Executive Engineer Asansol Mech Divn PHE Dte
Janasasthya Karigori Bhaban, Sen-Releigh Road, Opp ESI Hospital, Asansol - 05
Repairing of HT VCB, Dehydration of Transformer oil including other allied work at Head Works site under Kendra Kottahamdihi Water Supply Scheme.
2022_PHED_396083_9
WBPHE /EE/AMD/NIT 15e / 2022-2023
Open Tender
Electrical Work/ Equipment
Item Wise
7 days
Kendra Khottamdihi
Please refer Tender documents.
3 documents required · 3 mandatory
₹5,000
13 Oct 2022
18 Aug 2022
5 Sept 2022
18 Aug 2022
2 Sept 2022
18 Aug 2022
Amount
Repairing and Servicing of 11 KV VCB panel:- a) Isolate and withdrawal of Breaker. b) Opening of Spout, supporting insulator, PT, Spout, Tank Bushing. c) Repalcement rusted nut, bolts. d) Refitting of the above spares. e) Thorough cleaning of Panels. f) All metering circuit connection to be checked and rectified. g) All protection circuit to be checked and rectified. h) All overcurrent and Earth fault relay tripping test to be done. i) Control wiring for indication circuit and alarm circuit to be done. j) Bus-Bar, CT, PT, Cable needs to be checked thoroughly and tested. k) Blocking of Cable hole entry. l) Treatment of HT Cables (i.e. cleaning by thinner, heating by blower to free moisture then voltage insulation improving.) m) Opening of arm. moving contact, cleaning of carbon area.
Supply delivery and fitting fixing of indoor type heatshrinkable termination kits for 3 core 185 sq.mm 11 KV (E) XLPE Al. Ar Cable. Make-M seal/Raychem/Denson/Other Approved Make
Overhauling and Servicing of 630 Amps ACB after opening the breaker and servicing of the existing serviceable spares unit and decarbonizes the all contact with supply of all required materials by engaging skilled service engineer as per direction of EIC.
Supply delivery of Transformer Oil as per IS-335. Make-Power Oil
Supply delivery and fitting fixing of CBI Bushing with all fittings. Make-AEG
Disconnection of Transformer from H.T. Side & L.T. Side with proper protection as per direction of EIC. (For Both 315 KVA Transformer )
Drain out the old transformer oil from the Transformer with proper protection up to the Bushing level as per direction of EIC. (For Both 315 KVA Transformer )
Removal of top cover and inspection cover after removal of conservator tank, bucholze relay part by part after loosening of all the nuts & bolts for detecting any defects as per direction of EIC. (For Both 315 KVA Transformer)
Dismantling of HT & LT Bushing including Cleaning and changing of Conical Washers of all the Bushings etc. (For Both 315 KVA)
Supply and fixing of new Gasket for both 315 KVA Transformer including Tank Top Cover / inspection Cover / HV & LV / Bushing etc.
Placing the top cover and inspection cover and bucholze relay, conservator tank in proper position and tightening of Nuts and Bolts after clean up the surface sludge of core & coil assembly with hot oil through filter machine for315 KVA Transformers as per direction of EIC. (For Both 315 KVA Transformer)
Filling the transformer oil through filter machine by old oil and new supplied oil after filtration to the 315 KVA Transformer engaging skilled and unskilled personal for increasing I.R. value as per direction including hire charges of oil filter machine and oil testing equipment and gen. set and carriage the same from Asansol. To Kendra kottahamdihi H/W site and back as per direction of EIC. (For Both 315 KVA Transformer )
Making necessary connection in H.T. & L.T.side and Testing of the transformer all complete as per direction of EIC. (For Both 315 KVA Transformer)
Supply delivery of following Starter Spares at site:-
Contact Element,SPST-NC 10A, Make:-Teknic
Contact block SPST-NO 10A, Make:-Teknic
Earth Fault monitoring relay, Cat No.- 7UGO861-1BU20. Make-Siemens
On delay timer 3 sec -30 hrs, 240 VAC/24 V DC. Make: - GIC
150A, 3 Pole Power contactor AX150-30 230V-Aux Make : -ABB
Flush head type Push button, for Pump No.-1. Make-Siemens/L&T/Other Approved make
25 sqmm PVC insulated single core Industrial Flexible Cable. Make-Gloster/Havells/Polycab/Mescab/Other Approved make.
Fitting fixing of the above supplied spare after dismantling of the damaged one in the existing place including making necessary control wiring.
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection. Make-Havells
i) 63A 4Pole MCB
ii) 16A SP MCB
iii) 32A DP MCB
Laying of one No. cable 300 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying only Cable of 300 sqmm X 3½ core through existing open masonary trench.
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials : i) 3½ core 300 sqmm cable.
Add. GST@12%
Add. Cess@1%
INDUSTRIAL ELECTRICAL CORPORATION
M/S. Sajahan Chowdhury
ELECTRICAL AND MECHANICAL ENGINEERING CORPORATION
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .