Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance H 13 GEETANJALI PARK WEST SAGARPUR NEW DELHI 110046 | NEW DELHI | DELHI | 110046 | Admitted-Finance |
| 3 | Admitted-Finance PLOT NO 160 2 KH NO 443 NASIR PUR VILLAGE SOUTH WEST DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | Admitted-Finance |
| 4 | Admitted-Finance | Admitted-Finance |
Tender Value
₹25.8 L
EMD Value
₹51,560
Closing Date
1 Sept 2021, 6:00 pmClosed
GE AF SUBROTO PARK DELHI CANTT
GE AF SUBROTO PARK DELHI CANTT - 110010
REPAIR MAINTENANCE AND REPLACEMENT OF FIRE ALARM SYSTEM SMOKE DETECTORS AND CONNECTED WORKS AT VARIOUS OTM AND MAP MD ACCN AT CAMERO AREA UNDER GE AF SUBROTO PARK
2021_MES_464741_1
GE/SP/TOKEN-23/2021-2022
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE AF SUBROTO PARK DELHI CANTT
AS PER TENDER
7 documents required · 7 mandatory
₹500
GE AF SUBROTO PARK
₹51,560
Yes
15 Sept 2021
3 Aug 2021
3 Sept 2021
3 Aug 2021
1 Sept 2021
11 Aug 2021
4 Aug 2021 - 10 Aug 2021
Amount
M&L for repairs rectification / comprehensive maintenance , replacement of faulty service parts of complete fire alarm system installed in CHOC, HQ WAC BLDG, ARMOURY BLDNG all as specified and as directed by Engineer-in-charge. NOTE FOR ITEM NO 1 ABOVE :- ALL DEFECTIVE PART WHICH ARE REQUIRED TO REPLACE SHALL BE MEASURED AND PAID SEPERATELY UNDER RESPECTIVE ITEMS AS SUPPLY ONLY (a) FIRE ALARM CONTROL PANEL : The functions of controls panel and indicating equipment will be checked by the operation of a trigger device in each zone. All fault indicator and their circuits will be checked by stimulation of fault conditions (b) HEAT DETECTOR : Heat detectors will be tested by aim a heat lamp, blow-dryer, or heat gun at the heat detector. The detector alarms should sound within three or four seconds after apply the heat source. (c) SMOKE DETECTOR : Smoke detector will be cleaned periodically so as to remove dust or dirt that accumulates on them due to local ambient conditions at least each detector is cleaned once in month. Smoke detectors will be tested by apply a small spray of smoke detector test aerosol. The detector alarms should sound within three or four seconds after apply the heat source. (d) MANUAL CALL POINT HOOTERS : All manual call points will be operated once a monthly by removing glass or by actual breaking of glass so as to ensure that system is capable of operation under alarm conditions and all hooters give proper sound (e) RESPONSE INDICATORS : All detectors which are placed in side a cabin of room will be tested by initiating the particular detector so as to ensure the proper working of response indicator (f) WIRING & CABLES : A visual inspection will be made so that structure or occupancy changes does not damage cables and sitting of trigger devices (manual call points smoke detector and heat detector. (g) MONTHLY LOG SHEET WILL BE MAINTAINED FOR MONTHLY INSPECTION AND TESTING : Monthly inspection and testing will be done in the monthly maintained log sheet. Log sheet will be produced to the Engineer-in-charge duly complted on Ist day of every month. NOTE :- (a) Replacement of parts will be measured and paid seperately. (b) If service is not carried out by the contractor on due date Rs 1000.00 per day for each service recovery will be made. (c) Contractor will provide One Technician and One helper from 0900 to 1700 hrs in all working days for day to day services. (d) The maint shall be carried out through manufacturer representative or his authorised rep.
Supply and fix in replacement of microprocessor based automatic fire alarm control panel with power supply & battery charger having battery box for 2 Loop Micro processor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing maximum 99 detectors and 99 modules ) fire alarm/detection control panel. The panel shall be able to give location of all fire/fault conditions of addressable units via the address codes. Further, the panel must be able to automatically switch ON /OFF respective control module whenever any alarm is triggered. The panel shall have rectifier, Loop cards, 80 character L C D unit to indicate Fire/Fault Signal with address and analog output, external/inbuilt printer to log all fire or fault events complete in all respects.The Panel Shallbe Sheet Steel Painted, scaled to IP30. The Panel Shall have 20 Zones with Individual LED Indicators, expandable to 80 LED Indicators. The Panel Shall have 3 Serial Ports.complete all as specified and directed by Engineer in Charge. Make :- Honeywell Note: The total nos of DC battery of for item above, the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
Supply and fix in replacement of microprocessor based automatic fire alarm control panel supply & battery charger having battery box for 2 Loop Micro processor based 2 wire fault tolerant loop, required loop networkable type (each loop accessing maximum 99 detectors ande 99 modules ) fire alarm/ detection control panel. The panel shall be able to automatically switch ON/OFF respective control module whenever any alarm is triggered. The panel shall have external/ inbuilt printer to log all fire or fault events complete in all respects. The Panel shall be sheet steel painted, painted scaled to IP30. The Panel shall have 20 zones with individual LED indicators, expandable to 80 LED indicators. The Panel shall have 3 serial Ports complete all as specified and directed by Engineer-in-Charge. Make - Honeywell. Note :- The total nos of DC battery of for item above the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
Supply and fix in repplacement of microprocessor based automatic fire alarm control panel with power supply & battery charger having battery box for 2-8-Loop-Panel-Fire-Alarm-Control-Pane Intelli-Sense graphical LCD user interface and support for up to 200 fire zones by default allowing full EN54 compliance without additional hardware complete all as specified and directed by Engineer in Charge. Make :-Cease Fire Note: The total nos of DC battery of for item above, the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
Supply and fix in repplacement of microprocessor based automatic fire alarm control panel with power supply & battery charger having battery box for 12 Zone conventional Panel , Zone wise LED Light zone wise isolation facility complete all as specified and directed by Engineer in Charge. Make :-System Sensor Note: The total nos of DC battery of for item above, the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
Supply and fix in repplacement of microprocessor based wireless automatic fire alarm control panel with power supply & battery charger having battery box for HFP AP-AS Analogue Addressable Fire Control Panel. HFP AP-AS supports Hochiki ESP loop drivers, which are all capable of providing up to 400 milliamps of loop current for the most demanding applications.An integral 3 Amp power supply and temperature compensated battery charger provides ample power for the two, 1 Amp rated standard sounder outputs, loop powered sounders and other devices complete all as specified and directed by Engineer in Charge. Make :-Hochiki Note: The total nos of DC battery of for item above, the rating and capacity as recommended by the OEM shall be included in the scope and the cost there of shall deemanded to be included in the item rates.
Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable MuliticriteriaType Detector Complete with Dual LED, Hard Addressable Having rotary decade Address swicthes from 01-99, complete with Mounting Base Complete as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB//UL as required Conforming to BS 5839 Standards and Duly Approved by EN54/LPCB//UL. complete all as specified and directed by Engineer-in-Charge. Make : HONEYWELL
Supply and fixing in replacement of Wireless Smoke Detector Advanced dual path optical chamber design Internal algorithm processing optimises performance Designed and tested as per EN 54-7 & EN 54-25, certified by IMQ complete all as specified and directed by Engineer-in-Charge. Make : Hochiki
Supply and fixing in replacement of Wireless Wireless Intelligent Multi Sensor with a patented smoke chamber and thermistor heat sensing element. The sensor is fitted with a single omni-directional LED and a reed switch facility allowing testing using a magnet complete all as specified and directed by Engineer-in-Charge. Make : Hochiki
Supply and fixing in replacement of Photoelectric smoke detector detects the smoke by a couple of infrared diodes. The principle of detection is granule in the smoke can re act infrared light. In order to reduce the interference and lower power consumption, the emitting circuit adopts the pulse signal. The product in accordance with the networking approach is divided into 2-wire and 4-wire detectors complete all as specified and directed by Engineer-in-Charge. Make : System Sensor
Supply, installation, testing and commissioning in replacement of Analog Addressable type Active/ Passive Repeater Fire Alarm panel with Backlit LCD Display, having Controls For Reset, Mute, Accept , Silence alarms and Self Test Conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. Make : Honeywell
Supply, installation, testing and commissioning in replacement of Intelligent Analog Addressable Type Manual Call Point having Surface or flush mounting Option fully complaint to EN54 having Rotary Decade Swicthes for Addressing from 01-99 complete with Back Box for Mounting Complete as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. Make : - Honeywell
Supply, installation, testing and commissioning in replacement of BG-MS-2 manual call point designed to provide a manual alarm interface to any conventional fire alarm control panel. ASES MCPs are made of CRCA sheet as per the IS standards. There is a transparent glass protecting the MCP from the front side. A small MS powder coated hammer is attached with the MCP, This is used to break the front glass to generate alarm in the system. All the MCP comes with a factory fitted back box for Surface or Semifllsh mounting on the wall complete all as specified and directed by Engineer-in-Charge. Make : - System Sensor
Supply, installation, testing and commissioning in replacement of Manual Call Point Bi Directional wireless communication Fully intelligent Utilises standard low cost lithium battery technology Long battery life Fast response , Integral short-circuit isolator Bi-colour status LED, Non-frangible element fitted as standard (conforms to EN54) Surface or flush mounting, LPCB Approved to EN54 complete all as specified and directed by Engineer-in-Charge. Make : - Hochiki/Cease Fire
Supply and fixing in replacement of Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54 / LPCB /VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. make :- Honeywell
Supply and fixing in replacement of sounder with strobes are audio and visual notification device used to alert trained personnel to investigate possible emergency situations and to take appropriate action. Sounder with strobe is rich with features guaranteed to cut installation times and maximize profits. The strobe light consists of High glow LED Which give a strong light that can be visible from a long distance. These sounders are specially used in the noisey areas. These sounders can be used for indoor complete all as specified and directed by Engineer-in-Charge. make :- System Sensor
Supply and fixing in replacement of wireless Addressable Type Loop Powered Hooter Cum Strobe complete with Mounting Base as required conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge. Make :- Hochiki
Supply and fixing in replacement of Intelligent Analog Addressable Type Control/Output Modules having option of RAIL or Surface Mounting with Tri Colour LED status Indicator with Built in Short Circuit Isolators having Visible Rotary Decade Address Swicthes from 01-99, for initiating Hooter/Sounder/Strobes etc dully approved to GEA GE1-082conforming to BS5839 Standards and Duly Approved by EN54/LPCB/VDS/UL/BSA complete all as specified and directed by Engineer-in-Charge Make:- Honey well
Supply and fixing in replacement of Internal Printer Module complete all as specified and directed by Engineer-in-Charge. Make :- Honeywell
Supply and fixing in replacement of Modbus TCP/IP interface module. Requires an RS485 card to be fitted in the control panel & MI-RJ-45 Cable complete all as specified and directed by Engineer-in-Charge. Make:- Honeywell
Supply and fixing in replacement of HFP AP-CRLS Local LCD Control Repeater,Semi-Flush Mounting ,Power Supply 750mA complete all as specified and directed by Engineer-in-Charge. Make:- Hochiki
Supply and fix in replacement of wire to wireless translator module fixing and necessary connections complete all as specified and directed by Engineer-in-Charge. Make:- Hochiki
Supply & fix in replacement of Wireless repeater allowing full EN54 compliance without additional hardware complete all as specified and directed by Engineer-in-Charge. Make:- Cease Fire
Supply, installlation, testing and commissioning in replacemnt of Hooter cum Strob Fits inside the Pro-Sense modular wall sounders and sounder beacons to make them wireless device complete all as specified and directed by Engineer-in-Charge. Make:- Cease Fire
Supply & fix in replacement of 4"x4" MS junction box for detector mounting complete all as specified and directed by Engineer in Charge.
Supply & fix in replacement of battery maintenance free 12 volt 24 AH complete all as specified and directed by Engineer in Charge.
Supply & fix in replacement of battery maintenance free 6 volt 7 AH complete all as specified and directed by Engineer in Charge.
Supply & fix in replacement of Duracell Rechargeable AA 2500mAh Batteries for wire alram panel complete all as specified and directed by Engineer in Charge.
Supply & fix in replacement of cable 2x1.5 sqmm PVC insulated armoured copper conductor and all fixing arrangements on walls complete all as specified and as directed by Engineer-in-charge. Note : The copper conductor cable of size 1.5sqmm shall be ZHLS/FRLS type.
Supply an fix in replacement only of rigid PVC conduit pipe conforming to IS-9537 (Part-III) with all fittings medium duty of size 20mm complete all as specified and directed by Engineer in Charge.
S & F in replacement Loop driver card suitable for fire alarm/detection control panel
Disconnecting the Bus bar chamber from the existing base by disconnecting cable off size complete all as specified and directed.
Supply and Installation in replacement of bus bar chamber 600mm wide and 600mm long 200mm depth and fixing of bus bar copper 4 strip 400 Amps rating on porcelain insulators inside the chamber, Bus bar chamber shall be made out of 2mm thick CRCA MS sheet with angle iron frame made out of angle iron of size 45x45x6mm thick duly painted with one coat of red oxide primer and two coat of synthetic enamel paint inside and out side including fixing of bus bar chamber on PCC platform out door type including welding works grouting on floor with bolts, nuts and washers etc with locking arrangement complete all as specified and directed by Engineer in charge. Make : Havells/MDCS/ Schneider
Design , development, supply commissioning & testing EHCC certified ground tubular effective chemical earthing system (CPRI tested for 15 KA current capacity for LT line) highly anticorrosive long life electrode with and including adequate protective coating to withstand severe wear conditions in the earth pit of the standard size comprising of 25mm x 3mtr long Copper rod as primary conductor and hollow Copper tube of dia 50mm x 3mtr long as secondray conductor to install with suitable connecting terminal coforming of IS 3043 : 1987 specification, continuous copper strips/Brazzing to be used ,highly conductive packing material to be filled in earth pits for providing uniform, low resistivity anticorrosive, hygroscopic medium around the earth system for improving the efficiency of current dissipation 20 kg per bag(3 bag per kit) minimum or sufficient quantities required as per site complete including FRP earthing pit clause suitable cover, brazing,nut bolts etc material and labour complete all as specified and as directed by Engineer-in-Charge. (Make: Ennov model:ELE-350-CU/JMV / Atharva / Pragati telecom (P) Ltd)
S & F Earth continuity conductor of size 20 X 3 mm copper strip fixed on wall/burried in ground with and including fixing arrangements on walls/surface/earth plate like porcelain/hydroscopic insulators, screws, washers etc.,or isolated from wall/surface complete all as specified by Engineer in Charge.
Test point terminal block of size 75 mm X 75mm X 25mm made of copper or phosphorus bronze, drilled and screwed with and including 3 Nos 8 mm dia and 25 mm long hexagonal head screw complete all as specified by Engineer-in-Charge. (Note) :- (i) No payment shall be made if test result not found satisfactory and contractor has to make alternate earthing till the result found satisfactory without any extra cost to the Govt. (ii) Contractor shall give the guarantee for 01 years for earth resisitance & earth neutral Voltage below 0.5 Ohms and earth neutal voltage less than 01 volts. ( iii) Protection pipe of GI pipe light grade of size 40mm provided crossing path/culvert or open area at no extra cost. (Iv) The rate quoted shall deemed to include the cost of earth strip and protection pipe up to 7.5 mtr beyond the earth plate electrode.
Supply and fix in replacement of MCCB 160 A, 25 KA breaking capacity , four pole, 415 volts.
S&F in replacement of single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20-32 amps, 240 volts, 10KA complete all as specified and as directed by Engr -in - Charge.
M/L for Sub main wiring with under mantioned runs of S/C PVC insulated but unsheathed FRLS cable of specified size with multistranded copper conductors 1100 volt grade IS- 694 marked drawn through and including non metalic PVC conduit pipe medium grade ISI marked (not less than 20 mm dia) along with fittings and accessories all fixed concealed on surface of wall / ceiling or surface conduit wiring on wall/ceiling and also including the specified runs of specified size earth continuity conductor of similar type of cable complete all as specified and directed. (The under mentioned specified runs of single core cables and specified runs of earth continuity conductors and the releavent conduit with accessories shall be measured as one length) (a) 2 Run of 10.0 Sqmm cable and 1 run of 6.0 sqmm cable connectd to common earth dolly.
(b) 2 Run of 6.0 Sqmm cable and 1 run of 4.0 sqmm cable connectd to common earth dolly.
(c) 2 Run of 2.5 Sqmm cable and 1 run of 1.5 sqmm cable connectd to common earth dolly.
Khairati Lal
J.P. Enterprises
Continental Engineers and contractors
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .