Loading…
Loading…
Tender Value
₹4.7 Cr
EMD Value
₹3.8 L
Closing Date
13 Feb 2026, 2:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
S AND T
14 conditions · 2 needing a document upload
For works amounting Rs.50 lakhs and above: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of 'total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i) Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii) Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii) One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Defination of Similar Work :- Panel Interlocking or Route Relay Interlocking or Electronic Interlocking or IBH or Automatic Signalling or LC gate Interlocking or AFTC or SSDAC or MSDAC or HASSDAC or BPAC.
9 conditions · 2 needing a document upload
Demand for the Financial Criteria, Association of Railway Officers, List of Arbitration cases, Court cases and Mandate for NEFT are to be uploaded with a scanned copy duly filled in and signed as per annexure no. IV, V, VI, VII, VIII, IX, XI, VIA, VIB, VI and Annexure-V & Annexure-V(A) of GCC-2022 respectively. These Annexures are available in View Document menu at Home page and is downloadable. The details of the uploaded documents should be produced whenever demanded for verification on written request at any point of time of the tender and contract within 7 days.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tenderers are requested to go through the following documents which are available in upload/View Documents in Home page of IREPS portal for works tenders before submitting the e-tender. 1.General Instruction for E-Tenders on works contract--Chapter- I 2.Special Condition-General- Chapter-II
Opening of e-tender : 1. The e-tenders will be opened online using the IREPS portal anytime after tender closing time. No representative is required to be present for opening of e-tender and taking notes of rates quoted and ranking as the complete details of rates etc. of all the bidders shall be available to the bidders through the website after the opening of the tender. 2. The earnest money cost is to be paid through online banking facilities through the online portal and by giving the other details online on website www.ireps.gov.in. Note: For more details refer to Cl: 4 & 12 of General Instruction-Chapter-I for Submission of EMD, Cost of Tender Document and opening of e- tender.
Asansol Division: Replacement of Axle counter in station sectionon age cum condition basis.
37-SDSTE-ASN-2025-26~ER
37-SDSTE-ASN-2025-26
Open
Works - General
18 Months
Paschim Bardhaman, West Bengal
₹0
₹3.8 L
13 Feb 2026
22 Jan 2026
30 Jan 2026
151 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 4,66,63,498.78 | ||
| — | 40.00 | — | — | ||
| Supply, Transportation, Installation, Testing and Commissioning of Multi Section Digital Axle Counter (MSDAC) for mentioned detection Point by the purchaser & Track Section as per SIP uploaded with the tender, complete with all accessories, cable required with each track device & Card viz., Axle Detectors, Track Side Electronics/DAC field units, Central Evaluator (Central Evaluator unit should be housed in a pre-fabricated Rack to be supplied along with the system), Reset unit, Relay unit, Event logger & Diagnostic terminals etc. required for different Detection Points & Track Sections as per RDSO Specification No. RDSO/SPN/176/2013, Ver.3 or latest as per annexure -A,B,C in Annexure-1. Inspection: RDSO. | — | — | — | 1,37,02,320 | |
| — | 8.00 | — | — | ||
| Supply of IPS DC-DC converter 24-32V DC, 5 Amp /10 Amp or 60-66 V DC, 5 Amp or 60-100V DC,1 Amp/3 Amp/5 Amp as per specification No. RDSO/SPN/165/2012, version- 3.0 or latest. Make: M/s. Statcon Ltd./ M/s. HBL Ltd./M/s. Amara Raja Ltd. Or Other RDSO approved make, compatible for the IPS make specified by Purchaser. Quantity of DC-DC Converter as per make and as per voltage/current rating will be specified by Rly. Engineer before inspection process for supply. Inspection: RDSO. | — | — | — | 1,94,808 | |
| — | 1.00 | — | — | ||
| Supply of cable termination rack as per DRG.NO. S&T/C- 17/2001 OR latest with screw less disconnect type connectors (Wago / Phoenix/Similar), scaffolding materials, ladder for supporting outdoor cable, wire guide, NDT fuse complete with other necessary hardware as per requirements of railway & erection materials. Terminals, fuse, Wires to be procured from RDSO's approved firm only and to be inspected by RDSO. Inspection of CTR: Consignee | — | — | — | 44,924 | |
| — | 1.00 | — | — | ||
| Installation, erection, commissioning of CTR as per instruction of Rly site engineer and as per Drg no. S&T/C-19/2001orlatest with fixing of scaffolding materials, terminals, fuse block, wire guide, ladder guide for supporting outdoor cables, wires. This includes termination of outdoor cable on terminals with proper lugs, number sleeves as per diagram and laying, dressing of cables, wires including earthing of cable armours properly. This also includes lettering/numbering of terminals for circuit used in brief. | — | — | — | 5,790 | |
| — | 25.00 | — | — | ||
| Excavation of trench as per cable route plan in all kinds of soil (1.2 mtr. Depth and 0.3 mtr. to 0.6 mtr width at bottom) and refilling of the trench without bricks and final back filling, ramming and consolidation of soil as well as the disposal of the soil, if any. Note:- Payment will be made as per actual work done on pro-rata basis, if the required depth is not available at site. If the depth of trench is not uniform in a span of 100 M or shorter lengths if site condition demands along the cable run minimum depth will be taken for that particular stretch for payment. Prior permission should be taken from field Officer before laying of cable if the depth of trenching is less than 1 mtr. and duly mentioning location, length etc. in site register. This work includes clearing of route from bushes etc. The work shall be done as per the extant practice on Eastern Railway and instructions of Railway Engineer at site. For all trenches from distant signal to home signal and to relay room, the minimum headway above the uppermost cable in the trench should be 600mm. If due to a large no. of cables headway is not available, 4" of 1:2:4 concreting should be done. | — | — | — | 33,31,985.25 | |
| — | 105.00 | — | — | ||
| Laying of S&T cable of various core sizes as per cable route and cable core plan approved by Railway and meggering of all main & Tail cables. The work to be done as per instruction of Rly. site engineer. Note: All materials (except cable) required for the execution of the work shall be supplied by the contractor. | — | — | — | 9,33,446.85 | |
| — | 500.00 | — | — | ||
| Excavation of trench (1.2 mtr. depth from rail flange/road level and 0.3 mtr. to 0.6 mtr. wide, earth work and backfilling after placing DWC/RCC/GI pipe ( placing of DWC/RCC/GI pipe covered separately) , re-instatement of track while track crossing for laying of cables. The ballast disturbed to be screened and dressed and road tarred immediately. This work to be done as per instruction of Rly. Site engineer. All materials (except cable, DWC/RCC/GI Pipe) required for the execution of the work shall be supplied by the contractor. Note: If required depth can not be achieved at particular location, then alternative location to be selected as per instruction of Rly. site engineer | — | — | — | 68,210 | |
| — | 500.00 | — | — | ||
| Supply of Double Wall Corrugated (DWC)-HDPE pipe/duct of size 200 mm outer dia, & 175 mm inner dia. It includes supply of Double Wall Corrugated -HDPE pipe/duct as per RDSO Specn.No. RDSO/SPN/ 204/2011 (version 1.1) or latest and conforming to ISI Spec. No.IS:14930, Part- II. (The manufacturers, suppliers must produce valid IS license and should be certified under ISO 9000 and shall submit copy of certificate). One of the following coupling arrangements should also be supplied with each pipe as per the site requirement.1) Suitable snap fit coupler with rubber O- Ring 2) Spacers 3) Tees 4) Bend,5) End-cap. DWC pipe shall be marked at every 1 mtr length in such a way that manufacturer's name, vendor name and year of manufacture can be easily identified. Inspection: Consignee | — | — | — | 1,98,500 | |
| — | 300.00 | — | — | ||
| Placing of DWC HDPE pipes along with collars in trenches at places near track and road, crossings, platform cuttings etc. | — | — | — | 9,300 | |
| — | 300.00 | — | — | ||
| Boring under Road/Railway track for crossing of s&t cables. Boring to be done for crossing road/rail at minimum 1 mtr. depth & after boring min. 4" dia-meter G.I pipes are to be inserted & cables to be laid through the pipes. GI pipe, cable will be supplied by Rly. For this work, tools , accessories, required materials to be supplied by contractor. | — | — | — | 1,60,506 | |
| — | 600.00 | — | — | ||
| Supply of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 or Latest with socket & coupling. It includes supply of all material required for fixing arrangement. Contractor will also supply flexible/corrugated HDPE pipe at the end of GI pipe to protect the cables from sharp edges and sudden bends. Inspection: Consignee | — | — | — | 4,57,200 | |
| — | 600.00 | — | — | ||
| : Laying & Fixing of Medium class GI pipes 100 mm dia (4.5 mm thickness) as per IS 1239 (Part 1): 2004 with socket & coupling on culverts bridges or at any other locations as decided by Site Engineer. It includes installation of all material required for fixing arrangement. Contractor will install flexible/corrugated HDPE pipe at the end of GI pipe along with any masonry work(if required) to protect the cables from sharp edges and sudden bends. | — | — | — | 58,800 | |
| — | 2000.00 | — | — | ||
| Transportation of HDD machine with accessories including handling of stores materials, preparation of site and boring (boring size upto 175mm) for laying of (i) three (03) nos. Of 40mm HDPE pipes & one (1) 50mm HDPE pipe or as per site engineer for placing and for crossing of signalling /telecom. Cable through HDPE pipe at bridges/ culverts/ track crossing/ pucca road crossing, boring trench shall be minimum 03 (three) meter below the river bed and 01(one) meter below the track/road/pucca road crossing area. This includes supply of permanently lubricated HDPE telecom. Ducts (i) 40mm/33mm & 50mm/42mm (with chord) as per RDSO SPEC. NO. RDSO/SPN/TC/45/2013 REV. 2.0 with latest amendments or as per specification no. TEC GR. NO. G/CDS-08/02, NOV.2004 OR LATEST. For each km. of HDPE duct the following items are to be supplied (a) end plugs - 02 nos. (b) cable sealing plugs - 02 nos. (c) plastic couplers slip fit / push fit type - 02 nos. (d) end plugs to be provided along with drum - 02 nos. Note: - cost of fuel and all other items which will be required for laying of cable through HDPE pipe. The work shall be executed as per site engineer. | — | — | — | 35,16,000 | |
| — | 10000.00 | — | — | ||
| Supply of Half Round RCC pipes & collars of 300 mm outer dia & 250 mm internal dia (2-meter-long) along with collars as per IS No. 458/2003 of NP type. Inspection : RITES | — | — | — | 67,90,000 | |
| — | 20000.00 | — | — | ||
| Laying of half round RCC pipe after laying the cables in the trenches. (Cable laying is covered separately). | — | — | — | 4,40,000 | |
| — | 300.00 | — | — | ||
| Supply and fixing of RCC Cable Route Marker as per ER Drawing No. SI- S&T/1/2024(Sheet-1) and ER technical policy circular no. 108. Inspection: Consignee | — | — | — | 1,25,100 | |
| — | 25.00 | — | — | ||
| Supply of full size apparatus case(Large) (as per DRAWING NO.RDSO/S-11500. This includes supply of location box (GKP type)with 'E' type lock & key, fitted on location door on both side, E Type lock (ward No will be specified by Engineer-in Charge) as per RDSO Drg. No. SA 3376 and Key to Drg .No. 3377 as per RDSO drawing No. RDSO/S-11500. Inspection: Consignee | — | — | — | 3,47,900 | |
| — | 25.00 | — | — | ||
| Casting, concreting, curing and plastering of concrete foundation for full size location box (GKP type)with Cement, sand, Stone Chips in the ratio 1:3:6 and erection of full size apparatus case(location box) as per Drg. NO.S&T/C-6/98(NKG). All materials required for this purpose including holding down bolts, nuts, washer, concreting materials etc. are to be supplied by the contractor. Materials to be inspected by Rly. Site Engineer and the work will be executed as per instruction of Rly. site engineer. Note:-location boxes to be painted with anti corrosive paints ( Asian paint/Berger/Shalimar) as per IS:-9862-1981, one and half feet from the bottom, on all surfaces-both inside and outside. This also includes bottom of apparatus cases filled with sand and the outside covered with masonry work and neat cement plastering. | — | — | — | 88,300 | |
| — | 25.00 | — | — | ||
| Fixing of slotted angle, Bakelite strip, hylam sheet, fixing and wiring of terminals, relays, fuse with base etc. and fixing of shelves in Full size steel Apparatus cases(location box) with termination, dressing & bunching of cables/wires, earthling of cables and wiring with necessary lettering as required including supply of wires, slotted angles, ferrules for marking, misc. materials as required per location box. All materials except relay, terminal strips, bakelite strip, fuses with base, charger, D type resistance, B type choke, SSDAC equipment, surge arrester, battery and hardwood shelves to be supplied by the contractor. Wires to be procured from RDSO approved firm and to be inspected by consignee. This includes sand filling and plastering over sand filling. NOTE: All locations to be provided with lamp/holder, switch for lighting as desired by Site Engineer. This should include all Terminations of Cable complete. Cable conductors are to be terminated with proper lugs and required bussbar and other terminals to be supplied by the contractor. | — | — | — | 1,20,750 | |
| — | 10.00 | — | — | ||
| Alteration/modification in the existing location boxes (full size),fixing of equipment's, cable insertion, termination, wiring, testing & commissioning, two coat painting, lettering to suit the circuits as per approved wiring diagrams. This includes filling with sand and plastering the same. | — | — | — | 27,820 | |
| — | 500.00 | — | — | ||
| Supply of PBT ARA terminal 6 WAY as per DRG.NO.23756, ALT-3. and as per IRS SPECN.NO. IRS: S-75-2006(REV-2) or latest.Inspection: RDSO. | — | — | — | 2,42,500 | |
| — | 5.00 | — | — | ||
| Supply of PVC insulated multi strand, single core copper conductor of size 16/0.2 mm (0.5sqmm) as per IS 694:2010 and RDSO Specn. No. IRS: S-76/89 (Amnd-3) or latest. Each coil should be of 100/200/500 meters length. Color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO | — | — | — | 38,345 | |
| — | 2000.00 | — | — | ||
| : Supply of Disconnect Terminal Block, Screw less type, 4-wire front entry (Two in-put & Two out-put) as per RDSO Spec. No. RDSO/SPN/189/2004 Ver. 3.0 with latest amendment. The colour will be decided by Engineer - in -Charge. (Preferably In Blue, Red & Grey Colors in the ratio of 1:2:3).Inspection: RDSO | — | — | — | 1,12,000 | |
| — | 200.00 | — | — | ||
| Supply of end plate 2.5 mm / 0.91 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 2,000 | |
| — | 150.00 | — | — | ||
| Supply of end stopper 10mm/0.0394 in width to use with above Disconnect type Terminal Block. Inspection: Consignee | — | — | — | 1,500 | |
| — | 500.00 | — | — | ||
| Supply of shorting link ( jumper) compatible to disconnect type terminal. Inspection: Consignee. | — | — | — | 1,000 | |
| — | 150.00 | — | — | ||
| Supply of steel Carrier Rails of size 35mm x 7.5mm, 1mm/0.039in thickness un- slotted type for placing disconnect type terminals. .Inspection: Consignee | — | — | — | 16,350 | |
| — | 2000.00 | — | — | ||
| Termination of Outdoor Cables (Main Cables /tail cables) at both ends in location boxes, cable termination rack in relay room, station building, generator room etc. The item includes dressing of cables and wires with dressing threads as per standard practice. All material required for this item will be supplied by contractor. The outdoor cable shall be terminated in Relay Room, DG Room, ASM Room etc under supervision and instructions issued by Engr. incharge of the work. Inspection: Consignee | — | — | — | 18,000 | |
| — | 50.00 | — | — | ||
| Supply of paper base hylam sheet 12 mm thick. Inspection: consignee. | — | — | — | 2,68,500 | |
| — | 300.00 | — | — | ||
| Cutting of platform / floor surface/ concrete surface for a depth of 20 cm & width of 10 cm & refilling / reconditioning/repairing the surface after laying of pipe, cable. Cutting to be done with machine in proper manner & restore the same as before. | — | — | — | 71,598 | |
| — | 6.00 | — | — | ||
| Masonry job for Cutting the wall for insertion of cable along with re instatement, repairing of wall with brick, sand and cement and painting/whitewashing after laying of cables as per instruction of site engineer. All masonry items and required items to be supplied by the firm. | — | — | — | 1,758.12 | |
| — | 25.00 | — | — | ||
| Supply of Earth Electrodes mild steel galvanized , light class , as per Specification No. IS:1239(Part-I)-1979 and as per PCSTE/ER's Drg. No. SI/TYP/0097 dated 25.03.25. Earth electrode pipe should be 3 mm thick, 50 mm dia. and perforated ( staggered) with 5 mm dia holes 2 nos. per 305 mm length alongwith supply of CI threaded cap, nuts, bolts, other materials as mentioned in Drg. No. SI/TYP/0097 . Earth electrode pipe to be galvanised after drilling and fabrication. Inspection: Consignee. | — | — | — | 37,400 | |
| — | 25.00 | — | — | ||
| Supply of MS FLAT (SPEC. NO. 226 STD or latest) of size 35 mm x 6 mm with length 5 mtr with holes of 12 mm dia at both ends Inspection :consignee. | — | — | — | 22,775 | |
| — | 25.00 | — | — | ||
| Fixing of earth electrode including laying and installation of MS flat of size 35 mm x 6 mm with length 5 mtr or cable for apparatus cases, signal post & other equipment as per guideline mentioned in PCSTE/ER'S DRG. NO. SI/TYP/0097 with provision of alternate layers of charcoal /coal and salt . Provision for fixing MS flat at apparatus cases/ signal post/other equipment should be made by the firm at site. Full threaded bolts of 10 mm dia and length 40 mm should be welded in the apparatus cases in such way that the MS flat at apparatus case end can be fixed from outside or from inside. Welding arrangement with accessories and welding materials should be arranged by the contractor for fixing of bolts at equipment end where required as per instruction of site engineer. As per requirement MS flat may be joined by welding to increase length or to be cut & drill hole to shorten the length. All hardware and other miscellaneous materials required for installation to be supplied by the contractor | — | — | — | 29,025 | |
| — | 25.00 | — | — | ||
| Provision of cement concrete enclosure of size 450 mm x 450 mm x 300 mm and 75 mm thick for earth electrodes as per PCSTE/ER'S DRG. NO. SI/TYP/0097 dated 25.03.25. This includes supply of all materials by the contractor duly inspected by consignee. | — | — | — | 14,275 | |
| — | 10.00 | — | — | ||
| Supply of Digital Multimeter of Fluke 287 Industrial or Similar/ superior True RMS with temperature, Analog bar graph, Digital display, Backlight, 1000V AC/DC, measure up to 10A, 20A for up to 30 second. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 4,40,640 | |
| — | 10.00 | — | — | ||
| Supply of Professional AC/DC clamp meter 3 ¾ digit, true RMS measurement, For Measurement of DC/AC currents up to 1000A, Voltage up to 600V, resistance up to 40 M and frequency up to 1 MHz with set of leads & carrying case. Model - DCM 39A or equivalent/ higher make Motwane / Stanlay /Fluke/Megger. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 2,87,520 | |
| — | 8.00 | — | — | ||
| Supply of Handheld Digital Earth Clamp Tester for clamp on earth/ground resistance measurement up to 1000 ohms. Accuracy 0.1 - 0.99 : 1%, 1 - 49 : 1.5% Also measure current leakage up to 20A. No spines required for measurement Model - DECT-2 or equivalent / higher version make Motwane/Stanlay/Fluke/Megger. Item to be placed for inspection after successful demonstration and Approval of Railway. Inspection: RITES | — | — | — | 7,59,680 | |
| — | 4.00 | — | — | ||
| Supply of electronic Cable route tracer/locator with underground cable and pipe locating receiver and cable avoidance tool that provide location of armored OFC, signalling and telecom, power cable etc. make: C Scope Stanley/3M Dynatel, model: DXL-4 DBG /2273M-iD 30 or Similar/ superior. Item to be polaced for inspection after successful demonstration and Approval of Railway. Inspection: RITES | — | — | — | 16,42,872 | |
| — | 10.00 | — | — | ||
| Supply of Road Measuring Cycle, made of Aluminum with 05-digit counter, foldable with bag. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 43,000 | |
| — | 10.00 | — | — | ||
| Supply of Digital Cable Insulation Tester for measurement of cable insulation resistance with auto range 0-500 V DC. Motwani or from any reputed make. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 86,920 | |
| — | 6.00 | — | — | ||
| Supply of Cable Fault Locater to localize the faults of underground cables. Aplab make (Model No.3049) OR C Scope Stanley make (Model TS- 90) or Similar/ superior from any reputed make. It also includes supply of all accessories required to localize faults of underground cables. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 3,51,474 | |
| — | 10.00 | — | — | ||
| Supply of Digital Earth Resistance Tester for measurement of earth resistance with 3.5 digital LCD, 12.5 mm screen segment and Range -0.5 Ohms to 500 Ohms. WACO or Similar make. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee. | — | — | — | 87,610 | |
| — | 15.00 | — | — | ||
| Supply of Insulation tester 100V, 100 M with lead cables, Analog Display, metal body hand driven. Make: Waco/Nippen/Fluke/Motwane or better. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 45,300 | |
| — | 10.00 | — | — | ||
| Supply of Insulation tester 500V, 100 M complete in leather case and testing probes (Hand Generating Type). Make: Waco-WI 104/Nippen/Fluke/ Motwane or better. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 32,990 | |
| — | 4.00 | — | — | ||
| Supply of Quick Clean Dx Vacuum Cleaner with 1200 Watts Powerful Suction Control 3 phase with reusable dust Bags and alongwith all accessories as per OEM. Make: Eureka Forbes. Item to be supplied after successful demonstration and Approval of Railway. Inspection: Consignee | — | — | — | 17,976 | |
| Man-Days | 400.00 | — | — | ||
| Supply of labour ( helper) for various S&T indoor , outdoor works, taking measurement of signalling gears, assistance to Railway Official in various field works, by acting as look out men, chowkidars, patrolmen, etc and to assist in office work as per instruction of engineer- in-charge or his representative. For safety related works, competency will be ensured by the inspector concerned. The inspector concerned will maintain proper record of supply of labourers by the agency. | — | — | — | 2,04,444 | |
| — | 150.00 | — | — | ||
| Rapid maintenance & repairing of laid cable/existing cables / exposed cables / cut cables during site work as per instruction of site engineer. The maintenance & repairing gang should have their own maintenance & repairing tools and measuring instruments and they should comprises of (1) one highly skilled staff (ii) one skilled staff & (iii) two un-skilled staff for this purpose of work. All materials for the maintenance & repairing of laid cable/existing cables / exposed cables / cut cables will be supplied by railways. This also includes various S&T related field works to be done by the rapid maintenance & repairing gang as per instruction of Railway site Engineer. | — | — | — | 4,42,393.5 | |
| — | 16.00 | — | — | ||
| Supply of RESET BOX of G G Tronics make high Availability Single Section Digital Axle Counter Systems (HASSDAC) as per Spec.No RDSO/SPN /177/2012 Ver.-3 . Inspection: RDSO | — | — | — | 5,85,242.24 | |
| — | 16.00 | — | — | ||
| Supply of 21 KHz /25 KHz Rx coil Assembly of G G Tronic make HASSDAC as per RDSO Spec. No. RDSO/SPN/177/2012 .Ver.-3 . Inspection : RDSO | — | — | — | 7,55,181.12 | |
| — | 16.00 | — | — | ||
| Supply of 21 KHZ/25KHZ TX coils assembly of G.G.Tronics make HASSDAC as per RDSO Specification No. RDSO/SPN/177/2012 Ver-3. Inspection : RDSO | — | — | — | 7,55,181.12 | |
| — | 16.00 | — | — | ||
| Supply of PD1 / PD2 (21KHZ/25KHZ) card of GG Tronics make HASSDAC as per RDSO spec. No. RDSO/SPN/177/2012 (Ver. 3) or latest. Note : Supply to be done as 8 nos. PD1 cards and 8 nos. PD2 cards. Inspection : RDSO | — | — | — | 6,97,936.96 | |
| — | 16.00 | — | — | ||
| Supply of CPU1 and CPU2 cards of G G Tronics make SSDAC/HASSDAC as per RDSO spec. No. RDSO/SPN/177/2012 (Ver. 3.0) or latest. Note : Supply to be done as 8 nos. CPU1 cards and 8 nos. CPUM2 cards. Inspection : RDSO | — | — | — | 10,31,508.8 | |
| — | 16.00 | — | — | ||
| Supply of COM1 and COM2 Communication Card of G G Tronics make SSDAC/HASSDAC as per RDSO spec. No. RDSO/SPN/177/2012 (Ver. 3) or latest. Note:Note : Supply to be done as 8 nos. COM1 cards and 8 nos. COM2 cards. inspection: RDSO | — | — | — | 4,64,315.84 | |
| — | 16.00 | — | — | ||
| Supply of RD-1/ RD2 Card for HASSDAC of GGTRONICS make as per RDSO Spec RDSO/SPN/177/2012(Ver.3) or latest. Note : Supply to be done as 8 nos. RD1 cards and 8 nos. RD2 cards. Inspection : RDSO | — | — | — | 4,06,336.96 | |
| — | 16.00 | — | — | ||
| Supply Event Logger Card of HASSDAC of GGTRONICS make as per RDSO Spec RDSO/SPN/177/2012(Ver.3) or latest. Inspection : RDSO | — | — | — | 9,34,061.28 | |
| — | 16.00 | — | — | ||
| Supply of DC-DC Convertor Card Suitable for HASSDAC of GGTRONICS make as per RDSO Spec RDSO/SPN/177/2012(Ver.3) or latest. Inspection: RDSO | — | — | — | 4,90,144.32 | |
| — | 2.00 | — | — | ||
| Supply of Office table with laminated top with three drawers on left hand side and one locker on the right-hand side. Olive brown with duplicate keys. Make: Godrej Model T-9 (136.5 cmX68cmX 75cm) or Similar of reputed brand. Inspection: Consignee | — | — | — | 25,772 | |
| — | 8.00 | — | — | ||
| Supply of Office Chair make Godrej CH-7B or similar of reputed brand. Inspection: Consignee | — | — | — | 23,216 | |
| — | 2.00 | — | — | ||
| Supply of Office Revolving Chair Godrej Make Model No.9U02R Bravo or Similar of reputed brand. Inspection: Consignee | — | — | — | 18,064 | |
| — | 2.00 | — | — | ||
| Supply of Steel Plain Almirah with 4 adjustable slaves Size: 1980mm height, 915 mm width and 485 mm depth. Make: Godrej Storewel Plain Large or Similar of reputed brand. Inspection: Consignee | — | — | — | 34,326 | |
| — | 6.00 | — | — | ||
| Supply of basic material to construct unit maintenance free earth as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Necessary testing certificate of UL, IEC to be produced. It consist of following: (a) Copper bonded steel electrode of 3.0 m long, 17.2 mm dia with copper bonding thickness of minimum macrons and UL listed and marked = 1 no. (b) Earth enhancement material supplied in sealed bags of minimum 10 kg = 3 nos. (c) Copper strip of 150x25x6 mm, to terminate earth rod = 1 no. (d) Copper strip of 300x25x6 mm (MEEB) = 1 no. (e) Copper strip of 150x25x6mm (SEEB) = 1 no. (ii) Supply of 35 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting main earth electrode to MEEB in the equipment room in duplicate.(minimum 10 meter) (iii) Supply of 16 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting MEEB to SEEB and SPD to MEEB (minimum 10 meter ) (iv) Supply of 10 sq. mm multi strand single core PVC insulated copper cable as per IS: 694 for connecting various equipment to SEEB (minimum 10 meter ) (v) Supply of copper lug sleeve for 3/16 cable Inspection: RDSO. | — | — | — | 90,882 | |
| — | 6.00 | — | — | ||
| Installation of Unit Maintenance Free Earth as supplied in above item. It includes ( i ) Digging the earth to the required depth. (ii) Insertion of electrode. (iii) Filling of earth enhancing compound (Approx.30 Kg) (iv) Provision of exothermic weld connections to copper tape of 25 mm x 6 mm x 150 mm to the earth electrodes. All material tools and features required for weld will be arranged by contractor. (v) This also includes CC cover 1.5 ft x 1.5 ft. 1 ft wall thickness 2 inch with cover 3-inch thickness. Cables 35 Sq mm/ 16 Sq mm/10 sq mm for connecting earth to busbar, busbar to busbar and bus bars to various equipment. Earth electrode of 17.20 mm dia and 3.00 meter long high tensile low carbon steel circular rods molecularly bonded with copper and outer surface (minimum copper bonding thickness of 250 microns to made requirement of under writer's laboratories (UL) 467-2007 or latest. Copper strips of 150 mm x 25 mm x 6 mm to be welded with each earth electrode, copper strips of 300 mm x 25 mm x 6 mm for main equip- potential bus bar, copper strips of 150 mm x 25 mm x 6 mm sub equip-potential bus bar in relay room, power room and panel room. GI strip 25 mm x 2 mm for ring formation of earth pits Earth enhancement material in bags for each Earth Electrode. Inspection chamber of site 300 mm x 300 mm x 300 mm (Inside dimension) of approximate 50 mm thick with pulling hooks to cover the earth pits. Note: The installation of this item shall be carried out by the contractor as per RDSO Specs. No RDSO/SPN/197 Ver.1.0 or latest and conforming to RDSO Drg. No. SDO / RDSO/ E&B/001 or Latest. Inspection: Consignee. | — | — | — | 39,474 | |
| — | 2.00 | — | — | ||
| Design, Preparation & Checking of cable corrage plan in size U(A3) or latest as per SEM. Note- i) Contractor has to collect approved Signal Interlocking Plan (SIP)/ESP from the Rly. ii) After design, development & Preparation of above diagram & drawings, contractor has to submit initially two (02) sets of paper print for checking in the Rly office. Thereafter, contractor will collect one (01) set of checked copy for necessary correction/modification/alteration, if any. iii) Only minor corrections, if any will be incorporated in the original tracing paper will be done by the Railways. iv) If there are major corrections/mistakes found during checking on paper print by Railways, then the same one (01) set of the original prints tracing papers & two (02) sets of paper prints has to be re- submitted for checking & approval. v) After approval, contractor will collect approved copies and submit 3 sets paper print along with, original tracing paper. vi) After commissioning of the work, contractor shall prepare all the completion drawings in 2 sets and put up it to approval of Rlys. Within one month and subsequently after their approval submit the original prints on tracing papers. vii) After approval on the original tracing all drawings in 3 sets except SIP in 06 nos. of hard copy/blueprint along with the original tracing complete in all respects and two sets of soft copies in pendrive to be handed over to the railways. viii) In course of execution of the work, any future development, additions and alterations etc., also to be incorporated in the circuit diagram as well as soft copy by the contractor at the completion stage. ix) All the drawing should be provided on good quality plotter paper. | — | — | — | 4,990 | |
| — | 2.00 | — | — | ||
| Design, Preparation & Checking of cable route plan / Track bonding Plan in size U(A3) or latest as per SEM. Note- i) Contractor has to collect approved Signal Interlocking Plan (SIP)/ESP from the Rly. ii) After design, development & Preparation of above diagram & drawings, contractor has to submit initially two (02) sets of paper print for checking in the Rly office. Thereafter, contractor will collect one (01) set of checked copy for necessary correction/modification/alteration, if any. iii) Only minor corrections, if any will be incorporated in the original tracing paper will be done by the Railways. iv) If there are major corrections/mistakes found during checking on paper print by Railways, then the same one (01) set of the original prints tracing papers & two (02) sets of paper prints has to be re-submitted for checking & approval. v) After approval, contractor will collect approved copies and submit 3 sets paper print along with, original tracing paper. vi) After commissioning of the work, contractor shall prepare all the completion drawings in 2 sets and put up it to approval of Rlys. Within one month or as defined in the tender document and subsequently after their approval submit the original prints on tracing papers. vii) After approval on the original tracing all drawings in 3 sets except SIP in 06 nos. of hard copy/blueprint along with the original tracing complete in all respects and two sets of soft copies pendrive to be handed over to the railways. viii) In course of execution of the work, any future development, additions and alterations etc., also to be incorporated in the circuit diagram as well as soft copy by the contractor at the completion stage. ix) All the drawing should be provided on good quality plotter paper. | — | — | — | 2,496 | |
| — | 2.00 | — | — | ||
| Supply of programmable fault diagnostic work station which is a Desktop computer having minimum specification of CPU i3 12100, 8 GB DDR 4 RAM , 512 GB SSD,USB ports, LAN ports, HDMI ports, audio port etc., camera, Key board, mouse, Window 11 with license, MS office 2018, 19.5 inch LED monitor, one year antivirus license. Make- HP, DELL, Lenovo, ACER. Inspection- Consignee | — | — | — | 92,680 | |
| — | 2.00 | — | — | ||
| Supply of laser colour computer printer automatic 2-sided Colour Print ( auto duplex feature) for A4 paper size , other paper sizes as per OEM with wireless, network connectivity and with 3 years warranty . Make-model : Brother HL-L3280 CDW or similar. It includes supply of Power Cable, USB Cable, Installation CD, Toner cartridges, other accessories as per OEM alongwith the printer. Item to be supplied after successful demonstration and Approval of Railway. Inspection : Consignee | — | — | — | 62,768.92 | |
| — | 300.00 | — | — | ||
| Supply of 1 x 16 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 694:2010 or latest, 126 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.0 mm and nominal conductor resistance of 1.21 ohms/km and test parameters as per RDSO Specn.No.IRS:S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer incharge. Inspection: RDSO | — | — | — | 39,300 | |
| — | 400.00 | — | — | ||
| Supply of 1 x 35 Sq.mm. (Red/Black/Green) multi strand copper power wire as per IS: 694:2010 or latest, 276 conductor each dia 0.40mm +/- 0.01 with insulation thickness of 1.2 mm and nominal conductor resistance of 0.554 ohms/km and test parameters as per RDSO Specn.No.IRS: S- 76/89(Amnd.3) or latest. Color of the wire which is required will be specified by the Engineer in charge. Inspection: RDSO | — | — | — | 70,800 | |
| — | 15.00 | — | — | ||
| Supply of Main equipotential bus bar (MEBB) of size 300x25x6 mm Cu equipotential Bus Bar. Inspection : Consignee | — | — | — | 4,110 | |
| — | 4.50 | — | — | ||
| Fixing & installation of copper tape 25 X 6 mm on insulated stand off including supply of 6KVA insulation studs. Note- In case of installation of MEBB & SEBB, payment will be made proportionally. | — | — | — | 981 | |
| — | 50.00 | — | — | ||
| Execution of exothermic weld for cooper wire upto 35 sq.mm size alongwith supply of required materials for welding . This includes supply of mould, welding powder , copper sleeves of required size and other required materials, tools for execution of exothermic welding. | — | — | — | 10,323.5 | |
| — | 6.00 | — | — | ||
| Supply & transportation of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/2012, Ver.3 or latest without tool kit. The length of Tx & Rx cable shall be of 5/10/15 m to meet the site requirements. This also includes supply of Mushroom and/ or Location Box or both suitable for housing Track side equipment as per OEM requirements. Inspection of SSDAC: RDSO and Inspection of mushroom / location box : Consignee | — | — | — | 34,69,200 | |
| — | 6.00 | — | — | ||
| Installation, Testing & Commissioning of Single Section Digital Axle Counter phase reversal type as per Specification No. RDSO/SPN/177/ 2012, Ver.3 or latest. This also includes supply & installation of maintenance free earth materials and exothermic bonding and other connecting Cable etc as per RDSO specification. No: RDSO/SPN/ 197/2008 or latest including foundation of Mushroom and/ or Location Box or both. Resetting equipment to be connected to the earth. This work to be done in presence of qualified Engineer of OEM. For installation, testing, commissioning all required materials to be supplied by Contractor | — | — | — | 5,31,000 | |
| — | 1.00 | — | — | ||
| Supply & transportation of tool kit of SSDAC phase reversal type as per Specification No. RDSO/SPN/177/2012, Ver.3 or latest. Inspection: Consignee Note: Toolkit , instruments, marking jig etc. as per OEM recommended list. | — | — | — | 81,701 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .