| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.2 LAccepted-AOC | L1 | Accepted-AOC ok | |
| 2 | L2₹8.9 L+₹67,154.40 (8.18%)Rejected-Finance 12 SHRI YANTRA NAGAR SECTOR A INDORE INDORE INDORE INDORE INDORE MADHYA PRADESH 452020 | INDORE | MADHYA PRADESH | 452020 | L2 | Rejected-Finance REJECTED |
Tender Value
₹9.9 L
EMD Value
₹19,740
Closing Date
8 Sept 2021, 5:00 pmClosed
XEN PWD B AND R REWARI
GARHI BOLNI ROAD REWARI
SPECIAL REPAIR OF HEALTH AND WELLNESS CENTRE IN PHC AT AKERA IN REWARI DISTT.
2021_HRY_183991_1
SR OF HWC IN PHC AT AKERA IN REWARI DISTT.
Open Tender
Civil Works - Buildings
Works
60 days
REWARI
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,000
₹19,740
Yes
REWARI
25 Jan 2022
17 Aug 2021
10 Sept 2021
18 Aug 2021
8 Sept 2021
18 Aug 2021
25 Aug 2021
Amount
Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. (HSR 11.59)
Providing and applying two coats white cement based putty of approved sqm 26 10 36 brand and manufacturer, over plastered surface and grinding the surface smooth with sand paper to get en even and smooth finish including cost and carriage of all material , labour charges, scaffolding, sundries etc. complete (HSR 11.58)
Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer (HSR 11.64.1)
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer (HSR 11.67.1)
Painting with silicon & acrylic emulsion based water thinnable sealer of approved brand and manufacture on wet or patchy portion of plastered surfaces: Two coats (HSR 11.72.2)
Applying pink primer or aluminium priming coat on wood work including preparation of surface, Knotting and stopping etc. (HSR 11.77)
Providing & fixing printed Ayushman Bharat Ceramic Tile of approved make laid in any pattern i.c. Ayushman Logo & Beti Bachao, Beti Padhao & Door & window frame flower Bail, Health & Wellness Centre Logo, Signage of Ayshman as specified by the Engineer-in-Charge of work complete in all respect as per PWD specification (NS).
Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore (HSR 22.105.1)
Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 1 o litre capacity - White (HSR 22.39.1)
Providing and fixing white vitreous chinaware wash basin including making all connections but excluding the cost of fittings. Surgeon type wash basin of size 660x460 mm (22.3.6)
Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required 610x460 mm bowl depth 200 mm (HSR 22.10.2.2)
Providing and fixing white vitreous chinaware pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required W.C. pan with ISi marked white solid plastic seat and lid (HSR 22.23.1)
Providing and fixing rectangular high density polyethylene water storage loft tank with cover, conforming to ISi : 12701, colour of opaque white or as approved by Engineer-in-charge. The rate includes making necessary holes for inlet, outlet & over flow pipes. The base support i/c fittings & fixtures for tank shall be paid separately. (HSR 22.182)
Constructing brick masonry inspection Chamber sizes as given below up to 0.60 metre average depth in cement mortar 1 :5 lime concrete with 40 per cent lime mortar 2:3 in foundation cement concrete 1 :2:4 benching 12mm thick cement plaster 1 :2 with a floating coat of 1 mm thick of neat cement R.C.C. 1 :2:4 slab 100 mm thick/cement concrete topping, 50mm thick: with 455mmx455mm / 455mm x610mm inside light duty C.I. inspection chamber cover and frame weight as per 1.5.1. specification painted with 3 coats of black bitumastic superior paint complete as per standard design. (HSR 21.84) Size 450 mm X450 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with C.C. topping (HSR 21.84.1)
Size 600 mm X900 mm inside (with 455 mm x 455 mm cover and frame light duty single seal weighing 20 kg with R.C.C. slab) (HSR 21.84.3)
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. Flexible pipe 32 mm dia (HSR 22.14.2.1)
Providing and fixing brass stop cock of approved quality: 15 mm nominal bor (HSR 22.97.1)
Providing and fixing 8 mm dia C.P. I S.S. Jet with flexible tube up to 1 metre long with S.S. triangular plate to European type W.C. of quality and make as approved by Engineer - in - charge. (HSR 22.38)
Providing and fixing on wall face Unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diamete (HSR 9.57.2)
Labour for laying, jointing, fixing and testing G.1./P.V.C./W.I. pipelines and special tees, bends, sockets, elbow etc. inside building and testing etc. complete including cutting threading Including cost of specials (HSR 20.20) 15 mm internal diametre of pipeline (HSR 20.20.2.1)
20 mm internal diametre of pipeline (HSR 20.20.2.2)
M/s Shree Laxmi Trading Company
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .