Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC 63 2ND MAIN ROAD NGO COLONY ADAMBAKKAM CHENNAI 600 088 | CHENNAI | CHENNAI | TAMIL NADU | 600088 | ₹15.5 L Quoted ₹16.0 L | L1 | Accepted-AOC L1 |
| 2 | L2₹16.3 L+₹29,691.60 (1.85%)Rejected-AOC NO 6 1 ALAGAR PERUMAL KOIL MAIN STREET VADAPALANI CHENNAI 600 026 | CHENNAI | CHENNAI | TAMIL NADU | 600026 | ₹16.3 L+₹29,691.60 (1.85%) | L2 | Rejected-AOC L1 being Accept |
| 3 | L3₹17.0 L+₹95,646 (5.97%)Rejected-AOC NO 3 JAMI JAM KHAN ROAD 1ST LANE ROYAPETTAH CHENNAI 600 014 | CHENNAI | CHENNAI | TAMIL NADU | 600014 | ₹17.0 L+₹95,646 (5.97%) | L3 | Rejected-AOC L1 being Accept |
| 4 | L4₹18.5 L+₹2.5 L (15.4%)Rejected-AOC NO 235 PSK ILLAM SANKARAN NAGAR CHINNAMMAN KOIL STREET AVADI CHENNAI 600 054 | CHENNAI | THIRUVALLUR | TAMIL NADU | 600054 | ₹18.5 L+₹2.5 L (15.4%) | L4 | Rejected-AOC L1 being Accept |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
25 May 2023, 6:00 pmClosed
CWE NAVY CHENNAI
Commander Works Engineers Navy Military Engineer Services Fort St George Rajaji Salai Chennai600 009
82535 REPAIRS/REPLACEMENT OF HT/LT INSTALLATION INCLUDING SERVICING OF TRANSFORMER, VCB/RMU, UG CABLE FEEDER PILLAR BOXES ETC UNDER AGE(I) NAVY CHENNAI
2023_MES_590500_1
CWE/NAVY/CHE/82535/E8 OF 2023-24
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
CHENNAI
As per NIT
8 documents required · 8 mandatory
₹500
AGE(I) NAVY CHENNAI
₹40,000
Yes
2 Sept 2023
25 Apr 2023
27 May 2023
25 Apr 2023
25 May 2023
12 May 2023
25 Apr 2023 - 2 May 2023
Amount
SCHEDULE 'A' PART-I [ E/M WORKS]
Excavation in trenches not exceeding 1.5 mtrs wide and not exceeding 1.5 mtr deep in hard /dense soil for laying underground cables and post holes complete all as specified and directed.
Returning filling in including spreading levelling watering and well ramming in layres not exceeding 25 cm thick in hard/ dense soil complete all as specified and directed.
Removing surplus soil to a distance not exceeding 50 m and depositing at a level not exceeding 1.5m above the starting point all as specified and directed.
M&L High density poly ethylene pipes (HDPE) 50mm dia of pressure rating 6 kgf/cm2 fixed complete to walls, ceilings or in floors etc complete all as specified and directed.
Material and labour for PCC 1:4:8, type D-2, using 40 mm graded stone aggregate as in foundation, filling and mass concrete all as specified and as directed.
Material and labour for PCC 1:3:6, type C-1, using 20 mm graded stone aggregate, as in foundation/ coping of poles including necessary form work and finishing the exposed concrete surfaces even and fair completea all as specified and as directed
Dismantling of GI earth/guard wire of any size and removing unserviceable GI wire from site complete all as specified and as directed.
Dismantling of old unserviceable stay assembly including stay wire complete with necessary demolition of concrete, excavation and earth work as required and removing the same from site complete all as specified and as directed.
Dismantling of old, unserviceable steel tubular pole & removing and taking into credit including necessary demolition of concrete, foundation along with earth excavation etc... all as specified and as directed.
Material and labour for Dismantling of old, unserviceable concrete pole/struts,any size & removing and taking into credit including necessary demolition of concrete, foundation along with earth excavation etc... all as specified and as directed.
Dismantling of cross arms of MS channel or angle section etc complete fixed on RCC/steel tubular poles carefully including separating and setting aside serviceable cross-arms for reuse in the work and removing unserviceable cross arms complete all as specified and as directed.
Dismantling of insulators of any type & size from position including separating & setting aside serviceable insulators for reuse in the work and removing unserviceable insulator from site complete all as specified and as directed.
Dismantling air break gang operated switches vertical/horizontal mounted including insulators and operating mechanism for repair/ replacement complete all as specified and directed.
Dismantling drop out fuse vertical/horizontal mounted including insulators for repair/ replacement complete all as specified and directed.
Dismantling and removing of GI pipe from trench/wall etc of size 40 mm to 100 mm dia, complete all as specified and directed.
Dismantling of lightning arresters of any type & size from position and removing from site complete all as specified and as directed.
Dismantling of anti climbing device, any type & size from position and removing from site complete all as specified & as directed.
Dismantling and removing from trench/duct etc. old armouned, XLPE insulated HT electric power cables and keeping in safe custody, complete all as specified and directed.
Dismantling and removing from trench/duct etc., old armouned, XLPE insulated LT electric power cables of any size and keeping in safe custody complete all as specified and directed
Material and labour for steel tubular swaged poles complete with cast iron base plate,finial tapper plug, bolt,nuts & screws, type 410 SP-31 (9.0 metres long) and fixing in concrete foundation, including two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil and concrete shall be measured and paid seperately)
Material and labour for prestressed concrete pole, 9.0 metres long, 102mm x 152mm at top and 102mm x 289mm at bottom, class 10, and fixing in concrete foundation, including two coats of cement base paint over a coat of primer complete all as specified and directed. (Note: Earthwork, excavation, RFR and removal of surplus soil and concrete shall be measured and paid seperately)
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 70 sqmm 3.5 core, 1100 volts grade, complete all as specified and directed. (Make : Havells/Polycab/Finolex) (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid seperately)
Supply and laying of XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, heavy duty electric power cables with stranded aluminium conductor of cross sectional area 95 sqmm 3 core, 11000 volts grade, complete all as specified and directed. (Make : Havells/Polycab/Finolex) (Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid seperately)
Material and labour for cradle gaurding, hexagonal / rectanguler fabricated with 4mm dia GI wire all as specified & directed
Supply and fix cross arms, bracing, support, clamps etc made out of mild steel channel or angle section of reqd size and shape including clamp, back plate with bolts, nuts & washers drilled for insulator bolts, welding, bending cold or hot in any shape or size including all fixing arrangement on HT over head line and painted with two coats of aluminium paint over a coat of red oxide primer complete all as specified and directed.
Fixing only old serviceable cross-arms obtained from dismantling here in before with providing new bolts, nuts and washers as reqd including painting with one coat of aluminium paint over a coat of red oxide primer after preparation of old surfaces complete all as specified and as directed.
Material and labour for for anti-climbing devices spike type fabricated from MS bar (8 mm size 10 Nos x 20 cm long) fixed by drilling/welding on 2 Nos MS flat 40 x 6 mm made to shape to suit the cross section of the pole and fixed at about 2.0 mtr height from GL including complete painting with two coat of aluminium paint over a coat of red oxide primer all as specified and directed.
Material and labour for danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, bigures and conventional shull and bones in signal red colour and fixed with MS clamps, bolts & nuts of approved size of HT 25 x 20 cm size complete all as specififed and directed.
Material and labour for surge or lightening arrester, metal oxide type for HT distribution line, nominal discharge current 10 KA, high current impulse with stand 63 KA (10 ms impulse) CL-I confirming to IS 3070 and IEC - 60099 - 4 including all fixing arrangement on HT pole complete all as specified and directed.
Supply and fix in replacement electromat high voltage mats conforming to IS 15652-2006 suitable for 11 KV ,thickness of 3.00 mm, width 1.5 mtrs with SR-998 adhensive complete all as specified and as directed.
Supply and replacement of Cable jointing kit for 1.1 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3.5 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed.
Supply and fixing (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed
Supply and fixing (in replacement) of Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm all as specified and directed
Supply and fixing of XLPE insulated screened PVC bedded galvanised steel strip or wire armoured electric cable(heavy duty) (LTUG) with aluminium conductor 1100 volts grade cross sectional area 3½ core 300 sq mm in trenches/on truss/wall/floor through pipe with MS clamps all as specified and directed Note: Earthwork, excavation, RFR and removal of surplus soil, river sand cushioning and PCC cover slab/ bricks for cable protection shall be measured and paid seperately
All as per item No 35 described here in before but of size 240 sq mm 3½ core all as specified and directed
All as per item No 35 described here in before but of size 70 sq mm 3½ core all as specified and directed
All as per item No 35 described here in before but of size 50 sq mm 3½ core all as specified and directed
All as per item No 35 described here in before but of size 35 sq mm 3½ core all as specified and directed
Supply and fixing of Stay assembly complete with following mentioned accessories as shown in electrical plate No. 1 including dismantling old unserviceable stay assembly complete and depositing where directed at site all as specified and as directed. (i) GI stay rod 20 mm dia 2150 mm long (ii) MS stay plate of size 300 x 300 mm, 6mm thick including bolts & nuts (iii) Stay GI stay bow Note : Excavation, earthwork, foundation concrete, stay wire, clamps and loop insulator shall be measured and paid separately under relevant items of this Schedule.
Supply and fix loop type insulator vitreous procelain white, brown or green small size with overall dimensions 90 x 140 mm and clearance of hole 25.5 mm complete all as specified & as directed.
Supply and fix galvanised stay strand of size 7/4 mm/7/3.15mm with necessary binding work with all as specified and as directed.
Supply and fixing of Pin type porcelain, vitreous, white, brown or green insulator of size 100 mm height, 65 mm dia for 1100 volts grade, including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron bolt all as specified and as directed.
All as per item No 43 described here in before but 150mm height, 150mm dia for 11000 volts grade all as specified and directed
Supply and fixing of Disc type insulator, porcelain, vitreous145mm height and 255mm dia ball and socket type white,brown or green, single disc assembly for tension clamps for conductors working pressure 11000 volts all as specified and as directed
Supplya and fix Shackle Type, Porcelain, vitreous, white, brown or green insulator including galvanised mild steel straps, washers,insulator including galvanised mild steel straps, insulator bolts, washers and nuts, for conductors working pressure 1100 volts,100X115mm dia of bolt 14mm all as specified and as directed
Material and labour for trenchless cutting (Non Man Entry Type) by HDD (Horizontal Directional Drilling ) method for boring a hole under road, pavement, hard standing including laying of HDPE (High Density Polyethylene) pipe of 150mm dia suitable for 0.4 Mpa (Mega Pascal) working pressure complete all as specified as per the IS Codes of Practice suiting Indian Conditions published by the Indian Society for Trenchless technology from time to time and as directed by GE. Note : The entire trenchless equipment shall be operated by the contractor strictly as per manufacturer's operation manual and a copy of same shall be provided to GE by contractor.
Supply and replacement of GI tubing medium grade 100mm bore galvanized with all fitting laid in trenches/road crossing for UG cable protection all as specified and as directed
All as per item No 48 described here-in-before but 80 mm dia all as specified and directed
All as per item No 48 described here-in-before but 50 mm dia all as specified and directed
All as per item No 48 described here-in-before but 40 mm dia all as specified and directed
Supply and fix straight through joints (epoxy) suitable for 3.5 core PVC insulated and PVC sheathed armoured LT underground cable with aluminium conductors including joint kits and labour complete for making joints all as specified d as directed for following :
(a) 3.50 core cable 35 Sq mm
(b) 3.50 core cable 50 Sq mm
(c) 3.50 core cable 70 Sq mm
(d) 3.50 core cable 240 Sq mm
(e) 3.50 core cable 300 Sq mm
Supply and spread crushed stone aggregate of not exceeding 40mm size 150mm thick layer over well prepared sand bed layer all as specified and as directed.
Supply and spread M-sand not exceeding 30 cm thick all as specified and as directed.
Servicing of two pole structure complete including replacement of unserviceable jumpers, sleeves, vice type connectors, bolts nuts washers connecting lugs/thimbles greasing the moving parts applying petroleum jelly on moving and fixed contacts, tightening all connection and preparing the old painted surfaces of the structure such as poles, cross arms, bracings and supports clamps back plates complete and painting two coats of anti corrosive aluminium paint over a coat of red oxide zinc chrome primer and providing yellow and black paint from the ground level all as directed at site by Engr-in-Charge Note :- No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the schedule
Servicing of four pole structure complete including replacement of unserviceable jumpers, sleeves, vice type connectors, bolts, nuts washers connecting lugs/thimbles greasing the moving parts applying petroleum jelly on moving and fixed contacts, tightening all connection and preparing the old painted surfaces of the structure such as poles, cross arms, bracings and supports clamps back plates complete and painting two coats of anti corrosive aluminium paint over a coat of red oxide zinc chrome primer all as directed at site by Engr-in-Charge Note :- No extra payment will be made for the spares required to keep the installation in satisfactory functioning through out the contract period other than given in the Sch 'A' given
Material and labour for Painting of LT/HT steel tubular pole with one coat of aluminum paint and black paint upto 1.2 meter from the bottom of the pole after preparing the existing surface of the poles and marking the poles numbers as per existing pattern including fixing two no flouresent tape 50 mm width around the pole at 1.2 meter height complete all as per specified and directed.
Supply and install , commissioning and testing air break switch,gang operator off load disconnection type,out door,mechanically operator from ground level and mounted on 11KV post insulators with and including MS channel base,MS nut,bolts forxfixing to the poles,capacity 200 A,3 phase and three insulators per phasecomplete with locking arrengement inON and OFF position including necessor conections all as directed and fixing to the pole structure in position including painting the steel surface with two coats of aluminium paint over a coat of red oxide primer etc all as specified and as directed.
Supply and fix in replacement of drop out fuses 11 KV, 100 Amps capacity including nut bolts washers with barrel fuse expulsion type set of three including mounting on channel complete all as directed
Earthing complete with copper earth plate electrode of size 600x600x3.15mm thick burried directly in ground (Earth pit not less than 2.25 mtr deep below ground level)with top edge of the plate not less than 1.5 Mtrs below normal ground level connected to copper earth strip of 20mmx3.0mm by means of bolts, nuts, check nuts and washers of copper all as shown in electric plate No 5 connecting to earthing test point including necessory excavationin any earth strata,PCC chambers in PCC1:3:6 type C1, RCC 1:2:4 type B1 cover slab 50mm thick with 8mm dia TMT HCR/CRS steel bars at 140mm C/C both way and lifting handle watering pipe of GI 20 mm dia light grade,funnels,wire mesh,charcoal with lifting handle watering pipe of GI light grade 20mm dia,wire mesh,funnel,lugs and charcoal,salt etc all as applicable and as per plate No 5 of SSR 1991 and all as specified
Material and labour for GI Chain link fencing including line wires, any mess, size and type of standards rail, straining, bolts, with necessary angle or 'J' section fixed independently with out connecting plate & making holes perfixing chain link fence Gde Fe 410-0 complete including spot holes, PCC for foundation etc. all as specified and directed.
Material and labour for MS Gate made out of angle iron of suitable size with necessary joining accessories complete, steel confirming to Gde Fe - 290 (Gde E-165) complete all as specified and directed. Note : Necessary earthwork excavation, PCC for foundation shall be measured and paid separately.
M & L for disconnecting carefully electrical connection from HT/LT sides of the transformer, keeping them at safe side and taking out the transformer Out door type 201 to 400 KVA, 0.433/11KV, comprising the following :step up any make carrying out complete overhauling which shall comprise of the following :-
(a) M & L for lifting, transporting, handling, the transformer to wksp and opening top cover of the transformer by unscrewing nuts, bolts, washers etc incl disconnecting core assy from HT/LT bushing and lifting the same gently and taking out from the shell (container/ body) of the transformer. (b) M & L for draining out transformer oil from the above said transformer in the suitable capacity of container /drums and keeping it insafe coustody for reuse. (c) M & L for cleaning of the transformer body from inside, removing deposited dirt / sludge/ foreign particles etc from the buttom / body of the transformer and drying/ heating up the shell from inside before refilling of the transformer oil.
(d) M&L for checking the leakage of transformer oil from tank joints, bushings, inlet/out let valves ,breather etc ,servicing,openning the transformer and disconnect the star and delta connection for HT and LT windings ,testing the insulation resistance,cleaning and washing thoroughly core and windings of the transformer by hosing down with clean dry oil conforming to IS 335/1983, removing deposited dirt/sludge/foreign particles from the windings / core and revarnishing of the windings with super varnish incl heating/drying/backing complete carefully and thoroughly inside the heating chamber at suitable temperature to obtain required value of insulation resistance etc all as per IS 1986-87 and directed by Engr-in- charge.
(e) Lifting and refixing core assy inside the transformer shell gently and carefully, connecting of HT / LT/ Neutral connections to the bushings assy, fixing of tap change over incl tightening of nuts,bolts, washers of the core to reduce humming noise all as directed. (f) Varnishing the entire core assembly with insulating oil of approved quality ,heating and drying thoroughly,re -insulation paper ,press pan paper, fevicol,sleeves and heating carefully inside chamber to got required megger value so as to obtain desired insulation resistance all as directed. (g) Re- fixing of the core assembly inside the transformer shell gently and carefully , conecting up with the HT/LT bushings ,fixing of tap changer, connecting up with the neutral connections etc completeall as specified and directed by Engineer-in- charge Note: Necessary dismentling of core assy for repair/rewinding and refixing shall be measured and paid under relevant items here in before all as specified and directed by Engineer-in- charge .
(h) Refilling the transformer oil in the shell of transformer only after carrying out filteration and heating up oil upto 105 degree C to achive reqd dielectric strength and submitting the test result before and after filteration of oil in presence of Engr- in- charge on proper proforma duly signed. (j) Refixing the top cover incl replacement of corck sheet/ gasket 8mm thick, tightening of nuts /bolts /washers etc and replacement of breather with silica gel crystal type all as directed by Engr-in charge (k) M & L for carrrying out acidity test of transformer oil all as per IS-1866/1961 in presence of Engr-in-charge or MES rep. authorised by him and submitting the test results on proper proforma duly signed. (l) Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint over one coat of primer all as specified and directed by Engineer-in- charge .
Note:- (i) Any damage to insulators/bushes/windings etc while in the custody of the contractor shall be made good at no extra cost to govt. The serviceability of the transformer shall be checked and confirmed by the contractor before taking into his custody. (ii) The job taken for repair / over hauling (exept item No. 4 & 5 here in after) should be complete with in 48 hours from the date of handing over the individual transformer , failing which neccessary arrangement to be made by the contractor at no extra cost.
All as per item no 63 above but Transformer of capacity101 to 200 KVA all as specified and directed.
Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint over one coat of primer all as specified and directed.
Dehyderation,filteration of transformer oil using stream line filter to obtain a dielectric strength above 40 KV, including all arrangement for DG set,filteration plant,filter paper etc mentioned below all as directed and specified.
Supply and Filling the new transfermer oil of approved make conforming to IS- 335 including filtertion of existing and taped up oil so as to achieve IR value of the oil not less than 40 KV and all as specifaied and all as directed by Engineer - in - charge.
M/L for rewinding of damaged/ burnt out HT / LT coil , servicing of step down transfomer of capacity 100 to 400 KVA capacity 11000/433 volts,comprising the following : (a) Removing the transformer core assembly by un-screwing the nuts, bolts,washers of top cover, draining out the exting oil removing the HT / LT bushings etc and taking out the core gently with the help of neccessary tools arrangement complete and all as directed. (b) Dismantling and taking the burnt HT coils from the core assembly and cleaning the other coils and core assembly with CTC solution including removing the deposited dirt/foreign meterials etc complete. (c) Rewinding the HT/LT coils with super enamelled copper winding wire of existing size including insulating paper etc complete ,refixing the rewinded HT/LT coils on the core assembly connecting up with the tap changer etc all as specified and directed by Engineer-in- charge .
M & L for disconnecting and dismantling u/s, damaged LT bushing, studs complete of 100 KVA Transformer any make 11/0.433 KV and replacing the same with supplying and fixing, connecting and commissioning LT porcelain bushings with gun metal threaded studs of suitable lengths including metal rings/nuts/bolts/washers, rubber rings etc.( set of 4) all as specified and directed by Engineer in charge.
All as per Item No 69 above but HT bushing comlete ( set of 3 ) all as specified and directed by Engineer in charge.
All as per Item No 69 above but for 200 and 500 KVA transformer 11000/433 volt any make all as specified and directed by Engr -in- charge.
All as per Item No 69 above but HT bushing comlete ( set of 3 ) for 200 and 500 KVA transformer 11000/433 volt any make all as specified and directed by Engr -in- charge.
Supply and replace transformer breather assembly with dry silca gel all as specifaied and all as directed by Engineer - in - charge.
Supply and replace dry silca gel of transfermer breather all as specifaied and all as directed by Engineer - in - charge.
Supply and fixed (in replacement) of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe of 25 mm dia all as specified and as directed by Engr - in - charge.
Cleaning / scrapping / brushing down and preparing the outer surface of the transformer body and painting with two coats of synthetic enamel paint of transformer 200 to 400 KVA capacity of approved make all as specified and directed by Engineer-in- charge .
Taking out vacuum circuit breaker by disconnecting carefully electrical connection from incoming and out going from panel carefully.Overhauling the spring charging mechanism,checking the vacuum gap,greasing and adjusting of moving parts and adjusting as required, Cleaning all parts by CTC solution / emry paper as required and greasing the metallic and mechanical serviceable parts.
Removing,cleaning,servicing, calibration, testing and commissioning of microprocessor based earth fault and over current fault relay of HT 11 KV VCB all as specified and directed by Engineer in charge.
Removing,cleaning,servicing, calibration, testing and commissioning of electro megnatic earth fault and over current fault relay of HT 11 KV VCB all as specified and directed by Engineer in charge.
Replace ment of Fuse carrier including HRC fuse upto 10 amps suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and directed by Engineer in charge.
Supply and fix in replacement push button switch suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and directed by Engineer in charge.
Supply and fix in replacement indicator lamp LED suitable for operating voltage 110/220 Volt for HT/LT Panel all as specified and directed by Engineer in charge.
Supply and fix 11 KV resin cast current transformer (250/5A) all as specified and directed by Engineer in charge.
Supply and fix 11 KV 3 phase potential Transformer dry type all as specified and directed by Engineer in charge.
M&L for Preparing the outer surface of VCB panel indoor type by removing the old paint/removing the rusting and denting and painting with two coats of sythetic anamel paint of approved colour complete as specified and directed by Engineer-in-charge.
M/L for cutting the bituminous road in the size not exc 0.4 mtr X 0.6 mtr for laying of UG cables and making good with the existing surfaces after laying the pipe/cable all as directed
Dismantling APFC panel carefully,removing the defective control device MCCB/MCBs,capacitors,indicator cum push button switches,relays,contacts,CTs,internal wiring, Cleaning all parts by CTC solution / emry paper as required and greasing the metallic and mechanical serviceable parts complete as specified and directed by Engineer-in-charge.
Supply and fix relays BR 6000 suitable for 6 stage APFC panel all as specified and directed by Engineer in charge. Make:EPCOS/NEPTUNE
Supply and fix relays BR 6000 suitable for 8 stage APFC panel all as specified and directed by Engineer in charge. Make:EPCOS/NEPTUNE
Programming and tuning of relays suitable for APFC panel all as specified and directed by Engineer in charge.
Supply and fix capacitor all as specified and directed by Engineer in charge.
Supply and fix fresher fan suitable for APFC panel all as specified and directed by Engineer in charge.
Supply and fixing (in replacement) of MCCB 4 pole 415 volts on pannel mounted type with breaking capacity 25 KA Magnetic thermal setting adjustable 70-100% including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity.
(a) MCCB four pole 415 volts 50 Hz , 63 amps, with rupturing capacity 16 KA
(b) MCCB four pole 415 volts 50 Hz , 100 amps, with rupturing capacity 16 KA
(c) MCCB four pole 415 volts 50 Hz , 160 amps, with rupturing capacity 36 KA
(d) MCCB four pole 415 volts 50 Hz , 250 amps, with rupturing capacity 36 KA
(e) MCCB four pole 415 volts 50 Hz , 320 amps, with rupturing capacity 36 KA
(f) MCCB four pole 415 volts 50 Hz , 400 amps, with rupturing capacity 36 KA
(g) MCCB foure pole 415 volts 50 Hz , 500 amps, with rupturing capacity 36 KA
Supply and fixing (in replacement) of MCB 3 pole 415 volts on pannel mounted type with breaking capacity 10 KA including disconnecting the incoming/outgoing cable connections and re-connecting with suitable aluminum lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity.
(a) MCB 32 Amps TP
(b) MCB 40 Amps TP
(c) MCB 63 Amps TP
(d) MCB 6-32 Amps SP
Supply and fixing (in replacement) of power contactor capacitor duty 3 pole 415 volts on pannel mounted type including disconnecting the incoming/outgoing cable connections and re-connecting with suitable copper lugs/ferruls etc. after taking out the existing u/s and making good the disturbed surface for following capacity.
(a) Contactor suitable for up to 12.5 KVAR
(b) Contactor suitable for above 12.5 KVAR to 20 KVAR
(c) Contactor suitable for above 20 KVAR to 25 KVAR
(d) Contactor suitable for above 33.3 KVAR to 50 KVAR
Supply and fix illuminated push button switch suitable for APFC Panel complete all as specified and directed
M/L for preparation of old steel surfaces of HT Feeder Pillar Box of any description, over 10cm in width or girth,not otherwise described and applying one coat of synthetic enamel paint complete all as specified and directed
Supply and fix mild steel chequered plate of size 5mm thick all as specified and directed.
Repair/Maintenance of LT Panel board / APFC panel any type and size by taking shut down,cleaning and removing of carbon particles, rubbing of heated portion of bus bar and cleaning complete and fine setting, tightening of all joints in bus bar, earthing etc and welding of broken doors including replacement of u/s nuts/bolts/washers and replacement of corroded glands, lugs/ thimbles and tightening them properly and testing all as directed. Note:- Spare parts for LT / APFC panel will be measured and paid separately.
Repair/Maintenance and complete over hauling of HT VCB’s including disassembling of operating mechanism parts, well cleaning with petrol CRC 226, replacing unserviceable parts and accessories like spring, gasket, coils, nuts, bolts and washers etc, oiling and greasing of moving parts, re-assembling, fine setting of mechanism, well cleaning and de-carbonizing of arc control pot, fixed and moving contact including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode including maintenance and well cleaning the complete, replacing unserviceable parts and components etc complete all as directed. Note:- Spare parts for VCB will be measured and paid separately.
SUPPLY ONLY THE FOLLOWING SPARES PARTS FOR SER ITEM NO 134 and 135
(a) Digital ammeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring. Make L&T, Cat No WDS301OCA00
(b ) Digital voltmeter flush type 96 sqmm with suitable fixing arrangement for easily fixing in existing LT panel including necessary wiring. Make L&T, Cat No WDV303FC000
(c) Indicator lamp assembly LED type (RYB) in existing LT panel with suitable wiring and volts.
(e) LT RG tape wounded current transformer up to 500/5, 10 VA with suitable connection and testing all as directed.
(f) LT RG tape wounded current transformer up to 250/5, 10 VA with suitable connection and testing all as directed.
(h) Capacitor bank long life 3 phase 440 volts of capacity 5 KVAr (Resin filled)
(j) Capacitor bank long life 3 phase 440 volts of capacity 10 KVAr (Resin filled)
(k) Capacitor duty contactor for APFC pannel 3 phase 440 v operating coil voltage 240 volts,32 Amps
(l) Spring Bushing for VCB breakar ON and OFF mechanisum in existing VCB panel complete all as specefied and directed.
(m) HRC Fuse of 10 Amps rated capacity suitable for HT VCB Panel complete all as specefied and directed.
(m) Heater suitable for HT VCB Panel complete all as specefied and directed.
(m) Name plate suitable for Incoming and Out going HT VCB Panel complete all as specefied and directed.
Repair/Maintenance and complete over hauling of 11 KV HT VCB control panel any size/capacity, well cleaning and de-carbonizing, including checking testing, tripping check of HT VCB’s making perfect operational in manual and electric mode etc complete all as directed.
Repair/Maintenance and complete over hauling of 11 KV HT PT , well cleaning and de-carbonizing, including checking, testing, making perfect operational etc complete all as directed.
Maintenance and complete calibration and setting as per fault level of HT VCB’s relay11 KV with suitable instrument including T&P etc complete all as directed.
Supply & fixing in replacement power factor controller relay 8 step 415 Volts, AC,50 Hz to automation to power capacitor including replacement of control wring as required at site including addition/alteration if required. Make L&T eta CON L8 Cat No ERPML08D500 or equivalent.
Supply & fixing in replacement 100 AH, 12V Maintanance free battery including replacement connecting materials such as terminals,lead, thimbles, lugs, nuts, bolts and washers as required at site all as specified and directed. Make:- Exide, Amco.
Supply, install & testing of constant current, constant voltage (CCCV) battery charging unit to charge 36 volts DC battery bank Suitable to accomadate 03 numbers 12 volts 100 AH batteries SCR controlled and consisting of double wound transformer an SCR/diode bridge, smoothing choke, capacitors and electronic circuits for controlling the voltage and current housed in a power coated sheathed steel cabinet not less than 2.0 mm thick suitable for floor mounting and fitted with a digital voltmeter & ammeter and the working voltage 180-270 volts. The charger should has indications for mains supply, mode of charging (float or boost), polarity batter reverse & over load conditions. The charger has protection for over load, short circuit, reverse polarity & surge/transient. The charge have to alarm on fuse blowing & short circuit. All protections to charger & its meter shall be provided with suitable rating MCB only including providing battery stand made out of MS tublerto accomadate 3 Nos battery and taking out old unserviceable complete all as specefied and as directed.
M & L for New earthing complete with Copper plate earth electrode 600X600X3mm thick buried directly in ground (earth pit not less than 2.25 meter below ground level) with top edge of the plate not less than 1.5 metre below normal ground level connected to 20x3mm copper strip at two points by means of bolts and nut, check nut and washers including charcoal dust, common salt, necessary excavation in hard/dense soil, returning filling in and removal of surplus soil to a distance up to 50metres, PCC pit in 1:3:6 type CI (using 20mm grade stone aggregate) RCC 1:2:4 type B-1 (using 20mm grade stone aggregate ) 50mm thick pit cover, reinforced with 8mm dia TMT bars 75mm c/c, both ways MS handle 12mm dia, GI funnel, wire mesh and GI watering pipe of 20mm bore GI (light grade) and earth lead protection pipe 40mm bore (light grade) all as specified, directed and shown in electrical plate No 3 of SSR Part-I including testing complete. Note : Copper strip and protection pipes 40 mm GI light grade up to 7.5 metre is included in unit rate and beyond that the same will be measured separately.
Supply & fixing for Copper strip 20x3 mm on wall with insulaters/batten or recessed or buried in ground all as directed
Material & Labour for Cement concrete in foundation, filling and mass concrete type B2 1:2:4 (40mm graded aggregate). Not exceeding 15 CM in deapth for plinth protaction for path including dismentling of old surface all as specified and directed.
Taking out existing LT/HT cable off sizes up to 300 Sqmm 2 to 4 core from duct/wall/floor/trenches and re-laying the same serviceable cable after fault rectification in existing position with supply and fixing connecting materials such as thimbles, lugs, nuts, bolts and washers as required at site all as specified and directed.
Taking down the unserviceable HT / LT cable of any size from trenches/ walls /floor etc Supply & laying of HT XLPE Insulated screened aluminium stranded conductor cable PVC bedded galvanized strip armoured heavy duty 11 KV cross sectional area 120 Sqmm 3 Core conforming to IS 7098 lead in duct/trenches complete all as specified and directed
Supply and fix heat shrinkable straight through cable jointing kit for 11 KV grade cable joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for indoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination heat shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sq mm complete all as specified and directed.
Taking down the unserviceable Lightning arresters and Supply and fix 11000 volt Lightning arresters expulsion type complete with all fittings, transmission class, dies-charge capacity 65 kilo amp complete all as specified and directed.
Dismantling and Taking out old unserviceable CT 11 KV and Supply and Fixing new Current Transformer 11 KV, 50-75/5-5 Amp, class 1.0 accuracy, protection 5P10 including cleaning of bus bar, nuts, bolts and washers etc, connecting and testing complete all as specified and directed.
Supply and fix 2 core 2.5 sqmm PVC insulated PVC sheathed weather proof multistranded aluminium conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed.
Supply and fix 2 core 1.5 sqmm PVC insulated PVC sheathed weather proof multistranded aluminium conductor cable 1100 volts grade drawn through in GI conduit, pole etc with MS clamps from junction box to street light fitting all as specified and directed.
Supply & fix aluminium lugs for 10 sqmm to 16 sqmm 4 core cable complete all as specefied and as directed
Supply & fix aluminium lugs for 25 sqmm to 35 sqmm 4 core cable complete all as specefied and as directed
Supply & fix aluminium lugs for 50 sqmm to 70 sqmm 3.5 core cable complete all as specefied and as directed
Supply & fix aluminium lugs for 95 sqmm to 120 sqmm 3.5 core cable complete all as specefied and as directed
Supply & fix aluminium lugs for 240 sqmm to 300 sqmm 3.5 core cable complete all as specefied and as directed
M & L for cross arms, bracings, supports, clamp and back plate fabricated from structural steel sections including nuts, bolts, washers, welding bending cold or hot, drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing of coat of paint including dismantling all as specified and directed.
Disconnecting and dismantling & complete overhauling of 11/0.433 KV Transformer capacity up to 500 KVA, after disconnecting of electric supply and earth connections including transportation to work shop, drained out transformer oil, lifting/removing of top cover of transformer & cores with chain pully blocks/crane, cleaning of sludge and washed down with the help of spray of clean oil and re-assembling of transformer with S&F of new gasket set assembly, replacement of nuts, bolts and washers as required, re filling of Transformer oil after centrifuging at satifactory dielectric strength complete after electric connections and testing all as specified and directed.
M&L for Filling of new transformer oil having dielectric strength not less than 60 KV complete including centrifuging of oil (if required) up to getting dielectric strength near 60 KV all as specified and directed.
M&L for replacement of HV copper coil and insulation complete all as specified and directed.
M&L for replacement of LV copper coil and insulation complete all as specified and directed.
M&L for reinsulation of existing HV copper coil complete all as specified and directed.
M&L for reinsulation of existing LV copper coil complete all as specified and directed.
M&L for Oven Drying complete all as specified and directed.
M&L for insulation of core,bushing,Tap changer and etc complete all as specified and directed.
Veera Electrical
G.L.THIRUMALAI NAIDU AND COMPANY
PSK Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .