Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹5.9 LAccepted-AOC | L-1 | Accepted-AOC ACCEPTED BY THE CA SINCE THE BIDDER IS L-1 | |
| 2 | L-2₹6.6 L+₹74,481 (12.7%)Rejected-Finance NO 1 57 CLIFFTHI COTTAGE NEAR KALLODI BAJPE MANGALURU 574 142 | DAKSHINA KANNADA | KARNATAKA | 574142 | L-2 | Rejected-Finance NOT THE L-1 HENCE NOT ACCPETED BY THE CA | |
| 3 | L-3₹6.7 L+₹79,693 (13.5%)Rejected-Finance SEETHA NILAYA MADYA SURATHKAL | DAKSHINA KANNADA | KARNATAKA | 574107 | L-3 | Rejected-Finance NOT THE L-1 HENCE NOT ACCPETED BY THE CA |
Tender Value
₹6.6 L
Closing Date
20 May 2024, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
REGISTRAR, NITK
NITK,SRINIVASNAGAR POST SURATHKAL
Providing RCC platform and Aluminium partition at 5th floor Rm No 507 and 6th floor Rm No 607 in Civil Engineering Department annex building in NITK
2024_NITK_807152_1
Tender No.02/2024-25/HD
Open Tender
Civil Works
Works
45 days
NITK, SURATHKAL
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹0
Exempted
8 Jul 2024
14 May 2024
21 May 2024
14 May 2024
20 May 2024
14 May 2024
Amount
Dismantling Mosaic / ceramic tile: Dismantling Mosaic / ceramic tile work of any thickness in floors and roofs laid in cement mortar including, stacking material to the appropriate disposal of the debris with all lead (within the campus as directed) and lift etc., complete– in all the floor levels.
Dismantling Stone masonry: Dismantling dressed stone work ashlar face stone work, marble work or precast concrete work manually/ by mechanical means including stacking of serviceable and disposal of unserviceable material to the appropriate disposal area as per direction of Engineer-in-charge. – in all the floor levels
Dismantling plastering: Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground to the appropriate disposal area as per direction of Engineer-in-charge. – in all the floor levels
C.C.Solid block masonry: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. – in Fifth floor.
C.C.Solid block masonry: Providing and constructing load bearing wall with Solid Concrete blocks of size 400x100x200mm having block density more than 1800kg/m3 and minimum compressive strength of 4.00 N/mm2 conforming to IS 2185 (Part - I) - 2005 and constructed with CM 1:4 as per IS 2572:2005 including cost of all materials, labour, scaffolding and curing, usage charges of machinery etc complete as per specifications. – in Sixth floor.
Cudapa slabs : Providing 20mm thick cudapa slab using cement mortar 1:6 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications., Specification No. KBS – In 5th Floor
Cudapa slabs : Providing 20mm thick cudapa slab using cement mortar 1:6 25mm thick over existing cement concrete bed or top of roof laid to line and level and jointed with cement slurry mixed with pigment to match the shade of the slab, including cost of materials, labour, curing, polishing complete as per specifications., Specification No. KBS – In 6th Floor
TMT steel reinforcement: Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)- in 5th Floor
TMT steel reinforcement: Providing Thermo-Mechanically Treated bars of grade Fe-550D or more Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position, binding and anchoring to adjacent members whereever necessary complete as per Design including cost of material, labour, usage charges complete as per specifications. (The laps and wastages shall not be measured separately)- in 6th Floor
M20 for RCC Platform: Providing and laying in position reinforced cement concrete of design mix - M20 - with OPC cement at 320 kgs/ PPC/ PSC cement with 20mm and down size graded granite metal coarse aggregates at 0.69 cum and clean sieved fine aggregates at 0.46 cum with superplasticizer at 3ltrs conforming to IS 9103 -1999 Reaffirmed-2008,machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for RCC works of all sizes including cost of all materials, labour HOM of machinery curing complete as per specifications (excluding cost of steel and fabrication charges). Design mix test should conform to IS 456:2000 - Specification No. KBS 4.1, 4.6- In 5th Floor
M20 for RCC Platform: Providing and laying in position reinforced cement concrete of design mix - M20 - with OPC cement at 320 kgs/ PPC/ PSC cement with 20mm and down size graded granite metal coarse aggregates at 0.69 cum and clean sieved fine aggregates at 0.46 cum with superplasticizer at 3ltrs conforming to IS 9103 -1999 Reaffirmed-2008,machine mixed, concrete laid in layers not exceeding 15 cms thick, vibrated for RCC works of all sizes including cost of all materials, labour HOM of machinery curing complete as per specifications (excluding cost of steel and fabrication charges). Design mix test should conform to IS 456:2000 - Specification No. KBS 4.1, 4.6- In 5th Floor
15mm thick cement plastering: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- in 5th Floor
15mm thick cement plastering: Providing 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 cement: 4 fine sand) including rounding off corners wherever required smooth rendering, providing and removing scaffolding, including cost of materials, labour, curing complete as per specifications and as per directions of Engineer-in-charge.- in 6th Floor
Polished Granite stone flooring: Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.- In 5th floor
Polished Granite stone flooring: Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. ** Polished Granite stone slab Black, Cherry Red, Brown, Cat Eye, River Pink or equivalent.- In 6th floor
Nosing for Granite slab: Providing half nosing for 18mm thick granite slab using required machinery including cost and conveyance of all materials, labour for all items of work, HOM of equipment, necessary scaffolding etc., complete as per specification.
Vitrified tiles: Providing and laying Vitrified tiles in 600mmx600mm sizes (thickness to be specified by the manufacturer – 9-10mm), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of spacer joints as per direction of Engineer in charge.-( In 5th Floor )
Vitrified tiles: Providing and laying Vitrified tiles in 600mmx600mm sizes (thickness to be specified by the manufacturer – 9-10mm), with water absorption less than 0.08% and conforming to IS: 15622, of approved brand & manufacturer, in all colours and shade, in skirting, riser, treads of steps, with cement based high polymer modified quick set tile adhesive (water based) conforming to IS: 15477, in average 6 mm thickness, including grouting of spacer joints as per direction of Engineer in charge.-( In 6th Floor )
Primer Coat: Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound) content. With water thinnable cement primer on wall surface having VOC content less than 50 g/L as per specifications and as per directions of Engineer in charge.
Plastic emulsion paint in two coats on new work: Wall /ceiling painting with plastic emulsion paint of approved brand and manufacture to give an even shade Asian Emulsion/ Nerolac / Berger/ Sherwin Williams/ equivalent) :Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge.- in all the floors
PVC Door frame: Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.- in 5th Floor
PVC Door frame: Providing & fixing factory made PVC Door frame of size 50x47mm with a wall thickness of 5mm, made out of extruded 5mm rigid PVC foam sheet metered cut at corners & jointed 2 No.s of 150mm long brackets of 15x15mm M.S Square tube, the entire door frame to be reinforced with 19x19mm M.S Square tube of 19 gauge. The door frame to be fixed to the wall using M.S. Screws of 65/80mm size complete as per manufacturers specification & direction of Engineer-in-charge.- in 6th Floor
Factory made Rigid foam both side prelam panelled door shutter: Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer- in-charge fixed to frames with 3 nos of 75mm Stainless steel hinges.- with both side prelam shutters – in 5th floor.
Factory made Rigid foam both side prelam panelled door shutter: Providing & fixing 30mm thick factory made rigid foam Prelam Panelled Door Shutters made from M.S. tube of 19x19mm, 19 gauge for stiles and 15x15mm for top & bottom rails, covered with heat moulded Prelaminated PVC C Channel of 5mm thick sheet & 30x50mm wide to form stiles & 5mm thick & 75mm wide Prelaminated PVC Sheets for top rail, lock rail & bottom rail on either side & 5mm thick, 20mm wide cross PVC sheet as gap insert for top rail & bottom rail, Panelling of 5mm thick PVC sheet Prelaminated on either side fitted in the M.S. frame, Sealed to the stiles & rails with PVC Designer beading on either side & joined together with solvent cement adhesive etc., Complete as per manufacturers specification & direction of Engineer- in-charge fixed to frames with 3 nos of 75mm Stainless steel hinges.- with both side prelam shutters – in 6th floor.
Wooden door frame: Providing Mathi/Nandi wood frames of doors, windows, clerestory windows, ventilators and other frames, wrought, framed or assembled including making plaster groves, including cost of materials, labour, usage charges complete as per specifications.- in 6th Floor
Flush Door Shutter: Providing and fixing flush door shutter made out of solid core block board type, well seasoned , chemicaly treated hard wood battens and internal frame with minimum 45 mm wide wooden frame lround door shutters covered with cross bonded wooden sheets (core veneer) hot pressed and fastened on both sides of the door useing liquid phenol formaldehyde resin as per IS specifications 2202 (part-I) 1991. from manufacturer complete as per specification - 35 mm thick both side commercial.- In 6th Floor
Synthetic enamel paint in two coats on new surface: Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: Two coats on new work after thoroughly brooming the surface to remove all dirt, dust, mortar drops and foreign matter including preparing the surface even and sand paper smooth, cost of materials, labour complete as per specifications and as per directions of Engineer-in-charge. Asian /Nerolac/ Berger or equivalent Make – in 6th Floor
Anodized Aluminium Partitions: Providing and fixing aluminium work for partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately): For Fixed Portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.-5th floor
Anodized Aluminium Partitions: Providing and fixing aluminium work for partitions with extruded built up standard tubular sections/appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately): For Fixed Portion: Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.-5th floor
Aluminium work for Doors: Providing and fixing aluminium work for doors, with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) :For shutters of Sliding doors, including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.- in 5th floor
Aluminium work for Doors: Providing and fixing aluminium work for doors, with extruded built up standard tubular sections/ appropriate sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling to be paid for separately) :For shutters of Sliding doors, including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Anodised aluminium (anodised transparent or dyed to required shade according to IS: 1868, Minimum anodic coating of grade AC 15) including cost of materials, labour, usage charges of machinery complete as per specifications.- in 6th floor
5mm thick glass for Aluminium windows and Aluminium doors: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.- 5th Floor
5mm thick glass for Aluminium windows and Aluminium doors: Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5 mm thickness (weight not less than 12.50 kg/m²) including cost of materials, labour, usage charges of machinery complete as per specifications.- 6th Floor
Prelaminated particle board: Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. – In 5th floor
Prelaminated particle board: Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminium doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in- charge: Pre-laminated particle board with decorative lamination on both sides including cost of materials, labour, usage charges of machinery complete as per specifications and as per directions of the Engineer-in-Charge. – In 6th floor
100mm mortice latch and lock with 6 levers: Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete including cost of materials, labour, usage charges of machinery complete as per specifications.
Hydraulic door closer: Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS: 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete
Aluminium Tower Bolt: Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete.
Steel Sink: Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets, cutting and making good the walls wherever required :- 610x510 mm bowl depth 200 mm
Lab Sink: Providing and fixing white vitreous china laboratory sink with C.I. brackets, C.P. brass chain with rubber plug, 40 mm C.P brass waste and 40mm C.P. brass trap with necessary C.P. brass unions complete, including painting of fittings and brackets, cutting and making good the wall wherever required : - Size 600x450x200 mm
3 Way CP Lab Tap: Providing and fixing 3 Way chromium finish laboratory tap by fixing to working platform by making suitable holes on platform including cost of fitting, labour, material charges etc. complete as per the direction of engineer In-charge.
Wall bore: Wall bores in size stone masonry including cost of materials, labour, HOM complete as per specification. – in all the floor levels.
CPVC plumbing pipes – 20 mm dia: Providing and fixing Chlorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (external works and good the walls etc)- 20mm nominal dia pipes – In 5th floor
CPVC plumbing pipes – 32 mm dia: Providing and fixing Chlorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (external works and good the walls etc)- 32mm nominal dia pipes – In 6th floor
CPVC plumbing pipes – 20 mm dia: Providing and fixing Chlorinated poly vinyl Chloride (CPVC) pipes conforming to IS 15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamp at 1.00 mtr spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete. (external works and good the walls etc)- 20mm nominal dia pipes – In 6th floor
SS Angle cock – 15mm size: Providing and fixing SS angle cock for basin mixer and geyser points of approved quality conforming to IS:8931 – in all the floor levels
UPVC connection pipes 15mm dia: Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. - 15 mm nominal bore with 30cm length – in all the floor levels
DSOUZA ELECTRICALS
SUDHIR ELECTRICALS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .