| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.1 LAccepted-AOC 702 A1 SHREE PRASAD TAWADEWADI SHREE DATTAGURU PARK KUMBHARWADA URAN DIST RAIGAD MAHARASHTRA 400 702 | URAN | RAIGAD | MAHARASHTRA | 400702 | L1 | Accepted-AOC AOC | |
| 2 | L2₹15.5 L+₹1.1 L (7.38%)Rejected-Finance | L2 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 3 | L3₹16.0 L+₹1.5 L (10.6%)Rejected-Finance | L3 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 4 | L4₹17.0 L+₹2.6 L (17.9%)Rejected-Finance WZ 1043 C IIND FLOOR NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L4 | Rejected-Finance HIGHER THAN L1 BIDDER | |
| 5 | L5₹18.0 L+₹3.6 L (24.6%)Rejected-Finance | L5 | Rejected-Finance HIGHER THAN L1 BIDDER |
Tender Value
₹26.5 L
EMD Value
₹52,920
Closing Date
30 Sept 2024, 6:00 pmClosed
LT COL VISHAL BHURIA
GE I Kanpur Cariappa Road Cantt Kanpur 208004
SPL REPAIR OF MAGAZINE BUILDING AT KANPUR PROOF RANGE (KPR) AND SPECIAL REPAIR OF OLD ALUMINIUM WIRING INTO COPPER WIRING AND ALLIED SERVICES AT ADMIN BUILDING OF SQAE (SA) UNDER GE(I) KANPUR
2024_MES_669932_1
GE(I)/KAN/T-57 OF 2024-25
Open Tender
Civil Works
Item Rate
180 days
KANPUR
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
GE(I) KANPUR
₹52,920
Yes
7 Dec 2024
2 Sept 2024
7 Oct 2024
2 Sept 2024
30 Sept 2024
16 Sept 2024
Amount
Taking down/dismantling of existing roof treatment of any description such as PCC Padding/ Coba treatment/ mud phuska/Lime conc terracing including screed bed ,brick tiles etc. Hessian base felt/tar felt etc. (any type and thickness) complete all as specified and directed.
M&L providing PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in bed plates coping, padding complete all as specified and directed.
Material and labour for applying 10 mm thick plaster in CM 1:4 mixed with and including water proofing compound @ 3% by weight of cement complete all as specified and directed.
M&L for APP modified membrane water proofing treatment on roof slab complete all as specified and directed. (a) Preparation of plastered roof surfaces ,throughly wire brushed,washed,dried up & cleaned to remove all foreign material & dust to receive primer. etc. (b) Applying a uniform coat of bituminous primer T-10/polymerised primer oil based @0.3 ltr per sqm as per manufacture instruction (c) On this primed surface, the approved APP modified bituminous membrane pre fabricated with non -woven polyester reinforced stablised with fibre glass strands & top with grey mineral slates 3 mm thick weighing n less than 3.5 kg/sqm shall be laid by torch application. (d) The APP membrane shall be laid with 100mm and 150 mm over laps on side and end laps respectively. (e) The above treatment shall be carried out by approved applicator & manufacturer.
Material and labour PCC 1:2:4 type B-0 using 12.5mm stone aggregate in fillets junction of roof and parapet wall caving slightly chamfered or rounded mixed with and including water proofing compound @3% by weight of cement complete all as specified and directed.
S&F in repair110 mm bore PVC (SWR) Soil waste, rain water pipe and vent pipes single socketed in any length with rubber ring joints fixed to walls including making good disturbed portion to match the existing complete all as specified and directed.
S&F in repair 110 mm bore PVC (SWR) bends of any radius with access door including making good disturbed portion to match the existing complete all as specified and directed.
Roughening of surface of old concret floor by picking sweeping clean and washing down with water to remove dust etc complete all as specified and directed.
M&L for 20-25 mm thick machine cut kota stone slab flooring over and including 20mm thick cement screed bed in CM 1:6 , laid and jointed with grey cement slurry mixed with pigment to match the shade of stone slab including cutting, grinding, rubbing and polishing complete all as specified and directed.
All as per Item No. 9.00 above but in skirting over and including 10mm thick rendring in CM 1:4 complete all as specified and directed.
Taking down chowkats or frame with shutter (without taking off shutters from the frame) not exc 1.5 Sqm each complete all as specified and directed.
S&F steel ventilators with top hung shutter & glazing bars hinges, steel peg stay complete all as specified and directed.
S&F framed work such as guard bars, grills etc and similar work confirming to Fe-290 Gde E-165 complete all as specified and directed.
M&L for PCC 1:3:6, type C-1 (using 20mm graded stone aggregate) for embedding of hold fast etc including making good disturbed surfase of existing position complete all as specified and directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in square not exc 0.5 Sqm in each pane complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
Taking down cement plaster from brick wall/ ceiling including racking out joints, hacking for key & scrubbing down with water where existing complete all as specified and directed.
M&L for rendering 15mm thick in cement mortar 1:6 on stone masonry surfaces or surface other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for 15 mm thick rendering in cement mortar 1:4 on fair faces of concrete or brick surface finished even and smooth without using extra cement mixed wiith water proofing compound 3% by weight of cement or as per manufacturer instruction complete all as specified and directed. Note: WPC shall be measured separately under supply only.
M&L for 10 mm thick cement plaster on ceiling in CM 1:3 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of newly plastered surfaces of celing and applying three coat of white complete all as specified and directed.
Supply only Integral water proofing compound complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of cement base paint over a coat of cement primer complete all as specified and directed.
M&L for preparation of newly plastered surfaces of wall and applying two coat of oil bound distemper over a coat of primer complete all as specified and directed.
M&L for preparation of old decorated surfaces of wall ,cornice, fins , facia and column offsets plaster etc. plastered or un plastered by brooming down to remove all dust and all loose scales of lime/colour wash and applying two coat of cement base paint on walls including necessary scafolding and saftey precautions upto height 7 metre complete all as specified and directed.
M&L for preparing old distempered surface by brooming down stopping and distempering wall incl cornice plaster with two coat of oil bound distemper complete all as specified and directed.
S&F stack clamps made out of 50 mm x 5 mm flat iron and 16 mm dia round iron stays, including bolts and nut and securing ends of stays to wall or roof for 100 mm bore of pipe complete all as specified and directed.
Cutting holes through brick walls built, in cement mortar and making good in cement concrete (1:2:4) type B-1 as required, superficial area exc 400 sqcm but n’exc. 0.10 sqm, complete all as specified and directed.
M&L for preparation of old painted surfaces of steel of any description, over 10cm in width or girth and apply one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of old plastered surfaces of ceilings and apply two coat of white wash complete all as specified and directed.
Taking down eaves gutter and rainwater pipes (any size or pattern) including all fittings, head, shoes, bends, swan-necks etc complete all as specified and directed.
Taking down copper/aluminium point wiring (light, fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting fans etc.removing materials to store for keeping in safe custody or for taking credit (credit for above items should be made as per conditions separately) and making good disturbed surfaces of walls floors etc complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including concealed conduit in / on wall/ceiling with provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following:- a). One light point controlled by one 05 Amps switch complete all as specified and directed.
All as per item No 33.00 above but for One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No 33.00 above but for One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No 33.00 above but forOne socket out multi pin 5 Amps controlled by one switch on same board complete all as specified and directed.
All as per item No 33.00 above but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No 33.00 above but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqmm PVC copper conductor and provn of 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
Material and labour for point wiring with 1.5 sqmm single core PVC insulated unsheathed cable 1100 volt FRLS grade ISI marked with multistranded copper conductor drawn through and including Existing rigid PVC concealed conduit on wall/ceiling with and including provision of MS box of suitable size with 3mm thick laminated hylam sheet cover for housing switch, socket, etc incl provision of 1.5 sqmm single core cable green in colour PVC insulated copper conductor as earth continuity conductor connected to earth dolly for following:- a). One light point controlled by one 05 Amps switch complete all as specified and directed.
All as per item No 39.00 above but for One fan/Exhaust fan point controlled by one switch complete all as specified and directed.
All as per item No 39.00 above but for One socket out multi pin 5 Amps controlled by one switch on independant board complete all as specified and directed.
All as per item No 39.00 above but for One socket out multi pin 5 Amps controlled by one switch on same board complete all as specified and directed.
All as per item No 39.00 above but for one socket out let 2in1 5 and 15 Amps with 2.5 Sqmm PVC insulated copper conductor and provn of 2.5 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
All as per item No 39.00 above but for one socket out let 2 in 1, 5 and 15 Amps or AC point with 4 Sqmm PVC copper conductor and provn of 4.0 sqmm PVC insulated single core copper cable green in colour as earth continuity conductor complete all as specified and directed.
M&L cutting chases, pinning in,making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sun shadows, sheves lintels etc and cutting chases for concealed water tubing or concealed wiring etc and making good cutting n . exc 10 cm girth complete all as specified and directed.
M&L cutting chases, pinning in,making good to facings where required and pointing in cement mortar 1:3 to ends or edges of landings, steps cills, sun shadows, sheves lintels etc and cutting chases for concealed water tubing or concealed wiring etc and making good cutting exc 10 cm girth & n. exc 20 cm girth complete all as specified and directed.
S&F in replacement switch piano 5 Amps one way complete all as specified and directed.
S&F in replacement ceiling rose 2 to 3 terminal backelite complete all as specified and directed.
S&F Lamp holder insulated body with back plate for dome batten fittings complete all as specified and directed.
S&F in replacement socket outlet 6 Amps multi purpose flush type complete all as specified and directed.
S&F in replacement socket outlet 2 in 1, 3 pin, 5 and 15 Amps flush type complete all as specified and directed.
S&F in replacement switch piano, flush ype single pole 15 Amps complete all as specified and directed.
Supply and fix in replacement fan regulator electronic type 100 watts 5 step huming free operation complete all as specified and directed.
S&F modular switch piano flush type 6 Amp single pole one way, one module complete all as specified and directed.
S&F modular switch one way , flush type 15 Amp 240 volt complete, one module complete all as specified and directed.
S&F modular socket out let 3 Pin 6 Amp, flush type 240 Volt complete, 2 module complete all as specified and directed.
S&F Modular socket out let 2 in 1 , 3 pin 5 & 15 Amp , 240 volt, 2 module complete all as specified and directed.
S& F modular Electronic ceiling fan regulator step type, 120 W , 2 module step type complete all as specified and directed.
S&F modular white cover plate with frame 1/2 module complete all as specified and directed.
S&F Modular white cover plate with frame 3 module complete all as specified and directed.
S&F Modular white cover plate with frame 4 module complete all as specified and directed.
S&F Modular white cover plate with frame 6 module complete all as specified and directed.
S&F Modular white cover plate with frame 8 module complete all as specified and directed.
S&F modular metal flush box 1/2 module complete all as specified and directed.
S&F modular metal flush box 3 module complete all as specified and directed.
S&F modular metal flush box 4 module complete all as specified and directed.
S&F modular metal flush box 6 module complete all as specified and directed.
S&F modular metal flush box 8 module, Note : for item No. 24 to 39 complete all as specified and directed.
S&F in replacement Industrial socket single pole and enclosure with a two pin and earth plug complete with one single pole MCB 20A complete all as specified and directed.
Supply and fix in replcement MCB DB double door type single phase with common eath and neutral bus and 200 amps copper bus bars complet , 240 volts 12 way complete all as specified and directed.
All as per item No. 70.00 above but of 8 way complete all as specified and directed.
All as per item No. 70.00 above but of 4 way complete all as specified and directed.
Supply and fixing in replacement TPN DB's 4 way vertical type 415 V, double door suitable for housing of 63 Amps MCCB as main incoming complete all as specified and directed.
S&F in replacement MCCB of capacity 63 Amps, fixed thermal and magnetic release, 4 Pole, 16 KA suitable to be fixed in 4 way TPN DB complete all as specified and directed.
S&F MCCB 100 Amps capacity, 4 pole, 16 KA, fixed thermal and magnetic release complete with extended terminals to be fixed in 4 way TPN DB complete all as specified and directed.
S&F MCB SP 6-32 Amps, 10 KA, 'C' series complete all as specified and directed.
S&F MCB SP 40-63 Amps, , 10 KA, 'C' Series complete all as specified and directed.
S&F MCB SPN 63 Amps, 10 KA, 'C' Series complete all as specified and directed.
S&F MCB SPN 40 Amps, , 10 KA, 'C' Series complete all as specified and directed.
Taking down old unserviceable aluminium sub main wiring and S&F sub main wiring for circuit of size 10 sq mm 2 core alongwith earth wire of 10 sq mm single core of FRLS PVC insulated unsheathed cable (FR), 1100 volts grade with multistranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including PVC non metalic rigid conduit/casing of suitable size and conduit/casing accessories run on surface of wall/ceiling etc and connecting terminal ends of suitable size complete all as specified and directed.
All as per item No. 80.00 above but with wire 6 sq mm 2 core with 6 sq mm single core as earth continuity complete all as specified and directed.
All as per item No 80.00 above but with wire 2.5 sq mm 2 core with 2.5 sq mm single core as earth continuity complete all as specified and directed.
All as per item No. 80.00 above but with wire 4 sq mm 2 core with 4 sq mm single core as earth continuity complete all as specified and directed.
Taking down old unserviceable aluminium sub main wiring, material and labour for sub main wiring complete with 4 runs of 10 sqmm PVC insulated and unsheathed cable with multi stranded copper conductor, conforming to IS-649, 1100 V grade (FR) and drawn through and including PVC non metalic rigid conduit of suitable size and conduit accessories run on surface of wall/ceiling etc and connecting terminal ends including 2 run of 10 sqmm PVC insulated un-sheathed copper conductor cable green colour as contineous earth continuity conductor and connecting to earth dolly complete all as specified and directed.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G I wire 4 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 15 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
M&L for earthing complete withGI plate electrodes 600x600x6.3mm thick buried directly in ground earth pit not less than 2.25m deep below normal ground level with top edge of earth plate not less than 1.5m below ground level connected to G I strip 32x 6 mm as earthing lead fixed by means of nut bolt washer of brass as shown in electrical plate No.3 of SSR Pt-I 2009 including necessary excavation and earth work in any strata, GI pipe 20mm dia light grade for watering , and 40 mm light grade as protrection to earth wire upto 7.5 mtr ,charcoal & salt etc and PCC chamber in PCC 1:3:6 type C1 covered with 40mm thick RCC 1:2:4 type B1 using 20mm graded stone aggregate reinforced with 8mm dia MS bar @ 75mm C/C both ways cover, funnel & wire mesh including making of test point all as specified testing on complete.
Supply and laying and testing cable in repair XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 50 sq mm 3.5 core including Lugs, nuts, bolts ,claimp fo fixing of cable on wall surface etc complete all as specified and directed.
Supply and fixing 10W surface mounted IP65 Bulkhead with system efficiency of 100LM/Watt LED bulk head shall be made up of Die cast PVC housing for better heat decapitation.P.F>.95with THD <10%,surge protection 4KV input voltage rane 150Vto 270V including connecting electricaly to ceiling rose using cord flexible 3 core PVC insulated over all sheathed with flexible copper conductor of size 0.75 sqmm complete all as specified and directed.
M&L for GI tubing 40 mm dia (Medium grade) with all necessary fitting laid in trenches/under road crossing, or fixed on poles/walls/under floor etc complete all as specified and directed.
M&L air termination single pointed Aluminum rod 12mm dia & 300mm long complete all as specified and directed.
Supply & fix aluminium strip 25 mm x 3.15 mm on wall , roof & ground etc. complete with saddles, and fixing screws complete all as specified and directed.
Supply and fix epoxy insulators 25 mm dia base with suitable screws complete for fixing AL strip if size 25x3.15 mm complete all as specified and directed.
M&L for Test point terminal block made of gun metal or phosphorus bronze size 75x75x25 mm drilled and screwed including three nos 8 mm dia 25mm long hexonagal head screws complete all as specified and directed.
Material and labour MS Plate girder or single stanchions , built up of one beam or channel section with flange plates, caps, bases. splices, angle brackets, cleats and other connections Fe 410-W (Gde- E- 250) quality-A.
M&L GI tubing medium grade 50mm dia for air termination complete all as specified and directed.
S&F earth continuity conductor or main earthing lead of GI strip of size 32X6 mm, fixed to wall or battens or recess or chases or buried in ground in conduit / GI pipe or any other indicated situation for loop of earthing etc as required of complete all as specified and directed.
M&L for Point wiring complete with PVC insulated, unsheathed cable, 1100 volts grade with multistranded copper conductor of 1.5 sq mm (HFFR) drawn through and including concealed steel conduit of suitable size including chase cutting and redressing of surfaces with PCC and touch painting complete including PVC insulated sheathed multistranded copper conductor of size 1.5 sq mm (FRLS) as earth continuity conductor and connecting to common earth dolly all as specified for :- One light point control by one switch complete all as specified and directed.
S&F switch Flame Proof rotary type with termination box in LM6, 16 Amp, double pole, 250 V complete all as specified and directed.
S&F RCCB, 25 Amp, 30 mA , 2 pole complete all as specified and directed.
Earthing continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed or any other indicated situation for loop earthing etc. As required 4 mm dia galvanised iron or steel wire complete all as specified and directed.
S&F sub main wiring for circuit of size 1.5 sq mm 2 runs (HFFR) alongwith earth wire of 1.5 sq mm single runs of FRLS PVC insulated unsheathed cable, 1100 volts grade with multistranded copper conductor including steel conduit of suitable size complete all as specified and directed.
Supply and lay XLPE insulated, armoured heavy duty electric cable with aluminium conductor 1100 volts grade, in trenches /on the wall surface of cross sectional area 10 Sqmm 2 core including Lugs, nuts, bolts ,claimp fo fixing of cable on wall surface etc complete all as specified and directed.
S&F LED flame Proof light FLP well glass 40 watt LED, 240 V, 50 Hz, complete all as specified and directed.
Taking down old unserviceable aluminium sub main wiring and S&F sub main wiring for circuit of size 2.5 sq mm 2 core alongwith earth wire of 2.5 sq mm single core o f( HFFR) PVC insulated unsheathed cable , 1100 volts grade with multistranded copper conductor, conforming to IS-649, 1100 V grade and drawn through and including ERW steel conduit/casing of suitable size and conduit/casing accessories run on surface of wall/ceiling etc and connecting terminal ends of suitable size complete all as specified and directed.
ADITYA VIKRAM SINGH ASSOCIATES (BID ID -3107098)
J.B.ENTERPRISES (BID ID -3106620)
M/S AADI ENTERPRISES (BID ID -3105596)
classic contriction co. (BID ID -3108371)
M/s Raghvendra Traders (BID ID -3102938)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .