| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.5 CrAccepted-AOC 205 KRISHNA NAGAR GOLA KA MANDIR NEAR AIRTEL TOWER NO 01 MORAR GWALIOR 474005 | GWALIOR | GWALIOR | MADHYA PRADESH | 474005 | ₹4.5 Cr | L1 | Accepted-AOC Being reasonable and lowest |
| 2 | L2₹4.9 Cr+₹38.3 L (8.49%)Rejected-AOC | ₹4.9 Cr+₹38.3 L (8.49%) | L2 | Rejected-AOC Not being lowest |
| 3 | L3₹5.7 Cr+₹1.2 Cr (25.8%)Rejected-AOC | ₹5.7 Cr+₹1.2 Cr (25.8%) | L3 | Rejected-AOC Not being lowest |
| 4 | L4₹5.7 Cr+₹1.2 Cr (27.3%)Rejected-AOC UNIT B2 AUTONAGAR VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530012 | VISAKHAPATANAM | ANDHRA PRADESH | 530012 | ₹5.7 Cr+₹1.2 Cr (27.3%) | L4 | Rejected-AOC Not being lowest |
| 5 | L5₹5.7 Cr+₹1.2 Cr (27.3%)Rejected-AOC | ₹5.7 Cr+₹1.2 Cr (27.3%) | L5 | Rejected-AOC Not being lowest |
Tender Value
₹5 Cr
EMD Value
₹5.8 L
Closing Date
5 Feb 2024, 6:00 pmClosed
Chief Engineer
HQ Chief Engineer Chennai Zone
PROVN OF BLDG FOR ADVANCED DATA PROCESSING CENTRE (ADPC) WITH ALLIED INFRA STRUCTURE AT ASC CC BANGALORE
2023_MES_632438_1
88550/E8
Open Tender
Civil Works
Lump-sum
365 days
GE Project Bangalore
As per tender documents
8 documents required · 8 mandatory
₹2,000
GE (P) Bangalore
₹5.8 L
23 Feb 2024
12 Dec 2023
7 Feb 2024
13 Dec 2023
5 Feb 2024
24 Jan 2024
13 Dec 2023 - 20 Dec 2023
Amount
Lumpsum price worked out by the tenderer for BUILDINGS / STRUCTURES as listed in Schedule ‘A’ Part-I
Lumpsum price worked out by the tenderer for SITE CLEARANCE as listed in Schedule ‘A’ Part-II
Lumpsum price worked out by the tenderer for DEMOLITION as listed in Schedule ‘A’ Part-III
Lumpsum price worked out by the tenderer for INTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-IV
Lumpsum price worked out by the tenderer for INTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-V
Lumpsum price worked out by the tenderer for EXTERNAL WATER SUPPLY as listed in Schedule ‘A’ Part-VI
Lumpsum price worked out by the tenderer for EXTERNAL ELECTRIC SUPPLY as listed in Schedule ‘A’ Part-VII
Lumpsum price worked out by the tenderer for ROAD/PATH/CULVERT as listed in Schedule ‘A’ Part-VIII
Lumpsum price worked out by the tenderer for SEWAGE DISPOSAL as listed in Schedule ‘A’ Part-IX
Lumpsum price worked out by the tenderer for AREA DRAINAGE as listed in Schedule ‘A’ Part-X
Lumpsum price worked out by the tenderer for RAIN WATER HARVESTING as listed in Schedule ‘A’ Part-XI
Lumpsum price worked out by the tenderer for COOLING APPLICANCES as listed in Schedule ‘A’ Part-XII
Lumpsum price worked out by the tenderer for LIGHTNING PROTECTION as listed in Schedule ‘A’ Part-XIII
SCHEDULE 'A' PART XIV (MISCELLANEOUS ITEMS) Note: This schedule is not pre-priced by MES
Supply and fixing fancy type two way bib tap 15mm bore chromium plated cast copper alloy screwed for iron pipe or for brass ferrule all as specified and directed
Material and labour for Point wiring complete with 1.5 sq mm single core PVC insulated FRLSH unsheathed cable 1100 volts grade with multi stranded copper conductor confirming to IS-694 1990 wih ISI marked (for phase, neutral and earth) in and including non-metalic rigid PVC conduit medium grade with ISI Mark of minimum 20mm dia and all conduit accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal boxes thickness not less than 1mm alongwith suitable size modular cover plates with frames for fixing modular switches and sockets, fan regulators etc. of suitable size modules and the earth wire to be connected to common earth dolly complete all as specified and directed for the following :- Note: Location of light points, 6 Amp socket points and light fittings may be decided by Engr-in-charge as per site/user requirement
(a) One light point controlled by one modular switch 6A one way
(b) One Ceiling/Exhaust fan point controlled by one modular switch 6A
(c) One 3 pin socket out let 6 Amps on independent board
(d) One 3 pin socket out let 6 A on same board
(e) One light point controlled by two(2)- way modular switch 6 A
Material & Labour for Point wiring complete all a specified with 1100 Volts grade 4 sq mm single core PVC insulated FRLSH cable 1100 volts grade with multi stranded copper conductor conforming to IS 694 1990 with ISI marked (for phase, neutral and earth)in and including non-metallic rigid PVC conduit medium grade ISI Mark of minimum size 20mm dia all accessories concealed including cutting/ chases in wall/ceiling/fixed to roof/truss/columns etc and including factory made branded make embossed galvanised steel pressed terminal boxes for fixing modular sockets thickness not less than 1mm of suitable size modules and the earth wire to be connected to common earth dolly all as specified and as directed.all as specified and as directed for One three pin modular switch socket 16 amps outlet on independent board complete all as specified and directed
Supply & Fix slim surface mounted round 12 W light fitting LED panel aluminium die cast body with premium diffuser to ensure glare free &even distribution of light 12W, 220V,AC, 6000 K LED light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed
Supply & Fix modular type 1 module RJ 11 telephone socket with shutter complete all as specified and directed .
Supply & Fix modular type 1 module TV socket complete all as specified and directed .
Supply & Fix modular type 1 module RJ 45 cat 6 socket with shutter complete all as specified and directed.
Supply & Fix pop up type flush mounting box brushed stainless steel finish 3 module equipped with push and slide locking system to avoide accidental opening by feet and arteor socket outlet complete all as specified and directed .Make: Legrand Arteor Cat. Part No. 0540 20 or all as mentioned in list of approved makes here in after.
Supply & Fix metal flush mounting box 3 module for installation of pop up box floor box in concrete floor equipped with koockouts for 20/25 mm conduit complete all as specified and directed Make: Legrand Arteor Cat. Part No. 05400 00 or equivalent in Honey well or OBO or all as mentioned in list of approved makes here in after.
Supply & Fix MCCB Vertical DB TPN 6 way having degree of protection as per IP-43 with metal door ( double door) 415 V complete with 250 Amps rated copper bus bar with neutral link with provision for 4 pole MCCB as incomer and MCBs as outgoing complete all as specified
Supply & Fix Single pole and neutral enclosure with a two pin and earth plug and socket DB complete with one double pole MCB 32 A suitable for flush mountiung with neutral link complete all as specified and directed by the engineer-in-charge. Make: Legrand Cat. Part No. 5078 63 or equivalent in Havells & Indoasian or all as mentioned in list of approved makes here in after.
Supply & Fix MCCB vertical DB TPN 4 way having degree of protection as per IP 43 with metal door (double door) 415 Volts complete with 250 Amps rated copper bus bar with neutral link with provision for 4P MCCB as incomer and MCBs as outgoing complete all as specified and directed
Supply & Fix MCCB FP 415 volts, 25KA 200 Amps with thermal magnetic adjustable type complete all as specified and directed
Supply & Fix MCCB FP 415 volts, 25KA 160 Amps with thermal magnetic adjustable type complete all as specified and directed
Supply & Fix MCCB FP 415 volts, 25KA 100 Amps with thermal magnetic adjustable type complete all as specified and directed
Supply & Fix GI Bracket made out of GI tubing medium grade 25 mm bore , approx length 1.5 m long including MS clamps made out of MS flat iron 25 x 6 mm , nuts, bolts, washers etc and including before fixing applying two coats of aluminum paint over a coat of red oxide primer including removing the old existing GI bracket from bldg complete all as specified and directed.
Supply ,fix, test and commissioning of wall mounting fan of 450mm with all fixing arrangement all as per model Airboll Hi speed of havells or techno commercial equivalent of other specified makes connecting up including provision of 3 core flexible copper wire of suitable size all as specified and directed .
Material and Labour for construction of valve chamber 900x900x900 mm depth with PCC foundation in the ratio 1:4:8 brick work cement mortar in the ratio 1:6 using of class B bricks , PCC 1:2:4 type B0 using 12.5 mm aggregate at the top , plastering 15 mm thick in the ratio 1:4 including MS sheet cover 3mm thick with angle iron frame 50x50x6mm locking arrengement complete with painting on steel surface with two coatsof synthetic enamelled paint over one coat of red oxide paint all as specified and directed . (Earth work shall be measured and paid separetely in the respective Items)
Supply and fix pole mounted FRP box weather proof type with hinged type door of white colour of size 250x181x98 mm with 4 way PVC connector including 1 No MCB SP 6 amps and with suitable clamping arrangements for street light fittings all as specified and directed.
Material and Labour for Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure all as specified and directed.
Material & Labour for construction of Transformer for foundation suitable for 315 KVA as per OEM drawing inlcuding excavation in trenches in hard/dense soil, PCC 1:4:8 type D2 bed concrete , RR stone masonry in CM 1:6 for foundation, plastering in CM 1:4, 20mm thick including PCC coping and RFR , removal of surplus soil and three coats white wash etc complete all as specified and directed.
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral copper bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and direc ted with the following switch gears:- ( Main LT panel)
Aluminium bus bar 3 phase & neutral of suitable capacity
MCCB, 4 pole 500Amps, 35KA - 01 No (Incoming)
MCCB, 4 pole 400 Amps,35 KA -01 No (Outgoing APFC)
MCCB, 4 pole 500 Amps,35 KA - 01 No (Outgoing Sub DG Panel)
MCB, TPN 40 Amps,35 KA - 01 No (Spare)
Supply, Installation, testing and commissioning of LT feeder pillar box, factory made, CPRI approved, outdoor type floor mounting with channel iron pedestal frame made out of 3 mm thick CRCA sheet steel for outer body and 2 mm thick for inner partition, compartmental type, dust proof, free standing, suitable for working on440 volts 3 phase 50 Hz A C supply, vermin proof, front and rear opening, hinged doors etc powder coated as per seven tank process and IP 65 protection, cable alley, cable entry hole at the bottom, earth strip 25x4mm , 3 phase and neutral copper bus bar suitable capacity with non adhesive color coded insulation sleeves mounted on insulators, drilled holes on bus bar strips for tapping including nuts bolts and washers, copper strips of suitable size for connecting MCCB, Digital Voltmeter, digital ammeter with suitable rated CTs, LED phase indication lamps & PCC works complete all as specified and directed with the following switch gears:- (SUB DG panel)
Aluminium bus bar 3 phase & neutral of suitable capacity
MCCB, 4 pole 500 Amps,35 KA -01 No (Incoming)
MCCB, 4 pole 160 Amps,25KA - 01 No ( Outgoing For Bldg Load of Ground Floor)
MCCB, 4 pole 160 Amps,25KA - 01 No (Outgoing for Bldg Load of First Floor)
MCCB, 4 pole 100 Amps,35KA - 01 No (Outgoing for G.F.AC Load )
MCCB, 4 pole 160 Amps,35KA - 02 No (Outgoing for F.F.AC Load ) + Spare
MCCB, 4 pole 125 Amps,35KA - 01 No (Outgoing for UPS Load)
MCB SPN 40 Amps ( Outgoing for Street light))
Supply, installation, testing and commissioning of 320 KVA (The capacity of Generator set shall be net after all due derating factors as per relevant lSI standard), silent Diesel engine Generating Set, 415 volts, 3 phase, 0.8 Power factor, 50 Hz, 4 wire system as per IS 10001/10002 , developing suitably derated of Minimum BHP @ 1500 RPM, Liquid Cooled, electric start coupled to alternator as per IS 13364 mounted on a common base frame with standard control panel for automatic starting on main control panel having meters, sound proof canopy, integral fuel tank with battery and leads and accessories complete in all respect with emission control device to control the PM within range as prescribed by NGT/ CPCB latest norm as per notification issued by MOEF suitable for ambient condition at Bangalore including required PCC foundation as per manufacturers specification and conforming to conditions under IS 10004722/1460 BS 5514/2613/ 5000 ISO 8526/3046 with following provisions all as specified and directed:-
(A) Alternator :- Standard design alternator rated at 320 KV A net output at site after considering derating as per site conditions at 0.8 (lag) power factor AC, 3 - phase 4 - wire 415 volts 50 Hz, 1500 RPM, self exicited self regulated screen protected drip proof IP 23 enclosure brushless design with widing in pole faces, insulating class 'H' and voltage regulation of ± 1 % at rated voltage from no load to full load. The alternator shall be confirming to BS 2613/5000 and shall be inposition to generate supply with frequency regulation with in ± 1% tolerance. The alternator will be suitable for tropical climate and shall generally confirm to BS - 2613/50001 IS - 4722 and as per the following provisions all as speicied and directed:- Make:- KIRLOSKAR/JYOTI / STAMFORD/CATERPILLAR or as mentioned in approved list of manufacturer here in after
(a) Insualation class - 'H' (b) Temparature rise Class - 'H'
(c) Excitation: Self Excited (d) Regulation performance: The voltage is kept constant with ± 1 %, manual voltage adjustment within ± 5%
(e) Frequency regulation ± 1 % (f) UG cable of suitable size from Alternator to AMP is deemed to be include in quoted rate. (g) Antivibration Pads
(B) Diesel Engine: - Adquate capacity Diesel engine suitably derated of Matching BHP for 320 KVA coupled drive independently above alternator and after considering derating as per site conditons after generating and reducing power consumed by accessories, directly coupled through flexible coupling, multi cylinder multi stroke direct injection, cold starting 1500 RPM, as per relevant ISI/BS - 5514 with an overload capacity of 10% for one hour in 12 hours continuous running complete with standard accessories all as specified and required for safe handling and operation salient features of accessories shall be as under:- Make :- KIRLOSKAR/CUMMINS / CATERPILLAR (GEMCO)/ GREAVES - COTTON/ ASHOK LEYLAND as mentioned in approved list of manufacturer here in after.
(a) Fly wheel with housing (b) Cooling system :- Mounted radiator with fan & belts. (c) Cooling pump: - Centrifugal type belt driven. (d) Exhaust System :- Exhaust System complete with exhaust piping of suitable dia as per manufacture standard with MS pipe light grade upto and away two meters height from top of enclosure incluing necessary angle iron frame supports from floor to the bottom of exhaust pipe from the enclosure covered with mineral wool of thickness 50mm rapped with chicken wire mesh of size 2.25mm and aluminium sheet of 24 SWG to be complete with in the enclosure for safe exhaust without transforming vibration to the wall of the enclosure. Exhaust gas turbo charger type Exhaust manifold Silencer: Residential type Bellows
(C) Fuel System :- Fuel injection system with fuel injectors, fuel injection solenoid switch/nozzles/ governer electronic type capable for 1 % speed /frequency regulation. (i) Fuel filters (ii) Fuel hoses (iii) Lub oil System :-
(iv)Lubricating oil filter (v) Lubricating oil pump
(vi) Air Intake System :- (a) Air intake Manifold (b) Air cleanler dry type (D) Governer :- Electronic Governer (a) Starting System :- Electric Self starter with maintenace free batteries including battery charging alternator. (b) Batteries:- Required capacity and size Battery complete with copper conductor multistrnded leads of suitable length from self starter to the battery terminals complete with initial charge and initial fill of electrolite all as specified. Make:- EXIDE / AMRON / Produced by original DG set manufacturers
(i) Starter gear ring (ii) Start and stop push button (iii) Ignition key / Switch (iv) Handling and operation: Salient features of accessories shall be as under:
(a) Radiator with blower fan (b) Corrosion inhibitor coolant (c) Paper element filters for fuel, lub oil and by pass. (d) Eelctronic governer controlled direct fuel injection system (e) Fly wheel housing and fly wheel. (E) Generator Monitoring Panel: Comprising of following:- (a) Microprocessor based integrator generator set monitories, metering, protection and control system with built torque matched volts/H3 over load control. (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) (c) Alternator protection parameters like under voltage, over current, under frequency, over frequency ( alarm & shut down) (d) Relay drivers for remote annuciations (e) Cyclic cranking (f) Auto/manual start stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0- 50°C and humidity upto 95% (j) Remote monitoring capabilty through separate interface modules
(F) AMF PANEL:- (a) Auto Main Failure (AMF) panel made out of minimum 2 mm thick CRCA sheet, powder coated of conforming to IS 8623 totally enclosed dust and vermin proof with front and rear openings of 415 Volts, 3 Phase,4 Wire, AC 50 Hz having aluminium bus bar capacity required to carry current at 100% load of DG set with three phase and half neutral colour coded, prewired with copper flexible cable, be all as specified with the following accessories, control cable from Gen set to AMF panel:-
(i) 4 pole contactor of suitable capacty - 2 Nos. (ii) MCCB, 4 Pole as per OEM design -2 Nos (One for Alternator and one for Commercial Supply) with suitable fuse links. (iv) CTs suitable rating for both the supplies. (v) DC Ammeter. (vi) DC Voltmeter. (vii) Push buttons. (viii) Indication Lamps.
(ix) 2 over load+ earth leakage relay. (x) Multi functional digital meter for KWH,KVA,KW,Amps,volts, frequency, power factor etc. (xi) SMPS Battery charger 12V, with trickle & Boost charging (xii) On/ Off switch. (xiii) Automatic/manual switch. (xiv) Hooter. (xv) Voltage sensing relay.
(xvi) Six window anunciator for fault indications. (xvii) Electro magnetic relays. (xviii) Metering required in DG set :- A, V, Hz, KVA, KW, PF & KWH Metering required in mains :- A, V, Hz.
(G) Acoustic enclosure: CPCB approved enclosure is free standing floor mounted factory built and modular in construction to facilitate easy assembly at work site and will be drop over housing type. It will consist of acoustically treated panel housed in sheet steel will provide easy access for maintenance, repairs and operation. The enclosure is custom built to suit conditions, with the following features:-
(a) Custom built product for various equipments, with ensure the optimum performance without duration. (b) Rugged in construction maintenance free and modular designs which facilitate easy at site. (c) 16 SWG (1.6 mm) thick CRCA sheets to be used for enclosure panel to ensure longer life against weathering action. High quality acoustic insulation materials to be used as per IS 8183 for maximum sound absorption. Acoustic layers are supported by perforated sheets. (d) Sheet metal components of the enclosure should undergo various stages of surfacetreatment prior to painting which leads to be better life of the enclosure against weathering action.
(e) Special paint treatment with pure polyester powder/epoxy to be provided for better weather resistance. (f) Well designed ventilation system to be provided to pump up the heat in the chamber efficiently. (g) For effective acoustic / weather sealing a special type weather sealing gaskets, new frame rubber gaskets to be used.
(h) Working space is to be provided around tbe equipment for easy maintenance / repairs. (j) Necessary cut out provision for entry and exist of fuel lines cable to be incorporated in the enclosure as per tbe requirement.
(k) A see through transparent window (glass or acrylic) in front of engine panel to be provided for monitoring the operation. (l) Ducting if required, bellows, mechanical hardware like locks, hinges fasteners etc to be provided. (m) Deliverables. 75 dBA @ imtr at 75% load under free field conditions. The temp inside tee enclosure will be within as per manufacturers recommendations above ambient temp. (n) The enclosure should be provided witb bulk head light fitting for inside illumination (o) The battaries should be placed inside the enclosure beside the DG Set on a suitable inlsulated platform. (p) The DG Set should be provided with external Emergency stop push button. (q) The accoustic enclosure parts shall be of powder coated after pre treatment process. (r) The powder coating shade should be Genset Green. The base frame should be painted with epoxy based black shade.
Make for AMF PANEL: DG SET OEM Make for ACCOUSTIC PANEL: DG SET OEM (H) Civil Works :- All civil works with PCC plat form and related to foundations including of panel and equipments and making good the existing structrure of distrubed during installtion and commissioning of Genset. The depth of the foundation shall be minimum 300 mm with antivibration pads or as recommended by the manufacturer. The following provisions are deemed to be included in the rate quoted for DG set:- (a) The quoted rate shall be deemed to be inclusive of first fill of lubricant oil and final successful acceptance test. (b) DHPP for testing purpose shall be supplied by the contractor without any extra cost to department. (c) The contractor shall arrange for artificial load for testing for final testing of DG Set at site and the cost is deemed to be including in above offer. (d) Testing of sound level should be carried out at the site in presence of GE (c) The quoted rate shall be deemed to be inclusive of test run at site including of one hour on 10% overload as directed by engineer-in-charge in presence of representative detailed by accepting Officer, all arrangements are to be made by the contractor for tests. (d) Rate quoted shall be deemed to be included in making necessary holes to walls and making good the distrubed surfaces to match to original specification and connecting up all as specified and directed. (e) The quoted rate shall be deemed to be inclusive the PCC foundation as per Manufacturer's recommendation and all connected civil works
Material and Labour for earthing of machinery/equipment Installed at power house/substation complete using galvanized steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the earth plate at a depth of not less than 1.5 mtr below ground level connected to galvanized iron strip 32x 6 mm as earthing lead by means of bolts, nuts and washers made out of GI/steel earth strip protected by GI light grade pipe of 40 mm dia and connecting to main panel board/switch board/control board all as shown in electrical plate No 3 of SSR Pt I incl PCC chambers in 1:2:4 and RCC cover slab with 8mm dia MS bars reinforced at 10 cm center to center both ways incl earth work like excavation, returning filling back disposal etc complete all as specified and directed.
Note :- The rate is deemed to be inclusive of the cost of earth work, excavation on any type soil and removal of surplus soil to a distance of 50 Mtrs, PCC 1:2:4 type B1 for earth pit cover 6 Nos 6 mm dia CTD bar on both direction, earth lead protection GI pipe medium grade with suitable size from earth plate electrode to main switch, GI strip length up to 7.50M will be measured as one unit)
Supply and fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230 V with accuracy of ± 2.5% and of capacity 1 KVA all as specified and directed.
Supply , install , testing &commissioning of 1.5 TR capacity wall mounted spilt air conditioner 5 star rating inverter type fitted with hermitically sealed compressor operating on 220 V+/- 10% , 50 Hz, single phase AC supply with evaporator and condensing unit made of copper tubes with aluminum fins, cordless remote control, copper piping for both suction and discharge of suitable length as per site with insulation for piping , power and contol cabling as per site requirement , MS outdoor stand duly painted, comprising of following complete as per reqmt (a) Insulated copper pipe line liquid and suction line as per manufacturer reqmt/ site reqmt (b) Flexible copper cable between indoor, stabilizer and outdoor unit of suitable size as per manufacturer recommendation. (c) Drain pipe with suitable length (d) Suitable size of insulation for covering of refrigerant line.
Supply , install , testing &commissioning of 2.0 TR capacity wall mounted spilt air conditioner 5 star rating inverter type fitted with hermitically sealed compressor operating on 220 V+/- 10% , 50 Hz, single phase AC supply with evaporator and condensing unit made of copper tubes with aluminum fins, cordless remote control, copper piping for both suction and discharge of suitable length as per site with insulation for piping , power and contol cabling as per site requirement , MS outdoor stand duly painted, comprising of following complete as per reqmt (a) Insulated copper pipe line liquid and suction line as per manufacturer reqmt/ site reqmt (b) Flexible copper cable between indoor, stabilizer and outdoor unit of suitable size as per manufacturer recommendation. (c) Drain pipe with suitable length (d) Suitable size of insulation for covering of refrigerant line.
Supply and Fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized 230V with accuracy of +/- 2.5% and of capacity 4 KVA complete all as directed and as specified
Supply and Fix Voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input voltage variation between 170 V to 250 V with output voltage stabilized 230V with accuracy of +/- 2.5% and of capacity 5 KVA complete all as directed and as specified
Supply and laying 150mm internal dia DWC HDPE SN-8 pipes confirming to IS 14930 part-2 / IS 16025 Part-24, laying including all necessary specials, cutting and jointing as specified and directed.
UNITED TECHNO PROJECTS PVT LTD
SIGNATURE INFRASTRUCTURES(E DHARANI KUMAR REDDY)
GOPAL TEKNOCON PRIVATE LIMITED
Sai Ram Builders
AFSON ENGINEERS & CONTRACTORS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .