Loading…
Loading…
Tender Value
₹47.3 L
EMD Value
₹94,700
Closing Date
8 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Revenue
Above/Below/Par
ADEE G GRC
12 conditions · 5 needing a document upload
Bidder should submit copy of GST registration certificate along with the bid. GST will levied as per instruction circulated by GOI from time to time and bidder should comply with the same.
Tenderers are required to upload their Permanent Account Number (PAN)card.
Tenderer has to submit mandatory declaration for Retired Railway employee as per Proforma attached in compliance to Clause 16 of IR GCC along with the tender.
Tender shall carefully go through clause 14 of GCC 2022 part I and submit the requisite document such as Power of Attorney, Board Resolution, Partnership deed etc. as applicable. The tender to be participated & signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Bidder is to submit Bid Security as per clause 5 of GCC 2022 part I along with the offers.
The security deposit shall be as per the clause 16.1 of GCC 2022 part II.
Performance Guarantee shall be as per clause 16.4 of GCC 2022 Part II.
Tender is governed by the conditioned mentioned in the NIT, General Condition of Contract 2022 with latest amendments, special conditions attached with the NIT and conditions mentioned in the other attached documents with the NIT. The order of precedence is given in the GCC 2022
In terms of Railway Board letter No. 2022/CE-I/CT/GCC Correspondence dated 14.05.2024, It is clarified that "On IREPS Module a facility has already been created for online submission of Annexure-V. Therefore, the provision of downloading of Annexure-V by the tenderer had been discontinued on IREPS". Accordingly, the tenderer shall submit/complete Annexure-V through the online facility available in IREPS at the time of electronic submission of the bid. In case the said online facility is not available in IREPS at the time of bidding, the bidder shall upload a scanned copy of the duly signed Annexure-V.
Miscellaneous maintenance contract for Electrical General Service maintenance at different service buildings of S.E.Railway complex, Garden Reach, RSBO & SHM for a period of two years .
ADEE-G-GRC-MMC-26-1~SER
ADEE-G-GRC-MMC-26-1
Open
Works - General
24 Months
Unknown (Unspecified Location)
₹0
₹94,700
11 Sept 2026
11 Sept 2026
24 Sept 2026
153 items across 1 schedule
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 47,32,970.56 | ||
| — | 200.00 | — | — | ||
| Surface wiring for light, fan, 6 amps. plug point etc. by PVC insulated, FR-LSH, copper conductor, 1.5 Sq.mm. (phase & neutral) as per IS:694/latest , through heavy duty rigid plain PVC Casing-Capping/Conduit Pipe as per IS: 9537 (Pt.III)/latest etc as detailed in Explanatory Note. Each 6A plug point will be considered as half point. | — | — | — | 58,056 | |
| — | 100.00 | — | — | ||
| Supply of surface mounted switch socket board (Power), shutter type 16/6 Amps 5- pin socket-01 with 16 Amps switch-01 as per IS:1293 and IS:3854.latest, on a suitable PVC gang box, including internal wiring with PVC wire as per IS:694/latest. Detailed in Explanatory Note | — | — | — | 17,228 | |
| — | 100.00 | — | — | ||
| Fixing and commissioning of surface mounted switch socket board (Power),(as mentioned at item no 2) shutter type 16/6 Amps 5-pin socket-01 with 16 Amps switch-01 as per IS:1293 and IS: 3854.latest, on a suitable PVC gang box, including internal wiring with PVC wire as per IS:694/latest. Detailed in Explanatory Note | — | — | — | 826 | |
| — | 1500.00 | — | — | ||
| Surface wiring for drawing of main service/sub-service line etc. by PVC insulated, FR- LSH, copper conductor,2.5 Sq. mm. (phase & neutral) as per IS:694/latest , through heavy duty rigid plain PVC Casing-Capping/Conduit as per IS: 9537 (Pt.III)/latest with continuous earth wire by PVC insulated, FR-LSH, copper conductor, 2.5 Sq. mm as per IS:694/latest. Detailed in Explanatory Note. | — | — | — | 1,52,220 | |
| — | 1500.00 | — | — | ||
| Surface wiring for drawing of main service/sub-service/computer line/ac line etc. by PVC insulated, FR-LSH, copper conductor,4.0 Sq. mm. (phase & neutral) as per IS:694/latest, through heavy duty rigid plain PVC Casing Capping/Conduit as per IS: 9537 (Pt.III)/latest with continuous earth wire by PVC insulated, FR-LSH, copper conductor, 4.0 Sq. mm as per IS:694/latest. Detailed in Explanatory Note. | — | — | — | 1,61,070 | |
| — | 600.00 | — | — | ||
| Surface wiring for drawing of main service line by PVC insulated, FR-LSH, copper conduct 6.0 Sq.mm. (Phase & Neutral) as per IS:694/latest, with continuous earth wire by PVC insulated, FR-LSH, copper conductor 6.0 Sq.mm as per IS:694/latest, through heavy duty rigid plain PVC Casing-Capping/Conduit Pipe as per IS: 9537 (Pt.III)/latest etc. Detailed in Explanatory Note. | — | — | — | 75,756 | |
| — | 50.00 | — | — | ||
| Supply fixing and commissioning of Computer Board consisting of 02 nos. 6A & 1 no. 16A socket 5-pin & switch, fuse, indicating lamp etc. as per IS:1293 and IS: 3854.latest with internal wiring and connection as per site requirement. Detailed in Explanatory Note. | — | — | — | 13,865 | |
| — | 50.00 | — | — | ||
| Fixing and commissioning of Computer Board (as mentioned at item no 7) with internal wiring and connection as per site requirement. Detailed in Explanatory Note. | — | — | — | 708 | |
| — | 1200.00 | — | — | ||
| Concealed wiring of light, fan, 6 amps. plug point etc. by PVC insulated, FR-LSH, copper conductor, 1.5 Sq.mm. (phase & neutral) as per IS:694/latest, through heavy duty rigid plain PVC Conduit as per IS: 9537 Part- 3 , with continuous earth wire by PVC insulated, FR-LSH, copper conductor, 2.5 Sq. mm. as per IS:694/latest etc. with supply & fixing of Modular Switch Board with modular switch, socket etc as per IS:1293 and IS:3854 and all other requisite materials. Provision of concealed wiring shall be made by means of cutting wall/ceiling etc. as well as refilling, refinishing, painting etc. each 6A plug point will be considered as half point. Detailed in Explanatory Note. | — | — | — | 8,21,280 | |
| — | 200.00 | — | — | ||
| Supply of concealed mounted switch socket board (Power), shutter type 6/16 Amps 5-pin socket-01 with 16 Amps switch-01 as per IS:1293 and IS:3854 on a suitable PVC gang box, including internal wiring with PVC wire as per IS:694/latest. Detailed in Explanatory Note. | — | — | — | 45,548 | |
| — | 200.00 | — | — | ||
| Fixing and commissioning of concealed mounted switch socket board (Power), as mentioned at item no 10, including internal wiring with PVC wire as per IS:694/latest. Detailed in Explanatory Note. | — | — | — | 2,360 | |
| — | 4000.00 | — | — | ||
| Concealed wiring for drawing of main service/sub-service line etc. by PVC insulated, FR-LSH, copper conductor,2.5 Sq. mm. as per IS:694/latest (phase & neutral), through heavy duty rigid plain PVC Conduit as per IS: 9537 Part- 3 with continuous earth wire by PVC insulated, FR-LSH, copper conductor, 2.5 Sq. mm. as per IS:694/latest. Provision of concealed wiring shall be made by means of cutting wall/ceiling, laying PVC conduits, PVC cables etc. with plastering/refinishing etc. [rate per mtr. shall mean and include supply/laying/fixing of 1 mtr. phase cable, 1mtr. neutral cable and 1mtr. earth cable, 1 mtr. conduit and other associated wiring materials including connections etc.]. Detailed in Explanatory Note. | — | — | — | 3,82,320 | |
| — | 3000.00 | — | — | ||
| Concealed wiring for drawing of main service/sub-service/computer line/ac line etc. by PVC insulated, FR-LSH, copper conductor,4 Sq. mm. as per IS:694/latest (phase & neutral), through heavy duty rigid plain PVC Conduit with continuous earth wire by PVC insulated, FR-LSH, copper conductor, 4.0 Sq. mm as per IS:694/latest. Provision of concealed wiring shall be made by means of cutting wall/ceiling, laying PVC conduits as per IS: 9537 Part- 3, PVC cables etc. with plastering/refinishing etc. [rate per mtr. shall mean and include supply/laying/fixing of 1 mtr. phase cable, 1mtr. neutral cable and 1mtr. earth cable, 1 mtr. conduit and other associated wiring materials including connections etc. Detailed in Explanatory Note. | — | — | — | 4,99,140 | |
| — | 2000.00 | — | — | ||
| Concealed wiring for drawing of main service line by PVC insulated, FR-LSH, copper conduct 6.0 Sq.mm. as per IS:694/latest (Phase & Neutral), with continuous earth wire by PVC insulated, FR-LSH, copper conductor 6.0 Sq.mm as per IS:694/latest, Provision of concealed wiring shall be made by means of cutting wall/ceiling, laying PVC conduits as per IS: 9537 Part- 3, PVC cables etc. with plastering/refinishing etc. [rate per mtr. shall mean and include supply/laying/fixing of 1 mtr. phase cable, 1mtr. neutral cable and 1mtr. earth cable, 1 mtr. conduit and other associated wiring materials including connections etc. Detailed in Explanatory Note. | — | — | — | 3,65,800 | |
| — | 100.00 | — | — | ||
| Supply of modular computer board consisting of 02 Nos 6A & 01 Nos 16A socket 5- pin and switch, indicating lamp, 01 nos 16A fuse as per IS:1293 and IS:3854 including GI box, cover plate etc. with all necessary wiring as per site requirement for concealed wiring. Detailed in Explanatory Note. | — | — | — | 87,792 | |
| — | 100.00 | — | — | ||
| Fixing and commissioning of modular computer board (as mentioned at item no 15) with all necessary wiring as per site requirement for concealed wiring. Detailed in Explanatory Note. | — | — | — | 4,602 | |
| — | 4.00 | — | — | ||
| Supply of FP 400 Amps,50kA MCCB as per IS: 13947 (Pt.2)/latest with sheet steel powder painted enclosure. Detailed in Explanatory Note. | — | — | — | 57,574.56 | |
| — | 4.00 | — | — | ||
| Fixing and Commissioning of FP 400 Amps,50kA MCCB as mentioned at item no 17 with sheet steel powder painted enclosure. Detailed in Explanatory Note. | — | — | — | 2,879.2 | |
| — | 6.00 | — | — | ||
| Supply of 250A ,36kA FP MCCB as per IS: 13947 (Pt.2)/latest with sheet steel powder coated enclosure. Detailed in Explanatory Note. | — | — | — | 1,00,819.2 | |
| — | 6.00 | — | — | ||
| Fixing and Commissioning of 250A ,36kA FP MCCB as mentioned at item no 19 with sheet steel powder coated enclosure. Detailed in Explanatory Note. | — | — | — | 5,040.96 | |
| — | 8.00 | — | — | ||
| Supply of 125A ,36kA FP MCCB as per IS: 13947 (Pt.2)/latest with sheet steel powder coated enclosure. Detailed in Explanatory Note. | — | — | — | 50,013.12 | |
| — | 8.00 | — | — | ||
| Fixing and Commissioning of 125A ,36kA FP MCCB as mentioned at item no 21 with sheet steel powder coated enclosure. Detailed in Explanatory Note. | — | — | — | 3,049.12 | |
| — | 1200.00 | — | — | ||
| Laying of cable/ cables on wall / structure through PVC casing pipe with accessories or as per site requirement with suitable clamp / saddle/ fixtures etc. with necessary termination, connection and testing as per standard drawing. Cost also includes collection of cable/cables from Railway store. If required. Detailed in Explanatory Note. | — | — | — | 59,472 | |
| — | 600.00 | — | — | ||
| Laying of cable / cables in underground along the road through cable trench etc . as per standard drawing including necessary termination, connection and testing. Trenching and laying of U/G cables in any kind of soil trench of size minimum 0.40 mtr wide and 1 mtr deep covered with necessary bricks for protection of the cables including filling of space between brick and cable/cables with sand and refilling the trench with excavated soil, leveling up, and restoring the surface duly rammed. Cable will be supplied by Rly. Detailed in Explanatory Note. | — | — | — | 84,960 | |
| — | 200.00 | — | — | ||
| Micro drilling, laying of cable in underground inclusive of arranging all tools equipment, machineries etc. Detailed in Explanatory Note. | — | — | — | 1,85,260 | |
| — | 5.00 | — | — | ||
| Supply of 7 Mtr. length SST pole as per IS: 2713 (Part - I, III) : 1980 of weight 73 KG having Single/Double arm bracket (as per requirement) of length one Mtr., top cap etc. (the rate shall be inclusive of all materials). Detailed in Explanatory Note. | — | — | — | 39,099.3 | |
| — | 5.00 | — | — | ||
| Fixing and commissioning of 7 Mtr. length SST pole as mentioned at item no 26 with 1/6 of the pole to be buried in ground, concreating the foundation of size 1m x1m x1.2m in the ratio 1:3:6 and construction of muffing of size 1.5ft x1.5ft x 1.5ft & painting of pole (the rate shall be inclusive of all materials). Detailed in Explanatory Note. | — | — | — | 12,826.6 | |
| — | 5.00 | — | — | ||
| Fixing of light fitting/luminaire (to be supplied by Rly) to the pole and necessary wiring with 2.5 Sq.mm Cu wire as per IS:694/latest through the pole and termination to junction box and lamp point with supply of all materials. Detailed in Explanatory Note. | — | — | — | 3,197.8 | |
| — | 30.00 | — | — | ||
| Scratching of Electric post by wire brush then painting. Detailed in Explanatory Note. | — | — | — | 3,894 | |
| — | 10.00 | — | — | ||
| Electric Pole cutting (Pole to be deposited at Consignee's office.) Detailed in Explanatory Note. | — | — | — | 12,378.2 | |
| — | 40.00 | — | — | ||
| Tree branch trimming as per advice of site in charge. Detailed in Explanatory Note. | — | — | — | 3,540 | |
| — | 20.00 | — | — | ||
| Muffing of posts as per GEN. Detailed in Explanatory Note. | — | — | — | 7,080 | |
| — | 5.00 | — | — | ||
| Supply of required materials including nuts, bolts, washers and making various size of M/S clamp, bracket, hook and its painting by supplying paint as per site requirement and advise of Railway site engineer and fixing at specified locations. Detailed in Explanatory Note. | — | — | — | 265.5 | |
| — | 2.00 | — | — | ||
| Replacement of 3-phase distribution transformer (250kVA to 500kVA): Work involves dismantling of existing plinth/pole mounted 3-phase distribution transformer and replacement with another transformer to be collected from Railway store, its installation, HV/LV connection and commissioning. Replaced transformer to be returned to Railway store. with necessary transport such as truck/trolley, M.S channel & chain pulley block and necessary tools/ropes/skilled/unskilled labours to be arranged by contractor including Crane charges if necessary. Detailed in Explanatory Note. | — | — | — | 8,283.6 | |
| — | 1500.00 | — | — | ||
| Electrical Transformer Oil Filtration with Removal of moisture from 100 ppm to 3 ppm (max.), Removal of dissolved gas content from 10% by Vol. to 0.1% by vol, Improvement of dielectric strength break down voltage. The cost also includes transportation of oil from site to Lab with manpower and other required accessories. Detailed in Explanatory Note. | — | — | — | 40,710 | |
| — | 500.00 | — | — | ||
| Fixing of light fittings (to be supplied by Railway) on ceiling/roof/wall/false ceiling as per instructions of Railway and connections, Detailed in Explanatory Note. | — | — | — | 28,910 | |
| — | 50.00 | — | — | ||
| Supply of down rod 600 mm for ceiling fan as and when required by Railway. The down rod shall be made of 2mm nominal thick ERW Pipe and capable to withstand sufficient load without breakdown as per clause 10.14.1 of IS:374/latest. | — | — | — | 1,239 | |
| — | 50.00 | — | — | ||
| Supply of down rod 1200 mm for ceiling fan as and when required by Railway. The down rod shall be made of 2mm nominal thick ERW Pipe and capable to withstand sufficient load without breakdown as per clause 10.14.1 of IS:374/latest. | — | — | — | 2,773 | |
| — | 50.00 | — | — | ||
| Supply of down rod 1800 mm for ceiling fan as and when required by Railway. The down rod shall be made of 2mm nominal thick ERW Pipe and capable to withstand sufficient load without breakdown as per clause 10.14.1 of IS:374/latest. | — | — | — | 3,776 | |
| — | 3500.00 | — | — | ||
| Cleaning of ceiling fan/exhaust fan/wall bracket fan/pedestal fan etc. with safety checking (split pin, hook, insulator, tightness of all nuts & screws etc.) in different service buildings or other important locations, as advised by Railway, with checking/making of connections, if required. | — | — | — | 1,07,380 | |
| — | 50.00 | — | — | ||
| Removing of ceiling fan/ex fan from ceiling/roof/wall, cleaning and spray painting by synthetic enamel acrylic paint over anti-corrosive primer duly preparing painting surface by scraping and refixing the same and providing electrical connection. Detailed in Explanatory Note. | — | — | — | 8,968 | |
| — | 300.00 | — | — | ||
| Replacement of ceiling fan/exhaust fan/wall bracket etc. on ceiling/roof/wall as per instruction of Railway as detailed in the Explanation Note. | — | — | — | 7,434 | |
| — | 1500.00 | — | — | ||
| Replacement of LED light on ceiling/roof/wall/false ceiling as per instruction of Railway as detailed in explanatory note. | — | — | — | 33,630 | |
| — | 50.00 | — | — | ||
| Overhauling, rewinding, change of bearing (if required), and safety checking of ceiling fans including cleaning & Painting of ceiling fan. Detailed in explanatory note. | — | — | — | 16,815 | |
| — | 30.00 | — | — | ||
| Removing of exhaust fan/wall bracket fan/pedestal fan from wall or roof, rewinding of the defective motor with overhauling and cleaning/replacement of bearing, greasing, replacement of condenser as necessary etc., spray painting and refixing the same and providing electrical connection. Detailed in Explanatory Note. | — | — | — | 13,806 | |
| — | 4.00 | — | — | ||
| Repairing of H.S. Pump (suitable for motor up to 50HP) by replacing the shaft, bush, gland cup, bearing and other accessories as per IS 900 (1992) , if any, with warranty of one year. | — | — | — | 21,546.8 | |
| — | 4.00 | — | — | ||
| Rewinding of three phase motor up to 50 HP, overhauling and cleaning/replacement of bearing and hub as necessary, with warranty of one year. | — | — | — | 21,334.4 | |
| — | 6.00 | — | — | ||
| Supply of LT Heat Shrinkable Straight Through Jointing Kit as per specification IS- 13573:2011 or latest for 70-150 Sq.mm LT XLPE Cable. | — | — | — | 9,664.2 | |
| — | 6.00 | — | — | ||
| Fixing and commissioning of LT Heat Shrinkable Straight Through Jointing Kit as mentioned at item no 48. | — | — | — | 481.44 | |
| — | 4.00 | — | — | ||
| Supply of HT Heat shrinkable Straight Through Joint Kit for XLPE cable as per specification IS-13573:2011 or latest of size3X120-185 Sq.mm. | — | — | — | 26,955.92 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of HT Heat shrinkable Straight Through Joint Kit for XLPE cable as mentioned at item no 50. | — | — | — | 2,223.12 | |
| — | 6.00 | — | — | ||
| Supply of HT Heat shrinkable type End Termination Indoor type as per specification IS-13573:2011 or latest suitable for 3 x 120-185 Sq mm XLPE cable 11KV/E. | — | — | — | 22,054.2 | |
| — | 6.00 | — | — | ||
| Fixing and Commissioning of HT Heat shrinkable type End Termination Indoor type as mentioned at item no 52. | — | — | — | 1,359.36 | |
| — | 30.00 | — | — | ||
| Fixing and commissioning of LED 20 to 60 watt roadway luminaire with necessary fixing arrangement .Light will be supplied by Railway. Detailed in Explanatory Note. | — | — | — | 10,407.6 | |
| — | 40.00 | — | — | ||
| Supply of Wireless Multitone Doorbell With Remote, Selectable Melodies Calling Bell , Over 100 Meters Range Operating with all accessories etc. | — | — | — | 32,520.8 | |
| — | 40.00 | — | — | ||
| Fixing of Wireless Multitone Doorbell with Remote, Selectable Melodies Calling Bell, over 100 Meters Range Operating with all accessories etc. | — | — | — | 1,378.24 | |
| — | 50.00 | — | — | ||
| Transportation of New window AC Machine/s from Railway Stores; erection, testing and commissioning of the new AC machine at the specified locations as advised by Railway, inclusive of all requisite materials, masonry, smithy, electrical works as required including supply and fixing of wooden support (100mm x 75 mm) of requisite length on one side of the wall for fixing the AC Machines and covering of the blank area between the wall and AC machine by thermocol sheet for heat absorber; dismantling of the old AC Machine and handing over of the same to Railway Store with clear acknowledgement. | — | — | — | 54,339 | |
| — | 150.00 | — | — | ||
| Supply and fixing of Window AC Cover on the front side of the wall to improve the aesthetic view, made of Plywood Board 6 mm. thick. (width & length shall be as per actual site requirement), Varnish finish, complete with molded wooden bits of 6 mm width on the outer periphery of the cover, as per site requirement. | — | — | — | 15,753 | |
| — | 50.00 | — | — | ||
| Standard installation (new as well as replacement) of 1.5 TR / 2.0 TR Split Air- Conditioners (to be supplied by Rly) including erection, testing & commissioning of both indoor & outdoor units at specific locations inclusive of associated works like fixing of supporting structure/bracket, laying of insulated copper pipe, drain pipe, power cord through drilling holes in the wall, installation of power unit with required masonry, smithy, electrical works etc. as well as transportation of new AC machines from Rly. Store at site and handing over of old AC machine to Rly. Store with clear acknowledgement. | — | — | — | 64,959 | |
| — | 20.00 | — | — | ||
| Transportation Installation, testing and commissioning of 4TR tower AC with Tower AC Type: Inverter, Compressor Type: Reciprocating, Star Rating 3 Star and above including all required materials as per site (Materials will be supplied by Railway). Detailed in Explanatory Note. | — | — | — | 83,685.6 | |
| — | 300.00 | — | — | ||
| Supply of high-grade copper refrigerant pipe of adequate size (not less than 0.70 mm thick.) of suitable length as per actual site requirement and as per relevant specification, for suction and discharge, connecting both the units after drilling hole/holes in the wall, if required, with insulation and supporting PVC channel etc. as directed by Railway Authority. Detailed in the explanatory note. | — | — | — | 29,736 | |
| — | 300.00 | — | — | ||
| Laying and installation of high-grade copper refrigerant pipe of adequate size as mentioned at item no 61. as directed by Railway Authority. Detailed in Explanatory Note. | — | — | — | 7,434 | |
| — | 300.00 | — | — | ||
| Supply of high grade 15 mm drainpipe (high plastic bedded) of suitable length as per actual requirement and as per relevant specification for drainage of condensed water. | — | — | — | 5,310 | |
| — | 300.00 | — | — | ||
| Laying and installation of high grade 15 mm drainpipe as mentioned at item no 63 with suitable brackets/clamps (spaced not above 2 ft. each) etc. as directed by Railway Authority Detailed in Explanatory Note. | — | — | — | 1,770 | |
| — | 60.00 | — | — | ||
| Supply and fixing of R/Capacitor of (45 mfd to 55 mfd ) with other associated wiring materials, including connections etc. | — | — | — | 13,452 | |
| — | 60.00 | — | — | ||
| Fixing of R/Capacitor of as mentioned at item no 65. | — | — | — | 708 | |
| — | 500.00 | — | — | ||
| Supply and fixing of 32 mm thickness closed cell Aluminium Foil Faced Nitrile Rubber insulation on AC air ducting after removing of Old and damaged insulation with proper adhesive and all required materials as per site requirement. | — | — | — | 4,07,690 | |
| — | 70.00 | — | — | ||
| Supply of R/Capacitor of (3.5 mfd to 10 mfd ) with other associated wiring materials, etc. | — | — | — | 4,708.2 | |
| — | 70.00 | — | — | ||
| Fixing of R/Capacitor as mentioned at item no 68 including connections etc. | — | — | — | 247.8 | |
| — | 100.00 | — | — | ||
| Supply of stand/supporting structure/bracket made of MS Angle (50mm x 8 mm) to be fabricated as L shape with supporting angle (total fabricated length of the MS Angle shall not be less than 850 mm) for installation of the AC Machines [2 nos. per machine], inclusive of all requisite materials for masonry, smithy etc. as per site requirement. | — | — | — | 59,472 | |
| — | 100.00 | — | — | ||
| Fixing of stand/supporting structure/bracket made of MS Angle as mentioned at item no 70, inclusive of all requisite works of masonry, smithy etc. as per site requirement. | — | — | — | 18,762 | |
| — | 30.00 | — | — | ||
| Supply of Earth cone including sump box as per CEE-GRC's Drawing no: CEE/G/A3/P- 150, Alt.1 and CEE/G/A-3/P-134 (MOD.-1) with supply of all items. Detailed in the explanatory note. | — | — | — | 45,701.4 | |
| — | 30.00 | — | — | ||
| Fixing and commissioning of Earth cone as mentioned at item no 72 including sump box with supply of all requisite items. Detailed in Explanatory Note. | — | — | — | 13,133.4 | |
| — | 4.00 | — | — | ||
| Supply of maintenance free Earthing system (Pipe in pipe technology) complete with mild steel earth pipe, back filed compound as per RDSO specification no . RDSO/PE/SPEC/D/PS/0109- 2008 (Rev.'0') or latest. | — | — | — | 39,260.96 | |
| — | 4.00 | — | — | ||
| Fixing and commissioning of maintenance free Earthing system (Pipe in pipe technology) as mentioned at item no 74 as per RDSO specification. | — | — | — | 13,791.84 | |
| — | 4.00 | — | — | ||
| Transportation of (6Tons/Trip) released materials from GRC Store to KGP Scrap yard by truck on road, with loading at GRC. | — | — | — | 1,09,485.12 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC 2022 ACS 8 to 11
ATTACHMENT
SpecialtermsandConditionsMMC.pdf Special condition of the contract
ATTACHMENT
Mandatoryaccesoriesforwiring.pdf
ATTACHMENT
GCCUpdateduptoACS-7.pdf
ATTACHMENT
CEEGA3P-134Mod.1.pdf
ATTACHMENT
CEEGA3P-150Alt.1.pdf
ATTACHMENT
ExplanatorynoteMMC_2.pdf
ATTACHMENT
TenderForms.pdf
ATTACHMENT
GCC2022ACS8to11-compressed1.pdf
ATTACHMENT
SpecialtermsandConditionsMMC.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .