SE, EUDC-I, NOIDA
33/11 KV SUBSTATION, SECTOR-18 FIRST FLOOR, OPPOSITE SAB MALL, NOIDA
REPLACEMENT OF OLD 11KV VCB AND BUS COUPLER OF 33 KV SUBSTATION SECTOR 122 NOIDA UNDER EUDD 1 NOIDA
2023_PVVNL_783653_1
103/EUDC-I/2022-23/NOIDA (WORKS) (SHORT TERM)
Open Tender
Electrical Works
Item Rate
IN AREA OF EUDSD-IV, NOIDA
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,180
EE, EUDD-I, NOIDA
₹6,100
20 Mar 2023
11 Mar 2023
16 Mar 2023
11 Mar 2023
16 Mar 2023
11 Mar 2023
Amount
FOLLOWING WORK REPLACEMENT OF OLD & DAMAGED EXISTING 11 KV V.C.B. (INSTALLED IN YEAR 2013) WITH NEW 11 KV V.C.B. AT 33/11 KV S/S SECTOR-122 (2X10 MVA=20 MVA) NOIDA IN THE AREA OF EUDSD-IV, NOIDA:-
CARRIAGE OF NEW 11 KV V.C.B. INCOMMER, 800/400/5A, 350 MVA (02 NOS.), 11 KV V.C.B. OUTGOING 400/200/5A (08 NOS.) AND 11 KV BUS COUPLER, 350 MVA (01 NO.) FROM GHAZIABAD/ SHAHIBABAD/NOIDA/JE STORE TO SITE OF WORK WITH SAFE LOADING AND UNLOADING AT BOTH ENDS.
LABOUR CHARGES FOR REPLACEMENT OF 11 KV V.C.B. INCOMMER, 800/400/5A, 350 MVA (02 NOS.), 11 KV V.C.B. OUTGOING 400/200/5A (08 NOS.) AND 11 KV BUS COUPLER, 350 MVA (01 NO.) WITH ALL ACCESSORIES AND ERRECTION OF ABOVE NEW 11 KV V.C.B. INCOMMER, 800/400/5A, 350 MVA (02 NOS.), 11 KV V.C.B. OUTGOING 400/200/5A (08 NOS.) AND 11 KV BUS COUPLER, 350 MVA (01 NO.) WITH REMOVING AND RECONNECTING 11 KV INCOMING AND OUTGOING CABLES, REMOVING AND REFIXING OF EARTHING AND WIRING AS REQUIRED IN VCB, ALL TESTING OF NEW VCB AND BUS COUPLER ETC WITH PROPER SAFETY TO COMPLETE THE WORK ETC IN ALL RESPECT.
CARRIAGE OF DAMAGED 11 KV CGL MAKE V.C.B. (2 I/C + 8 O/C AND 1 BUS COUPLER) PANNEL WITH BREAKER WITH ALL ACCESSORIES FROM SUB-STATION TO ELECTRICITY STORE WITH SAFE LOADING AND UNLOADING AT BOTH ENDS.
PROVIDING AND INSTALLATION OF CHEMICAL EARTHING FOR NEW VCB BRAKER (WITH ALL MATERIAL AND LABOUR) AFTER INSTALLATION RESISTANCE SHOULD BE LESS THAN ONE OHM. AS PER FOLLOWING :- Note :- The all material and labour shall be provided by the contractor with 12 month guarantee for resistance value less than one OHM and should be checked 06 months after proper installation.
Providing of earth elctrode for chemical earthing Pipe in pipe type proper hot deep galvanization dia 80 mm length 3 mtr - 50mm x 6mm terminal connection hole dia 8mm The cavity between the pipe & pipe is filled with conductive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystalline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be galavanized the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested for new 11 KV VCB Braker.
Providing and fixing of GI strip of size 50 mm x 6 mm suitable for new 11 KV VCB Braker.
Providing and fixing of PVC Pit covers for above earthing electrode terminals.
R. P. T. Electrical
Intelligent Smart Grid Pvt.Ltd
NAVITECH ENGINEERS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .