REPAIR AND MAINT OF LT CABLE , EXTERNAL ELECTRIC POWER TRANSMISSION SYSTEM ,SECURITY LIGHT CONTROL PANEL, CABLE, HIGH MAST DISTRIBUTION SYSTEM FOR SECURITY LIGHT, GARDEN LIGHT AND OTHER MAINT AND ALLIED WORKS AT SITE P AFS UNDER GE AF THANE
2023_MES_633691_1
8305/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
THANE
AS PER NIT
8 documents required · 8 mandatory
₹500
GE AF THANE
₹59,400
Yes
13 Apr 2024
20 Dec 2023
13 Feb 2024
20 Dec 2023
6 Feb 2024
24 Jan 2024
20 Dec 2023 - 24 Jan 2024
Amount
Taking out old unsv LT UG cable of 3.5 core x 70 Sqmm to 150 Sqmm size and shall be deposited to place where as directed
Taking out old unservicable LT UG cable of 4/3.5 core x 10 Sqmm to 25 Sqmm size and shall be deposited to place where as directed by Engr In Charge
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 25 sq mm 4 core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 95 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 150 sq mm 3½core.Make: Polycab/Havells/Paragon
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 70 sq mm 3½core.Make: Polycab/Havells/Paragon
Excavation in trenches, n exc 1.5 mtr wide and n,exc 1.5 mtr in depth; for foundation etc. or for shafts, wells cesspit, manholes, pier holes,etc n,exc 10 Sqm on plan and n exc 1.5mtr in depth and getting out as in Soft/loose Soil,complete all as specified and directed by Engg-in-Charge.
Returning, Filling in including Spreading, Levelling, Watering, Well Ramming in Layers not exc. 25 Cm, in Soft/Loose Soil, ,complete all as specified and directed by Engg-in-Charge.
Removing excavated material n exc. 50m in soil and depositing where directed at a level n exc. 1.5 m above the starting point , including loading, unloading and stacking at the destination , complete all as specified and directed by Engr-in-charge.
M&L for Sand cushioning for UG cable protection/ducts, consolidated sand compacted with clean dry sand , complete all as specified and directed by Engr-in-charge.
M & L for Boring of road crossing in any kind of soil/rock strata , complete all as specified and directed by Engr-in-charge.
Supply and laying in trenchs with sub- class ‘B’ bricks straight or curved on plan exc 6 m mean radius complete all as specified and as directed.
Supply & laying GI pipe light graded of size 50mm dia in trenches and fixing on wall / pole with help of suitable size MS clamp for cable protection with all fitting; complete all as specified and directed by Engr-in-charge.
S&F GI pipe light grade of size 80mm dia fixing on pole/laid in trenches
S&F GI pipe light grade of size 40mm dia fixing on pole/laid in trenches
S&F GI pipe light grade of size 15 mm dia fixing on pole/laid in trenches
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 4 core x 10/16/25 Sqmm size , complete all as specified and directed by Engg-in-Charge. Make : Denson Part No : XSS-02/Raychem / M-Seal/ Birla-3M
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 3.5 core x 95/70 Sqmm , complete all as specified and directed by Engg-in-Charge. Make : Denson Part No : XSS-02/Raychem / M-Seal/ Birla-3M
Supply, perform, testing, commissioning of LT cable End through joint kit heat shrinkable of 3.5 core x 150 Sqmm size complete all as specified. Make : Denson Part No : XSS-02 /Raychem / M-Seal/ Birla-3M
Supply only MCCB 4 pole 63 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian /Havells/HPL
Supply only MCCB 4 pole 100 A , 415 V, 50Hz having breaking capacity 16 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian/Havells/HPL
S&F Danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as spd and directed.
Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections including nuts, bolts,ashers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as indicated or directed and inclusive of one primer coat, one under coat and one finishing coat of paint
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
Supply only MCCB 4 pole 160 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting complete all as spd and directed by Engr-in-Charge.Make: Indoasian Cat No.X220M4T/Havells/HPL
Supply only MCCB 4 pole 200 A , 415 V, 50Hz having breaking capacity 36 KA with adjustable thermal & magnetic setting , complete all as specified and directed by Engr-in-Charge.Make: Indoasian Cat No.X250H4T/Havells/HPL
Supply only MCCB 4 pole 250 A , 415 V, 50Hz having breaking capacity 35 KA with adjustable thermal & magnetic setting , complete all as specified and directed by Engr-in-Charge .Make: Indoasian Cat No.N3200M4P/Havells/HPL
Inspection/checking & testing after repair of APFC panel 3 Phase,440 voltage 50Hz AC supply system to improve power factor 0.80 to 0.99 automatic step wise switched capacitor panel to make it serviceable in auto and maunal mode, with the help of connecting relays, capacitors,contactors,MCB's.,CTs, re-wiring burnt/worn out control wires etc and rectifying the defects, replacement of unserviceable parts as required at site and cleaning of AMF panel as detecting during inspection or pointed out by department and carry out maintenance complete all as specified as directed by Engineer-in-Chrage. (Notes :-This items includes the cost of cleaning & rewiring of panel. Spare parts required shall be measured and paid for separately under respective items as supply only)
Supply only in replacement of AIPFC microprocessor based relay 8 stage PFC controller ,230 volts complete all as specified and directed by Engineer-in-Charge. Make- L&T/EPCOS/Siemens
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 10 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of Heavy duty capacitor 3 Phase,415 Volt, AC, 50 Hz of capacity 15 KVAR complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 20 KVAR capacity 240 volts complete all as specified and as directed by Engineer-in-Charge.Make- Epcos, L&T
Supply only in replacement of capacitor duty contactor 3 phase suitable upto 16 KVAR capacity duty contactor 1NO1NC 240 volts complete all as specified and as directed by Engineer-in-Charge.Make- Epcos, L&T
Supply & fixing in repair of MCB 6 to 32 Amps, 3 Pole,10 KA coplete all as specified and directed by Enginner-in-Charge.
Supply only in replacement of current transformer of ratio 200/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply only in replacement of current transformer of ratio 100/5, 10 VA with accuracy of 1.0 including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement indictor lamp assembly LED type complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing Start/stop push button complete including connection with 2.5 Sqmm twin core PVC cable complete all as specified and as directed by Engineer-in-Charge.
Supply & fixing in replacement of digital type multimeter 96 mm x96 mm, of range 0-500 Volts and 0-200 Amps ,Class-I complete all as specified and as directed by Engineer-in-Charge.
M&L for fixing MS sheet 2mm thick to existing LT panels / feeder pillar box including necessary straightening /correcting the distorted parts, cuttings, welding / riveting,drilling bend to shape as required, welding of hinges, sliding door bolts, locking arrangement, nut, bolts, washers etc and appying two coats of synthetic enamedled paint over a coat of red oxide primer to match with the existing surfaces comlepte including butt hinges sliding door bolts and taping , thimbling disconnecting all incoming and outgoing complete all as specified and as directed by Engineer-in-charge. Note :- Supply only butt hinges and sliding door bolts shall be measured and paid seperately.
Material and labour for carrying out repair/maintenance through manufacturer or authorised service center of Auto servo control voltage stabilizer 300KVA capacity located at HQ area . (i)Opening of stabilizer and maintanance of spare parts,fixing of new/repaired parts after repair in place of defective parts,repairing the defective control system etc and assembling complet all as specified and directed. Testing of stabilizer after repair on existing location to desired and rated output. Note:- All defective parts maint and cost of labour for maint is deem too be included in unit rate .
Disconnecting all incoming and outgoing connection of HT 22KV under ground cable,detecting fault by applying surge current 1.5 times the rated current & finding exact location of fault with PICO equipment and repair the same immediately etc complete all as specified and directed by Engineer.in.Charge.Note: Necessary Jointing kit to be measured and paid separately in respective items.
Taking down Defective street light of LED of Capacity 25/30/60/90 W, flood light and bldg security light fitting of any type from their existing postion ie. Poles and bldg and re-fixing the same after carried out repairs ie. replecement of LED driver and SPD,PVC Wire etc all as specified and directed by Engr In Chrarge. Note: LED Driver,SPD and 3 core cable for replacement shall be measured and paid separatly under relevent item of Sch 'A' as supply only.
Supply only Surge protection device (SPD) of capacity as mentioned below, with phase ,neutral and earth wire in incoming and out going both sides, complete all as specified and directed by Engg.in.Charge. Make: Bajaj/Havells/Crompton.Of the following Capacity:-
Of capacity 8 KV
Of capacity 5 KV
Supply only LED driver for LED Street light Fitiing ,of the following,complete all as specified and directed by Engg-in-Charge.Make: Bajaj/Havells/Crompton
for 25 Watt
for 30 Watt
for 60 Watt
for 90 Watt
Supply, fixing and testing LED street light fitting including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) ,complete all as specified and directed by Engg-in-Charge .Make: Bajaj /Havells/Wipro. Of the following:-
For 45 Watt
For 60 Watt
Supply, fixing and testing LED Flood light fitting in repair/replacement of existing high mast lights including LED lamps complete with body robust,corrosion resistant,superior finish and without any cracks or through holes,made in a single piece by high pressure die cast aluminium alloy.The luminaries shall be monolithic construction totally enclosed dust and water proof with minimum IP -66 protection as per IS - 10322-1982(Part -I) ,complete all as specified and directed by Engg-in-Charge .Make: Bajaj /Havells/Wipro. Of the following:-
Of 120 Watt
Of 80 Watt
M & L for connecting 1100 volt grade heavy duty cable PVC insulated copper conductor, served with inner sheathing of PVC tap and over all PVC sheathed in service connection for street light from FRP junction box to street light of size 3 core 1.5 Sqmm ,complete all as specified and directed by Engg-in-Charge. Make: Paragon/HPL/Havells
Cutting/Trimming of tree branched not exc 10 cm girth touching /approaching the LT/HT Over head line (having each span of 45 mtr) upto 3 mtr width on each side with cutting machine or manually to clear the LT/HT line including disposal of trimmed branches 100 mtrs away inside the cantonment area & cleaning site ,complete all as specified and directed by Engg-in-Charge. ( Note : All tools and plant required for cutting shall included in quoted rates)
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat , complete all as specified and directed by Engg-in-Charge.of the following sizes:-
For flat of size 6 Sqmm
For flat of size 10 Sqmm
Supply, perform, testing, commissioning of LT cable straight through joint kit heat shrinkable of 4 core x 10/16/25 Sqmm size , complete all as specified and directed by Engg-in-Charge. Make : Denson Part No : XSS-02/Raychem / M-Seal/ Birla-3M
Supply and fixing HOT moulded (FRP) junction box for street light pole with locking arrangement with IP 65 protection of size 280 x 200 with 32 Amp 4 way heavy duty terminal block with 10Amp MCB SP and two number of cable entry gland of standard size with suitable stainless steel bracket to fix with pole, including taking down existing , complete all as specified and directed by Engg-in-Charge.
Supply & Fixing LED Bollard light 9/10 watts with opal acrylic diffuser and IP-65 protection , pressure die cast housing with PC diffuser, suitable for garden and pathway complete with internal connection including suitable size of stand for LED garden light of 9/10 Watts capacity , complete all as specified and directed by Engg-in-Charge. Make: Bajaj cat part No. BGBOM 650 9W LED/Halonix Cat Part No.HLOB-03-10 CW/Crompton Cat part No.LBLA2-10-CDL Note : Warranty and test certificate of LED light fittings to be produced as and when asked by Engr-in-charge.
Supply and fixing MCB DB single door vertical type for 2 way 240 volt SPN confirming to IP-45 protection and IS 13032 , complete all as specified and directed by Engg-in-Charge.
M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate, in lintels upto 1.5 m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs not provided for in Item 04028, water troughs and the like including weathering, slightly rounded for chamfered angles and throating, complete all as specified and directed by Engr-in-charge.
M&L for Plain Cement concrete in foundations, filling and mass concrete , type D-2 (1:4:8) using 40mm graded stone aggregate as in foundations, filling & mass concrete, complete all as specified and directed by Engr-in-Charge.
Supply only aluminum lugs suitable for Cable of the following sizes:- Make : Denson/Raychem / M-Seal/ Birla-3M
Of size 10 Sqmm to 16 Sqmm
Of size 25 Sqmm.
Of size 35 Sqmm
Taking down complete defective high mast light system by using suitable size of Crane reach up to 20 mtr height and removing complete defective rope of 6 mm dia 97/19 gauge with 3 phase power motor, electrical cable 6 sqmm 3 ph and gear box. Supply and fix the same with new one and checking and servicing complete high Mast system like electrical wiring , greasing in all moveable parts as specified by Engr in Charge.
Taking down carefully existing aluminium/Copper point wiring light, fan socket or power bell complete with fitting such as sockets, ceiling roses, pendants batten holders regulators socket, call bells & making good to the disturbed surfaces of walls, matching the colour with existing Surface all as spd and directed by Engr-in-Charge. Note: Rate for making good shall be deemed to be included in quoted rate.
Taking down unserviceable main switches and MCB distribution boards single phase ,complete all as specified and as directed by Engr-in-charge
M& L for Point wiring complete with 1100 volts grade FRLS insulated unsheathed cable of copper conductor cable multi stranded of size 1.5 Sqmm single core including PVC rigid concealed conduit medium grade of suitable size (not less than 20mm dia) with all accessories such as bend reducers /MS hooks, MS junction box 1.2mm thick MS pressed sunken terminal boxes of suitable sizes for mounting of switches sockets, fan regulators etc covered with 3.15 mm thick bakelite laminated (Hylem/Anchor) top cover including continuous earth wire of size 1.5 Sqmm PVC strandedcopper conductor unsheathed, insulated stranded (Green colour) connected to common earth point dolly ,complete all as specified and as directed by Engr-in-charge .for the following:-
One light point/call bell point/fan point to be controlled by one number one way PT switch
Switch socket combination 5 Pin 5 Amps 230 Volts point controlled by one switch and wiring with 1.5 Sqmm PVC unsheathed copper conductor cable 1.5 Sqmm PVC insulated earth wire on independent board
All as per item No 64.02 above but on same board
Switch socket combination (multi purposes) 6 Pin 15 Amps point to be controlled by one switch & wiring with 2.5 Sqmm PVC- unsheathed copper conductor cable 2.5 Sqmm PVC insulated earth wire on independent board.
M & L for point wiring with FRLS PVC insulated 1100 Volts grade IS-694 single core multistranded Copper conductor cable 1.5 Sqmm drawn in and including PVC casing capping with accessories, fixed on wall/ ceiling etc with necessary fixing accessories and earth continuity copper conductor cable of size 1.5 Sqmm green colour Connected to common earth dolly including pressed mild steel terminal boxes 16 gauge thick of adequate size concealed in wall Covered with 3.15 mm thick bakelite laminated (Hylem/Anchor) for mounting switches/ sockets/ fan regulators / bell push buttons etc fixed with cadmium plated machine steel screws and washers all as specified for the following :-
One Light point/fan point/Bell point controlled by one switch .
One 3 pin 5 Amps socket out let on independent board
One 3 pin 5 Amps socket out let on same board
Ditto-All as per Srl item No 65.00 above but for 2.5 Sqmm wire for 15 Amp socket outlet on independent board
One light point controlled by two 2-way switches
S&F switch Piano type single pole one way 5 Amp,230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F switch Piano type single pole two way 5 Amp,230 VAC ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
Supply and fixing bell push flush type 5 Amp ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F in repair switch socket combination multipin 5 Amps 230 VAC ,complete all as specified and as directed by Engr-in-charge Anchor/Havells/Legrand
S&F switch Socket combination Piano type multipin 15/16 Amp on laminated sheet top cover ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F bell ding dong AC 230V single pole ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F Ceiling rose, two to three terminals with bakalite 20mm back plate,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
Supply & fixing PVC Lamp holder suitable for and including batten fittings ,CFL/Electric lamp with backalite 20mm back plate ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S&F Batten for LED tube light fixture with extruded aluminium heat sink,environmental friendly energy efficient ready to use with 18/20W LED 6000K(4') including electric connection with PVC copper flexible three core cable 24/.0076 from ceiling rose to light fitting ,complete all as specified and as directed by Engr-in-charge .Make: Havells/Bajaj/Crompton
S&F fan regulator electronic socket type 5 speed for ceiling fan 1200/1400 mm sweep ,complete all as specified and as directed by Engr-in-charge.
S & F ,in repair, fan regulator Electronics step type 80 watts and connecting,complete all as specified and as directed by Engr-in-chargeMake: Anchor/Havells/Legrand .Make: Anchor/Havells/Legrand
S & F ,in repair, Bell push button flush type 5 Amp,240v ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, and fix bell multi musicAC 230 volt single pole ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Switch piano, flush type, single pole, one way, 5 Amp,240V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, ceiling roses, surface bakelite 65x50mm ,3 terminals 3 phase, PVC/Polycarbonate, isolated body all as specified and directed at site,complete all as specified and as directed by Engr-in-charge. Make: Anchor/Havells/Legrand
S & F ,in repair, switch flame proof rotary type with termination box in LM-6,16A ,single pole 250Volt ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, LED lamp 12 watt, 220 volt ,complete all as specified and as directed by Engr-in-charge .Make:-Philips,Bajaj,CG
S & F ,in repair, modular switch 1 way 16A, 1 module ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, modular switch 1 way 6A, 1 module ,complete all as specified and as directed by Engr-in-charge .Make: Legrand, Schneider, SiemensMake: Anchor/Havells/Legrand
S & F ,in repair, Modular socket 6A/16A-2/3 pin combined 2 modulas flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Modular switch socket combination 16A,6 pin.3 module flush type 220 V ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Modular fan regulator Electronics step type 80 watts 2 moduls and connecting ,complete all as specified and as directed by Engr-in-charge .Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular white cover plate with frame suitable for 6 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 4 module ,complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
S & F ,in repair, Modular Metal flush box suitable for 6 module, complete all as specified and as directed by Engr-in-charge.Make: Anchor/Havells/Legrand
Taking down the ceilling fan with and including cleaning the dust,drit ,greasing,serviceing ,repairing and refixing the original position all as directed. Note:- Necessary spare for repairing will be measured and paid in respective items.
Taking down unserviceable wall mounted fan,exhaust fan of any capacity or size,including cleaning the dust,drit ,greasing,serviceing ,repairing and refixing the original position all as directed. Note:- Necessary spare for repairing will be measured and paid in respective items.
Re winding ceilling fan with super enamelled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep1200 mm ,220 volt ,50 HZ,single phase, complete all as specified and as directed by Engr-in-charge
Re winding exhaust fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep300 mm ,220 volt ,50 HZ,single phase,all as directed
Taking down old unsv industrial type exhaust fan from its position with rusted frame and flap and repair with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire with frame and flap and testing for good running condition of sweep 450 mm ,220 volt ,50 HZ,single phase,all as directed
Re winding wall mounted fan with super enameled copper wire suitable gauge to get designed condition of speed for the particular make of fan including insulating, varnishing, providing sleeves to copper wire and testing for good running condition of sweep 400/450 mm ,220 volt ,50 HZ,single phase, all as directed
S&F ceilling fan of size 1200 mm sweep 5 star rating complete all as specified and as directed by Engr-in-charge.Make-Usha/Bajaj/Khaitan
S&F fresh air fan Steel body of any size not more than 300 mm sweep ,complete all as specified and as directed by Engr-in-charge.Make-Bajaj/crompton
Supply only Gun metal bush suitable for particular make of fan of 1200mm sweep ,complete all as specified and as directed by Engr-in-charge
Supply only Gun metal bush suitable for particular make of exhaust fan of 400/450 mm sweep ,complete all as specified by Engr-in-charge
Supply only ball bearing suitable for particular make of fan of 1200 mm sweep ,complete all as specified Make for Bearing Make:- NBC/Tata
Supply only ball bearing suitable for particular make of exhaust fan of sweep 300mm/450 mm ,complete all as specified.Make :-SKF/NBC/SKF
Supply only condenser 2.5 Mfd/3.5 Mfd capacity ,complete all as specified and as directed by Engr-in-charge. Make :HPL, Asian.
Supply only Capacitor 4Mfd suitable for exhaust fan of sweep 300mm/450mm ,complete all as specified and as directed by Engr-in-charge.
GEYSERS:- Disconnecting and removing from position for repair of geyser of any capacity , replacement of glass wool, element, water tank, flange assembly etc, cleaning internally and externally including checking for leakage in tank and rectification by gas welding, replacement of gasket, nuts, bolts and clamps, reassembling and refixing in position complete to the entire satisfaction of Engr -in-Charge. Note :- (i) Cost of gas welding, nuts, bolts and clamps etc shall be deemed to be inclusive in unit rate quoted by the tenderer. (ii) Replacement of unserviceable parts shall be measured and paid for separately under respective item.
Supply and fix in replacement heating element 3.0 KW (for solar water) complete all as specified and directed. Make:- Theta/Dasspass/Airex.
Supply and fix in replacement heating element 2.0 KW complete all as specified and directed. Make : Theta/Dasspass/Airex.
Supply and fix in replacement Heating element 1.5 / 1.00 KW complete all as specified and directed.(round/triangular) Make:- Theta/Dasspass/Airex.
S&F in replacement PVC insulated & PVC sheathed multi stranded copper conductor cable flexible 3 core, 2.5Sqmm complete all as specified. Make:- Polycab/Finolex/Anchor.
S&F in replacement thermostat ranging 60 degree to 90 degree adjustable type, operative on 250 Volts complete all as specified and as directed. Make:- Dasspass/Indfoss.
S&F in replacement indicator lamp, round/square, green/red as per requirement complete all as specified and directed.
Supply and fix in replacement of inner tank made out of stainless steel of standarad gauge for 25 to 35 litres capacity geysers, ISI marked complete all as specified and directed.
Supply and fix in replacement of inner tank made out of stainless steel for 50 litres capacity geysers, ISI marked complete all as specified and directed.
S&F in replacement geyser syphon assembly chromium plated suitable for 50 litres capacity geysers ISI marked complete all as specified and directed.
S&F in replacement geyser syphon assembly chromium plated suitable for 25 litres capacity geysers ISI marked complete all as specified and directed.
Supply and fix in replacement PVC connection heavy duty connecting with two nos of adopter and washer of size 450 to 600 mm long suitable for geyser and including all fixing accessories complete. Make:- Prayag/Seiko.
Supply and fix in replacement of sheet metal enclosures with two pin and earth plug and socket complete with single pole MCB 20 Amps complete all as specified and directed. Make:- Anchor/Havells/Indo Asian.
Taking down sub main wiring of any size complete and making good disturbed surface of walls/floors etc ,complete all as specified and as directed by Engr-in-charge.
M & L for submain wiring with two runs of single core PVC insulated unsheathed FRLS copper conductor as mentioned below of similar type cable multistranded copper conductor 1100 volts grade IS:694 marked drawn in and including 25mm dia PVC non metallic PVC conduit , medium grade, ISI marked complete with all acessories and fittings laid/fixed concealed in wall/ceiling or surface conduit on wall/ceiling, and connecting to common earth dolly ,complete all as specified and as directed by Engineer-in-Charge. (Note : Cutting chases for counduit and sinking for boxes and making good to walls ,floors etc for sub main wiring will be measured & paid separately in respective items). of the following:-
Cable of size 2X4 sq mm and 1X4 sq mm earth continuity conductor
Cable of size 2X6 sq mm and 1X6 sq mm earth continuity conductor
Cable of size 2X10 sq mm and 1X6 sq mm earth continuity conductor
M & L for submain wiring with two runs of single core PVC insulated unsheathed FRLS copper conductor as mentioned below of similar type cable multistranded copper conductor 1100 volts grade IS:694 marked drawn in CASING CAPPING , medium grade, ISI marked complete with all acessories and fittings laid/fixed concealed in wall/ceiling or surface capping on wall/ceiling, and connecting to common earth dolly ,complete all as specified and as directed by Engineer-in-Charge. of the following:-
Cable of size 2X4 sq mm and 1X4 sq mm earth continuity conductor
Cable of size 2X6 sq mm and 1X6 sq mm earth continuity conductor
M & L for HDPE chamber for earth pit including necessory PCC 1:3:6 type B-2 for fixing the PVC inspection chember of size 200 mm depth, 300mm length and 300mm width ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair, aluminium strip of 25x3mm as roof conductor and down conductor till test point all as directed by.Note-Aluminium strip to be jointed through nut,bolt and washers only ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair,copper strip of 20x3.15 mm as roof conductor and down conductor till test point all as directed by.Note-Copper strip to be jointed through brazzing only ,complete all as specified and as directed by Engineer-in-Charge.
S&F,in repair, Porcelain insulators of Copper/Aluminium strip on wall / on Roof building with necessary screws washers and nut bolts etc complete all as specified and as directed by Engr-in-charge. Note - Rates are inclusive of copper screws with washers for fixing copper strip on Porcelain insulator with minimum size 1 inch and maximum size 1.5 inch with max external dia of screw is 8mm and 2 nos of GI nut for fixing insulator on wall all as per site requirement ,complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable and dislocated air termination rod of any type from floor of any size ,complete all as specified and as directed by Engineer-in-Charge.
S&F in repair, of single pointed soild aluminium rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor all as specified and directed
S&F in repair, of single pointed soild COPPER rod 300mm long and 12mm dia fixed on suitable flat mounted plate and connected with roof/dowen conductor all as specified and directed
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chember of size 200 mm depth, 300mm length and 300mm width ,complete all as specified and as directed by Engineer-in-Charge.
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for monthly/Quarterly/Half yearly L2/L3 eqpts/E&M installations/Lightning arresters test ,complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceable main switches and MCB distribution boards single phase ,complete all as specified and as directed by Engr-in-charge
S&F in repair, MCB distribution board double Door of sheet metal TPN 4 way with 200 amps rated bus bar 415 volts ,complete all as specified and as directed by Engineer-in-Charge. Make: Havells/Legrand/Benlo
S&F in repair, MCB distribution board double Door of sheet metal Single pole and neutral 8 way with 200 amps rated bus bar 240 volts ,complete all as specified and as directed by Engineer-in-Charge.Make: Havells/Legrand/Benlo
S&F MCB ,SPN 240 volt 32/40/63 Amp ,complete all as specified and as directed by Engineer-in-Charge. .Make: Havells/Legrand/Benlo
S&F MCB ,TPN 415 volt 63 Amp ,complete all as specified and as directed by Engineer-in-Charge. .Make: Havells/Legrand/Benlo
S&F MCB single Pole 240 Volts 6 to 40 Amp ,complete all as specified and as directed by Engineer-in-Charge..Make: Havells/Legrand/Benlo
Test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos. 8mm dia 25mm long hex. head screw
M & L for Earthing complete with galvanised steel earth plate electrode of size 600 x 600 x 6mm thick burried directly in ground earth pit not less than 2.25 mtr deep below normal ground level with top edge of the plate vertically to a depth of not less than 1.5 mtr below ground level connection to and including 4mm dia (8 SWG) GI earth wire from earth plate to main switch board including necessary GI bolts, nuts, check nuts, washers, thimble etc to the extend 7.5 mtr as earth lead by means of GI bolts & nuts etc, connecting to LT panel wlith provision of charcoal and salt all as per electrical plate No 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade) excavation and earth work returning , filling, ramming and remove of soil to a distance not exc 50 mtr, make good to match with existing surface and testing on completion.Note:1.After completion if test results are nor satisfied, earthing should be redone by contractor without any extra cost. 2. Contractor should quote the rate deemed to be included with testing
All as per Srl item No 138.00 above but GI Strip of size 25X4mm
All as per Srl item No 138.00 above but using copper plate 60×60cm ×3.15mm thick electrode and 20×3mm copper strip as earthing lead
Supply and fix distribution board made out of sheet metal, powder coated, factory made enclousure, double door type, TPN 4 way vertical type, with 200 Amps rated copper bus bar, neutral bar, earth bar, TP 43 protection including provision of housing of incomer MCCB 63 Amps, triple pole and neutral, 415V, 16 KA breaking capacity and fixing of DB flush to wall surface complete all as specified and directed.
M&L for Sevicing,repair, maintenance of DG set of 100 KVA including dismantling ,opening of unserviceable spare parts of the DG set engine ,cleaning, removing deposits and preparation of surface for painting, checking of its all parts for serviceability and reassembling all serviceable parts with original spares/parts including replacement of defective parts and minor spares required for functioning of DG set 100 to 250 KVA Make : Cumins, complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :-1. All major defective/unserviceable spare parts/items required for repair/maintenance shall be measured and paid separetely under relevent items of Sch 'A' as as a supply only 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set as mentioned below for model and Make of Cummins of capacity 100/250 KVA , for replacing of unserviceable parts for satisfactory functioning of engine ,complete all as directed by Engr-in-Charge.of the following:-
Fuel filter element (primary & secondry).Make:Kirloskar/Bosch/Mico
Lube oil filter element.Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete.Make:Kirloskar/Bosch/Mico
Water temperature guage.Make:Kirloskar/Bosch/Mico
Oil temperature guage.Make:Kirloskar/Bosch/Mico
Oil pressure gauge.Make:Kirloskar/Bosch/Mico
Fan belt set.Make:Kirloskar/Bosch/Mico
Starting ignition switch.Make:Kirloskar/Bosch/Mico
Push Button.Make:Kirloskar/Bosch/Mico
Packing Kit.Make:Kirloskar/Bosch/Mico
Techometer with cable.Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification.Make:Kirloskar/Bosch/Mico
Air filter element of existing specification.Make:Kirloskar/Bosch/Mico
Hose pipe (for make up water connect).Make:Kirloskar/Bosch/Mico
Hose thermostate to radiator.Make:Kirloskar/Bosch/Mico
Dry type air cleaner of size11.5" .Make:Kirloskar/Bosch/Mico
M&L for Sevicing, repair,maintenance including dismantling and opening of unserviceable spare parts of the DG set engine and cleaning, removing deposits and preparetion of surface for painting checking of its all parts for serviceability and reassembling all serviceable parts with original spares including replacement of defective parts and minor spares required for functioning of DG set 40 to 62.5 KVA Make : Kirloskar Green complete engine testing on load to the entire satisfaction of Engr-in-Charge. Note :-1. All major defective/unserviceable spare parts/items required for repair/maintenance shall be measured and paid separetely under relevent items of Sch 'A' as as a supply only 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set as mentioned below for model and Make of Kirloskar of capacity 40 to 62.5KVA for replacing of unserviceable parts for satisfactory functioning of engine ,complete all as directed by Engr-in-Charge.of the following:-
Fuel filter element (primary & secondry).Make:Kirloskar/Bosch/Mico
Lube oil filter element.Make:Kirloskar/Bosch/Mico
Radiator hose pipe set with clamp complete.Make:Kirloskar/Bosch/Mico
Water temperature guage.Make:Kirloskar/Bosch/Mico
Oil temperature guageMake:Kirloskar/Bosch/Mico
Oil pressure gauge.Make:Kirloskar/Bosch/Mico
Fan belt set.Make:Kirloskar/Bosch/Mico
Starting ignition switch.Make:Kirloskar/Bosch/Mico
Push Button.Make:Kirloskar/Bosch/Mico
Packing Kit.Make:Kirloskar/Bosch/Mico
Techometer with cable.Make:Kirloskar/Bosch/Mico
Air filter element of existing specification.Make:Kirloskar/Bosch/Mico
Hose thermostate to radiator.Make:Kirloskar/Bosch/Mico
Dry type air cleaner 11.5" Make:Kirloskar/Bosch/Mico
M&L for Sevicing,repair maintenance including dismantling and opening of unserviceable spare parts of the DG set engine , cleaning, removing deposits and preparetion of surface for painting checking of its all parts for serviceability and reassembling all serviceable parts with original including replacement of defective parts and minor spares required for functioning of DG set 25 KVA Make : Greaves,complete to entire satisfaction of Engr-in-Charge. Note :-1. All major defective/unserviceable spare parts/items required for repair/maintenance shall be measured and paid separetely under relevent items of Sch 'A' as as a supply only 2. Other minor spares/parts required for repair/maintenance shall be deemed to included in quoted rate.
Supply only spare parts of DG Set as mentioned below for model and Make of Kirloskar of capacity 25 KVA for replacing of unserviceable parts for satisfactory functioning of engine, complete all as directed by Engr-in-Charge. Of the following:-
Fuel filter element (primary & secondary).Make:Kirloskar/Bosch/Mico
By pass filter element.Make:Kirloskar/Bosch/Mico
Water temperature guage.Make:Kirloskar/Bosch/Mico
Oil pressure gauge.Make:Kirloskar/Bosch/Mico
Fan belt set.Make:Kirloskar/Bosch/Mico
Shut down valve.Make:Kirloskar/Bosch/Mico
Starting ignition switch.Make:Kirloskar/Bosch/Mico
Push Button LED type.Make:Kirloskar/Bosch/Mico
Fuel pipe any type length and specification.Make:Kirloskar/Bosch/Mico
Air filter element of existing specification.Make:Kirloskar/Bosch/Mico
S&F ,in repair, of fuel injection pump including overhauling and calibration with replacement of worn out parts such as bearing plunger, impeller and oil seal etc of capacity up 50 KVA ,complete all as directed by Engr-in-Charge.
Material and labour for repair to radiator including opening of inlet outlet hose connection, cleaning of complete radiator and repair if any leakage by soldering welding ,refitting and testing of 100/62.5/25/15 capacity Diesel engine ,complete all as specified and directed by Engr-in-Charge .
S&F ,in repair, of injector top, springs etc including calibration of nozzle assembly , complete all as specified and directed by Engr-in-Charge.
S&F ,in repair, of self starter including replacemet of burn field coil, armature and carbon boush holder and carbon bush point of any capacity of DG set, complete all as specified and directed by Engg.in.Charge.
M&L for Dismantling of alternator parts of DG set 100 KVA 3 phase 4 wire ,AC 415 Volts, such as starter & rotor cores, excitor & field coils rectrifies assembly, fan etc.including rewinding of startor field,replacement of exciter assembly and automatic voltage regulator,varnising and damage worn out insulation, cleaning all part by blower, servicing ,rewiring ,varnishing & greasing of required grade to bearing reassembling and testing etc, complete all as spd and directed by Engg-in-Charge.
M&L for Dismantling of alternator parts of DG set 25 KVA 3 phase 4 wire ,AC 415 Volts, such as starter & rotor cores, excitor & field coils rectrifies assembly, fan etc.including rewinding of startor field,replacement of exciter assembly and automatic voltage regulator,varnising and damage worn out insulation, cleaning all part by blower, servicing ,rewiring ,varnishing & greasing of required grade to bearing reassembling and testing etc, complete all as spd and directed by Engg-in-Charge.
S&F DG Set battey of capacity 12 Volts, 150 Ah complete with autobat invatower heat sealed low maintenance battery made with low antimony selenium alloy (LASA) in positive and negative elctrodes,Instant cranking,high density with extreme power with and including polyethylene envelope separators with glass mat vibration resistant for longer life ,complete all as spd and directed by Engg-in-Charge.Make: Exide gen plus/Okaya/Luminous
S&F in repair, fully automatic star delta starter For 10 HP 3 phase,415 volts, oil immersed heavy duty star delta control unit TYPE O.F.A.-40 ,for the following ,all as specified and directed by Engineer in charge. Make- SKN/BENTEX/L&T
M& L for preparation of old painted surface of feeder piller boxes/DB's indoor /outdoor and applaying two coat of synthetic enamal paint,complete as specified and directed by Engineer in charge.
M&L for welding of broken feeder piller doors,indoor/out door using butt hinges appropriate size and making proper locking arrangements of doors ,complete all as spd and directed by Engg-in-Charge.
M&L for spreading stone aggregate of size 20 mm evenly under GO/DO structure, outdoor substns after cleaning the surface,complete all as spd and directed by Engg-in-Charge.
Taking up or down galvanised iron water mains including all fittings of 25 mm bore , including cleaning for refixing or removal to store ,complete all as spd and directed by Engg-in-Charge.
Taking up or down galvanised iron water mains including all fittings of 20 mm bore, including cleaning for refixing or removal to store ,complete all as spd and directed by Engg-in-Charge.
Cutting & Screwing existing steel tubing for alterations or additions (Each cut measured) of 40 mm bore,complete all as spd and directed by Engg-in-Charge.
Cutting & Screwing steel tubing for alterations or additions (Each cut measured) of 25 mm bore ,complete all as spd and directed by Engg-in-Charge.
Cutting & Screwing steel tubing for alterations or additions (Each cut measured) of 20 mm bore ,complete all as spd and directed by Engg-in-Charge.
S&F Galvanised steel tubing, medium grade of 50 mm bore dia including tube fittings viz Tees, sockets bends elbows, Union, nipple etc with screwed and socketed Joints laid in trenches/under floor/under road or laid along the floors ,complete all as spd and directed by Engg-in-Charge.Make: TATA/Swastik/Jindal/Prakash
Ditto as per Srl Item No 162.00 above but for 40mm dia.Make: TATA/Swastik/Jindal/Prakash
Ditto as per Srl Item No 162.00 above but for 25mm dia.Make: TATA/Swastik/Jindal/Prakash
Ditto as per Srl Item No 162.00 above but for 20mm dia.Make: TATA/Swastik/Jindal/Prakash
S&F,in repair, bib tap of size 20mm made with cast copper alloy with crutch or butter fly handle, screwed down and screwed for iron pipe or for brass ferrule and fixed including removal of bip tap of any type and any size ,complete all as spd and directed by Engg-in-Charge.
S&F,in repair,Gun Metal gate or globe valve of 20 mm bores with iron wheel head screwed both ends for iron pipe and fixed complete ,complete all as spd and directed by Engg-in-Charge.
S&F,in repair,Sluice valve, having flanged of class PN 1.6 for 150 mm dia ISI marked confirming to IS- 14846-2000 complete with stainless steel spindle flanged on both ends drilled CI gate with brass ring and iron wheel handle suitable for DI pipe line complete including making joints complete all as spd and directed by Engg-in-Charge. Make: Kirloskar/Venus/L&T/Leader.
S&F,in repair,Sluice valve, in repair, having flanged of class PN 1.6, in repair, , 80 mm dia ISI marked confirming to IS- 14846-2000 complete with stainless steel spindle flanged both ends drilled CI gate with brass ring and iron wheel handle suitable for GI pipe line, complete including making joints all as specified and directed Engr-in-Charge.Make: Kirloskar/Venus/L&T/Leader.
M&L for Fabrication and fixing angle iron frame of equal angle iron/MS rod/MS Sheets/Bends/Tee /Collars/Blank Flange etc of existing size and specification and cut to requied size including welding of tank,valve pit covers of any size and specification , complete all as directed by Engr-in-Charge.
M&L for Boring of holes under road, pavement,hard standing by trenchless technology using ultra sound technique and necessary machine including supply and fix of HDPE pipe of 150 mm dia suitable for 0.4 MPA working pressure in position as directed and level the surface etc , complete all as directed by Engr-in-Charge.
M&L for Construction of valve pit size of 100x100x100 Cm of brick masonary from the top of surface including cover of MS sheet of 3.15mm thick and angle iron 40mmx40mmx6mm with hinges and locking arrangement including painting with two coats of synthetic enamelled paint over a coat of red oxide and grouting with PCC of 1:2:4 plastering in cement morter 1:3, including foundation concrete 1:3:6 and necessary earthwork ,complete all as directed by Engr-in-Charge.
S&F,in repair, Fire brigade inlet connection 2 way of 63 mm dia ,complete all as directed by Engr-in-Charge.
S&F ,in repair, MS fire Hydrant valve 63 mm dia ,single headed ,complete all as specified and directed by Engg.in.Charge.
S&F C P hose pipe of 63 mm dia and 7.5 m length ,complete all as specified and directed by Engg.in.Charge.
S&F Branch pipe of gun metal 63mm dia instantaneous inlet, made threaded outlet,complete all as specified and directed by Engg-in-Charge.
S&F Hose reel drum having minimum 300 mm dia with and including hose reel pipe of 20-25mm dia and 30m length ,complete all as specified and directed by Engg-in-Charge.
S&F,in repair,Cast iron Butterfly Valve 150mm bore ,complete all as specified and directed by Engg-in-Charge.
S&F ,in repair,Cast iron Butterfly Valve 80mm bore ,complete all as specified and directed by Engg-in-Charge.
S&F,in repair, Ball brass valves for 20 mm bore,high pressure,with polyethylene float and flynut,screwed for iron pipe or brass ferrule and fixed ,complete all as specified and directed by Engg-in-Charge.
M&L for disconnecting/dismantling and strip opening of worn out/defective Centrifugal electric motor of capacity10 TO 25 HP any type, taking out brunt stator winding, services cleaning of stator slots, bearing bushes etc rewinding of stator coils with superior quality of copper enamel wire of existing size and specification including insulating material, varnishing and drying, assembling, installing and connected at original location ,complete all as per specified and directed with entire satisfaction of Engineer-in-Charge. Make of winding wire shall be ATLAS/Devi dayal / BPL
M&L for disconnecting/dismantling and strip opening of worn out/defective Centrifugal electric pump of capacity 10 HP mono block type, taking out unserviceable bush, sleeve & sleeve joint etc repair to Impeller & shaft with proper brass brazing welding & lath work, assembling, testing, installation and connections at original location ,complete all as per specified and directed with entire satisfaction of Engineer-in-Charge.
Supply & Fix Black colour Rubber mat made of EPDM Rubber(Ethylene Propylene Diene Monomer Rubber) suitable for sub station of size 1200mmX900mmX15.5mm for protection to shock ,complete all as specified and directed with by Engineer-in-Charge.
M&L for framed work as in doors or gates of angle or other section with gusset plates ,rails ,braces,etc. complete drilled for fixing of steel sheeting or other covering doors etc.to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings, fastening etc (exclusive of steel sheeting or covering,running rails and guides) ,complete all as specified and directed with by Engineer-in-Charge.
S & F Danger notice plate for HT side of the fancing of size 20cm x 25cm of 1.6 mm thick mild steel sheet vitreous enamelled white with letters, figure and conventional skull and bones “DANGER” etc. in signal red colour and fixed with MS clamps made out of 25mm x 3mm MS flat iron bolts, nuts complete including two coats of aluminium paint over a coat of red oxide primer ,complete all as specified and directed with by Engineer-in-Charge.
M & L for HDPE chamber for earth pit including necessory PCC 1:3:6 type B-2 for fixing the PVC inspection chember of size 200 mm depth, 300mm length and300mm width , complete all as specified and directed by Engr-in-charge.
Taking down unserviceable and dislocated conductor strip of any type from wall/floor/roof/ inter connection grid for of any size , complete all as specified and directed by Engr-in-charge.
Supply and fix ,in replacement ,copper strip of 20x3.00 mm as roof conductor and down conductor till test point , complete all as specified and directed by Engr-in-charge.Note:-Copper strip to be jointed through brass nut,bolt and washer only
Refixing the Old serviceable copper strip 20x3 mm on the existing location after necessary repair , complete all as specified and directed by Engr-in-charge. Note-Copper strip to be jointed through brass nut,bolt and washer only
Material and labour for earth pit chamber of size 0.6mx0.6mx0.6m made with PCC 1:2:4 type B-2 including HDPE earthing pit cover inspection chember of size 200 mm depth, 300mm length and300mm width complete all as specified and directed.
M&L for periodical testing and measuring the earth resistance value of the existing earthings / Down conductor / air terminal by means of wheat stone bridge method after disconnecting the earth continuity conductor from the test point , applying secondary voltage across the terminals, maintaining proper record of the measurement in presence of the users rep, MES rep, submitting the test records, pouring saline water in the earth pit to achieve low earth resistance, observing the same complete for monthly/Quarterly/Half yearly L2/L3 eqpts/E&M installations/Lightning arresters test all as directed by Engr-in-charge at site.
S&F Funnel with wire mesh of size suitable for 20 mm dia watering pipe , complete all as specified and directed by Engr-in-charge.
M/S KHUSHI ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .