Project Engineer (EnM), Kathara Colliery
Project Engineer (EnM), Office of the PO, Kathara Colliery
Electrical repairing re-wiring and electrical items for 2 No. sub-station under Kathara Colliery.
2023_CCL_295207_1
KTC/PE(EnM)/E-Tender/23-24/218
Open Tender
Electrical and Maintenance Works
Item Rate
10 days
Office of the Project Officer, PE (EnM), Kathara C
As per NIT
5 documents required · 5 mandatory
₹2,900
29 Dec 2023
4 Dec 2023
14 Dec 2023
5 Dec 2023
13 Dec 2023
5 Dec 2023
5 Dec 2023 - 11 Dec 2023
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS Pvc insulaterd copper conductor single core cable in surface/ recessed medium class PVC conduct, with modular type switch, modular plate with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. 1. Group 'C'
Supplying and fixing suitable size fibre box with modular plate and cover in front on Surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing following modular switch / socket on the existing modular plate and switch box including but excluding modular plate etc.as reqauired. A) 3 pin 5/6 Amps Socket out let
Supplying and fixing stepped tpye electrinic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required
Supplying and fixing sfolloeing way, single pole netural, sheet steel, MCB distribution board, 240 volts, on surface / recess, completed with tinned coper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required (But without MCB/RCCB/ Isolator). I) 2+4 way/8way, Double Door.
Supplying and fixing 5 Amps to 32 Amps rating 240/415 volts, 'C' Curve, Miniature circuit breaker suitable foor inclusive for inductive load of following poles in the existing MCB DB Complete etc. as required I) Single pole and nautral.
Wiring for Circuit / Sub Main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC consult as required. I) 2 x 2.5 Sq. mm + 1 x 2.5 sq.Mm earth wire
Wiring for Circuit / Sub Main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC consult as required 2) 2X 1.5 Sq.mm + 1x 1.5 sq.mm earth wire
Providing and fixing of 6/8 AWG dia G.I wire on Surface or in Cesess for loop earthing as required.
Providing of Aluminium wire twin core 10 mm
Providing and fixing following capacity TP& N disconnector fuse switch unit inside the exiting panel board with ISI marked HRC fuses including drilling Holes in Cubicle, making, connection etc. as required. I ) 100 Amp TP& N
Providing of 32mm dia ISI marked PVC conduit
Total impact of GST for the purpose of CTC
M.k. Traders
RAHIM CONTRACTOR
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .