Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC | L1 | Accepted-AOC Lowest Reason | |
| 2 | L2₹15.0 L+₹5,911.40 (0.40%)Rejected-Finance | L2 | Rejected-Finance Not Lowest Bidder |
Tender Value
₹18.8 L
EMD Value
₹37,500
Closing Date
11 Jan 2022, 6:00 pmClosed
GE Dronachal
GE Dronachal, Dronachal Top, Neori Hills, Bhopal 462038
PROVN OF ONE STORE ROOM FOR REGIMANTAL STORE OF 7021 EME BN, PROVN OF AC AND CONNECTED WORKS IN SIGNAL COMMUNICATION CENTRE AND SPL REPAIR TO REPLACEMENT OF UNSV BER CEILING FANS UNDER GE DRONACHAL, BHOPAL
2021_MES_494452_1
8663/E8
Open Tender
Civil Works
Item Rate
180 days
Bhopal
Class-E, Category a (i) and b (i) and as per NIT documents
6 documents required · 6 mandatory
₹500
GE Dronachal
₹37,500
Yes
9 Feb 2022
14 Dec 2021
13 Jan 2022
14 Dec 2021
11 Jan 2022
28 Dec 2021
14 Dec 2021 - 28 Dec 2021
Amount
M&L for surface dressing n. exc 15 cm in depth in hard/dense soil complete all as specified.
Excavating in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth for foundation in soft/ disintegrated rock and getting out complete.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm.
Removing excavated rock material to a distance n exc 50 m and deposited where directed at a level n exc 1.5 m above the starting point.
M&L for PCC 1:4:8 (Type D2) using 40 mm graded stone aggregate as in foundation filling and mass concrete.
M&L for ATT to back filling in contract with fdn @ 7.5 Ltr of emulsion per Sqm of vertical surface area complete all as specified and directed.
M&L for Treating the top surface of filled earth at the rate of 5 litres of emulsion per square meter of surface complete all as specified and directed.
M&L for Treating the soil under plinth protection at the rate of 5 litres of emulsion per square meter of surface area complete all as specified and directed.
M&L for Treating the soil along with external perimeter of building at the rate of 2.25 litre of emulsion per metre of the perimeter wall complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) Foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under-reamed piles and mass concrete
M&L for Reinforced cement concrete design mix M-25 using 20mm graded stone aggregate) in Columns, pillars, piers, posts and struts complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) in roof beams , cantilevers , bressummers , lintels over 1.5 m span complete all as specified and directed.
M&L for Reinforced cement concrete design mix M-25 (using 20mm graded stone aggregate) in Slabs supported on walls,beams and columns in floors, roofs/chajja, landings, balconies, canopies, deck slabs and in shelves and the like roof complete all as specified and directed.
M&L for Reinforcement 10mm dia and over TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia complete all as specified and directed.
M&L for Reinforcement 6mm to 8mm dia TMT bars cut to length, bent to shape required and binding with MS wire not less than 0.9mm dia in roof slab/chajja complete all as specified and directed.
Ditto, but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed.
Formwork to sides of concrete foundations, footings, bases of columns and similar work for fair finished flat surfaces of concrete complete all as specified and directed.
Formwork to plinth beams and similar work for fair finished surfaces of concrete complete all as specified and directed.
Formwork to sides of pillars, columns for squred, rectangular or polygonal fair finished surfaces of concrete complete all as specified and directed.
Formwork to sides and soffits of floor or roof beam etc For fair finished flat surfaces of concrete complete all as specified and directed.
Formwork to soffits of suspended slabs as roof slabs, floor slabs, landinqs, lintel / chajja and similar work not exceeding 200 mm thick for fair finished flat surfaces of concrete complete all as specified and directed.
Use and waste of formwork to edges of concrete flats ,treads, break in floors window cills, concrete railing , opening in concrete wall, floor and roofs n exc 20cm wide and sides of RCC/PCC bands in walls , horizontal or sloping and similar work exc 10 cm but n exc 20 cm wide to rough finish surface of concrete flat.
M & L for Brick work with flyash bricks, modular size ,straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed.
M&L for Brickwork with flyash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM 1:4 complete all as specified.
M & L for rendering 10mm thick cement plaster 1:6 on brick masonry wall surfaces finished even and smooth without using extra cement ( internal) complete all as specified and directed.
M & L for rendering 10mm thick cement plaster 1:6 including 5 mm thick in CM 1:4 with WPC on brick masonry wall surfaces finished even and smooth without using extra cement ( External) complete all as specified and directed. Note : WPC shall be measured and paid separately
M & L for Rendering 5 mm thick on concrete surfaces of internal ceiling in cement plaster 1:3 finished even and smooth without using extra cement(ceiling) complete all as specified and directed.
Supply only Integral waterproofing compound
S& F 12mm thick toughened glass Door/window all as specified and directed
S&F over panel side connecting patch with pivot (Big) L all as specified and directed
S & F stainless steel handle H type, suitable for glass shutter, having min 300mm gripping length.
S& F top patch and bottom patch
S& F double action floor spring, hydraulically regulated, with stainless steel cover, ISI marked and approved complete all as specified and directed.
M&L for approved earth filling under floor incl spreading and levelling in layers including watering and ramming complete all as specified and directed by Engr-in-Charge.
M&L for Hardcore of gauge Broken stone or boulders n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engr-in-Charge.
M&L 75mm PCC 1:3:6 type C2 using 40mm graded stone aggregate as in plinth protection and hard standing complete all as specified and directed by Engr-in-Charge.
M&L for 75mm thick Cement Concrete 1:4:8 type D-2 (40mm graded aggregate ) in sub base of floors complete all as specified and directed by Engr-in-Charge.
M&L for screed bed 15mm thick in CM 1:4 complete all as specified and directed by Engr-in-Charge.
M&L for dark shed vitrified ceramic tile 9-10mm thick as in skirting, vertical surface dadoes and riser etc cover and including 10mm thick rendering in CM (1:4) complete all as specified and directed.
M&L for Dark shade vitrified ceramic tile 9-10mm thick (square/rectangle) polished area of each tiles not exceeding 0.36sqm in floors etc set with suitable adhesive mix with cement per manufacture instruction over cement slurry set and jointed in neat cement slurry and pointed in white or coloured cement match
M&L for preparation of new plastered wall surface and applying two coat of putty (1mm thick avg) over a coat of alkali resistance primer
M&L for two coats of water base exterior emulsion paint over a coat exterior wall all as specified and directed (make :- asian apex ultima (finish high sheen ) berger -weather coat long life (finish high sheen ) dulux:- weather shiled max or equivalent as approved by GE) on wall as specified and as directed by Engr-in-Charge..
M&L for Preparation of new decorated surfaces of wall applying two coat of oil bound distemper over & inculding a coat of white cement base putty complete all as specified and directed by Engr-in-Charge..
M&L for Three coats of white wash including preparation of new ceiling surfaces complete all as specified and directed by Engr-in-Charge..
M&L for screed bed 20mm thick in CM 1:6 complete all as specified and directed by Engr-in-Charge.
M&L Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including grinding and polishing complete all as specified and directed by Engr-in-Charge.
Supply and fixing 12mm thick seamless calcium silicate ceiling made out of 1800 x 1200 mm size board of siliceous & calcareous material reinforced with cellulose fiber fixed to the ceiling section with 25 mm long self drilling & tapping screws having Phillips head with under head cutter at 200 mm C/C including finishing the joint of face board with specially formulated jointing compound & 48 mm wide fiber tape to provide seam less finish Note :- Frame work for ceiling shall be measured & paid separately
Material and labour GI frame work, size of grid 605 x 605 mm, for seamless ceiling comprising of GI perimeter channel 0.55 mm thick with two unequal flanges of 20 and 30 mm and web of 27 mm fixed to surrounding wall using nylon sleeves and screws at 450 mm centre tocentre / intermediate channel 0.9mm thick having two equal flanges of 15 mm each and web of 45 mm suspended from soffit at approx 900 mm centre to centre with cleat and steel expansion fasteners with and including ceiling section (not exc 1.2 m length) of 0.55 mm thickness having kurled web of 50 mm and flange of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with connecting clips across the intermediate channel at 457 mm centre to centre, complete all as specified and directed.
Material and labour for preparation of new calcium silicate false ceiling surface and applying two coats of oil bound distemper complete all as specified and directed.
Supply and fixing 100mm wide factory made glass reinforced cement decorative moulded type wall cornice of approved design fixed at site as per manufacturer's instruction.
M & L for 10mm thick rendering in CM 1:4 mixed with WPC over RCC roof slab while the concrete is still green finished even and smooth without extra cement complete all as specified and directed. Note : WPC shall be measured and paid separetely.
M & L for applying one coat of bonding material using blown type bitumen conforming to IS-702 grade 85/25 @ 1.20 Kg/sqm over a bitumen primer on finished plastered surfaces completed all as specified and directed
M & L for APP based polymeric membrane minimum weighing 3kg/sqm and minimum 3mm thick reinforced with polyester non woven fabric (wt not less than 150 gms/sqm) laid on primed surface by forced application complete all as specified
M & L for 25mm PCC 1:2:4 type B0 (using 12.5mm graded stone aggregate) as in levelled course finish even and fair for tile finishes specified and directed
M & L for 20-25mm thick PCC tiles using grey cement of size 250mmX250mm ISI marked over 15mm thick bedding morter in cm 1:3 set and jointed completed all as specified and directed.
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 1.5 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/pressed steel sunken boxes( with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, including PVC insulated multi-stranded copper conductor 1.5 Sq mm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed by Engr-in-charge at site for the following:-
(a) One light point controlled by one switch.
(b) One ceiling Fan/ Exhaust Fan point controlled by one switch.
(f) One 3 pin socket outlet 5 Amps on independent board.
(g) One 3 pin socket outlet on same board with other switches
Point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits), with multi-stranded copper conductor 4 Sq. mm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 volts grade, ISI-694 marked with valid CML No. in and including medium grade, PVC concealed conduit and conduit accessories concealed in wall/roof/floor etc, ISI marked with valid CML No.(IS-9537-1983 for conduits and IS:3419:1976 for conduit accessories), with mild steel/ pressed steel sunken boxes with earth dolly duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally, and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets etc, including PVC insulated multi-stranded copper conductor 4 Sq mm nominal cross sectional area single core cable as earth continuity conductor to common earth and connecting to earth dolly complee all as specified and directed by Engr-in-charge at site for the one 3/5 pin 15/16 amps socket outlet independent.
Supply and fix switch rating 6 amps single pole one way 230 volt complete all as specified and as directed by Engr-in-charge.
S&F ceiling rose surface bakelite 65X 50mm three terminal complete all as specified and as directed by Engr-in-charge
Supply and fixing of ceiling fan regulator ISI marked, any type complete all as specified and directed by Engr-in-charge.
Supply and fix switch socket combination (ISI marked )2 in 1, 05 Amps flush type complete all as specified and as directed by Engr-in-charge
Supply and fix switch socket combination (ISI marked ) 05/15 Amps flush type complete all as specifierd and as directed by Engr-in-charge.
S & F in repair incl taking down sheet metal enclosure for MCB DB, SPN 230 Volts 200 amps rated busbar 8 way double door complete all as specified and directed by Engr-in-charge.
Supply and Fix MCB single pole with neutral 240 volts 32 to 40 Amps with thimble suitable for existing wires complete all as specified and directed by Engr-in-charge by Engr-in-charge.
Supply and fix MCB SP, 240 Volt, 6-32 Amps, 10 kA rupturing capacity 'C' series complete all as specified and directed by Engr-in-charge.
Supply and fix wall mounted LED batten fittings, 20 watt, 230 Volts extructed aluminium housing provided for efficient heat dissipatuion with polycarbonate diffuser & integrated electronic driver complete all as specified and directed by Engr-in-charge.
Supply and Fix energy saving and environment friendly long life 30 W LED street light made up of pressure diecast aluminium housing with acrylic cover as diffuser with IP66 protection and impact resistance of IK07 toughened glass in the front peanut lens for batwaing light distribution to ensure uniform light distribution complete all as specified and directed by Engr-in-charge
M & L for street light bracket, made out of 40 mm dia GI pipe, (medium grade) 1.5 meter long and fixed to end of pole with cap & necessary fixing arrengement , bend to shape as required and welded and fixing in position complete all as specified and directed by Engr-in-charge.
Earthing complete with galvanised iron earth plate electrode 60cmx60cmx6mm thick , burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised steel wire 4 mm dia by means of galvanised nuts, bolts, check nuts and washers including excavation and earth work, PCC 1:3:6 type C-2 pit, PCC pit cover 1:2:4 type B-1 with handle, GI protection pipe 15 mm bore light grade and 20mm medium grade GI watering pipe, Funnel , wire mesh etc complete as shown in electrical Plate No.3 of SSR Part-I connected to earthing test point and metal part all as specified including testing on completion complete all as specified and directed by Engr-in-charge.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed by Engr-in-charge
Supply and fix in replacement Recess or ceiling mounting as suitable in existing fitting incl making existing surface good ultra slim 36 W LED 2x2 edge-lit tile in Aluminium Extruded housing with full opal diffuser suitable for perfect lighting conditions for most varied visual tasks in offices and general areas complete all as specified and directed.
M and L sand cushioning to PVC/XLPE cables with river sand and punning to provide required cover to UG cables, complete all as specified and directed. Note:- For the purpose of payment only punned thickness will be measured
Sub class 'B' old size well burnt brick laid flate in trenches as protection to LT cable complete all as specified and as directed.
S&F Cable in trenches or passing through pipe or fixing to pole of 1100 volts grade heavy duty cable with XLPE insulated, stranded aluminium conductor, served with inner sheathing of PVC tape, armoured with galvanised steel wire or strip and overall PVC sheathed nominal cross sectinal area 6 Sqmm, 2 core, all as specified and directed.
Supply and lay for tubes 'light grade ' with all fittings laid in trenches/on ground complete of dia 15 mm.
Supply, install, testing and commissioning of BEE 3.2 rated air cooled hi wall spilt unit indoor/outdoor inverter type air conditioners electric driven( 250 Volts, single phase, 50 HZ supply) with Energy efficient Rotary Compressor, working on R-134 or superior environment-friendly refrigerant, cordless remote operated, comprising of indoor unit,wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 4500 KCal/Hr, Minimum Power consumption , Minimum room discharge airflow 700 CuM /Hr Guaranteed cooling capacity(Min) 4275 KCal/Hr, outdoor unit, Material of Cabinet GI Sheet 1.0 mm thick powder coated, Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) and condensate water drainage arrangement etc complete of capacity 2 Ton complete all as specified and directed at site. Note :-(i) The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand. The cost is deemed to be included in the quoted rates.(ii) Additional length for copper tubing if required at site shall be supply &fix in respective items.
Supply, install, testing and commissioning of BEE 3.2 rated air cooled hi wall spilt unit indoor/outdoor inverter type air conditioners electric driven( 250 Volts, single phase, 50 HZ supply) with Energy efficient Rotary Compressor, working on R-134 or superior environment-friendly refrigerant, cordless remote operated, comprising of indoor unit, wall mounted, material of construction of indoor unit ABS, Nominal cooling capacity 4500 KCal/Hr, Minimum Power consumption , Minimum room discharge airflow 700 CuM /Hr Guaranteed cooling capacity(Min) 4275 KCal/Hr, outdoor unit, Material of Cabinet GI Sheet 1.0 mm thick powder coated, Copper tubing, electric connection (Between indoor and outdoor unit located upto a maximum distance of 10 Meters) and condensate water drainage arrangement etc complete of capacity 1.5 Ton complete all as specified and directed at site. Note :-(i) The outdoor unit shall be fixed on wall with standard bracket or fixed on roof /floor with proper MS stand. The cost is deemed to be included in the quoted rates. (ii) Additional length for copper tubing if required at site shall be supply &fix in respective items.
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20 Amp
M&L for sub main wiring with two runs of 4 sqmm single core PVC insulated but unsheathed FRLS copper conductor 1100V drawn through and including rigid heavy duty PVC conduit 25 mm dia with conduit accessories including 4 sqmm PVC insulated but unsheathed FRLS copper conductor used as earth wire
Supply & fixing Sheet metal enclosures for fixing MCBs Single pole and neutral 4 way, 240 volts with 200 Amps rated bus bar with double door fixed on flush to the wall including making the hole in the wall and fixing the DB including cement work and plastering complete all as directed.
Supply and Fixing MCB single pole, 240 volts 6 to 40 Amps capacity
Supply and fixing ceiling fans complete with blades, down roads, electronic regulator and accessories, 230 V, 1400 mm sweep, Min air delivery 245 CFM with service value 6.00 BEE, five star rated with brushless direct current moter (BLDC) complete all as specified and directed by Engr-in-charge.
S & F Glass door lock, stainless steel, suitable for 12mm thick glass shutter, with min 3 Nos keys complete all as specified and directed.
Samaksh Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .