Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Rank | Status |
|---|---|---|---|
| 1 | L1Accepted-AOC | L1 | Accepted-AOC L1 |
| 2 | L1Accepted-AOC 03 GOVIND PURAM EIDGHAH ROAD BIJNOR BIJNOR UTTAR PRADESH 246701 | BIJNOR | UTTAR PRADESH | 246701 | L1 | Accepted-AOC L1 |
| 3 | L1Accepted-AOC MADHYA PRADESH PRESERVED | DAMOH | MADHYA PRADESH | 470664 | L1 | Accepted-AOC L1 |
| 4 | Not Admitted-Finance 2ND FLOOR 45 A MAA SHARDA NAGAR KABIT KHEDI INDORE NEAR BHRAT PUBLIC SCHOOL MR 10 SQUARE INDORE MADHYA PRADESH 452010 | INDORE | MADHYA PRADESH | 452010 | - | Not Admitted-Finance Not qualified for AOC |
| Sl No | Description | Qty | Unit | Pacific Marketing L1 | ASHVI IRRIGATION L3 | Deep Enterprises L2 |
|---|---|---|---|---|---|---|
| 1.01Construction work for Polyhouses, Mist chambers, Greenhouses, High-tech irrigation, Ground-bed sprinkler systems, Solar lighting systems and Poly-propagators (inclusive of materials). | ||||||
| 1.02 | Polyhouse Technical Specifications :-
1. Size & Shape
• Type: Arch-shaped polyhouse
• Center Height: 15 feet
• Side Height: 11 feet
2. Base / Foundation (Description)
1.Ground Preparation
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension per Square feet
2. Pole Foundation
• Galvanized Iron (GI) pipes must be fixed in the ground using cement concrete.
• Hole size for each pole: 0.45 m × 0.45 m × 1.0 m deep.
• Distance between two poles should not be more than 3 meters.
3. Side Brick Wall
• A small brick wall of 20 cm height and 20 cm width should be built around the entire structure.
4. Center Path
• In the middle of the polyhouse, a path of interlocking pavement blocks should be made.
• Path size: 17.88 m × 1.50 m.
5. Plant Beds
• Beds should be built on both sides of the path.
• Beds should be made using brickwork and plastered.
• Beds should be placed at 90° (right angle) to the path.
• Each bed:
• Inner width: 1 meter
• Side wall height: 20 cm
• Distance between two beds: 35 cm (including sidewalls).
• The gap between two bed walls should be filled with M-20 cement concrete, and plaster should be done on all brickwork.
3. Structure (Simple Description)
1. Material
• Entire structure should be made from Galvanized Iron (GI) steel, hot-dip galvanized.
• Structure must follow IS 875 standard and withstand 120 km/h wind speed.
2. Poles and Pipes
• Foundation GI pipes : 3.00 inch x 3.00 inch square pipes
• Main column GI pipes: 2.50 inch x 2.50 inch square pipes
• Arch base GI pipes: 1.50 inch x 1.50 inch square pipes
• Purlin: 1.50 inch x 1.50 inch square pipes
• Remaining structure pipes: 1.50 inch x 1.50 inch square pipes
• Thickness of all GI pipes should be 2mm.
• All Column GI pipes should be fixed into 3.00 inch x 3.00 inch foundation GI pipes which in turn be fixed 1.00 meter deep into cement concrete in the ground.
• There should be two purlin below the arch base.
3. Door
• 2 Aluminium frame doors with 6mm polycarbonate sheet. One door should be at front and the other at the back
4. Distance Between Columns
• Maximum 3 meters.
4. Cladding (Covering Materials)
1. Poly Film
• 200-micron UV-stabilized film
• More than 80% light transmission
• From a major/reputed brand
2. Insect Net
• 40-mesh insect net on both long sides
• Net height: from 1 meter above ground up to 2.5 meters
• Poly film in net area should be foldable to allow airflow.
3. Shade Net
• Shade-net curtains should be fixed inside the polyhouse to cover plant beds when needed.
5. Overhead Irrigation / Fogger System
• Hanging foggers with lateral pipes, supporting wire, and MS support frame.
• Fogger parts must be from a major/reputed brand.
• 1 HP pump of major brand with one year warranty should be provided .
• 1000-liter water tank for fogger supply.
6. Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 10 feet width outside it.
7. Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or the poly film.
8. Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
9. 12mm Electricity service cable of 50 meter should be fixed from supply line to polyhouse.
10. All the electric equipment should be placed in a well insulated cabin. | 1 | प्रति वर्गफीट | - | 184 ₹217.12 | 196.45 ₹196.45 Lowest |
| 1.03 | Mist Chamber Technical Specification :-
Shape : Arch shape
Center Height : 4 meter
Sidewall Height : 1 meter
Height of Polycarbonate Sheet Above Walls : 1.5 meter
Evaporative Cooling System
1.5 meter tall with lengthwise evaporative Cellulose complete set cooling pad with all necessary framing material of aluminium required supporting distribution & returning piping, gutters down spout end caps and drip pan, plumbing kit, pump capacity as per requirement. Drilled PVC piping cap, pad retainer, all suspension hardware, metal flashing as required to seal pad to vent opening, 4” thick evaporative.
Cooling pad material :
Pad construction material, aluminium profiles, tray sides, water distribution tray, cooling media 100mm thick
Water storage tank capacity : 2000 liter (Major Brand)
40 Mesh Nylon for extra protection from dust, fitted behind pad
1HP water pump of major brand with one year warranty should be used in cooling system
Civil Works:
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension 10 meter x 10 meter x 0.80 meter
Structure will be raised on RCC with columns and beams as per requirement, foundation wall of width 20cm for all sides of mist chamber.
Wall around the structure should be of at least 1 meter height above ground and thickness of the wall shoud be of 20cm.
Filling of base with hard murrum and making it compact such that it remains stable. RCC Floor above murrum base of 5cm thickness.
Three platforms should be raised above floor for germination beds with following specifications:
• Inner Dimension of germination beds–
▪ Middle bed 7x1x0.20 meter (length x width x depth)
▪ Beds on sides 8x1x0.20 meter (length x width x depth)
• Base of germination beds should be of RCC.
• Germination beds should be raised on RCC Columns of required numbers.
• Height of Platforms not be less than 1 meter
• Installation of tiles should be done on the inner and outer walls and top walls of the germination platforms and also on the columns on which ths germination beds are raised.
• All walls and columns shoul be plastered with 12mm thickness cement plaster.
Structure Frame :
• All galvanized iron should be used design as per IS875 standards to withstand wind speed 120 km/h. Complete pre machined structure and cladding with polycarbonate sheet 6 mm thick multiwall UV stabilized material:
• All structures, rafters, purlins, trusses should be hot galvanized without welding. All main parts should be hot galvanized.
• Galvanised pipes of the structure should be fixed into the RCC columns of the structure with the help of fasteners and RCC. GI Columns pipes should be of thickness 2x2 inch. Base of the arch above column pipes should be made with 2x2 inch GI pipes.
• The galvanized iron used in frame should be of major brand. Steel used in RCC should be of major brand .
• Door should be fixed for entry in mist chamber Made with aluminium frame and fixed with 6mm polycarbonate sheet.
Fixing of UV stabilized Polycarbonate sheet:
Polycarbonate sheet of 6 mm thickness should be fixed on GI pipes with heavy duty aluminium profile on both sides.
Fogging System :
• Hanging fogging system with heavy duty water pump with fourway fogger(22lph), sand filter, screen filter and pressure meter to raise Relative Humidity upto 90%.
• Water pump for fogging system should be 3HP and of major brand with one year warranty and with a provision of AMC (Annual Maintanance Cover)
• All fogging system parts should be of major brand
• Screen filter and sand filter should be of major brand
Climate Control System :
• Two heavy duty exhaust fans of 54 inch outer diameter should be fixed
• Electronic climate control system which can monitor and control temperature and humidity. It should maintain chamber climate by contolling chamber equipments like cooling fan, foggers etc. It should have manual and automatic working options. One should be able to set required humidity and temperature with help of control pannel fitted with LCD screen.
• Electronic climate control system should control two exhaust fans, fogging system and cooling system with input from temperature and humidity sensor.
Permanent Brick Structure for housing all Electronic and Electrical equipments should be made attached outside the structure.
Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 5 feet width outside it.
Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or the polycarbonate sheet.
12mm Electricity service cable of 20 meter should be fixed from supply line to polyhouse. | 1 | प्रति वर्गमीटर | - | 12,006 ₹14,167.08 Lowest | 14,355 ₹14,355 |
| 1.04 | Overhead Sprinkler Irrigation System :-
Scope of Work and Materials Required
The quotation must cover the complete supply, installation, testing and commissioning of the Overhead Sprinkler Irrigation System, including all required materials, fittings, accessories, labour and installation charges, as per the following specifications:
1. Overhead Sprinkler Irrigation Setup:
- Bed Dimensions: 10 meters (length) × 0.15 meters (width) × 1.20 meters (height), as per the existing layout.
- Sprinkler System: Supply and installation of overhead sprinklers suitable for uniform irrigation of nursery beds.
- Sprinkler Heads: Heavy-duty, corrosion-resistant impact or rotary sprinkler heads with suitable nozzles, providing uniform water distribution.
- Sprinkler Spacing: Sprinklers shall be installed at suitable spacing, generally 3–4 meters apart, subject to the manufacturer's specifications, spray radius and approved irrigation layout.
- Risers and Supports: Supply and installation of suitable PVC/HDPE riser pipes, clamps, brackets and supports to position sprinkler heads above the nursery beds and ensure uniform water coverage.
- Lateral Pipes: Supply and installation of suitable-size PVC/HDPE lateral pipes connecting the sprinklers to the main supply line.
- Fittings and Accessories: All required tees, elbows, reducers, sockets, unions, end caps, clamps, connectors and other accessories for a complete operational system.
- Control Valves: Provision of valves for individual sections/zones to facilitate sector-wise irrigation and independent operation.
2. Main Water Supply Line:
- Main Pipe: 75 mm diameter PVC pipe of suitable pressure rating, as approved by the competent authority.
- Total Length: 300 meters of main supply piping.
- Installation: Complete laying, jointing, alignment, trenching wherever required, backfilling, testing and commissioning of the main pipeline.
- Branch Connections: Necessary branch pipelines, fittings and control valves for supplying water to the sprinkler zones.
3. Water Source and Storage:
- Water Tank: Supply and installation of one 2,000-litre capacity water storage tank, including necessary inlet, outlet, overflow and drain connections.
- Tank Foundation: Suitable base/support for safe installation of the tank, wherever required.
- Suction Arrangement: Necessary suction piping, foot valve, strainer and associated fittings for reliable pump operation.
4. Pumping System:
- Water Pump: Supply and installation of one 3 HP electric motor-pump set of a reputed brand, with a minimum one-year manufacturer's warranty.
- Pump Selection: The pump shall be suitable for the required discharge and operating pressure of the sprinkler system, as established by hydraulic calculations.
- Accessories: Necessary starter/control panel, electrical cables, earthing, protection devices, pressure gauge, non-return valve and other accessories required for safe and efficient operation.
- Electrical Safety: All electrical equipment shall be installed in a properly insulated and weather-protected enclosure.
5. Filtration System:
- Screen Filter: Supply and installation of a screen filter of suitable capacity to prevent nozzle blockage.
- Sand/Media Filter: Provision of a sand/media filter wherever required, depending on the quality and source of irrigation water.
- Filter Accessories: Necessary valves, connectors, pressure gauges and cleaning/backwashing arrangements, as applicable.
6. Fertilizer Application System:
- Fertigation Unit: Supply and installation of a Venturi injector system suitable for fertilizer application through the sprinkler irrigation network.
- Accessories: Fertilizer mixing tank, connecting pipes, control valves and other necessary fittings.
- The system shall permit controlled fertilizer application without compromising sprinkler performance.
7. Testing and Commissioning:
- Complete installation, flushing and pressure testing of all pipelines.
- Testing of sprinkler discharge, spray radius, pressure and uniformity of water distribution.
- Demonstration of sector-wise operation and fertilizer injection.
- Rectification of leakage, defective joints and installation-related defects before handing over the system.
- Supply of operating instructions and warranty documents.
8. General Conditions:
- The quoted rate shall include all materials, labour, transportation, installation, fittings, testing and commissioning charges.
- All materials shall be new, durable and of approved quality.
- The contractor shall submit the sprinkler layout, technical specifications, pump performance details and material list for approval before installation.
- The complete system shall be handed over in fully operational condition.
- Any additional accessories required for satisfactory functioning of the system shall be included in the quotation. | 1 | प्रति बेड | 1,674 ₹1,975.32 Lowest | 2,486 ₹2,933.48 | 2,633 ₹2,633 |
| 1.05 | Green Shadenet House Technical Specification :-
Size & Shape
• Shape: Even Span Type
• Center Height: 12 feet
• Side Height: 10 feet
2. Base / Foundation (Description)
1. Ground Preparation:
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension per Square feet
2. Pole Foundation: Galvanized Iron (GI) pipes must be fixed in the ground using cement concrete. Hole size for each pole: 0.45 m x 0.45 m x 0.50 m deep. Distance between two poles should not be more than 3 meters.
3. Side Brick Wall: A small brick wall of 20 cm height and 20 cm width should be built around the entire structure. This wall should also be plastered.
4. Center Path: In the middle of the polyhouse, a path of interlocking pavement blocks should be made. Path size: 18.288 m x 1.50 m.
5. Plant Beds:
• Beds should be built on both sides of the path.
• Beds should be made using brickwork and plastered.
• Beds should be placed at 90° (right angle) to the path.
• Each bed: Inner width: 1 meter, Side wall height: 20 cm,
• Distance between two beds: 35 cm (including sidewalls).
• The gap between two bed walls should be filled with M-20 cement concrete, and plaster should be done on all brickwork.
3. Structure (Simple Description)
1. Material: Entire structure should be made from Galvanized Iron (GI) steel, hot-dip galvanized. Structure must follow IS875 standard and withstand 120 km/h wind speed.
2. Poles and Pipes:
• Main column GI pipes: 3 inch x 3 inch square pipes
• Remaining structure pipes: 1.5 inch x 1.5 inch square pipes
3. Door: 2 Aluminium frame doors with 6mm green coloured polycarbonate
sheet. One door should be at front and the other at the
back.
4. Distance Between Main Columns: Maximum 3 meters.
Cladding (Covering Materials)
1.green net UV-stabilized shade net with 75% light transmission. From a major/reputed brand.
Industrial Cladding & Anchoring: Structured requirements for the UV-stabilized green shade net utilizing professional aluminum profiles and zig-zag structural locking springs to prevent flapping or wind damage.
4 . Overhead Irrigation / Fogger System
• Hanging 4 way sprinkler system with lateral pipes, supporting wire, and MS support frame.
• sprinkler parts must be from a major/reputed brand.
• 3 HP pump with starter, both of major brand with one year warranty should be provided.
• 2000-liter water tank for sprinkler supply
• Main supply pipe for sprinkler lateral pipes should be 63 mm UPVC pipes
• Sprinkler’s lateral pipes should be fitted parallel to the center path at the interval of 1 meter.
• Sprinklers should be fitted at the interval of 1 meter.
• Sand and Screen filter should be fitted for sprinkler supply. The aforementioned filters should be of major brand and with one year warranty.
• Control valves should be fitted where required or as directed at site.
Headworks: Explicit technical layout mapping your 63mm UPVC mains across a 60-meter running stretch feeding 20 overhead micro-sprinkler assemblies with comprehensive filtration, control valves, and system pressure gauges.
Permanent Brick Structure for housing all Electronic and Electrical equipments should be made attached outside the structure.
Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 5 feet width outside it.
Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or shadenet.
12mm Electricity service cable of 20 meter should be fixed from supply line to polyhouse. | 1 | प्रति वर्गफीट | - | 71 ₹83.78 Lowest | 131.3 ₹131.3 |
| 1.06 | Solar street light system specification :-
Solar street light with 18 watt LED lamp( Major Brand like Havells/philips), 40Ah battery(Major Brand like Luminous/Amaron) and 100 watt solar panel(Major/Reputed Brand, Example-Tata/Adani) with 15 feet GI pole arm, brackets etc. Complete fitting with concrete foundation. Warranty should be 25 years for panel and 5 years for all remaining system. | 1 | प्रति इकाई | - | 22,700 ₹26,786 | 24,750 ₹24,750 Lowest |
| 1.07 | High Tech Irrigation System :-
High tech irrigation system supply and installation for hanging irrigation sprinkler system, MS pipe main vertical column 1.5 inch x 1.5 inch square pipe heavy duty two pole distance 3 meter and horizontal purlin 1.25x1.25 inch heavy duty arrangement of 16mm hanging water pipe line with inverted sprinkler 83 liter per hour discharge.
System should have heavy duty sand filter, disk filter, heavy duty pump, cock assembly, pipeline, pressure gauge, 5000 liter storage tank.
Valves should be fixed after every 20 beds.
Bed Size: 10x1 meter
MS Pipe should be of Tata brand.
Water Pump – 3HP, single stage, Major Brand Hydro Products.
Sprinkler system parts should be of Major brand.
Sprinklers horizontal range should not be less than 2.5 meters.
100 to 200 beds to be covered.
Note : Exact quantity of beds to be covered will be specified according to the per bed rate of the tender awarded.
Mild Steel board with details painted on it.
• Details of work paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet. | 1 | प्रति बेड | 5,886 ₹6,945.48 Lowest | 6,745 ₹7,959.1 | 7,625 ₹7,625 |
| 1.08 | Polypropagator Structure :-
Scope of Work and Technical Specifications (Rate per Square feet )
Shape : Arch shape
Center Height : 11 feet
Height of the Structure on Sides : 11 feet
Base:
Base should be made by excavation, filling with required amount of murrum and levelling the land. Galvanised Iron Pipes should be fixed on the ground by excavating holes of size not less than 0.45m length, 0.45m width and 0.50m depth and fixing poles in Cement Concrete mix. Distance between two column pipes should not be more than 3 meters. Brickwork of 0.20m width and 0.20m height should be built on all sides of the whole structure.
Structure:
All galvanized steel should be used in design as per IS875 standards to withstand wind speed 120 km/h. Complete pre machined structure and cladding with 200 micron UV stabilized standard poly film having more than 80% light transmission. Galvanized iron pipes used as columns at base and the base of arch above column pipes should be of 2 inch thickness. GI pipes for remaining structure should be of 1.5inch thickness as per requirement. Distance between two column pipes should not be more than 3meters.
All structures, rafters, purlins, trusses are hot galvanized without welding. All main parts should be hot galvanized. Galvanised pipes of the structure should be fixed into the CC in the ground.
Galvanized steel used in the structure should be of Major Brand,
Cladding:
Ginegar brand 200 micron UV stabilized standard poly film having more than 80% light transmission. A layer of insect net should be fixed on the long sides of polypropogater. Where the insect net layer is fixed there the poly film should be made foldable such that the air circulation can be allowed. Brand of Poly Film should be Major Brand.
The tender shall be submitted on a per-square-feet basis for the complete supply, fabrication, installation, testing and commissioning of the Polypropagator Unit, including all materials, labour, transportation, fittings and accessories.
1. Structure and Framework
- Fabrication and installation of a durable, corrosion-resistant structural framework using galvanized iron (GI) pipes or equivalent approved material.
- The structure shall be adequately designed to withstand normal wind loads and the weight of the covering material.
- Suitable dimensions, height, supports, bracing and anchoring shall be provided as per the approved design.
2. Polyethylene Covering
- Covering with UV-stabilized, transparent polyethylene film suitable for nursery propagation.
- The film shall be of appropriate thickness and quality for maintaining a suitable microclimate for rooting of cuttings.
- All joints, edges and fixing arrangements shall be properly sealed to minimize moisture loss.
3. Insect-Proof Net
- Provision of suitable insect-proof net on required ventilation openings, with secure fixing arrangements to prevent insect entry while allowing controlled ventilation.
4. Gate
- Provision of one access gate of suitable size, fabricated from corrosion-resistant GI pipes or equivalent approved material.
- The gate shall be covered with UV-stabilized polyethylene film and/or insect-proof net, as applicable, and shall include suitable hinges, latch, handle and locking arrangement.
- The gate shall be properly aligned, securely fixed and easy to operate.
5. General Requirements
- All materials shall be new and of approved quality.
- The contractor shall provide a detailed material specification and structural layout before installation.
- The quoted rate per square foot shall include the complete structure, covering, insect net, one gate, fittings, labour, transportation, installation and commissioning.
- The completed unit shall be tested and handed over in fully operational condition.
- Warranty for the structure, covering, gate and installed equipment shall be specified.
The final covered area and design shall be adjusted according to the approved layout and actual site conditions. Any additional work or material beyond the above scope shall require prior approval.
Unit of Measurement: Square Feet (Sq. Ft.)
BOQ Description: Design, supply, fabrication and installation of a complete Polypropagator Unit for nursery plant propagation, including GI framework, UV-stabilized polyethylene covering, insect-proof net, one access gate, necessary fittings, labour, transportation, testing and commissioning, complete in all respects, measured on the basis of covered area in square feet.
Mild Steel board with details painted on it.
• Details of work paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet. | 1 | प्रति वर्गफीट | - | 80 ₹94.4 Lowest | 189 ₹189 |
Tender Value
Refer Docs
EMD Value
₹2.9 L
Closing Date
12 Nov 2026, 4:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
DFO
CCF office, social forestry circle indore
Construction work for Polyhouses, Mist chambers, Greenhouses, High-tech irrigation, Ground-bed sprinkler systems, Solar lighting systems and Poly-propagators (inclusive of materials).
2026_MPFD_546889_1
1960
Open Tender
Miscellaneous Works
Item Wise
25 days
Badgonda and Pipri Nursery and Tissue Culture Lab
Please refer Tender documents.
2 documents required · 2 mandatory
₹2,000
₹2.9 L
25 Nov 2026
31 Oct 2026
13 Nov 2026
31 Oct 2026
12 Nov 2026
31 Oct 2026
60 days
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1.01 | Construction work for Polyhouses, Mist chambers, Greenhouses, High-tech irrigation, Ground-bed sprinkler systems, Solar lighting systems and Poly-propagators (inclusive of materials). | - | - | - | - |
| 1.02 | Polyhouse Technical Specifications :-
1. Size & Shape
• Type: Arch-shaped polyhouse
• Center Height: 15 feet
• Side Height: 11 feet
2. Base / Foundation (Description)
1.Ground Preparation
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension per Square feet
2. Pole Foundation
• Galvanized Iron (GI) pipes must be fixed in the ground using cement concrete.
• Hole size for each pole: 0.45 m × 0.45 m × 1.0 m deep.
• Distance between two poles should not be more than 3 meters.
3. Side Brick Wall
• A small brick wall of 20 cm height and 20 cm width should be built around the entire structure.
4. Center Path
• In the middle of the polyhouse, a path of interlocking pavement blocks should be made.
• Path size: 17.88 m × 1.50 m.
5. Plant Beds
• Beds should be built on both sides of the path.
• Beds should be made using brickwork and plastered.
• Beds should be placed at 90° (right angle) to the path.
• Each bed:
• Inner width: 1 meter
• Side wall height: 20 cm
• Distance between two beds: 35 cm (including sidewalls).
• The gap between two bed walls should be filled with M-20 cement concrete, and plaster should be done on all brickwork.
3. Structure (Simple Description)
1. Material
• Entire structure should be made from Galvanized Iron (GI) steel, hot-dip galvanized.
• Structure must follow IS 875 standard and withstand 120 km/h wind speed.
2. Poles and Pipes
• Foundation GI pipes : 3.00 inch x 3.00 inch square pipes
• Main column GI pipes: 2.50 inch x 2.50 inch square pipes
• Arch base GI pipes: 1.50 inch x 1.50 inch square pipes
• Purlin: 1.50 inch x 1.50 inch square pipes
• Remaining structure pipes: 1.50 inch x 1.50 inch square pipes
• Thickness of all GI pipes should be 2mm.
• All Column GI pipes should be fixed into 3.00 inch x 3.00 inch foundation GI pipes which in turn be fixed 1.00 meter deep into cement concrete in the ground.
• There should be two purlin below the arch base.
3. Door
• 2 Aluminium frame doors with 6mm polycarbonate sheet. One door should be at front and the other at the back
4. Distance Between Columns
• Maximum 3 meters.
4. Cladding (Covering Materials)
1. Poly Film
• 200-micron UV-stabilized film
• More than 80% light transmission
• From a major/reputed brand
2. Insect Net
• 40-mesh insect net on both long sides
• Net height: from 1 meter above ground up to 2.5 meters
• Poly film in net area should be foldable to allow airflow.
3. Shade Net
• Shade-net curtains should be fixed inside the polyhouse to cover plant beds when needed.
5. Overhead Irrigation / Fogger System
• Hanging foggers with lateral pipes, supporting wire, and MS support frame.
• Fogger parts must be from a major/reputed brand.
• 1 HP pump of major brand with one year warranty should be provided .
• 1000-liter water tank for fogger supply.
6. Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 10 feet width outside it.
7. Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or the poly film.
8. Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
9. 12mm Electricity service cable of 50 meter should be fixed from supply line to polyhouse.
10. All the electric equipment should be placed in a well insulated cabin. | 1 | प्रति वर्गफीट | - | - |
| 1.03 | Mist Chamber Technical Specification :-
Shape : Arch shape
Center Height : 4 meter
Sidewall Height : 1 meter
Height of Polycarbonate Sheet Above Walls : 1.5 meter
Evaporative Cooling System
1.5 meter tall with lengthwise evaporative Cellulose complete set cooling pad with all necessary framing material of aluminium required supporting distribution & returning piping, gutters down spout end caps and drip pan, plumbing kit, pump capacity as per requirement. Drilled PVC piping cap, pad retainer, all suspension hardware, metal flashing as required to seal pad to vent opening, 4” thick evaporative.
Cooling pad material :
Pad construction material, aluminium profiles, tray sides, water distribution tray, cooling media 100mm thick
Water storage tank capacity : 2000 liter (Major Brand)
40 Mesh Nylon for extra protection from dust, fitted behind pad
1HP water pump of major brand with one year warranty should be used in cooling system
Civil Works:
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension 10 meter x 10 meter x 0.80 meter
Structure will be raised on RCC with columns and beams as per requirement, foundation wall of width 20cm for all sides of mist chamber.
Wall around the structure should be of at least 1 meter height above ground and thickness of the wall shoud be of 20cm.
Filling of base with hard murrum and making it compact such that it remains stable. RCC Floor above murrum base of 5cm thickness.
Three platforms should be raised above floor for germination beds with following specifications:
• Inner Dimension of germination beds–
▪ Middle bed 7x1x0.20 meter (length x width x depth)
▪ Beds on sides 8x1x0.20 meter (length x width x depth)
• Base of germination beds should be of RCC.
• Germination beds should be raised on RCC Columns of required numbers.
• Height of Platforms not be less than 1 meter
• Installation of tiles should be done on the inner and outer walls and top walls of the germination platforms and also on the columns on which ths germination beds are raised.
• All walls and columns shoul be plastered with 12mm thickness cement plaster.
Structure Frame :
• All galvanized iron should be used design as per IS875 standards to withstand wind speed 120 km/h. Complete pre machined structure and cladding with polycarbonate sheet 6 mm thick multiwall UV stabilized material:
• All structures, rafters, purlins, trusses should be hot galvanized without welding. All main parts should be hot galvanized.
• Galvanised pipes of the structure should be fixed into the RCC columns of the structure with the help of fasteners and RCC. GI Columns pipes should be of thickness 2x2 inch. Base of the arch above column pipes should be made with 2x2 inch GI pipes.
• The galvanized iron used in frame should be of major brand. Steel used in RCC should be of major brand .
• Door should be fixed for entry in mist chamber Made with aluminium frame and fixed with 6mm polycarbonate sheet.
Fixing of UV stabilized Polycarbonate sheet:
Polycarbonate sheet of 6 mm thickness should be fixed on GI pipes with heavy duty aluminium profile on both sides.
Fogging System :
• Hanging fogging system with heavy duty water pump with fourway fogger(22lph), sand filter, screen filter and pressure meter to raise Relative Humidity upto 90%.
• Water pump for fogging system should be 3HP and of major brand with one year warranty and with a provision of AMC (Annual Maintanance Cover)
• All fogging system parts should be of major brand
• Screen filter and sand filter should be of major brand
Climate Control System :
• Two heavy duty exhaust fans of 54 inch outer diameter should be fixed
• Electronic climate control system which can monitor and control temperature and humidity. It should maintain chamber climate by contolling chamber equipments like cooling fan, foggers etc. It should have manual and automatic working options. One should be able to set required humidity and temperature with help of control pannel fitted with LCD screen.
• Electronic climate control system should control two exhaust fans, fogging system and cooling system with input from temperature and humidity sensor.
Permanent Brick Structure for housing all Electronic and Electrical equipments should be made attached outside the structure.
Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 5 feet width outside it.
Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or the polycarbonate sheet.
12mm Electricity service cable of 20 meter should be fixed from supply line to polyhouse. | 1 | प्रति वर्गमीटर | - | - |
| 1.04 | Overhead Sprinkler Irrigation System :-
Scope of Work and Materials Required
The quotation must cover the complete supply, installation, testing and commissioning of the Overhead Sprinkler Irrigation System, including all required materials, fittings, accessories, labour and installation charges, as per the following specifications:
1. Overhead Sprinkler Irrigation Setup:
- Bed Dimensions: 10 meters (length) × 0.15 meters (width) × 1.20 meters (height), as per the existing layout.
- Sprinkler System: Supply and installation of overhead sprinklers suitable for uniform irrigation of nursery beds.
- Sprinkler Heads: Heavy-duty, corrosion-resistant impact or rotary sprinkler heads with suitable nozzles, providing uniform water distribution.
- Sprinkler Spacing: Sprinklers shall be installed at suitable spacing, generally 3–4 meters apart, subject to the manufacturer's specifications, spray radius and approved irrigation layout.
- Risers and Supports: Supply and installation of suitable PVC/HDPE riser pipes, clamps, brackets and supports to position sprinkler heads above the nursery beds and ensure uniform water coverage.
- Lateral Pipes: Supply and installation of suitable-size PVC/HDPE lateral pipes connecting the sprinklers to the main supply line.
- Fittings and Accessories: All required tees, elbows, reducers, sockets, unions, end caps, clamps, connectors and other accessories for a complete operational system.
- Control Valves: Provision of valves for individual sections/zones to facilitate sector-wise irrigation and independent operation.
2. Main Water Supply Line:
- Main Pipe: 75 mm diameter PVC pipe of suitable pressure rating, as approved by the competent authority.
- Total Length: 300 meters of main supply piping.
- Installation: Complete laying, jointing, alignment, trenching wherever required, backfilling, testing and commissioning of the main pipeline.
- Branch Connections: Necessary branch pipelines, fittings and control valves for supplying water to the sprinkler zones.
3. Water Source and Storage:
- Water Tank: Supply and installation of one 2,000-litre capacity water storage tank, including necessary inlet, outlet, overflow and drain connections.
- Tank Foundation: Suitable base/support for safe installation of the tank, wherever required.
- Suction Arrangement: Necessary suction piping, foot valve, strainer and associated fittings for reliable pump operation.
4. Pumping System:
- Water Pump: Supply and installation of one 3 HP electric motor-pump set of a reputed brand, with a minimum one-year manufacturer's warranty.
- Pump Selection: The pump shall be suitable for the required discharge and operating pressure of the sprinkler system, as established by hydraulic calculations.
- Accessories: Necessary starter/control panel, electrical cables, earthing, protection devices, pressure gauge, non-return valve and other accessories required for safe and efficient operation.
- Electrical Safety: All electrical equipment shall be installed in a properly insulated and weather-protected enclosure.
5. Filtration System:
- Screen Filter: Supply and installation of a screen filter of suitable capacity to prevent nozzle blockage.
- Sand/Media Filter: Provision of a sand/media filter wherever required, depending on the quality and source of irrigation water.
- Filter Accessories: Necessary valves, connectors, pressure gauges and cleaning/backwashing arrangements, as applicable.
6. Fertilizer Application System:
- Fertigation Unit: Supply and installation of a Venturi injector system suitable for fertilizer application through the sprinkler irrigation network.
- Accessories: Fertilizer mixing tank, connecting pipes, control valves and other necessary fittings.
- The system shall permit controlled fertilizer application without compromising sprinkler performance.
7. Testing and Commissioning:
- Complete installation, flushing and pressure testing of all pipelines.
- Testing of sprinkler discharge, spray radius, pressure and uniformity of water distribution.
- Demonstration of sector-wise operation and fertilizer injection.
- Rectification of leakage, defective joints and installation-related defects before handing over the system.
- Supply of operating instructions and warranty documents.
8. General Conditions:
- The quoted rate shall include all materials, labour, transportation, installation, fittings, testing and commissioning charges.
- All materials shall be new, durable and of approved quality.
- The contractor shall submit the sprinkler layout, technical specifications, pump performance details and material list for approval before installation.
- The complete system shall be handed over in fully operational condition.
- Any additional accessories required for satisfactory functioning of the system shall be included in the quotation. | 1 | प्रति बेड | - | - |
| 1.05 | Green Shadenet House Technical Specification :-
Size & Shape
• Shape: Even Span Type
• Center Height: 12 feet
• Side Height: 10 feet
2. Base / Foundation (Description)
1. Ground Preparation:
• The land must be levelled, filled with hard copra murrum, and leveled properly.
• Land should be filled with hard copra murrum in dimension per Square feet
2. Pole Foundation: Galvanized Iron (GI) pipes must be fixed in the ground using cement concrete. Hole size for each pole: 0.45 m x 0.45 m x 0.50 m deep. Distance between two poles should not be more than 3 meters.
3. Side Brick Wall: A small brick wall of 20 cm height and 20 cm width should be built around the entire structure. This wall should also be plastered.
4. Center Path: In the middle of the polyhouse, a path of interlocking pavement blocks should be made. Path size: 18.288 m x 1.50 m.
5. Plant Beds:
• Beds should be built on both sides of the path.
• Beds should be made using brickwork and plastered.
• Beds should be placed at 90° (right angle) to the path.
• Each bed: Inner width: 1 meter, Side wall height: 20 cm,
• Distance between two beds: 35 cm (including sidewalls).
• The gap between two bed walls should be filled with M-20 cement concrete, and plaster should be done on all brickwork.
3. Structure (Simple Description)
1. Material: Entire structure should be made from Galvanized Iron (GI) steel, hot-dip galvanized. Structure must follow IS875 standard and withstand 120 km/h wind speed.
2. Poles and Pipes:
• Main column GI pipes: 3 inch x 3 inch square pipes
• Remaining structure pipes: 1.5 inch x 1.5 inch square pipes
3. Door: 2 Aluminium frame doors with 6mm green coloured polycarbonate
sheet. One door should be at front and the other at the
back.
4. Distance Between Main Columns: Maximum 3 meters.
Cladding (Covering Materials)
1.green net UV-stabilized shade net with 75% light transmission. From a major/reputed brand.
Industrial Cladding & Anchoring: Structured requirements for the UV-stabilized green shade net utilizing professional aluminum profiles and zig-zag structural locking springs to prevent flapping or wind damage.
4 . Overhead Irrigation / Fogger System
• Hanging 4 way sprinkler system with lateral pipes, supporting wire, and MS support frame.
• sprinkler parts must be from a major/reputed brand.
• 3 HP pump with starter, both of major brand with one year warranty should be provided.
• 2000-liter water tank for sprinkler supply
• Main supply pipe for sprinkler lateral pipes should be 63 mm UPVC pipes
• Sprinkler’s lateral pipes should be fitted parallel to the center path at the interval of 1 meter.
• Sprinklers should be fitted at the interval of 1 meter.
• Sand and Screen filter should be fitted for sprinkler supply. The aforementioned filters should be of major brand and with one year warranty.
• Control valves should be fitted where required or as directed at site.
Headworks: Explicit technical layout mapping your 63mm UPVC mains across a 60-meter running stretch feeding 20 overhead micro-sprinkler assemblies with comprehensive filtration, control valves, and system pressure gauges.
Permanent Brick Structure for housing all Electronic and Electrical equipments should be made attached outside the structure.
Mild Steel board with details painted on it.
• Details to paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet.
Interlocked pavement block around the structure
• Path around the structure should be made of interlocked pavement blocks surrounding it up to 5 feet width outside it.
Monkey protection mesh should be fixed around and above the structure covering the whole structure. The mesh should be able to sustain jerks of monkey jumping on it, without damaging the structure or shadenet.
12mm Electricity service cable of 20 meter should be fixed from supply line to polyhouse. | 1 | प्रति वर्गफीट | - | - |
| 1.06 | Solar street light system specification :-
Solar street light with 18 watt LED lamp( Major Brand like Havells/philips), 40Ah battery(Major Brand like Luminous/Amaron) and 100 watt solar panel(Major/Reputed Brand, Example-Tata/Adani) with 15 feet GI pole arm, brackets etc. Complete fitting with concrete foundation. Warranty should be 25 years for panel and 5 years for all remaining system. | 1 | प्रति इकाई | - | - |
| 1.07 | High Tech Irrigation System :-
High tech irrigation system supply and installation for hanging irrigation sprinkler system, MS pipe main vertical column 1.5 inch x 1.5 inch square pipe heavy duty two pole distance 3 meter and horizontal purlin 1.25x1.25 inch heavy duty arrangement of 16mm hanging water pipe line with inverted sprinkler 83 liter per hour discharge.
System should have heavy duty sand filter, disk filter, heavy duty pump, cock assembly, pipeline, pressure gauge, 5000 liter storage tank.
Valves should be fixed after every 20 beds.
Bed Size: 10x1 meter
MS Pipe should be of Tata brand.
Water Pump – 3HP, single stage, Major Brand Hydro Products.
Sprinkler system parts should be of Major brand.
Sprinklers horizontal range should not be less than 2.5 meters.
100 to 200 beds to be covered.
Note : Exact quantity of beds to be covered will be specified according to the per bed rate of the tender awarded.
Mild Steel board with details painted on it.
• Details of work paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet. | 1 | प्रति बेड | - | - |
| 1.08 | Polypropagator Structure :-
Scope of Work and Technical Specifications (Rate per Square feet )
Shape : Arch shape
Center Height : 11 feet
Height of the Structure on Sides : 11 feet
Base:
Base should be made by excavation, filling with required amount of murrum and levelling the land. Galvanised Iron Pipes should be fixed on the ground by excavating holes of size not less than 0.45m length, 0.45m width and 0.50m depth and fixing poles in Cement Concrete mix. Distance between two column pipes should not be more than 3 meters. Brickwork of 0.20m width and 0.20m height should be built on all sides of the whole structure.
Structure:
All galvanized steel should be used in design as per IS875 standards to withstand wind speed 120 km/h. Complete pre machined structure and cladding with 200 micron UV stabilized standard poly film having more than 80% light transmission. Galvanized iron pipes used as columns at base and the base of arch above column pipes should be of 2 inch thickness. GI pipes for remaining structure should be of 1.5inch thickness as per requirement. Distance between two column pipes should not be more than 3meters.
All structures, rafters, purlins, trusses are hot galvanized without welding. All main parts should be hot galvanized. Galvanised pipes of the structure should be fixed into the CC in the ground.
Galvanized steel used in the structure should be of Major Brand,
Cladding:
Ginegar brand 200 micron UV stabilized standard poly film having more than 80% light transmission. A layer of insect net should be fixed on the long sides of polypropogater. Where the insect net layer is fixed there the poly film should be made foldable such that the air circulation can be allowed. Brand of Poly Film should be Major Brand.
The tender shall be submitted on a per-square-feet basis for the complete supply, fabrication, installation, testing and commissioning of the Polypropagator Unit, including all materials, labour, transportation, fittings and accessories.
1. Structure and Framework
- Fabrication and installation of a durable, corrosion-resistant structural framework using galvanized iron (GI) pipes or equivalent approved material.
- The structure shall be adequately designed to withstand normal wind loads and the weight of the covering material.
- Suitable dimensions, height, supports, bracing and anchoring shall be provided as per the approved design.
2. Polyethylene Covering
- Covering with UV-stabilized, transparent polyethylene film suitable for nursery propagation.
- The film shall be of appropriate thickness and quality for maintaining a suitable microclimate for rooting of cuttings.
- All joints, edges and fixing arrangements shall be properly sealed to minimize moisture loss.
3. Insect-Proof Net
- Provision of suitable insect-proof net on required ventilation openings, with secure fixing arrangements to prevent insect entry while allowing controlled ventilation.
4. Gate
- Provision of one access gate of suitable size, fabricated from corrosion-resistant GI pipes or equivalent approved material.
- The gate shall be covered with UV-stabilized polyethylene film and/or insect-proof net, as applicable, and shall include suitable hinges, latch, handle and locking arrangement.
- The gate shall be properly aligned, securely fixed and easy to operate.
5. General Requirements
- All materials shall be new and of approved quality.
- The contractor shall provide a detailed material specification and structural layout before installation.
- The quoted rate per square foot shall include the complete structure, covering, insect net, one gate, fittings, labour, transportation, installation and commissioning.
- The completed unit shall be tested and handed over in fully operational condition.
- Warranty for the structure, covering, gate and installed equipment shall be specified.
The final covered area and design shall be adjusted according to the approved layout and actual site conditions. Any additional work or material beyond the above scope shall require prior approval.
Unit of Measurement: Square Feet (Sq. Ft.)
BOQ Description: Design, supply, fabrication and installation of a complete Polypropagator Unit for nursery plant propagation, including GI framework, UV-stabilized polyethylene covering, insect-proof net, one access gate, necessary fittings, labour, transportation, testing and commissioning, complete in all respects, measured on the basis of covered area in square feet.
Mild Steel board with details painted on it.
• Details of work paint will be provided by the nursery staff.
• Size of the board should be 4 feet x 5 feet.
• Height of the board above ground should be 7 feet. | 1 | प्रति वर्गफीट | - | - |
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
tdd.pdf
Tender Documents • 1.39 MB
BOQ_657916.xls
BOQ • 0.43 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .