Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹45.8 LAccepted-AOC | ₹45.8 L | L1 | Accepted-AOC Lowest bid value |
| 2 | L2₹47.0 L+₹1.2 L (2.65%)Rejected-AOC | ₹47.0 L+₹1.2 L (2.65%) | L2 | Rejected-AOC Higher bid value |
| 3 | L3₹47.4 L+₹1.6 L (3.48%)Rejected-AOC | ₹47.4 L+₹1.6 L (3.48%) | L3 | Rejected-AOC Higher bid value |
| 4 | L4₹48.4 L+₹2.6 L (5.71%)Rejected-AOC | ₹48.4 L+₹2.6 L (5.71%) | L4 | Rejected-AOC Higher bid value |
| 5 | L5₹48.5 L+₹2.7 L (5.86%)Rejected-AOC | ₹48.5 L+₹2.7 L (5.86%) | L5 | Rejected-AOC Higher bid value |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
16 Jul 2024, 6:00 pmClosed
GE 868 EWS
GE 868 EWS PIN- 913 868 C/o 99 APO
REPAIR MAINT OF CONSTANT CURRENT REGULAR AND SERVO CONTROL VOLTAGE STABLIZER AT RMS RAPAIR MAINT OF DG SETS OF VARIOUS CAPACITIES AT WATER SUPPLY INSTALLATION
2024_MES_662804_1
8763/C/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
RANGAPAHAR
Class D
Category b (i)
2 documents required · 2 mandatory
₹500
GE 868 EWS
₹90,000
Yes
2 Sept 2024
28 Jun 2024
18 Jul 2024
28 Jun 2024
16 Jul 2024
11 Jul 2024
28 Jun 2024 - 4 Jul 2024
Amount
Carrying out of 'B' check of DG set cap 160 to 200 KVA on quarterly basis through rep/ mechnic of OEM including checking, cleaning, adjusting/tightening,oiling, greasing and reseting of existing part 'decarbonising of battery terminals of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc complete all as specified and as directed. Note :- Spares part shall be measured and paid separately under respective item of Sch A.
Change of Engine oil
Change of Engine oil filtter
Change of fuel filter
Change of Air Filter
Change of water separator
Carrying out of 'B' check of DG set cap 62.5 to 125 KVA on quarterly basis through rep/ mech of OEM including checking, cleaning, adjusting/tightening,oiling, greasing and reseting of existing part 'decarbonising of battery terminals of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc complete all as specified and as directed. Note :- Spares part shall be measured and paid separately under respective item of Sch A.
Change of Engine oil
Change of Engine oil filtter
Change of fuel filter
Change of Air Filter
Change of water separator
Carrying out of 'B' check of DG set cap 7.5 to 30 KVA on quarterly basis through rep/ mech of OEM including checking, cleaning, adjusting/tightening,oiling, greasing and reseting of existing part 'decarbonising of battery terminals of DG Set at different location of installation and keep ready to set for proper functioning of valve 'V' belts, pulleys, Fan hub, idler, water pump, filters, engine cylinder head, bolts, nuts and washers vibration dampers, coupling, alternator terminals, carbon brushes, springs, AVR's, exhaust pipes etc complete all as specified and as directed. Note :- Spares part shall be measured and paid separately under respective item of Sch A.
Change of Engine oil
Change of Engine oil filtter
Change of fuel filter
Change of Air Filter
Change of water separator
M& L for overhaluling of complete diesel engine of fwg capacities by opening top head, cleaning of engine of Generator and replace worned out parts of engine, checking and setting right the alignment of Engine and alternator, servicing of engine for smooth running, observing and setting correctly the unsual sound and color of smoke from exhaust (if any), reparing the leakage of fuel, lubricating oil and coolent, reparing of accessores drive, turbocharger and crankshaft, greasing, cleaning, removal of carbon depositss and other unwanted reminants, re-assembling the complete engine, fixing it is position and testisng on load etc complete all as specified and as directed.Note:- Overhauling of diesel engine shall be carried out through authorised service agency as approved by OEM and approved by GE. (ii) all unserviceable parts/ spare parts shall be paid under relevant BOQ item.
(a) 200/250/320 KVA Capacity
Replacement of following unserviceable parts / items from the engine / alternator of diesel engine driven generating set of 200 to 320 KVA capacity, 4/6-cyllinder Kirlosker / any approved make of following items etc complete all as specified and as directed.Note :Items required to be paid under supply only
Liner
Piston assy
Piston ring
Gasket Set
CR Bearing
Main Bearing
Thrust washer
Valve
Valve Seat
Valve Guide
Valve Seal
Lube oil Pump
Water Pump
O' Ring
Cooper Washer
V belt of suitable size
Crank Shaft
Head Assembaly Gaskit
M&L for Repair and replacement of complete wiring of existing panel board/ control panel board including replacement of Ameter, temprature meters,oil pressure gauge and ignition switch etc complete all as specified and as directed. for 40 KVA to 100 KVA DG set
M&L for Repair and replacement of complete wiring of existing panel board/ Control panel board including replacement of Ameter, temprature meters,oil pressure gauge and ignition switch etc complete all as specified and as directed. for 125 KVA to 320 KVA DG set
Draining out Lub oil from the oil pan assy of DG set cap upto 62.5 to 320 KVA and keeping aside for reuse and taking down oil pan assy complete from the engine block for cleaning the eitire oil pan with recommended solution and resembling the oil pan after replacement of gasket oil pan (Lub oil shall be examined for reuse by Engr in charge. However if the oil is found unsuitable for reuse, fresh oil shall be measured and paid separaetly under respective item etc complete all as specified and as directed.
Decoupling the alternator from the engine and taking out alternator 125 to 320 KVA from base plate and carrying the u/s alternator to local market incl dismantling the entire alternator taking out burnt enamelled copper wire ,preparing the stator for rewinding and rewinding the stator with super enamelled copper wire of superior quality incl application of insulating material, cotton tapes and suitable heat treatment ,transporting back to site and refixig to the engine from retrieved position etc complete all as specified and as directed.
Taking out carefully and repairing of fuel injection pump assembly complete from the engines of following capacity of DG sets including maintenance, servicing, replacement of valves, washers etc re-assembling calibration, setting for proper function, refixing and testing complete all as specified & directed.
(a) 7.5 to 30 KVA capacity
(b) 62.5 to 100 KVA capacity
(c ) 160 to 320 KVA Capacity
Taking down u/s dynamo/charging alternator12/ 24 volts from the engine and supply and fixing charging alternator 12/24 volts with necessary electrical connection with suitable cap flexible copper wire and sleeves etc complete all as specified and as directed.. Make : Lucas TVS or equivalent.
Taking down the turbo charger from the engine of DG set of 62.5/75/100/250 KVA after disconnection of all electrical connection and supply and fixing of the same on the position complete all as directed including elctric welding to the bracing of gaurd and the outer frame of turbo charger etc complete all as specified and as directed.
Dismantling & taking out carefully, reparing the self starter from the engine of following capacity of DG sets with opening up, cleaning / servicing and replacement of carbon brushes with holder and assembling back, refixing and testing etc complete all as specified and as directed.
(a) 7.5 to 30 KVA capacity
(b) 62.5 to 100 KVA capacity
(c ) 160 to 320 KVA Capacity
Taking out carefully for repairing the radiator assembly from the engine of following capacity of DG sets by disconnecting of inlet and outlet and over-hauling / servicing the radiator cleaning / removing blockage arresting leakage with necessary welding / brazzing as required and fixing back in its position for testing complete etc all as specified & directed.
(a) 7.5 to 30 KVA capacity
(b) 62.5 to 100 KVA capacity
(c ) 160 to 320 KVA Capacity
Dismantling and taking out the necessary connection carefully from MS fuel tank of any size / type of DG set by disconnecting of fuel pipes connections, draining out of fuel from the tank, cleaning & removing sediments, dirt etc from fuel tank and replacement of fuel pipe line with highly transparent PVC flexible threaded pipes of suitable size including painting of outer surface of fuel tank with synthetic enamel paint of one coat after cleaning, scrubbing the surfaces and writing the capacity of fuel tank and marking fuel level position with synthetic enamel paint for the following DG sets etc complete all as specified and as directed.
(a) 7.5 to 30 KVA capacity
(b) 62.5 to 100 KVA capacity
(c ) 160 to 250 KVA Capacity
(d ) 320 KVA capacity
Repair / maintenance of exhaust system including replacement of exhaust pipe, bracket with clamps, nut bolt and washer, exhaust manifold packing etc all as specified and directed by Engr - in - charge.
S & F in replacement battery terminal brass heavy duty complete etc all as specified and directed.
Supply & fixing in replacement of self starter motor suitable for 62.5/100/160 KVA DG set 12/24 Volt DC of same capacity / model / make / type and connection up of existing make etc complete all as specified and as directed. (TVS / Lucas/BOSCH or equivalent make as approved by GE)
Supply & Fixing in repair neon Indicator lamp for 230 volt, 50 Hz for indication to incoming and out going supply complete all as specified & directed.
S & F in repair /replacement of winding exciter assembly for DG Set of any capacity / Make all as manufacturer design including connection and testing etc complete all as specified and as directed.
S &F in replacement On load change over switch 4 pole, 250 Amp rating, 415 Volts, with steel enclosure and front handle type including connection lugs and testing etc complete all as specified and as directed. Make-Havells/standard or equIvalnet.
S & F in replacement On load change over switch 4 pole, 160 Amp rating, 415 Volts, with steel enclosure and front handle type including connection with lugs and testing etc complete all as specified and as directed. Make-Havells/standard or equIvalent.
S & F in replacement Manual change over switch 4 pole, 200 Amp rating, 415 Volts, with steel enclosure and Side handle operated type including connection with Lugs and testing complete etc all as specified and directed. Make-Havells/standard or equIvalent.
M&L for Replacement of old/UNSV Engine oil 20W 40/ 15 W 40, multi grade 2904C servo super for DG sets all type complete etc all as specified and directed. Make : Ashok leyland/Castrol/ Cummins/ Kirloskar/valvoline/or eq.
Supply and filling coolant for radiator in suitable container capacity complete etc all as specified and directed.
Supply and filling distilled water in suitable container capacity complete etc all as specified and directed.
S & F electric shock treatment chart coloured of size approximetely 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed.
S & F machinery maintenance chart coloured of size approximately 3 ft x 2 ft & 6 mm thick plywood with teak wood frame including covered with plastic laminated sheet complete etc all as specified and directed.
Repairing of electrical ON LOAD AMF panel of DG set of Capacity 62.5 KVA with repairing and replacement of minor parts of contractor, coil, timmer or other parts to smooth fuctioning of panel etc all as required and directed at site
Repairing of electrical ON LOAD AMF panel of DG set of Capacity up to 160 to 320 KVA with repairing and replacement of minor parts of contractor, coil, timmer or other parts to smooth fuctioning of panel etc all as required and directed at site
Dismantling / taking down of unserviceable turbo charger from following DG sets and transportation to authorised workshop of respective make / brand for repair / maintenance / balancing including replacement of required parts and make the same serviceable / functional complete etc all as specified & directed. (a) 62.5 KVA to 160 KVA Capacity
Supply & Fixing in replacement of coupling hub of alternator of existing size and make of capacity 62.5 to 160 KVA DG set complete etc all as specified & directed.
Supply and fix self starter 24 volt etc complete all as specified and as directed.
M&L for Repair/ Replacement of maintenance free starting battery 12 volts,180AH etc complete all as specified and as directed. MAKE : EXIDE/ AMARON / LUCAS
Repair / maintenance of battery charger of existing capacity 6 to 24 volts DC including replacement of unserviceable parts such as diodes, rotory switches, transformers etc of the same make & model complete etc all as directed.
Repair to self starter ,opening and repair to commutator replacement of carbon brush rewinding of stator coil and fixing self starter for 100 to 250 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge.
Supply & fixing in repair thermostate assembly for 250/200/125/75/62.5 KVA DG Sets complete all as specified & directed by Engineer-in-Charge.
Taking out old asbestos rope from exhaust silencer system, cleaning silencer pipe exhaust system wrapping up new asbestos rope on exhaust silencer system applying plaster of paris on complete exhaust system upto 320 KVA DG Set complete etc all as specified & directed by Engineer-in-Charge.
Taking out radiator assembly from the engine base frame for cleaning all chocked tubes of water cooler radiator asembly by applying suitable chemical for cleaning of chocked tubes & re-assembling after cleaning or brazing of tubes if required for 100 to 320 KVA capacity complete etc all as specified & directed by Engineer-in-Charge.
Material and Labour for dismantling of all existing connection and accessores of DG set of cap 100 to 250 KVA installed at AA RMS and shifting and installation with connection and testing at new location, including preparation of foundation for DG set with prior approval of foundation drawing by GE complete all as specified and directed by Engr-in-Charge. Note : (i) Tool and machinery required for dismantling and reconnection/ installation shall be deemed to be included in quoted rates. (ii) machinery/ plant required for lifting of DG set safety, transportation and re-installation shall be deemed to be included in quoted rates. (iii) No extra cost will be paid by the department in case of any damage and broken parts of DG sets during the transportaion and installation. (iv) Minor items required for fixing and installation shall be deemed to be included in the quoted rates (v) Cost of foundation is deemed to be included in unit rate quoted.
Material and Labour for dismantling and shifting of AMF/ LT panel with connected UG cables installed at existing location and installed at new location, Panel should be mounted on angle iron from and legs (Vertical height of legs not less than 30 CM except in PCC) made from angle of existing size, frame and legs duly spray painted internally and externally with two coats of synthetic enamel paint over a coat of red oxide primer legs grouted in PCC 1:3:6 type Br (using 40mm graded stone aggregate) complete including all connection with foundation completed all as specified and directed. Note:-Cost of foundation, tool and plant required for dismantling and installation is deemed to be included in quoted rates.
Attending electrical and mechanical complaints related to DG sets installed at AA RMS and allied units from complaint section/ JE E&M / Engr-in-Charge & attending the same within 2 hrs. This item is inclusive of all preliminary work like opening of connections, checking for supply, transportation of necessary tools and labour, assessing the nature of complaints, rectifying minor issues, removing air lock (if any), reconnecting the DG set back for proper functining. Note: Non compliance of attending breakdown & Complaint within 2 hrs after notification of the complaint will attract penalty @ 500/- per hour and maximum Rs 10,000/- per day per complaint shall be recovered from Contractor.s payment for each complaint so notified. Contractor shall deploy sufficient resources along with personnel safety equipments to keep all the DG sets functional.
Supply only in replacement oil pipe complete set for DG sets of capacity 7.5 KVA to 63 KVA complete all as specified and directed.
Supply only in replacement oil pipe complete set for DG sets of capacity 100 KVA to 250 KVA complete all as specified and directed.
Supply only in replacement diesel pipe complete set for DG sets of capacity 7.5 KVA to 63 KVA complete all as specified and directed.
Supply only in replacement diesel pipe complete set for DG sets of capacity 100 KVA to 250 KVA complete all as specified and directed.
Supply only in replacement rubber hose pipe complete set for DG sets of capacity 7.5 KVA to 63 KVA complete all as specified and directed.
Supply only in replacement rubber hose pipe complete set for DG sets of capacity 100 KVA to 320 KVA complete all as specified and directed.
Supply and fix in replacement oil/ diesel/ water pump complete set for DG sets of capacity 7.5 KVA to 63 KVA complete all as specified and directed.
Supply and fix in replacement oil/ diesel/ water pump complete set for DG sets of capacity 100 KVA to 320 KVA complete all as specified and directed.
Supply and fix in replacement complete radiator with fan driven assembly and other accessores including nut, bolts and connected minor parts suitable for DG set of Cap 100/125 KVA all as specified and directed by Engr-in-Charge.
Supply only in replacement HRC fuse 100 to 250 Amp including fixing arrangement complete all as specified and directed by Engr-in-Charge.
Supply only solenoid switch 12/24 volts with relay of existing make and capacity completed all as specified and directed.
Supply only relay 12/24 V DC completed all as specifed and directed all as specified and directed by Engr-in-charge.
S & F in replacement digital microprocessor controller of existing size, Make, Model and type, having complete features and fixing in control panel of DG sets of capacity upto 250 KVA complete all as specified and directed
Material and labour for painting of DG set, canopy and panel with synthetic enemel paint two coats by spray painting approved colour after scraping of old paint, cleaning of all rusted portion, surface including writing i.e MES No, capacity etc as per existing pattern etc complete all as specified and directed. Capacity of DG set 62.5 KVA to 250 KVA
Repair/ Replacement of maintenance free starting battery 12 volts,150 AH etc all as specified and directed by engineer in charge. MAKE : EXIDE/ AMARON / LUCAS
M & L for Repair/ maint of self starter 12 V DC by removing defective carbon bruses, Armature coil and takingout burnt materials and fixing the same all as specifed and directed by Engr-in-Charge.
M & L for Repair/ maint of self starter 24 V DC by removing defective carbon bruses, Armature coil and takingout burnt materials and fixing the same all as specifed and directed by Engr-in-Charge.
Supply & fixing in replacement of MCCB triple pole 200 Amps 35 KA, 415 volts complete etc all as specified & directed.
S&F in repair MCCB triple pole, 160 Amps, ultimate breaking cap 36 KA complete with motor break protection etc all as specified and directed.
S&F in repair MCCB four pole, 160 Amps, ultimate breaking cap 36 KA complete with motor break protection etc all as specified and directed.
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m depth for foundation of poles, cables etc, not exc 10 sqm on plan and getting out in soft/ loose soil including taking out brick protection etc. complete all as specified
Returning filling in trenches including spreading leveling watering and well ramming in layers not exceeding 25 cm thick all complete all as specified ans as directed.
Removing of excavated material (soil) not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point all complete all as specified ans as directed.
M&L for spread fine river sand in trenches complete all as specified ans as directed. Note: For measurement purpose, punned down thickness shall only be taken.
M&L for laying brick sub class 'B' old size burnt bricks for cable protection of size 230mmx115mmx75mm complete all as specified and as directed
Supply and fixing galvanised iron tubing 40 mm bore, light grade with all fittings for passing of under ground cable including taking down old pipe complete all as specified and as directed.Make:- Jindal/TATA/Prakashsurya
All as per item No 70.00 (here-in-before) but 50mm bore.
Material and labour for dismantling the servo volatge satbiliser in position upto capacity 400 KVA including taking down all incoming/ outgoing connection and lifting of core from the stabiliser for identification of fault and reassembling after rectification of fault. Note:- Spares reqd for replacement shall be paid under the respective item as under.
M & L for servicing of servo voltage stablizer including refresh the all connection, greasing, and following testing:- (i) Testing of oil (ii) testing of insulation resistance (ii) testing of leakage current and output voltage all as specified and directed by Engr in charege.( Note : if oil found unsv the oil replaced with fresh transformer oil and transformer oil shall be paid under the respective item as under)
S & F in replacement of defective electronic circuit card (PCB) and making electrical connection for servo voltage stablizer of any make and cap upto 400 KVA complete all as specified and as directed.
S & F in replacement of defective microproccessor based contro card for each phase and making electrical connection for servo voltage stablizer of any make and cap upto 400 KVA complete all as specified and as directed.
S & F in replacement of defective trigger transformer and making electrical connection for servo voltage stablizer of any make and cap upto 400 KVA complete all as specified and as directed.
S & F in replacement of defective servo motor 3 Kg torque and making electrical connection complete all as specified and as directed.
All as per item No 77.00 (here-in-before) but10 Kg torque
S & F in replacement of RC network for servo motor 3 Kg torque and making electrical connection complete all as specified and as directed.
All as per item No 79.00 (here-in-before) but 10 Kg torque
S & F in replacement of unserviceable carbon brush suitable for servo voltage stablizer of any make and cap upto 400 KVA complete all as specified and as directed and making all electrical connections etc complete all as specified and as directed.
S & F in replacement of Dimmerstat for servo voltage stablizer of any make and cap upto 100 KVA and making electrical connection etc complete all as specified and as directed.
All as per item No 82.00 (here-in-before) but dimmerstat cap 100-150 KVA .
All as per item No 82.00 (here-in-before) but dimmerstst cap 200-400 KVA
Repalcement of main transformer for servo voltage stablizer of any make and cap upto 400 KVA and making electrical connection etc complete all as specified and as directed.
Supply only transformer oil strength not less than 40 KV at 4mm gap etc complete all as specified and as directed.
Supply, laying & testing XLPE insulated screened PVC bedded galvanised steel strip or wire armoured, electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade of size 35 Sqmm 3.5 core incl taking out old unsv cable from trenches etc complete all as specified and as directed.
All as per item No 87.00 (here-in-before) but 50 sqmm 3.5 core size.
All as per item No 87.00 (here-in-before) 70 sqmm 3.5 core size.
M&L for PVC/XLPE insulated twin core aluminum stranded conductor round/flat cable size 10 Sqmm 1100 Volts grade served with an sheathing of PVC tape and overall PVC shaetehed in service connection suspended by insulating hangers not more than 1 mtr apart including 4mm GI suspension wire incl taking down old unsv cable etc complete all as specified and as directed.
All as per item No 90.00 (here-in-before) but 16 Sqmm
Material and Labour for Earthing complete with galvanized steel earth plate 60cm x 60cmx6mm thick electrode, burried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of earth plate at a depth not less than 1.5 mtrs below normal ground level, connected to GI wire 4mm size up to test point by means of nuts, bults, check nuts and washers of GI including excavation and earth work, PCC (1:3:6) type C1 pit 20mm dia GI pipe, medium grade watering pipe and 15 mm bore GI pipe, light grade for protection of earth wire, 50mm thick RCC 1:2:4 type B-1 cover reinforced with 8mm dia TMT bars @ 15cm C/C both ways and with handle made out of 10mm dia bars, funnel, wire mesh etc complete as shown in electrical Plate No 03 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion complete all as specified and directed
All as per item No 92.00 (here-in-before) but using galvanised iron strip 32x6mm as earthing lead.
Supply and Fixing of MCCB, 4 pole, 250 Amps, 415 V, 36 KA breaking capacity, thermal magnetic release type including taking down old one etc complete all as specified and as directed.
All as per item No 94.00 (here-in-before) but MCCB, 200 amps 4 pole.
All as per item No 94.00 (here-in-before) but MCCB,, 160 Amps 4 pole ,
All as per item No 94.00 (here-in-before) but MCCB, 125 Amps, 4 pole
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TPN/FP 40 to 100 AMP etc complete all as specified and as directed.
Supply and fixing 415V 10KA 'B' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the DB complete with connection testing and commissioning TP 63 Amp all as specified and directed by Engr-in-Charge.
Supply and fixing amp rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) of following poles and current carrying capacity in the MCB DB complete with connection testing and commissioning SPN 40 to 63 AMP all as specfied and directed by Engr-in-Charge.
M&L for Preparation of old painted surfaces of voltage stabiliser after scraping existing painted surfaces and priming with one coat of red oxide over two coats synthetic enamel paint etc complete all as specified and as directed.
Repair of Thyristor type NASU system (Make: CCR ) by providing OEM service engineer including repairing/replacing of defective CCRs by identifying the fault, replacement of defective PCBs and other components and complete checking Thyristor type NASU capacity 4KW Note: (i) All the components reqd for repairing to make ther CCR serviceable shall be provided by the contractor and measured separately.. (ii) The CCR shall be repaired and serviced by OEMs Rep/ his auth rep only.
Calibration of Thyristor type NASU system (Make: CCR ) by providing OEM service engineer including servicing complete all as directed . Note: (i) Calibration and servicing of CCR will be carried out quarterly. (ii) Each CCR test will be carried out and calibration report will be submitted to department. (iii) The CCR shall be calibrated and serviced by OEMs Rep/ his auth rep only. (iv) Servicing includes dusting, cleaning, checking of all conection and making the connection healty.
Supply of Main contract card including RMS to DC converter card and taking out unsv card etc complete all as specified and as directed.
Supply of Over current trip and taking out unsv card etc complete all as specified and as directed.
Supply of Relay card-02 Nos and taking out unsv card etc complete all as specified and as directed.
Supply of TTM card and taking out unsv card etc complete all as specified and as directed.
Supply of 24 Volt DC plug in type relay and taking out unsv relay etc complete all as specified and as directed.
Supply of 48 volt DC plug in type relay suitable for 11 pin socket and taking out unsv relay etc complete all as specified and as directed.
Supply of 240 volt AC plug in type relay and taking out unsv relay etc complete all as specified and as directed.
Supply of of thyristor 65 RK 160 and taking out unsv part etc complete all as specified and as directed.
Supply of HRC fuse link 32 Amps Set of 02 Nos and taking out unsv fuse etc complete all as specified and as directed.
Supply of HRC fuse link 4 Amp and taking out unsv fuse etc complete all as specified and as directed.
Supply of 02 pole 8 way brilliancy switch Rotary , MB type and taking out unsv switch etc complete all as specified and as directed.
Supply of Power transistors MJ 11016 (Set of 02 Nos) and taking out unsv part etc complete all as specified and as directed.
Supply of 30 Amp conductor (Mode: 3TF33) suitable for 4Kwh NASU and taking out unsv part etc complete all as specified and as directed.
supply of high speed semi conductor protection fuse GSB 50 suitable for 4 KW CCR etc complete all as specified and as directed.
supply and fix digital true RMS meter 10 amp for CCR etc complete all as specified and as directed.
Supply and fix digital true meter 100 micor amp DC coil moving meter (96x 96) etc complete all as specified and as directed.
Supply and fix lighting arrestor 4.5 KV grade suitable for 4 KW CCR etc complete all as specified and as directed.
Supply and fix LED lamp Green, yellow and red as per existing suitable for 4 KW CCR etc complete all as specified and as directed.
PERFECT BUILDERS AND SUPPLIERS
Rameshwar Prasad
P K ELECTRICAL
commercial enterprises
VAISHNO ASSOCIATES
M/S Lucky Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .