Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹14.6 L+₹1.9 L (14.5%)Rejected-Finance | L2 | Rejected-Finance other than lowest | |
| 3 | L3₹16.2 L+₹3.4 L (26.9%)Rejected-Finance | L3 | Rejected-Finance other than lowest | |
| 4 | L4₹18.0 L+₹5.2 L (40.5%)Rejected-Finance | L4 | Rejected-Finance other than lowest | |
| 5 | L5₹18.8 L+₹6.0 L (47.3%)Rejected-Finance 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L5 | Rejected-Finance other than lowest |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
30 Oct 2020, 6:00 pmClosed
GE (N) DELHI CANTT-10
GE (N) DELHI CANTT-10
REPAIR MAINT OF INTERNAL ELECTRIFICATION WORK INCL REPLACEMENT OF UNSV WIRING SUBMAIN WIRING DBs LIGHT FITTINGS AND FIXTURE OF MD OTM ACCN OF 17 SIKH LI 226 ASC STATION ROAD MOUD ROAD ESD DEPOT FOL DEPOT NO 4 PF AIRPORT RD MAP ACCN KABUL LIN
2020_MES_383248_1
GE/NORTH-55/2020-21
Open Tender
Civil Works
Item Rate
180 days
GE (N) DELHI CANTT-10
as per NIT
8 documents required · 8 mandatory
₹500
Yes
GE (N) DELHI CANTT-10
₹40,000
Yes
7 Dec 2020
3 Oct 2020
2 Nov 2020
3 Oct 2020
30 Oct 2020
17 Oct 2020
Amount
Taking down carefully copper / aluminium point wiring (light / fan socket or power) complete including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc including making good the disturbed surfaces to match with the existing complete
M&L for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall/Surface on wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc and making good to the disturbed surfaces to match the existing complete all as specified and directed for One light / bell point controlled by one, one way switch 06 Amps (Make of wiring cable & PVC conduit - Finolex/Plaza/Polycab/Anchor)
Material & labour for point wiring with 1.5 Sq.mm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed FRLS copper conductor cable with and including continuous earth wire of size 1.5 Sqmm nominal cross sectional area, single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 20mm dia or higher, medium grade complete with and including all PVC conduit accessories surface on wall and replacement of sunk zinc coated pressed steel terminal box of 1.60mm thick with 3mm thick plastic laminated sheet top cover, brass screws, cup washers etc complete all as specified and directed for One light / bell / buzzer point controlled by one, one way switch 06 Amps (Make of wiring cable & PVC conduit - Finolex/Plaza/Polycab/Anchor)
All as per srl item No 02 here-in-before but one fan point controlled by one, one way switch 06 Amps
All as per srl item No 03 here-in-before but one fan point controlled by one, one way switch 06 Amps.
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
All as per srl item No 03 here-in-before but one 3 pin, 06 Amps socket outlet point on independent board controlled by one, one way 06 Amps switch
All as per srl item No 02 here-in-before but one 3 pin, 06 Amps socket outlet point on same board controlled by one, one way 06 Amps switch
All as per Serial Item No 02 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete
All as per Serial Item No 03 above but point wiring with 2.5 Sqmm single core FRLS cables and earth continuity wire of 1.5 Sq mm single core FRLS cable for one 3 pin 15 Amps socket out let point controlled by one, one way switch on independent board complete
S&F switch piano flush type, 06 Amps, single pole, one way, 240 volts complete
S&F bell push, flush type, 06 Amps, 250 volts with switch frame complete
S&F switch piano flush type, 16 Amps, single pole, one way, 240 volts complete
S&F socket outlet 2 in 1, 5 pin, 06 Amps, flush type, 250 volts complete
S&F socket outlet 2 in 1, 3 pin, 06 Amps and 3 pin, 16 Amps, flush type, 240 volts complete
S&F ding dong bell, AC, 230 volts, single pole complete
S&F ceiling fan regulator, stepped type of 0 to 04 rotary steps, electronic, socket size, humfree, AC, 230 volts, 100 watts complete
S&F ceiling rose, 6 Amps, 250 volts, AC, three terminals and PVC / Polycarbonate insulated body of 50 x 25mm size complete
S&F lamp holder, PVC / Polycarbonate type with back plate suitable for batten fitting including 7W LED bulb (Make of Bulb : Wipro/Havells/Philips) complete
S&F in repair 5W LED T5 TL fitting (1 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size complete
S&F in repair 9/10 W LED T5 TL fitting (2 fit) attractive wall mounted type suitable for mirror fittings, all accessories pre-wired including connecting up with twin core flexible copper conductor cable of suitable size complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 6500K (4'), with Polycarbonate housing and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block, including taking down of existing u/s light fitting complete
S&F in repair on wall / ceiling LED batten lighting fixture 20 watts LED 4000K (4'), with Polycarbonate housing and integrated electronic driver and all accessories pre-wired including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block, including taking down of existing u/s light fitting complete
S&F LED crystal glass tube 20 Watt light double side connection ultra bright with very high efficacy suited for installation in existing T8 fitting with G13 lamp holders complete
S&F in repair on wall energy saving, eco friendly LED bulk head fitting 10Watt, IP 65surface mounted with ABS body & polycarbonate diffuser, etc and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete
S&F in repair decorative wall mounting light SS finish fixture with textruded glass difuser suitable for up to 40 watt mini glass lamp, lamp holder, including 9 Watts LED bulb of 6500 K of B22 base cap (Make of Bulb : Havells/Philips/wipro), and all accessories pre-wired including connecting up including taking down of existing u/s light fitting complete
S&F in repair 12 Watt round LED panel recess mounting downlight in 4000K with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 145mm mm dia hight max 35mm recess luminarie complete
S&F in repair ultra bright compact 6 Watt round LED downlighter with high efficiency LED,s idealy suited for low ceiling areas to give glare light IP-54 in 4000K with integraed driver to delivered superior light output and uniformity utilising the latest LED technology, ceiling cutout 95 mm mm dia hight max 83 mm recess luminarie complete
S&F in repair recess mounting 15 Watts innatural white, 1x1 LED flat panel complete envornmental friendly, aesthitically designed for surface mounting which provide soft light and glare free symetrical illumination etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair recess mounting 34/36 Watts in natural white, 2x2 LED flat panel complete with envornmental friendly, ultra modern recess mounting luminaries with high brightness SMD LEDs as light source suitable for ceilings high etc including connecting up with twin core flat flexible copper conductor cable of suitable size with connector block complete
S&F in repair energy saving security light fitting of 45 watts LED environmental friendly pressure die-cast aluminium IP 66 roadway luminaire with high power LED as light source comprising with electronic driver and all accessories pre-wired incl connecting up with PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections and 40 mm bore light grade G. I. tube mounting bracket of 1.5 meter in length, bend to shape at 140 degree in ‘L’ shape and fixed to wall by means of 02 nos. of 40 x 5 mm flat iron clamps, nuts, bolts and washers etc complete
S&F in repair 40 watt LED post top lantern including suitable size medium grade galvanized iron pipe of size 40/50mm up to length of 1.8 Mtrs and necessry plain cement concrete (1:3:6) type CI (using 20mm graded aggregate) as in copings incl necessary form work complete (Make: Crompton greaves Cat part No: LPTO-40/CDL or equivalent in Philips/Wipro/Havells)
Supply and fixing Ventilating fan wall mounted type of 250 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete (Make : Havells/RR fans/Crompton)
Supply and fixing Ventilating fan wall mounted type of 200 mm sweep, 240 volts, AC, 50 Hz capacity, cutting of hole in wall, making of wooden frome, all arrangements for mounting of fan including making good of disturbed surface etc complete (Make : Havells/RR fans/Crompton)
Taking down carefully existing electric meter any type any make after disconnecting the electric connections and refixing the same with and including Polycarbonate thermoplastic meter box with transparent hinged lid with sealing provision, internally embedded gasket of size 217 x 253 x 115 mm suitable to accommodate single phase KWH meter and connecting up including making good the disturbed surfaces complete (Make :- Hensel, Cat Part No. KG 9003 or equivalent)
M&L for sub main wiring with 10 Sqmm nominal cross sectional area, four single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 06 Sqmm nominal cross sectional area, two single core, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 32/40 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
M7L for sub main wiring with 06 Sqmm nominal cross sectional area, two SC, 1100 Volts grade, multi-stranded, PVC insulated, unsheathed, FRLS copper conductor cable with and including continuous earth wire of size 04 Sqmm nominal cross sectional area, and connected to common earth and earth dolly with suitable copper lugs and drawing into and including rigid non-metallic PVC conduit of 25 mm dia, medium grade complete with and including all PVC conduit accessories concealed into wall by cutting of chases in wall and making good to the disturbed surfaces to match the existing including taking out the unserviceable sub main wiring complete
M & L for connecting cable from looping box/ junction box with two single core PVC insulated cable with 1.5 Sqmm (Nominal area) multi stranded copper conductor cable 1100 volts gde incl earth continuity conductor using PVC insulated cable of stranded copper conductor of size 1.5 Sqmm connected to common earth dolly and drawing into rigid PVC conduit incl. making good the disturbed surfaces complete (Note : PVC conduit and its accessories including 2 runs of cable & 1 run of earth continuity conductor cable unsheathed shall be measured and paid as single unit)
Supply & fixing in repair industrial type SPN enclosure with a two pin and earth plug and socket complete with and including MCB, SP, AC, 240 volts of 20 Amps, 'C' curve 10 KA breaking capacity and flush to wall including all cuttings & chases etc in wall and making good to the disturbed surfaces to match the existing complete (Make : Legrand/Havells/Schneider/Hager)
Supply and fixing in repair sheet metal enclosure distribution board, single pole and neutral, AC, 240 volts, 08 way, with 200 Amps rated copper bus bar and metal door with IP - 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete (Make : Legrand/Havells/Schneider/Hager)
S&F in repair sheet metal enclosure distribution board triple pole and neutral (VTPN), AC, 440 volts, 04 ways with 200 Amps rated copper bus bar and metal door with IP 43 & IK 09 protection along with cable end box for above DB and flush to wall including all cutting etc in wall and making good to the disturbed surfaces to match the existing complete all as specified and directed and comprising of the following (Make of MCB DB/MCCB/MCBs :- Legrand/Schneider/L&T/Havells) :- (a) MCCB, 125 Amps, 04 pole, AC, 415 Volts of 16 KA breaking capacity complete - 01 No (b) MCB, SP, AC, 240 volts of 06 to 32 Amps, "C" curve, 10 KA breaking capacity - 12 Nos
S&F in repair MCB, SP, AC, 240 volts of 06 to 32 Amps capacity "C" curve, 10 KA breaking capacity and making connections by using suitable copper lugs complete (Make : Legrand/Havells/Schneider/Hager)
S&F in repair MCB, DP, AC, 240 volts of 32 Amps capacity "C" curve, 10 KA breaking capacity and connections using suitable copper lugs complete (Make : Legrand/Havells/Schneider/Hager)
S&F in repair MCCB, 250 Amps, 04 pole, AC, 415 Volts, 36 KA breaking capacity complete (Make : Legrand/Havells/Schneider/Hager)
S&F in repair MCCB, 125 Amps, 04 pole, AC, 415 Volt, 16 KA breaking capacity complete (Make : Legrand/Havells/Schneider/Hager)
S&F in repair MCCB, 100 Amps, 04 pole, AC, 415 Volt, 16 KA breaking capacity complete (Make : Legrand/Havells/Schneider/Hager)
S&F or passing through pipe, 10 Sqmm, 2 core, 1100 Volts grade, heavy duty, multi-stranded, PVC insulated, aluminium conductor, served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed service cable for service connections from existing LT Panel/Pole to DB/busbar chamber including all cutting / chases etc in walls and making good to the disturbed surfaces to match the existing complete (Make : Havells/Finolex/Polycab)
M&L for earthing complete with galvanised mild steel earth plate electrode 60cmx60cmx6mm thick buried vertically in ground (earth pit not less than 2.25meter deep below ground level) with top edge of the plate not less than 1.5meter below normal ground level steel earth plate connected with GI wire 04mm dia by means of lug, bolts, nuts, check nuts, washers of galvanised iron or steel GI protection pipe 15mm bore light grade all as shown in elect plate No 3 on serial page No 497 of SSR part I - 2009 and connecting to main switch board / Main DB’s including excavation, earth work, salt and charcoal dust mixed and packed 150mm thick around GI earth plate, GI pipe medium grade 20mm nominal bore watering pipe GI sheet funnel wire mesh, concrete pit, RCC cover 40mm thick in PCC 1:2:4 type B1 duly reinforced with MS Bars 6mm dia at the rate of 75mm center to center both way with 12mm dia lifting handle and pit / chamber in PCC 1:3:6 type C1, Angle iron 40mmx40mmx3mm frame for pit cover including testing on completion complete
Taking down of existing u/s highbay lights and Supply and fixing in repair energy saving flood light 150 watts LED 5700K die-cast aluminium IP 66 flood light with high power LEDs as light source, comprising with electronic driver and all accessories complete, arrangements for mounting of fitting i.e. bracket, clamps, nuts, bolts and washers etc all as per site requirement including connecting up with provision of PVC insulated copper conductor cable 1.5 Sqmm, 3 core as required for connections complete (Make : Havells Cat Part No: JETAIRISFLS150WLED757PSYMLTG or equivalent in Wipro Cat No LF2019206057G2/ Philips)
Schdule of Credit - 60777.00
Pall Associates
M/s Prakash Enterprises
Surjit and Sons
M/s Krishna Construction Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .