Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.6 LAccepted-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L1 | Accepted-AOC Lowest Bidder | |
| 2 | L2₹29.0 L+₹4.0 L (15.9%)Rejected-Finance PLOT NO 32 FF SHIVAJI ENCLAVE NEW DELHI 110027 | NEW DELHI | NEW DELHI | DELHI | 110027 | L2 | Rejected-Finance Other than Lowest |
| Sl No | Description | Qty | Unit | P S TRADERS L1 | Singh Associates L2 |
|---|---|---|---|---|---|
| 1.00 | Material and labour for de-scaling of condensers of central AC plant capacity 3X270 TR by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at complete at Manekshaw Centre all as specified and directed.
Notes :-
(i) Necessary T&P such as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department.
(ii) Descalling of all condensers in one AC plant shall be considered as one job. | 2 | Each Job | 12,000 ₹24,000 Lowest | 15,000 ₹30,000 |
| 2.00Material and labour for servicing of AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure and coil shine solutions and jet of water pressure with pump without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:- | |||||
| 3.00 | 18000 CFM AHU | 4 | Each Job | 500 ₹2,000 Lowest | 1,400 ₹5,600 |
| 4.00 | 7000 CFM AHU | 2 | Each Job | 500 ₹1,000 Lowest | 749 ₹1,498 |
| 5.00 | 4000 CFM AHU | 4 | Each Job | 500 ₹2,000 Lowest | 850 ₹3,400 |
| 6.00 | 8000 CFM AHU | 12 | Each Job | 500 ₹6,000 Lowest | 900 ₹10,800 |
| 7.00 | 14000 CFM AHU | 16 | Each Job | 500 ₹8,000 Lowest | 1,200 ₹19,200 |
| 8.00 | 22000 CFM AHU | 6 | Each Job | 500 ₹3,000 Lowest | 1,850 ₹11,100 |
| 9.00 | 6000 CFM AHU | 12 | Each Job | 500 ₹6,000 Lowest | 849 ₹10,188 |
| 10.00 | 13000 CFM AHU | 4 | Each Job | 500 ₹2,000 Lowest | 1,249 ₹4,996 |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
21 Oct 2025, 6:00 pmClosed
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
GE UTILITY PLANT AND MACHINERY KIRBY PLACE DELHI CANTT-10
REPAIR MAINTENANCE OF KITCHEN TOILET EXHAUST SYSTEM FIRE DETECTION SYSTEM AND OTHER MISC WORKS OF MANEKSHAW CENTRE UNDER GE (U) PM DELHI CANTT10
2025_MES_732276_1
GE(U)/PM/D-44/2025-26
Open Tender
Miscellaneous Works
Item Rate
240 days
Delhi Cantt
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE UTILITY PLANT AND MACHINERY DELHI CANTT-10
₹80,000
Yes
1 Dec 2025
23 Sept 2025
23 Oct 2025
23 Sept 2025
21 Oct 2025
7 Oct 2025
Amount
Material and labour for de-scaling of condensers of central AC plant capacity 3X270 TR by opening side plate, flushing the condenser tubes using de-scaling solution, Roding the condenser tubes carefully removing all the deposited materials completely and raising the solution through condenser tubes till clear water starts to come out from the condensers as complete including re-fixing the side plates by replacing gaskets & testing complete for satisfactory working at complete at Manekshaw Centre all as specified and directed. Notes :- (i) Necessary T&P such as pump, tube, descaling solution etc shall be arranged by the contractor without any extra cost to Department. (ii) Descalling of all condensers in one AC plant shall be considered as one job.
Material and labour for servicing of AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure and coil shine solutions and jet of water pressure with pump without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
18000 CFM AHU
7000 CFM AHU
4000 CFM AHU
8000 CFM AHU
14000 CFM AHU
22000 CFM AHU
6000 CFM AHU
13000 CFM AHU
13500 CFM AHU
11000 CFM AHU
Material and labour for servicing of ceiling mounted AHU unit including cleaning of bottom tray and cleaning of cooling coil complete with high pressure vaccum cleaner without damaging cooling coils and fins and remove all the scale and foreign material deposited in side the coil followed with air pressure to sweep up all the particles and ensure through flow of air over the cooling coil, checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc all as directed for following capacity AHU:-
6000 CFM ceiling mounted AHU
8000 CFM ceiling mounted AHU
5000 CFM ceiling mounted AHU
3000 CFM ceiling mounted AHU
2000 CFM ceiling mounted AHU
2500 CFM ceiling mounted AHU
Supply and fixing in repair of AHU Shaft bearing (02 Nos in each) of size for following capacity AHU as per site requirement complete all as specified and directed.
18000 CFM AHU
7000 CFM AHU
4000 CFM AHU
8000 CFM AHU
14000 CFM AHU
22000 CFM AHU
6000 CFM AHU
13000 CFM AHU
13500 CFM AHU
11000 CFM AHU
3000 CFM ceiling mounted AHU
2500 CFM ceiling mounted AHU
2000 CFM ceiling mounted AHU
Supply and topping up Refrigerator Gas R-134A complete all as specified & directed. Make:- Mefron/ Floron/ Refron
Material and labour for Dismantlingthe one side puff panel of AHU and then diconnecting the chiller pipe and cooling coil of AHU of required and then Supply and fixing in replacement of bottom tray for fan and coil section of AHU of any size and any capacity made out of SS sheet tray of grade 304 and also including 25mm thick thermocol insulation covered with tarfelt for AHU bottom complete all as specified and directed.
Supply and fixing in replacement of shock absorbing rubber pads at the bottom of the AHU unit for absorbing shocks and vibrations, heavy duty of suitable size as per ground requirement complete all as speicifed and directed.
Supply and fixing in replacement of Pre filter 10 micron of size 610mm x 610x 50mm made of out of GI wire mesh interspaced with two crimp layers and three flat layers flanged deep box type and efficiency 90% as per existing size and pattern for the AC Plant air handling unit complete all as speicifed and directed. Make:- Thermodyne/ AAF or equivalent as approved by Accepting Officer
ditto- all as per item No.37 above but size 610mm x 300mm x 50mm.
ditto- all as per item No. 37 above but size 300mm x 300mm x 50mm.
ditto- all as per item No. 37 above but size500mm x 450mm x 50mm.
ditto- all as per item No. 37 above but size 500mm x 500mm x 50mm.
ditto- all as per item No. 37 above but size 500mm x 400mm x 50mm.
Supply and fixing in repair bimetallic thermal overload relay, 9 to 15 Amps complete as specified and directed.
Supply and fixing in repair bimetallic thermal overload relay, 14 to 23 Amps complete as specified and directed.
Supply and fixing in repair bimetallic thermal overload relay, 20 to 33 Amps complete as specified and directed.
Supply and fixing in repair bimetallic thermal overload relay, 24 to 40 Amps complete as specified and directed.
Supply and fixing in replacement of Rubber Tyre Coupling (TC-14) set for chiller / condensor pump motor complete all as specified and directed.
Supply and fixing in replacement of Rubber Tyre Coupling (TC-13) set for chiller / condensor pump motor complete all as specified and directed.
Supply and fixing in replacement of Rubber Tyre Coupling (TC-11) set for chiller / condensor pump motor complete all as specified and directed.
Supply and fixing in replacement of multifunction electronic timer ( 0 to 60 Sec) type Series 525 complete all as specified and directed. Make:- Siemens/L&T/ ABB
Material and Labour for frame work with angle iron for frame support, with fabrication, welding joining including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 including taking down old unserviceable one complete all as specified and as directed.
Material and labour for repairing /servicing Condenser or Chiller pump (Centrifugal pump) of following capacities by disconnecting the pump from motor, opening for inspection, replacing the worn out parts like gland bush, bearings, gland bolts and nuts, gland packing, gasket, water seal etc including repairing to pump shaft by remetalling, grinding, polishing and reassembling complete pump & refixing in same position & connecting including replacing the rusted nuts, bolts, washers etc and testing and commissioning including loading/unloading and transportation to & from authorised workshop complete all as specified and directed: -
Condenser or Chiller Pump of capacity 30 HP
Hotwater generator Pump of capacity 25 HP
Disconnecting from mains/taking out existing unserviceable/defective motor of following capacity of any size, type, and make including disconnecting all electrical connections removing from foundation transporting to repair workshop disconnecting unserviceable burn out winding completely including insulating materials and rewinding of the complete stator with super enameled copper wire of existing size applying proper insulation ‘F’ class varnish drying in oven, assembling, transporting back to site, re-installating, testing and commissioning complete all as specified and as directed.
Condenser or Chiller Pump of capacity 30 HP
Hotwater generator Pump of capacity 25 HP
Material and labour for repairing/ servicing AHU Fan Motor/ exhaust AHU of following capacity, opening the motor, cutting & removing old burnt winding wire, rewinding the motor with new super enamelled copper winding wire of size & description to match with existing including insulating materials, varnishing, drying, replacement of both driven end, non driven end bearings and base plate, reassembling, refixing in same position & connecting including testing and commissioning complete all as specified & directed :-
2 HP Motor
3 HP Motor
5 HP Motor
7.5 HP Motor
10 HP Motor
15 Hp Motor
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-32 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. Make :- L&T/Siemens/ ABB/ C & S
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-25 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. Make :- L&T/Siemens/ ABB/ C & S
Supply, fixing and testing in replacement of three pole power contactors of capacity MNX-18 including NO or NC auxiliary contact block, coil voltage 230 V ,control wiring, thimbles, etc and including taking down of old one complete all as specified and as directed. Make :- L&T/Siemens/ ABB/ C & S
Supply and fixing in replacement Rigid UPVC piping of following dia complete with fittings, supports as per specifications and duly insulated with 6mm thick closed cell nitrile rubber insulation. Make :- Supreme/ Finolex/ Prayag
40mm dia
32mm dia
Supply and fixing in replacement over load relay 30-50 Amps complete all as specified and directed. Make :- L&T/Siemens/Legrand/ ABB/ C & S
Supply & fixing in replacement brass terminals of follwing ways complete all as specified and directed.
Material and labour for control wiring with 6 core X 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 50 mm dia as per IS 694 complete all as specified and directed Make of wire :-Finolex/Havells/Polycab, Make of PVC rigid conduit :- Finolex/ Supreme/ Presto Plast
Supply & fixing in replacement single phasing preventer type VSP2 complete all as specified and directed. Make :- Minilec/ L&T/ Siemens/Legrand/ ABB/ C & S
Material and labour in replacement of unserviceable 3 way modulating motorized valve with Teflon gland, with linear movement actuator 24 V AC input supply, 0-10 V input signal with modulating thermostat & transformer of following sizes complete all as specified and directed. Make :- Honeywell/ Siemens/ Indfoss/ Johnson
32mm dia
65mm dia
50 mm dia
40 mm dia
80 mm dia
100 mm dia
Supply and fixing in replacement Water temperature sensor suitable chiller units of 270 TR as per existing model and make complete all as specified and directed.
Supply and fixing in replacement Air Vent valves made out of brass of size 15mm dai for chiller chiller pipe line complete all as specified and directed.
Supply and fix exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250/300m complete all as specified and directed.
Supply and fixing in replacement cast iron Y strainer flenged ends with SS perforated sheet screen of following size complete all as specified and directed. Make : Advance/ Audco/ Learder/ castle/ Nur/ Zoloto
100mm dia
150mm dia
200mm dai
32mm dai
65mm dia
50 mm dia
80 mm dia
Supply and fixing in replacement cast iron butterfly valve lever operated SS disc type nitrile/ EPDM rubber lining PN16 of following size complete all as specified and directed. Make :- ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO
200 mm dia.
150 mm dia.
125 mm dia.
100 mm dia.
80 mm dia.
50 mm dia.
65 mm dai
Supply, Laying, jointing and testing of under electric cable XLPE insulated, 1100 volt grade heavy duty armoured with stranded aluminium conductor laid in trenches/duct/pipe including all electrical connection with required lugs and nuts, bolts complete all as specified and directed. Make :- Finolex/ Havells/ Polycab
4 core 10 Sqmm
4 core 16 Sqmm
4 core 25 Sqmm
3.5 core 35 Sqmm
3.5 core 50 Sqmm
3.5 core 70 Sqmm
3.5 core 95 Sqmm
Supply and fixing in replacement motorized spring return actuator for device with control panel and temprature sensor complete all as specified and directed.
Supply , installation, testing and commission in replacement of fire dampers complete with smoke detector/ thermister linkage etc and actuator as required for operation complete all as specified and directed.
Supply and fixing MS damper of size 450mm X 450mm of supply diffuser complete all as specified and directed.
Material and labour for control wiring with 4 core X 4 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. Make of wire :-Finolex/Havells/Polycab , Make of PVC rigid conduit :- Finolex/ Supreme/ Presto Plast
Material and labour for control wiring with 4 core X 6sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 40 mm dia as per IS 694 complete all as specified and directed Make of wire :-Finolex/Havells/Polycab, Make of PVC rigid conduit :- Finolex/ Supreme/ Presto Plast
Material and labour for control wiring with 2 core X 1.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed. Make of wire :-Finolex/Havells/Polycab , Make of PVC rigid conduit :- Finolex/ Supreme/ Presto Plast
Material and labour for control wiring with 2 core X 2.5 sqmm , FRLS PVC round insulated and sheathed wire featuring a bright annealed bare copper conductor cable 1100 Volts grade with multi stranded, wire colour black, drawn through concealed conduit including PVC rigid conduit medium grade 32 mm dia as per IS 694 complete all as specified and directed Make of wire :-Finolex/Havells/Polycab, Make of PVC rigid conduit :- Finolex/ Supreme/ Presto Plast
Material and labour For Providing, fixing, testing and commissioning in replacement of Duct mounted inline fans of G.I. construction, complete with centrifugal fan Size 315mm dia complete as specified and directed. Make :- Otsberg(model No. CK315C)or equivalent in ZECO, EDGEtech.
Supply and fixing in replacement bakelite terminal plate of 6 way including brass studs, bolts and nuts etc suitable to match any make of 3 phase electric motors and capacity up to 30 HP complete all as specified and directed.
Supply and fixing in replacement thermometer suitable for condenser water line with suitable housing for mounting on pipe line 0-50°C complete including taking down old unservicable thermometer all as specified and directed.
Supply and fixing in replacement Compound pressure gauge (Discharge pressure) of size 100 mm dia suitable for 0 to 300 PSI complete including taking down old unservicable pressure gauge all as specified and directed.
Supply and fixing in replacement indicator lamp assembly complete LED type suitable for the existing system supply voltage 230V / 440V AC complete all as specified and directed . Make :- MIMIC CONTROL/ GE CONTROLS / RR MICRO / L&T / SIEMENS/ BCH/ SCHNEIDER
Supply and topping up Compressor Oil RL-170 H complete all as specified & directed. Make :- HPCL(Seetal)/ HP (Seetal)/ Servo
Material and labour for servicing of Exhaust AHU of capacity up to 10000 CFM including cleaning of bottom tray and with air pressure to sweep up all the particles and checking aligning and tightening of blower fan, greasing of all movable parts, replacement of worn out bolts, nuts shaft keys etc complete all as specified and directed.
Supply and fix in replacement Galvanised iron strip 32X6 mm as earth continuity conductor including fixing arrangement on suitable size insulator complete all as specified and directed.
Material and labour earthing complete with GI plate electrode of size 600 x 600 x 6 mm thick bured directly in ground vertically at a depth not less 2.25 mtr below normal ground level with top edge of earth plate at a depth not less than 1.5 mtr below normal ground level surrounded from all sides by 1.5 cm thick packed layer of charcoal of dust and common salt filling in alternate layers and making electrode connection by using GI strip of size 32X6 (up to 7 meter GI strip included) mm by means of bolts nuts check nuts and washers made of brass and earth strip protected by light grade 40 mm dia GI Pipe upto test point and connected to main switch board are main controlled board with provision of GI pipe medium grade 20mm bore for watering including funnel wire mass RCC pit cover and PCC Chamber pit with 1:2: 4 type C2 (including excavation earth work) all as specified and shown on plate No 5 of SSR Part-1.
Supply, install, testing and commissioning in replacement of Duct insulation with 25mm thick Nitrile Rubber insulation of class "o" fire retardant with Mechanical protection over insulation with fiber glass cloth & UV paint (for exposed duct) for Ducts installed outside, (exposed to sunlight) complete all as specified and directed.
Supply and fixing in repair MCB TP 63 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply and fixing in repair MCB TP 40 Amps, capacity 10 KA, C curve including taking down old unsv one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Material and labour for preparation of surfaces of Central AC Plant of capacity 3 x 270 TR at Manekshaw Centre for painting of trap door, condensers,chillers,compresors, Induction motors, pumps, hot water boiler, C channels, all pipe lines, valves and outer body of cooling towers and AHU's with different colors following the color code system as directed by the Engg charge. Job includes removing the old paint by rubbing, brushing and applying one coat of red oxide zinc chrome primer and two coats of Synthetic Enamel Paint (1st grade quality) complete all as specified and directed. Make of paint and primer :- ASIAN/ BERGER/ JENSON & NICHOLSON/ SHALIMAR
Supply & fixing MCCB 4 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed. Make:- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 4 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA with thermal magnetic release including taking down old unserviceable one complete all as specified and directed.Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 100 Amps, 50 Hz, 415V with rupturing capacity of 16 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. Make:- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 63 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 4 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed.Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 125 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 4 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 160 Amps, 50 Hz, 415V with rupturing capacity of 25 kA including spreader terminals including taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 200 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply & fixing MCCB 3 Pole of capacity 250 Amps, 50 Hz, 415V with rupturing capacity of 35 kA including spreader terminals with taking down old unserviceable one complete all as specified and directed. Make :- L&T/ Siemens/Legrand/ ABB/ C & S
Supply and fixing in replacement V-belt of size SPA-1120 complete all as specified and directed.
ditto- all as per item No. 143 above but size SPA-1750
ditto- all as per item No. 143 above but size SPA-1850
ditto- all as per item No. 143 above but size A-1610
ditto- all as per item No. 143 above but size SPA-1800
ditto- all as per item No. 143 above but size B-2350
ditto- all as per item No. 143 above but size A-1630
ditto- all as per item No.143 above but size SPB-1320
ditto- all as per item No. 143 above but size SPA-1550
ditto- all as per item No. 143 above but size A-2270
ditto- all as per item No. 143 above but size SPA-900
Material and labour for replacement of chilled water pipe line insulation on MS class 'C' pipe insulation of size 50 to 100 mm dia inside the building but excluding valves/strainers/pr gauges etc and adequately supported on rigid supports and duly insulated with closed cell elastometric nitrile rubber of class 'O' insulation and insulation applied by adhesive confirming to standard OEM specifications secured with 0.63 mm GI sheet cladding complete at the joints and repairing of damage to the buildings if any etc as per specifications and as required complete in all respects
All same as of intem No. 154 but pipe of size 100mm to 200mm
Supply and fixing in replacement 80 mm dia cast iron non return valves of pressure class PN 1.6 including nuts, bolts, washers, gaskets, etc for Central type AC plants complete all as specifed and directed. Make :- ADVANCE/ AUDCO/ LEADER/CASTLE/ NVR/ ZOLOTO
ditto- all as per item No. 156 above but 100mm dia
ditto- all as per item No. 156 above but 150mm dia.
Ditto- all as per item No.156 above but 250mm dia.
Supply, Installation , Testing and commissioning in repair of perfabricated type cable tray of size 45mm wide x 50mm x 1.6mm fabricated out of perforated hot dip galvanized sheet of minimum 1.6mm thick with 50mm flange to be installed horizontally or vertically. The cable tray shall be complete including cost of bends, elbows, cross, tees, reducers etc. site condition and rate shall include cost of anchor fastners, screw, nuts, bolts and misc. and other fixing hardware painting of support structure etc as required complete all as specified and as directed.
All as per Item No.160 above but of size 75mm wide x50mm x 1.6mm complete all as specified and as directed.
All as per Item No.160 above but of size 150mm wide x50mm x 1.6mm complete all as specified and as directed.
Material and labourfollowing in replacement of powder coated extruded aluminum rectangular diffusers complete with black anodized extruded aluminum Volume control damper (wherever specified), nuts, bolts, screws etc.complete as required at site all as specified and directed.
Supply only for air diffusers (outer size 305mm X 305mm) of required sizes with volume control damper.
Supply only for air diffusers (outer size 610mm X 610mm) of required sizes with volume control damper.
Supply only for return air diffusers(outer size 150mm X 105mm) of required sizes without volume control damper
Supply only for return air diffusers(outer size 305mm X 305mm) of required sizes without volume control damper
Supply only for return air diffusers(outer size 610mm X 610mm) of required sizes without volume control damper
Material and labour for Supply & Fixing of powder coated extruded aluminum supply & return grilles complete with nuts, bolts, screws etc. to make the system complete, as required at site all as specified and directed.
Material and labour in replacement of thermal insulation material for non-exposed Ducts with closed cell class o nitrile rubber elastomeric insulation of density 40-60 Kg/m3 thermal conductivity of 0.033-0.038 W/mk and µ>=7000 (k-flex st) to be applied on ducts using manufacturers recommended rubber based adhesive as per the approved specification the material shall be from global approved brands & UL approved for new ducts as required at site complete all as specified and directed.
(b) 19 mm thick
(a) 25 mm thick
Material and labour for Supply, installation, testing and commissioning in replacement of flexible fire retardant canvas connector cloth including flanged from both side with inspection chain in it removing of old one complete all as specified and directed.
Supplyand fixing in replacement rubber mat LT 1.1KV volt grade 1mtrx 2mtr x 10mm
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 35 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 75 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 95 Sqmm complete all as specified and directed.
Supply & fixing in replacement aluminium lugs for cable of cross sectional area 120 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 10 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 16 Sqmm complete all as specified and directed.
Supply & fixing in replacement copper lugs for cable of cross sectional area 25 Sqmm complete all as specified and directed.
Material and labour for maintenance of AHU supply panel / feeder pillar/LT panel indoor/outdoor type including removing the carbonized/melted sparked thimbles, cleaning the carbonized bus bar making cable ends fresh and supply and crimping new thimbles/lugs and fixing the cable on bus bar/MCCB/Main switch/MCB including providing new nut bolts and washer if required greasing the doors of feeder pillar/LT panel outdoor/indoor type complete all as specified & directed.
Attending complaint of control panel wiring and making it fully serviceable with and including PVC tape, PVC tie, Nut bolt, and other items complete all as specified and directed. Notes: - After intimation of breakdown by Engineer in Charge/JE E&M through telephone or verbally, the contractor shall arrange the Mechanic to attend the complaint within 2 hours and make the plant functional. If contractor failed to attend complaint with in time frame, a penalty of Rs 400/- per Hrs per complaint shall imposed on contractor and shall be recovered from contractor's dues
Cleaning of inside surface of supply ducts of HVAC (minimum open area of duct 1.00Sqm and maximum area 16.00Sqm) system of any area using high power vacuum air compressor robotic camera, air hammer, special nozzles, air sweep with other required accessories given/showing inspection of dust before and after cleaning of duct using colour video inspection complete all as specified & asdirected.
Material and labour for servicing of LT ACB 1600 Amps, 1200 Amps or 600 Amps draw out type 415 volts, 50 Hz, brushing, greasing and tightening of nuts and bolts fixed and moving contacts for smooth functioning and replacing of minor accessories complete all as specified and directed.
Material and labour in repair of site fabricated GSS Sheet metal, rectangular/round ducting complete with neoprene rubber gaskets,elbows,splitter damper vanes,hangars,supports as per approved drawings and specifications of following sheet thickness complete all as specified and directed. Make :- Sail/ Tata/ Jindal
Thickness of sheet (24 gauge)
Thickness of sheet (22 gauge)
Inspection, checking, cleaning, testing and commissioning of fire alarm cum fire detection system complete including fire detectors, smoke detectors, heat detectors, response indicators, wiring etc. through trained/experianced technician of OEM, the system and carry out planned maintenance in systematic and controlled manner at Manekshaw centre building complete except new server room all as specified and directed.
Notes for Serial item No.192 (a) Fire Alarm control panel:- These shall be kept clean by checking for its controls, indicating equipment’s system and all operations/fault indicators including checking of panel circuits for its healthiness and including of healthy battery/UPS/battery charger system. (b) Smoke Detectors & Fire Detectors: - All smoke/fire detectors shall be removing dust/dirt accumulated on them due to local ambient conditions. These shall be tested & cleaned once in a quarterly and report shall be maintained as directed by Engineer-in-Charge duly signed by user and concerned JE/Engineer-in-charge. (c) Response Indicators, Manual Call Point and Hooter: All items which are installed inside a cabin, room or above ceiling shall be tested by actuating the particular detectors as informed so as to ensure proper functioning of indicator. (d) Wiring and cables:Complete wiring shall be inspected jointly by contractor, MES rep and users so that structure or occupancy changes doesn't damage the cable/wiring/trigger device (Manual call points smoke heat ionization detector etc) (e) During attending complaint and maintenance check any spares/items required for replacemnet will done by the technician of OEM (i.e detectors, panels, response indicators, hooters wiring, battery) shall be measured under separate items. (f) Deployed Technician/mechanic fully equiped with necessary tools and plants are deemed to be included in the quoted rate. (g) Arrangement of testing equipment provided by the contractor deemed to be included in quoted rates. (h) The contractor deemed to have visited the site and seen the scope of work before quoting the rates. (i) The rates for making necessary arrangement of scaffaolding/ ladders is deemed to be included in the quoted rates. (j) Any damage to smoke and fire detection system during maintenance shall be repaired by the contractor at his own cost.
Checking and attending day to day complaints by means of finding the faults only related to fire alarm, detectors, hooters, response indicators, wiring and all other accessories and fixtures maintained by the department complete all as specified and directed.
Supply and fixing of Multi Detector, optical type low current draw, wide operating voltage 8 to 30 VDC, Bi-colour LED detector status indicator, Automatic drift compensation, tested and approved to EN54 - 7:2000 (Amendment 1) including taking down old unserviceable one complete all as specified and directed. Make :- APPOLO / EDWARD / SEIMENS /HONEYWELL
Supply and fixing of response indicators with MS Box 16 SWG and plastic cover including taking down old unserviceable one complete all as specified and directed. Make :- APPOLO / EDWARD / SEIMENS/AGNI
Supply and fixing of maintanance free battery 7 AH, 12 Volts with 8 Hours backup and 12 months warranty including taking down old unserviceable one complete all as specified and directed. Make :- EXIDE/ AMARON/ STANDARD FURKKAVA
Supply and fixing of PVC conduit pipe medium grade size of 25mm including taking down old unserviceable one complete all as specified and directed. Make :- Kalinga/ Polycab/Finolex/ Havells/ Anchor
Supply and fixing of multi-stranded copper conductor cable 1.5 Sq. mm nominal cross-sectional area, two core, PVC insulated and unsheathed FRLSH cable 1100 volts grade for sub main wiring including taking down old unserviceable one complete all as specified and directed. Make :- Havells/Polycab/Finolex/ RR Kabel
Material and labour for rectification, maintenance of addressable zones, searching the faults, up/down loading software of main control panel at Manekshaw center and reprogramming entire system and testing by authorized Technical Engineer of OEM complete all as directed by Engr-in-charge. and including Inspection, testing and commissioning of complete fire alarm system installed done by authrized OEM of Honeywell manufacturer only all as required complete all as specified and directed.
Supply, fixing, commissioning and testing of automatic Floating Sensitivity type Analog addressable Acclimate Photo thermal smoke detector with mounting based LED, Address Switch from 01-159 , to programme the detectors, complete as required. (In Changing Environment Area) ul- 7th edition including taking down old unserviceable one complete all as specified and directed. Make :- NOTIFIER/ GST/APPOLO/ EDWARD/HONEYWELL
Supply, fixing, commissioning and testing of analog addressable Rate of Rise Cum Fixed temperature detector with mounting based LED, Address Switch from 01-159 , to programme the detectors complete as required. Ul- 7th edition including taking down old unserviceable one complete all as specified and directed. Make :- NOTIFIER/ GST/APPOLO/ EDWARD/HONEYWELL
Supply,fixing,testing and commissioning of addressable type fault for isolating module shorted, dewired and loose circuits between two successive fault isolators with automatic resetting arrangement (base Model) including taking down old unserviceable one complete all as specified and directed. Make :- NOTIFIER GST/APPOLO/ EDWARD/HONEYWELL
Supply and fixing of addressable control modules for Hooters / Sounders / Strobes etc. including taking down old unserviceable one complete all as specified and directed. Make :- NOTIFIER/ GST/APPOLO/ EDWARD/HONEYWELL
Supply and fixing of Strobe Lights Cum Hooter with 110 cd. The strobes shall be synchronized for better evacuation including taking down old unserviceable one complete all as specified and directed. Make:- NOTIFIER/ GST/APPOLO/ EDWARD/HONEYWELL
Supply and fixing of manual call point including taking down old unserviceable one complete all as specified and directed. Make :- NOTIFIER/ GST/APPOLO/ EDWARD/HONEYWELL
Supply and fixing in replacement of linear BEAM type smoke detector consisting of a combined transceiver unit and an accompanying reflector which is to be fitted with all technical specifications as under :- 1. The distance between opposite walls is to be kept between 10 and 80 m from one another. If required, special additional stable ball joint units may be used to ensure that they are precisely fitted. The infrared beam that is emitted by the transmitter and is to be bounced back by the reflector and to be evaluated by the receiver. This is to be done by measuring the absorption of the infrared beam and of the smoke or fire modulation. The detectors shall get individually adapted to local conditions in the event of there being difficult visible conditions like strong interference from foreign light sources, reflections or very short monitoring distances etc. The beam detector shall be connected to the loop line via. individual monitor/ IO module to enable the detector being addressable and it shall operate in separate DC supply of 12 – 24 V
Singh Associates (BID ID -3454302)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.43 MB
D44TENDER.pdf
Tender Documents • 1.06 MB
D44SCHOFCREDIT.pdf
Additional Documents • 0.51 MB
BOQ_819885.xls
BOQ • 0.37 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .