suitable side supports, clamps, and locking arrangements provided with one coat of red oxide paint for providing access to roof top of 10,000 lit. capacity OHT of suitable inclined length, including bottom anchorage and 6transportation and as directed by
Supply and delivery and fixing position of CI man hole cover and frame of Size 60x60cm on roof slab and as directed by the officers The manhole frame and cover should be of light duty and conforming to ISI 1726/1974
Supply and Delivery and Fixing in Position of 150mm dia AC Ventilators on the roof Slab and as directed by the officers
Refilling the Foundation for Service reservoir with excavated earth (other than sand) in layers of 15cm thick well rammed,watering and consoildating etc Complete complying with standard Specification as directed by the officers
Providing and fixing of RCC inner access ladder in RCC 1:1:5:3 (one cement, one and half sand and three aggregates) using 20mm HBG stone for OHT including cost of reinforcement, placing grill in position, centering shuttering charges, mixing concrete curing etc., to required height and clear width of 45cm consisting of two Nos. of vertical post of 10cm x 15cm and step slab of 25mm x25mm etc., complete and as directed by Board officers.
Laying and Jointion of Pipeline works
90mm PVC 6Ksc Pipes
90mm PVC Threaded Coupler
Earth work excavation and depositing on bank with initial lead and lift in all soil for etc Complete
Refilling with exvacated soil (other than sand ) complying with the standard speicfication for filling in foundation and beasement
Laying and jointing of PVC pipe into trench for etc Complete
GST Amount for providing service to Government contract works for the above construction works. { GST amount is the Total GST amount for total overall quoted amount above this row in column "BB" for all works in this package}
LOKESH
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .