Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹32.5 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹42.5 L+₹4.8 L (12.8%)Rejected-Finance | L2 | Rejected-Finance L2 Bidder | |
| 3 | L3₹45.7 L+₹8.0 L (21.2%)Rejected-Finance | L3 | Rejected-Finance L3 Bidder | |
| 4 | L4₹47.4 L+₹9.7 L (25.8%)Rejected-Finance 5A 139 NIT FARIDABAD HARYANA 121001 | FARIDABAD | HARYANA | 121001 | L4 | Rejected-Finance L4 bidder |
Tender Value
Refer Docs
EMD Value
₹1.2 L
Closing Date
19 Jul 2021, 3:00 pmClosed
G S AWSEKAR
INDO GERMAN TOOL ROOM, P-31 MIDC INDUSTRIAL AREA CHIKALTHANA AURANGABAD MAHARASHTRA 431006
SUPPLY OF COMPRESSOR AIR DRYER PRE POST FILTER TRIPLE LAYER PPR LINE CABLELAYINNG ETC
2021_DC_635969_1
GTR/AUR/EQP/PROD-01A/2021-22
Open Tender
Electrical Goods/Equipment
Supply
60 days
INDO GERMAN TOOL ROOM AURANGABAD
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,500
INDO GERMAN TOOL ROOM AURANGABAD
₹1.2 L
3 Sept 2021
28 Jun 2021
20 Jul 2021
28 Jun 2021
19 Jul 2021
5 Jul 2021
28 Jun 2021 - 3 Jul 2021
Supply, Installation & Commissioning of Compressor, Air Dryer, Pre Filter, Post Filter, Air Receiver, Triple Layer PPR (Poly Propylene Fiber Reinforced Co Polymer) Pneumatic Pipeline with Fabrication & Civl work for Control Panel Room & Cable Laying
Air compressor with mininmum 200 cfm capacity @ 7bar pressure
Refrigerated type Air Dryer of minimum 250 cfm Suitable for the 208 cfm Air Compressor of GEM / Garder Denver / IR / or equivalent OEM make standard Air Dryer
Pre Fliters for moisture collection suitable to installed compressor
Post Filters for water draining suitable to installed compressor
Air receiver 2.0 M3 to collect the compressed Air
Triple Layer (First layer PPR (Poly Propylene Random Co Polymer), Second layer glass fiber with FR (Fiber Reinforced) & Third layer PPR (Poly Propylene Random Co Polymer)) Pneumatic Pipeline
PPR Triple Layer Pipe (1) Anti Microboil PPR layer 2) Glass Fiber Compound FRP 3) UV Stabilized PPR-Fire Retandant PN-16 (SizeE 63 mm (OD) x 51 mm (ID) (2"))
PPR Triple Layer Pipe (1) Anti Microboil PPR layer 2) Glass Fiber Compound FRP 3) UV Stabilized PPR-Fire Retandant PN-16 (Size 50 mm (OD) x 40 mm (ID) (1 1/2"))
PPR Triple Layer Pipe (1) Anti Microboil PPR layer 2) Glass Fiber Compound FRP 3) UV Stabilized PPR-Fire Retandant PN-16 (Size 32 mm (OD) x 25 mm (ID) (1"))
PPR Blue Socket (20 Bar Tested Pressure) Size - 63 mm
PPR Blue Socket (20 Bar Tested Pressure) Size - 50 mm
PPR Blue Socket (20 Bar Tested Pressure) Size - 32 mm
PPR Blue Elbow (20 Bar Tested Pressure) Size - 63 mm
PPR Blue Elbow (20 Bar Tested Pressure) Size - 50 mm
PPR Blue Elbow (20 Bar Tested Pressure) Size - 32 mm
PPR Blue Reducing Tee (20 Bar Tested Pressure) Size - 63 x 50 mm
PPR Blue Reducing Tee (20 Bar Tested Pressure) Size - 63 x 32 mm
PPR Blue Reducing Tee (20 Bar Tested Pressure) Size - 50 x 32 mm
PPR Blue Equal Tee (20 Bar Tested Pressure) Size - 63 mm
PPR Blue Equal Tee (20 Bar Tested Pressure) Size - 50 mm
PPR Blue Equal Tee (20 Bar Tested Pressure) Size - 32 mm
PPR Blue End Cap (20 Bar Tested Pressure) Size - 63 mm
PPR Blue End Cap (20 Bar Tested Pressure) Size - 50 mm
PPR Blue End Cap (20 Bar Tested Pressure) Size- 32 mm
PPR Blue MTA (20 Bar Tested Pressure) Size - 60 mm x 2"
PPR Blue MTA (20 Bar Tested Pressure) Size – 50 mm x 1 1/2"
PPR Blue MTA (20 Bar Tested Pressure) Size - 32 mm x 1"
PPR Blue MTA (20 Bar Tested Pressure) Size - 32 mm x 1/2"
PPR Blue Core Flange (20 Bar Tested Pressure) Size - 63 mm
PPR Blue Core Flange (20 Bar Tested Pressure) Size - 50 mm
PPR Blue Reducer (20 Bar Tested Pressure) Size - 63 mm x 50 mm
PPR Blue Reducer (20 Bar Tested Pressure) Size - 63 mm x 32 mm
PPR Blue Reducer (20 Bar Tested Pressure) Size - 50 mm x 32 mm
M.S. Flange with Powder Coating – Size 63 mm 2"
M.S. Flange with Powder Coating - Size 50 mm 1 1/2"
Brass Body with Handel Industrial Ball Valve (I.S.I) Pressure Tested At 20bar Size-2"
Brass Body with Handel Industrial Ball Valve (I.S.I) Pressure Tested At 20bar Size- 1 1/2"
Brass Body with Handel Industrial Ball Valve (I.S.I) Pressure Tested At 20bar Size- 1"
Brass Body With Handle Industrial Ball Valve (I.S.I.) Pressure Tested At 20 Bar Size 1/2"
Galvanized Adjustable Cantilever C Channel With Base Plate Mounting Thickness 6 mm Size 41 x 21 x 300 mm
Pipe Clamp with Nut Bolt 63 mm
Pipe Clamp with Nut Bolt 50 mm
Pin Type Anker Fasteners M10 x 100 mm
Teflon Tape 1/2"
Split Clamp 0.5 mm Rubber Thickness Size 63 mm
Split Clamp 0.5 mm Rubber Thickness Size 50 mm
Split Clamp 0.5mm Rubber Thickness Size 32 mm
Solid Bullet Fasteners M10 x 50 mm
Threaded Road Zink Plated 10 mm x 2 mtrs
Pin Type Anker Fasteners M10 x 50 mm
Nut Bolt with Double Washer Zinc Plated M12 x 100 mm
EPDM Gasket 63 mm
EPDM Gasket 50 mm
Hardware (Airlite / Neel / Paint Spray / Welding Road / Drill Bits / Grinding Wheels / Etc)
ASA 150 MS Flange Adaptor 2" - Air Receiver
MS Reducer 3 x 2"
Testing of the total line will have to be carried out as per standards at 1.5 times the working pressure for complete length of the errected pipe line
Control Panel Room (Panel Room Fabrication + Civil Work+ Cable Laying)
Standard / Essential Accessories
Normal consumables spares required for 1 year smooth operation shopuld be included in the scope of supply includes - Air Filters, Oil Filters, Oil,
First & Second Fill of Compressor oil as well as lubricants during one year of operation.
Installation & Commissioning
Training Charges
Transportation , Charges
Ideas Electricals and Engineers Pvt. Ltd.
CORE Energy Systems Pvt. ltd.
Kataria Sales Private Limited
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .