Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.7 LAccepted-AOC FLAT NO C 401 LORD KRISHNA GREEN OPPOSITE DOON SCHOLAR SCHOOL KEDARPUR DEHRADUN UK 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L1 | Accepted-AOC The bid is accepted being L1 bidder | |
| 2 | L2₹5 L+₹30,300 (6.45%)Rejected-AOC HOUSE NO 8 589 BEHIND PHC HOSPITAL OLD BUS STAND KORBA KORBA CHHATTISGARH 495678 | 495678 | L2 | Rejected-AOC The bid is rejected | |
| 3 | L3₹5.2 L+₹45,300 (9.64%)Rejected-AOC | L3 | Rejected-AOC The bid is rejected | |
| 4 | L4₹5.3 L+₹56,142 (12.0%)Rejected-AOC | L4 | Rejected-AOC The bid is rejected | |
| 5 | L5₹5.5 L+₹75,300 (16.0%)Rejected-AOC | L5 | Rejected-AOC The bid is rejected |
Tender Value
Refer Docs
Closing Date
4 Nov 2023, 6:00 pmClosed
Sh Vinod Doshi, Tech Officer, Offg SBSO
HQ CWE Bikaner
Provn of Chloronome plant for centeralised Chlorination System at KLP water treatment plant at Mil Stn Bikaner.
2023_MES_624533_1
30030/Job/GE (N) BKN/01/E3
Open Tender
Job Works
Works
30 days
GE (N) Bikaner
Please refer Tender documents.
5 documents required · 5 mandatory
₹0
Exempted
24 Nov 2023
21 Oct 2023
6 Nov 2023
21 Oct 2023
4 Nov 2023
21 Oct 2023
Amount
Supply and installation of industrial type chloronome plant of capacity 03 Kg/hr for cholorination of water treatment plant at Bikaner, Specification and quantity of accessories required for complete insallation is as follow:- 1. Roller support - 02 set Bed - Steel as per IS 2062 Roller - Steel EN 8 cadmium plated Shaft - EN 8 BS 970 cadmium plated Make - Industrial device
2. Auxillary container valve with yoke - 02 Nos Valve body - Aluminium silicon bronze Spindle - Mode 400 Gland packing - PTFE Yoke - Forged steel Make - Tekno Make of Yoke - Industrial device
3. Flexible copper connector tube - 02 Nos Tube - Copper cadmium plated 9.5 mm ODX1.5MtrX16SWG Fittings - Brass Brazing - Silver Make - Industrial device
4. Manifold Valve - 02 Nos Body - Aluminium Silicon bronze Spindle - Monel 400 Gland packing - PTFE Make - Tekno
5. Two tonner manifold - 01 Nos Pipe - 20 NB 80 Sch seamless carbon steel as per ASTM 'A' 106, Gr. B Fittings - Forged 30000 Lbs Flanges - Forged 300 ASA - ASTM 'A' 105 Make Industrial device
6. Cholorine pressure gauge with isolation valve - 01 Nos Range - 0 to 16 Kg/cm2 Dial - 150 mm Diaphram - Hastelloy - C Make - General Instruments/Mess Isolation valve - Same as per SI No 04
7. 20 NB Chlorine gas pipeline with fittings - As per requirement
8. Chlorinator isolation valve - 01 Nos Body - Carbon forged steel Size - 20 NB Ball - Hastelloy - C Seat - PTFE End connection - Flanged as per ANSI B 16.5 class 300 Make - Industral device
9. Gas Filter - 01 Nos Body - 80 Sch seamless carbon steel as per ASTM 'A' 106, Gr. B Filter Element - Glass wood Make - Industrial device
10. Pressure reducing valve - 01 Nos Body - Carbon steel ASTMA 105 Size - 20 NB Spindle - Glass fitted PTFE End connection - Flanged as per ANSI B 16.5 class 300 Make - Industrial device
11. Chlorinator - 01 No Capacity - 03 Kg/Hr Model - VW Accuracy - Plus Minus 4% Having the following Accessories:- (A) Pressure gauge with isolation valve (Remotely Mounted) Range - 0 to 16 Kg/ Sqcm Dial - 150 mm Type - Chemical sealed diaphram type Diaphram - Hastelloy - C Make - Industrial device
(B) Vaccum regulator (remotely mounted) Body - ABS Diaphram and seat - PTFE Spindle - Glass filled PTFE Spring - Hastelloy - C Make - Industrial device
C. Vaccum Regulator (Remotely mounted) Body - ABS Seat - PTFE Ball - Glass Spring - Hastelloy - C Make - Industrial device
D. Rotameter Eng fittings - PVC Glass - Borosilicate tapered Float - PTFE Make - Industrial device
E. Flow control valve Body and spindle - PVC Type - V-Notch/Manual Make - Industrial device
F. Vaccum relief valve Body and spindle - PVC Seat - PTFE Spring - Hastelloy - C Make - Industrial device
G. Vaccum gauge Range - 0 to 760 Mg HG Dial - 100 mm Type - Chemical sealed Diaphram type Diaphram - Hastelloy - C Make - General Instruments
(H). Check valve:- Body - PVC Spring - Hastelloy - C Diaphram and O-ring - VITTON Addl check valve - ABS Make - Industrial device
(I). Drain valve:- Body - PVC Float - PTFE Make - Industrial device
(J) Injector:- Body - PVC Nozzle and throat - PVC Make - Industrial device
(K). Inter connecting vaccum UPVC piping from chlorinator to injector
12. 25 NB PVC valve on injector inlet and outlet - 02 Nos
13. 25 mm UPVC pipe for chlorine solutionline 300 mtrs for pre and 150 mtr for post
14. Diffuser - 05 Nos
15. Diffuser isolatio valve for cholorination only - 01 No
16. 25 NB gate valve on booster pump suction and delivery line - 02 Nos
17. 25 NB Y type stainer on booster pump suction line
18. 25 NB MSERW type stainer on booster pump suction line - 48 Mtrs
19. Booster pump with motor- 01 No Head - 50 MWC Capacity - 2 Cum/hr Suction condition - Flooded
20. Pressure gauge with isolation valve on pump delivery line - 02 Nos
21. 25 NB GM check valve on booster pump delivery - 02 Nos
22. Load indicator - 01 No
23. Starter panel - 01 as per requirement
Note:- 1. Contractor has to submit line diagram of complete system before installation for approval. 2. Payment of above subject will be made after complete installation and satisfactory result. 3. Contractor shall quote the rates for complete job only. No itemwise quotations will be accepted.
M/S BHAGWATI CONSTRUCTION COMPANY
LAVISHA TRADERS
HARDIK ENTERPRISES
KUSH ENTERRISES
PARISHI ASSOCIATES
SAHIL BUILDERS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .