Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.7 CrAccepted-AOC OFFICE NO 304 305 3RD FLOOR PLOT NO 1 USHA CHAMBERS L S C NEW RAJDHANI ENCLAVE DELHI 110092 | DELHI | EAST DELHI | DELHI | 110092 | L1 | Accepted-AOC Being lowest and reasonable. | |
| 2 | L2₹13.1 Cr+₹26.0 L (2.03%)Rejected-Finance 154 SECTOR 13 HISAR 125005 HARYANA | HISAR | HISAR | HARYANA | 125005 | L2 | Rejected-Finance Being other than lowest | |
| 3 | Rejected-Technical 2A IHDP BUSINESS PARK SECTOR 127 NOIDA UTTAR PRADESH 201304 | NOIDA | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201304 | - | Rejected-Technical Requisite documents as per NIT for un enlisted firm not submitted by the bidder. Not approved | |
| 4 | Rejected-Technical 10 SHANTI VIHAR RUDRAPUR UDHAM SINGH NAGAR UTTARAKHAND 263153 | UDAM SINGH NAGAR | UTTARAKHAND | 263153 | - | Rejected-Technical Not approved being two class below eligible class |
Tender Value
Refer Docs
EMD Value
₹10.0 L
Closing Date
23 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CE (AF) PRAYAGRAJ
CE (AF) PRAYAGRAJ
PROVISION OF URC AND REGIMENTAL SHOPS AT NORTH CAMP AT AF STN BAMRAULI
2024_MES_679836_1
958822/E8
Open Tender
Civil Works
Lump-sum
2235 days
Bamrauli
Please refer Tender documents.
9 documents required · 9 mandatory
₹3,000
GE (AF) BAMRAULI
₹10.0 L
Yes
20 Jan 2025
16 Oct 2024
27 Dec 2024
16 Oct 2024
23 Dec 2024
9 Dec 2024
Amount
SCHEDULE A PART I (BUILDING WORKS)
Design, fabrication, erection & construction of three storey building (G+2) of URC and Regimental shop along with entrance passage of approximate height 15 M with Light Gauge steel frame (LGSF) structure combined with PEB steel structure complete all as specified as shown in drawings. Notes: - (a) Building shall be constructed with LGSF combined with steel structure technology designed as per approved design parameters. (b) Building shall be constructed as a composite building wherever shown in the drgs or as directed by employer and its representative. (c) Lifts well is also included in the building as per drawing however Lifts will be provided under respective item of Schedule of BOQ.
Sch A Part II (INTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for Internal Water Supply as listed in Sch ‘A’ Part II.
Sch A Part III (INTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for Internal Electrifications as listed in Sch ‘A’ Part III .
Sch A Part IV (EXTERNAL WATER SUPPLY)
Lump sum price worked out by the contractor for External Water Supply as listed in Sch ‘A’ Part IV .
Sch A Part V (EXTERNAL ELECTRIFICATIONS)
Lump sum price worked out by the contractor for External Electrifications as listed in Sch ‘A’ Part V.
Sch A Part VI (SEWAGE DISPOSAL)
Lump sum price worked out by the contractor for Sewage Disposal as listed in Sch ‘A’ Part VI.
Sch A Part VII (AREA DRAINAGE)
Lump sum price worked out by the contractor for Area Drainage as listed in Sch ‘A’ Part VII
Sch A Part VIII (ROAD/PATH AND CULVERT)
Lump sum price worked out by the contractor for ROAD/PATH AND CULVERT as listed in Sch ‘A’ Part VIII
Sch A Part IX (DEMOLITION AND DISMANTLING)
Lump sum price worked out by the contractor for Demolition and Dismantling as listed in Sch ‘A’ Part IX
Sch A Part X (SITE CLEARANCE & DEVELOPMENT)
Lump sum price worked out by the contractor for Site Clearance & Development as listed in Sch ‘A’ Part X
Sch A Part XI (Lift and Miscellaneous Items of B/R and E/M)
Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairing of CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 150 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed. Notes:- (i) Excavation earth works shall be measured and paid separately. (ii) Joints CI/DI specials shall be measured and paid separately. (iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate.
Supply, laying, jointing and testing of ductile iron pressure pipe with socket & spigot ends having ISI stamping marking confirming to IS: 8329/2000 in standard length of 5.50-6.00 meter of classification K-7 including rubber tyton jointing material suitable for push on rubber tyton (gasket D-jointing) with cement mortar lining in the pipes having 100 mm bore, including aligning the pipes inside trench as per IS: 12288/1987 and testing the joints with required water pressure complete all as specified & directed. Notes:- (i) Excavation earth works shall be measured and paid separately. (ii) Joints CI/DI specials shall be measured and paid separately. (iii) Joints Material rubber tyton joint and Lead joint etc included in the quoted rate.
M&L for upto 150 mm bore ductile iron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot,caps and plugs complete all as specified and directed.
Dismantling old broken / damaged valve pit chamber and construct valve pit chamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for disconnecting the electrical supply of LT panel ,dismantling and shifting of LT panel of any size by taking out from PCC foundation complete and shifting to other location as per direction fixing the panel in true vertical position including excavation and earth work, PCC 1:3:6 type C1(using 20mm graded stone aggregate) complete all as directed by Engineer-in-Charge.Note: 1. Necessary electric shutdown to the panel will be given before the work.
Supply , installations , testing & commissioning in replacement of 11 KV of rating 630 Amp RMU unit outdoor type (IP-54) protection duly painted(Paint shade in painted Alu Zn/RAL 7032 on sheet steel for door and covers), VCB type I RMU( RING Main unit) Four way comprising of Three numbers insulated load break switch as outgoing and one number Vacuum Circuit Breaker as incoming inside . RMU should be provided with Copper Bus bar , one number fault passage indicator with each incoming and outgoing mechanism for interlocking arrangements for powered relay complete with all accessories as under.(a) RMU type installation Outdoor Extensible type, arc proof as per IEC : 62271-200 for design Manufacturing and testing . The RMU must have the following features/specification:- INCOMER :- VCB should have following specification :- (i) Rated Voltage upto -12KV (ii) Rated power frequency withstand voltage -28KV(iii) Rated lighting impulse withstand voltage –should be minimum 125KVP (iv) Rate d current for ring main feeder -630A (v) Rated current for VCB feeder -630A (vi) Rated short-time current-21 KA/3 Sec(vii) Rate Short making current -50KA (viii) Ambient temperature (-1 degree Celsius to +45degree Celsius), (ix) Degree of protection against accidental contact and ingress of foreign objects must be assured as under:- (aa) Main electric circuits : IP-67(ab) Fuse compartment IP3X (ac) Operating mechanism –IPXC ,(ad) Cable connection compartment-IPXC with site replaceable cable bushing . (xi) Each vacuum circuit Breaker includes :
OUTGOING :-(i) Each load break Switches includes:- (a) three position switches with position ON-OFF -EARTH (b) Manual operated spring mechanism ON-OFF-EARTH (c) Mechanical indicators for position ON-OFF-EARTH , (d) Mimic diagram at the front facia of RMU , (e) Capacitive Voltage indicator , (f) Padlocking facility , (g) Fault passage indicator for Earth Fault .(ii) Right angled Cable boots -3x sets (iii)The quoted rate shall be demmed to include cost of PCC foundation and PCC plateform of suitable size as per OEM recommendation 100 mm thick PCC 1:2:4 type B1 (20 mm graded stone aggregate) over 100 mm thick hard core of 63 mm complete. Make of RMU: ABB/SCHNEIDER/SIEMENS or as specified in particular specification.
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 1.4 time of current rating incoming capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for I/C 400 Amps and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, Adjustable type, 350 Amps with breaking capacity 36 KA -01 Nos (b) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos (c) 3 phase bulk meter incl ct and pt and current range(10-60A) in 1phase Outgoing: - (a) MCCB 4 Pole, 415 V, 200 Amps with breaking capacity 36 KA -01 Nos (b) MCCB 4 Pole, 415 V,Adjustable type ,100 Amps with breaking capacity 16 KA -02 Nos (c) MCB 63 Amp 230V with breaking capacity of 16 KA - 02 Nos
Supply, installation, commissioning and testing LT panel board, conforming to CPRI Specifications, 415V, 50 Hz, AC supply , three phase and neutral, outdoor (Kiosk) type with apron, of suitable size, factory made, fabricated with 3.15mm thick mild steel sheet (Outer Body), ISMC-75 base channels, duly powder caoted internally and externally painted with seven tank process with approved shade, rubber gasketted, hinged fornt and back openable doors with proper locking arragnement for dust and vermin proof, internal wiring with suitable size of PVC FRLS copper conductor cable complete including suitable size lugs, glands etc. incl one no. brass pad lock, 50mm size, 4 levers and making connections, incl earth work and PCC foundation complete comprising of the followings and specified: - (i) Aluminium bus bar 1.4 type of incomming Amps current rating capacity comprising of 4 Aluminium strips of appropriate size provided with heat shrinkable sleeve not less than one mm thick and epoxy insulators 1100 volts rating 8 nos. (ii) Cable alley for I/C 400 Amps and all outgoing feeders Incoming: - (a) MCCB 4 Pole, 415 V, Adjustable type, 63 Amps with breaking capacity 16 KA -01 Nos (b) Meter module digital volt and amp meter incl CTs of appropriate size with accessories -01 Nos Outgoing: - (a) MCCB 4 Pole, 415 V, 40 Amps with breaking capacity 16 KA -02 Nos (b) change over switch 63A -01 Nos
S&F for CP Jet spray with 1 Mtr long CP flexible tube complete all as specified and directed.
Supply & Fixing angle cock two way of 15 mm bore dia chromium plated fancy type screwed both ends for iron pipes or for brass ferrule complete all as specified & directed
Supply & Fixing CP urinal spreader of 15mm bore fancy type screwed down for iron pipe or for brass ferrule complete all as specified & directed
Designing, topographic survey, getting the design vetted from any one of the approved agencies, manufacturing, Design, supply, installation, testing and commissioning of Grid connected roof top type Solar Power Plant of 50 KWp Capacity, system panels made with Multi Crystalline Silicon Modules and mounted on Galvanised steel Structure and installed on roof top of RCC framed structure complete all as per IS code and as specified in Particular Specifications and as directed. The rate quoted is deemed to be inclusive of the following :- [a] Grid Interactive Solar Inventor of suitable capacity. [b] AC Distribution board with multi data meter. [c] Temperature and irradiance sensors and contactors, terminals etc. [d] Cables of suitable size complete with terminations up to users LT Panel board end laid in a Engineering practice [e] Suitable No. of Chemical Earthing including GI Earth Strip. [f] RCC Foundation and Structures for its module mounting as per the design approved. [g] Packing, Forwarding and transportation of all equipment. [h] SCADA System as specified in IS-14286. [j] Isolation transformer as specified in IS-14286. [k] Fire extinguisher, Sand, Bucket as specified in IS-14286. (l) Lightning arrestor as specified in IS-14286. (m) Pyranometer , Temperature sensor, anemometer and wind vane i.e. total weather monitoring station (WMS) as specified in IS-14286. (n) metering arrangement as specified in IS-14286. (o) NOC (no objection certificate) from safety department for ongrid system. (p) The rate quoted is deemed to be inclusive of detailed engineering design including feasibility survey for solar power plant using “PV SYS” and “PV SOL” or equivalent software, topographic survey, foundation design etc. and getting the design vetted from “ MNNIT Allahabad/IITs/NITs including Solar Energy Centre/MNRE Approved test centre”, manufacturing, supplying, erecting, installing, testing and commissioning of grid connected roof top type Solar PV Plant of 50 KWp capacity, being installed on Building as per feasibility study at conditions prevalent complete comprising of sub-components, sub-systems and meeting the specifications as given hereinafter and in particular specifications. Note :- (i) All electrical cable /control cable should be properly laid as per Engineering practice ie. on cable tray (cablo foil). (ii) Unit quoted rate shall be deemed to include the cost of cable tray. (iii) The contractor shall carried out structure stability from any IITs/NITs / MNNIT Allahabad before start the work for roof and fixation of where solar module to be mounted on roof top of the URC building being constructed under this contract under Sch A Part-I, within one month from date of completion of building work.
Design supply, install testing & commissioning passengers lift for 13 passenger (884 Kg). speed 1.5 metre/sec, lift with single speed motor 415 volts, 3 phase, AC 50 Hz supply conforming to IS-14665, suitable to serve G+ 03 upper floors with AC Variable Voltage & Variable Frequency drive (V V V F drive) complete with all standard accessories, simplex automatic & manual dual controlled operation with/without attendant, centre opening doors with door drive (electric motor driven mechanism), sliding stainless steel doors, automatic rescue device (ARD) system, 3D infra red sensor in full height of door & built in announcing system without hand set (04 Nos, one each in car, Machine room & near Ground floor landing door). complete all as specified and directed by Engineer-in-Charge. Note:- Overall quoted rates including of all consumables and minor parts Annual maintenance contract (AMC) during the defect liability period of two year. Necessary MoU shall be submitted by the contractor duly signed by the OEM of AMC and further maintenance.
Supply, installation, testing and commissioning of Smart meter ( RF / Cellular / Hybrid (RF+Cellular)) Three Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A having valid BIS licence of IS-16444-2015 (Reaffirmed 2020) and relevant IEC standards with default and on demand display, billing data generation facility, with prepaid and postpaid facility, anti-tamper features, Microprocessor and LED/LCD based circuitry, including integration and maintaining the Advance Metering infrastructure (AMI) of smart meters of different makes having valid BIS certification mark with specific CM/L number (not more than 33% of particular one make) to ensure interchangeability at later date using communication technology including GPRS/RF/Hybrid (RF + cellular) or any other advanced technology as per CEA/TRAI regulation in order to achieve overall economy in operation and maintenance.
Supply, installation, testing and commissioning of Smart meter ( RF / Cellular / Hybrid (RF+Cellular)) Single Phase AC Meter Tamper Proof, Static Meter of Class 1.0, 415 V, 50 Hz, 10 A-60 A having valid BIS licence of IS-16444-2015 (Reaffirmed 2020) and relevant IEC standards with default and on demand display, billing data generation facility, with prepaid and postpaid facility, anti-tamper features, Microprocessor and LED/LCD based circuitry, including integration and maintaining the Advance Metering infrastructure (AMI) of smart meters of different makes having valid BIS certification mark with specific CM/L number (not more than 33% of particular one make) to ensure interchangeability at later date using communication technology including GPRS/RF/Hybrid (RF + cellular) or any other advanced technology as per CEA/TRAI regulation in order to achieve overall economy in operation and maintenance.
Supply and fixing factory made epoxy powder coated distribution board MCCB VTPN 8 way double door 430 volt, IP-43, suitable for 125 Amps MCCB including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed.
Supply and fixing 4 Module Gang box including Modular socket outlet 16 Amps for AC, 240 Volts flush type white finish including plug top 20 Amps with modular piano type switch 20 Amps and LED indicator (RED) incl concealed point wiring on wall and surface wiring on ceiling/roof with necessary arrangements with 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings and Modular white cover plate with frame 4 module to accommodate all the accessories complete with internal connections, fixed with chromium plated screws and washers for switches and sockets, including 4 Sqmm single core 1100 Volts grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduit and making good disturbed surfaces by cement mortar (1:3) and to match with the existing surface/colour by using existing oil bound distemper/white wash complete all as specified and as directed.
Supply and fixing factory made epoxy powder coated distribution board V-TPN 4 ways double door including with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 300 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
Supply and fixing factory made epoxy powder coated distribution board SPN 08 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
supply and fix connecting and testing LED street light 35 watt 6000k/3000k new generation energy saving and environmental friendly long life led street light made up of pressure die cast aluminium housing with high efficient led as lighting source and PC cover having top opening seperate driver compartment with IP66 protection and impact resistance of IK07 roadway luminaries with high power LED as light source and electronic driver complete with connection and accessories for fixing with with including grade 40mm dia GI pipe as bracket in appropriate length complete including taking down old light fitting
Supply & fixinginh wall mounted angular electric chimney black colour of suction power not less than 1220 Cum / Hr, Al Cassete with stainless steel outer layer, touch control panel, 3 Speed motor with 250 watt with decorative smart Cookerhood SS and Glass, energy efficient LED light with digital display, including ducting not less than 10 ft / as and with self cleaning fescility complete all as per site requirement and as specified and directed by GE. Make:- Elica, Model Kitty plus or equivalent in Kaff/ Hindware.
Supply and fixing factory made epoxy powder coated distribution board MCB DB VTPN 8 way double door 430 volt, IP-43, suitable for 63 Amps TPN including 200 Amps copper bus bar ,neutral bar complete fixed properly and to connect their incoming/outgoing electric connections by means of suitable size of lugs/thimbles and to provide required sizes of flexible conduit at any open surfaces near DB's of cables/wires complete all as specified and directed.
Sch A Part XII (Manning and operation of lifts during Defect Liability period of two years and three years after defect liability period)
Manning and operation of both the lifts installed here in before for two years during defect liability period and three years after defect liability period by employing one semiskilled category industrial person in each lift wearing uniform in one shift per day of 08 hrs including Sunday and holiday complete all as specified and directed for following time period:- Note :- 1. The contractor shall pay minimum fair wages to the employees fixed by the Govt. of UP or Central Govt. whichever on higher side through bank account. The contractor shall produce the proof of payment to the employees such as statement of bank account, EPF payment as per EPF or UP act, ESI payment duly signed by all the tradesman/Engineer-In-Charge at the time of RAR/Final Bill. 2. Penalty Clause:- If the Lift found absent from duty the penalty for this lapse shall be final and binding as under:- Double the rate of minimum wages published by the GOI during the absent period.
For first 11 months
For second 11 Months
For Third 11 Months
For fourth 11 Months
For Fifth 11 Months
For Last 05 Months
Sch A Part XIII (Annual Maintenance of lifts after defect liability period)
M&L for annual maintenance of both the Lifts by performing all fortnightly, monthly, bi-monthly, half yearly and yearly checks and tests and service as per specified intervals including all repair and replacement of unserviceable spare parts for making the Lifts serviceable after the completion of defects liability period (DLP) through OEM complete all as specified and directed for the followings time period:-
For first year after Defect liability period.
For second year after Defect liability period.
For third year after Defect liability period.
Note for item No. 13.01 to 13.04:- (a) The contractor shall enter into MoU with the OEMs for the provision of the lift and further maintenance. The MoU for the post warranty/post defect liability period between the contractor and OEM shall be submitted by the contractor. (b) The rates quoted is inclusive of all consumable and minor parts but excluding of spare parts as listed in PC Sum (Schedule A Part-XIV). If there is any requirement of major spare parts, same will be measured and paid seperately under PC Sum Schedule.
Sch A Part XIV (PRIME COST SUM)
Lump sum price worked out by the contractor for Prime Cost Sum as listed in as listed in Sch ‘A’ Part XIV. Note :- The amount to be quoted by the Tenderer in BOQ against the inserted price by the department shall be restricted to Maximum 15% over and above the prime cost sum, accordingly the tenderer shall quote the amount.
Deduct Schedule of Credit of Rs. 5,63,117.40 as brought out from Credit Schedule Sr Page No. ___ of tender
NITYA NAND AND SONS CONTRACTORS PVT LTD (BID ID -3190422)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
BOQ.xls
BOQ • 0.96 MB
Tenderdocument.rar
Tender Documents • 7.99 MB
Tenderdocument_2.rar
Tender Documents • 17.43 MB
Tenderdocument_3.rar
Tender Documents • 17.04 MB
Tenderdocument_4.rar
Tender Documents • 6.30 MB
Tenderdocument.pdf
Tender Documents • 2.11 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .