| 1 | | SH I Replacement of HT Cable & MISC work
S & L of one number PVC insulated and PVC sheathed XLPE Aluminium power HT cable of 11 kV grade of ISI Marked of size 3 x 95sq.mm in Following ways etc. as required. ( Make Polycab Havells ss )
a) on surface of pole / wall | 20 | Mtr | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 2 | | b) in existing pipe/ metering cubicle | 25 | Mtr | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 3 | | c) direct in ground i/c excavation, and refilling the trench ( but without sand coushioning & protective covering ) | 35 | Mtr | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 4 | | S and M ID cable end termination for 3 core, cable of 11 kV grade as required. | 2 | job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 5 | | S and M OD cable end termination for 3 core, cable of 11 kV grade as required. | 2 | job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 6 | | Supplying and erection of three piece nonlinear resistor type lightning arrestor suitable for 3 wire, 11 kV overhead lines with rated voltage 9 kV (rms) with a nominal discharge current rating of 5 kA and complete with galvanised clamping arrangement, G.I. bolts, nuts, washers etc. as required. | 1 | set | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 7 | | Supplying and erection of 11 kv Potential Transformer of suitable rating i/c testing commissionin etc as required. | 3 | jobs | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 8 | | S and L of one number 75mm dia PVC Pipe for cable protection etc. as required. | 6 | Mtr | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 9 | | S. H. II Maintenance of Substation Out door yard
Servicing of all HT switchgears on the 11KV 2 pole outdoor structure | 1 | Job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |
| 10 | | Testing for IR value by meggering of all existing HT cables I/c physical testing, disconnecting the cable from supply/load & testing with 5KV megger i/c Testing earth value for the existing out door structure & indoor sub station earthng I/c disconnecting the earth strip from earth electrode/earth bus bar & testing with earth megger etc, complete as reqd. & submitting the results to the Engineer-in-charge etc complete as reqd. | 1 | Job | Sanjay Pandurang Kambale 580021,BSNL Electrical Division, I Indfloor Vidyanagar Telephone Exchange, Near RB Patil Hospital, Hubbali 580021 | 30 |