Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.8 LAccepted-AOC | L1 | Accepted-AOC Lowest Tenderer | |
| 2 | L2₹3.3 L+₹1.4 L (75.6%)Rejected-Finance | L2 | Rejected-Finance Other than Lowest |
Tender Value
₹1.9 L
EMD Value
₹3,760
Closing Date
4 Aug 2020, 6:00 pmClosed
MAJ AMIT SHANKER JHA
GARRISON ENGINEER MES NASIRABAD - 305 601 (Raj)
COMPLETION OF INCOMPLETE WORK OF SPECIAL REPAIRS TO BLDG NO 37/1 AND 37/2 OF RMS AT AJMER
2019_MES_256430_1
8819/E8
Open Tender
Civil Works
Item Rate
122 days
NASIRABAD
As per NIT
6 documents required · 6 mandatory
₹500
GE Nasirabad
₹3,760
Yes
25 Aug 2020
31 May 2019
6 Aug 2020
31 May 2019
4 Aug 2020
20 Jun 2019
31 May 2019 - 13 Jun 2019
Amount
M & L for rendering 10mm thick in CM (1:4) on fair faces of concrete surfaces of ceiling, finished fair and even complete all as specified and directed.
M&L for preparation of new decorative plastered surface of wall and applying three coats of white wash complete all as specified and directed
M&L for preparation of new decorative plastered surface of ceiling and applying three coats of white wash complete all as specified and directed
M&L for preparation of new decorative plastered surface of wall and applying two coat of oil bound distemper complete all as specified and directed
M&L for preparation of new decorative plastered surface of wall and applying two coat of cement base paint complete all as specified and directed
M&L for preparation of old decorative plastered surface of wall and applying one coat of white wash complete all as specified and directed
Demolition of cement concrete (unreinforced) in floors and paving n.exc 15cm thickness (above or below ground level) complete all as specified and directed.
M & L for 10 mm thick terrazzo topping with 4 to 7 mm size marble aggregate including grinding & polishing with grey cement and no pigment laid over and including 30 mm thick PCC (1:2:4), type B-0, using 12.5 mm graded stone aggregate as in floor, treating the terrazzo surface with bees-wax polish complete all as specified and directed.
M & L for machine cut Kota stone slab in skirting 10 to 15mm thick size not less than 300x150mm & including screed plaster 10mm thick in cement mortar 1:4 laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing with granite finish complete all as specified and directed.
M & L for 40-50mm thick Kota stone slab in cooking platforms, size of full width & length not less than 900mm or full length laid over half brick wall set & jointed in neat cement slurry & pointed in white/coloured cement to match existing complete all as specified and directed.
Supply only PVC dividing strips 1.5mm thick & 38 mm wide and inserted in position to conform to design complete all as specified and directed
M & L for PCC (1:3:6) type C-1 using 20mm graded stone aggregate 50mm thick as in plinth protection finished fair and even laid in bays n.exc 2m in length and joints filled with bitumen mastic 1:3 complete all as specified and directed
M & L for non-skid ceramic coloured tiles white/light coloued of size 300x300x 7mm thick in floors etc set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match the shade of tile laid over and including screed bed 15 mm thick in CM (1:6), 25mm thick PCC (1:2:4) type B-0 using 12.5mm graded stone aggregate complete all as specified and directed.
M & L for glazed ceramic coloured tiles, glossy finish of size 300x200x7 on vertical surfaces of wall such as dados, skirtings etc set and jointed in neat cement slurry and pointed in white cement mixed with pigments to match with the shade of tile over and including 15mm thick screed plaster in CM (1:4) complete all as specified and directed.
M & L for chequered cement concrete tiles 25cm x 25cm x 22mm thick set jointed and pointed in neat cement slurry in floors, with grey cement and pigment over and including 15mm thick screed bed in CM 1:6 & 75mm thick PCC (1:4:8) type D-2 using 40mm graded stone aggregate complete all as specified and directed
Taking down shutters of any description exc 1 sqm and n.exc 2 sqm each leaf and removing from site all as specified and directed.
S & F second class HW Hollock (Terminalia Myriocapra) 35mm thick, factory made, plain framed, paneled shutter (two panels) with panels of 9mm thick BWP marine grade ply wood bonded with high quality liquid phenol formal dehyde synthetic resin adhesive conforming to IS-710. The size of rails & style shall be as per IS-1003 (part-I) kiln seasoned as per IS-1141 & chemically pressure treated as per IS-401 complete all as per specified and directed.
S & F factory made steel windows conforming to IS with side hung shutters including box type hinges with steel handles & steel pag stay (without glazing bars) including fixing of lugs in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) & making good to walls to match the existing incl one coat of red oxide primer all as specified and directed.
S & F factory made steel windows conforming to IS with side hung shutters including box type hinges with steel handles & steel pag stay complete with glazing bars/dovetailed welded including fixing of lugs in PCC (1:2:4) type B-1 (using 20 mm graded stone aggregate) and making good walls & cills to match the existing complete all as specified and directed.
M & L for mild steel framed guard bars of 12mm square conforming to Fe-290 Gde E-165 welded to steel ventilators complete all as specified and directed.
S & F factory made solid pannel PVC door shutter 30mm thick (style) consisting of frame made out of MS tubes for top and bottom rail. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheet for top rail, lock rail & bottom rail on either side and as gap insert for top rail and bottom rail, panelling of plain colour PVC sheet to be fitted in the MS frame welded. sealed to the stiles and rails with suitable PVC sheet beading and joined together with solvent cement, supplying and fixing in the frame at site as per specification and drawings on page 146 of SSR Part - II 2004 complete all as specified and directed. NOTE: Cadmium screws shall be used for fixing & fixtures.
S & F galvanized mild steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm and fixed with wooden beads tinned tacks or galvanized wire staples complete all as specified and directed
S & F galvanized mild steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm and fixed to steel frames with tinned tacks or galvanized wire staples complete all as specified and directed
S & F galvanized mild steel wire cloth 0.50 mm nominal dia of wire and average width of aperture 1.18 mm and fixed to steel frames with existing flat iron with tinned tacks or galvanized wire staples complete all as specified and directed. NOTE: Old flat iron retrieved shall be reused.
Hacking out old, broken glass (any thickness, size, quality or description) from metal frames including punching or drilling out old glazing pins/spring clips complete all as specified and directed.
S&F 3.00 mm thick sheet glass, ordinary quality & glazing with oil putty not exc 0.50 Sqm each pane complete all as spd & directed.
S & F mild steel 300 mm ordinary long rat tail rod pattern spring including roller and roller plate complete all as specified and directed.
M&L for preparation of new surface of wood and wood based material of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st quality) over a coat of pink primer complete all as specified and directed.
M&L for preparation of new surface of steel material of any description over 10cm width or girth and applying two coats of synthetic enamel paint (1st quality) complete all as specified and directed.
M&L for preparation of old surface of wood and wood based material of any description over 10cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified and directed.
M&L for preparation of old surface of steel material of any description over 10cm width or girth and applying one coat of synthetic enamel paint (1st quality) complete all as specified and directed.
Taking down pelmet any size with rod and bracket fixed to wall complete all as specified and directed.
S & F fancy type pelmet rod of aluminium, 22mm dia powder coated complete all as specified and directed.
S & F brass, decorative type knobs with bracket fixed at end of pelmet rod suitable for 22mm dia complete all as specified and directed.
Taking up or down steel tubing / connection & removing from site complete all as specified and directed for bore of pipes as mentioned in Srl item No. :- 36.00 to 38.00
15mm bore
20mm bore
40mm bore
S & F steel water tubing, medium grade, galvanized with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed for bore of pipes as mentioned in Srl item No. :- 40.00 to 42.00
15mm bore
20mm bore
Refixing only old serviceable GI tubing, medium grade, with new fittings if required including cleaning and fixed complete to walls and ceilings or laid in floors complete all as specified and directed for bore of pipes as mentioned in Srl item No. :- 43.00 to 45.00
15mm bore
20mm bore
40mm bore
Fixing only rotational moulded synthetic (HDPE) water storage tank 500 litre capacity hoisted and fixed in position all as specified in SSR Part-I complete all as specified and directed. NOTE :- PVC Water tank shall be issued under Sch “B” free for fixing only.
S & F ball valves high pressure and of PTMT with epoxy coated aluminium rod and high density plastic ball screwed for iron pipe of 20mm bore minimum weight 210 gms complete all as specified and directed.
S & F in repair bib taps ISI marked, cast copper alloy, chromium plated, fancy type with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule and fixed for 15 mm bore of pipe complete all as specified and directed.
S & F stop valves cast copper alloy chromium plated, fancy type screwed down high pressure with long shank & cup (concealed type) screwed both ends for iron pipe or for union 15 mm dia, ISI marked complete all as specified and directed.
S & F in repair brass tubular towel rail, chromium plated, 20mm dia, 60cm long between flanges including brackets (02 No) of brass , chromium plated complete all as specified and directed.
S & F in repair brass, chromium plated brackets suitable for tubular towel rail 20mm dia complete all as specified and directed.
Taking down old unserviceable WHB and S&F vitreous China, WHITE, wash hand basin, flat back of size 550 x 400mm including PVC waste pipe of suitable size complete all as specified and directed
S&F in repair pillar tap, 15mm bore, cast copper alloy, chromium plated, fancy type with capston head, screwed down high pressure with or without lettred hot or cold with long screw shanks and fly nuts screwed for iron pipe complete all as specified and directed
S & F PVC connection, heavy duty 15 mm bore, 45 cm long with two Nos PTMT nuts at both ends of approved quality complete all as specified and directed
S & F in repair brass chromium plated shower rose of 100 mm size with swivel joints, including fixing to steel pipe or union of 15 mm bore complete all as specified and directed.
Taking out old unserviceable water closet (squatt pattern) and S & F Vitreous China, Squatting pan of pattern ‘long pan’ size 580mm, white with ‘P’ or ‘S’ trap, front or back inlet and foot rest, any pattern including connection to trap and to flushing pipe, anti syphonage pipe and making good the floor to match the existing complete all as specified and directed
S & F in repair PVC valve less, syphonic action type flushing cistern, ISI marked, 10 litre capacity, low level, white/ivory colour, with inlet, ball valve, float, handle fixed with PVC rawl plug of suitable size complete all as specified and directed.
Taking down old unserviceable kitchen sink and S & F sink with drainage board made of stainless steel, 1mm thick, kitchen, with plug, washer and wastes, including fixing on existing cantilever brackets and connecting union or pipe over all size not less then 1145X410 bowl size 560 x 410 x 200mm complete all as specified and directed.
M & L for brick work with with fly ash bricks, old size, straight or curved on plan to any radius, in half brick thick wall built in CM 1:4 complete all as specified and directed.
Extra over random rubble stone walling for hammer dressing to face stones and dressing to face beds & joints, hammer dressing with maximum depression on face from straight edge held against the dressed surface not exc 20mm on (Sand stone) complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement including forms, moulds, metered /stopped ends etc complete all as specified and directed.
Dismantling stone slab & tile of any description or thickness in floor/roof/shelves/lintel/chajja/manhole cover slab etc, laid dry & pointed in cement mortar complete all as specified & directed.
M & L for 50mm thick roughly dressed sand stone slab for man hole covers & chajja n. exc. 2mtr in length set, jointed and pointed in CM (1:4) complete all as specified and directed.
M & L for machine cut Kota stone slab including rubbing and polishing in shelves in almirah, 20 to 25mm thick set & jointed in cement mortar (1:4) including cutting grooves for insertion of slab complete all as specified and directed.
S & F in repairs 100mm dia PTMT grating (Mini Wt 25 grms) without hole complete all as specified and directed.
S & F in repairs 100mm dia PTMT grating (Mini Wt 25 grms) with hole complete all as specified and directed.
Taking up/down AC soil, waste and vent pipe 100mm bore size set in CM from walls/trenches complete all as specified and directed.
S & F PVC (SWR) pipes, 110mm bore, single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed.
S & F PVC (SWR) pipes, 75mm bore single socketed, in any length with rubber ring joints, fixed to walls complete all as specified and directed.
S & F PVC (SWR) 110mm bore bends (any radius) fixed with cement joint complete all as specified and directed.
S & F PVC (SWR) 110mm bore branch piece (Tee) fixed to walls with cement joint with or without oval access door complete all as specified and directed.
S & F PVC (SWR) 110x110 mm bore 'P' trap fixed with cement joint complete all as specified and directed.
S & F PVC (SWR) 75mm bore vent cowl complete all as specified and directed.
S & F PVC (SWR) 75mm bore reducer complete all as specified and directed.
Disconnecting of unserviceable sub main wiring of any size from service connection cable hanging with porcelain insulator including GI wire of any size and removing from site and making good disturbed surfaces complete all as specified and directed.
Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories and removing from site and making good disturbed surfaces complete all as specified and directed.
M & L for point wiring with 1.5 sqmm single core multi stranded copper conductor PVC insulated sheathed (FRLS) cable 1100 volts grade drawn through and including non metallic rigid PVC concealed conduit 20mm dia or higher with all PVC conduit accessories with PVC sleeves/dash fasteners and cadmium plated screws as per IS with suitable size of anodised switch box concealed in wall for mounting of modular switches, sockets, fan regulators etc with modular cover plate with frame for suitable module as per site requirement with earth continuity conductor of size 1.5 sqmm single core copper conductor multistranded cable connected to common earth dolly for the following complete all as specified and directed
One light / fan / bell point controlled by one, one way 5 Amp switch.
One 3 pin 5 Amps socket outlet on same board with other switches.
One 3 pin 5 Amps socket outlet on independent board.
All as per item No 78.00 here-in-before but 2.5sqmm single core multi stranded copper conductor PVC insulated unsheathed (FRLS) cable 1100 volts incuding 2.5sqmm stranded copper conductor (FRLS) PVC insulated greeen in colour as continous earth conductor connected to common earth and earth dolly with all accessories one 5 pin 5/15 Amp socket on independent board complete all as specified and directed
S & F switch piano type, flush button, single pole, one way, 15 Amps complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F switch piano flush type, 5/6 Amp, 240 volt, single pole, two way switch complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F socket outlet 15 Amps, 5 pin, flush type, complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F socket outlet 5 Amps, 5 pin, flush type, complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F bell push, flush type, 5 Amp, complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F ceiling rose, surface bakelite 65 x 17.5mm, three terminal complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F bell electric, AC 230 volts, single phase, complete all as specified and directed. Make : CONA / SSK / ANCHOR
S & F ceiling fan regulator stepped type 230 volts suitable for 1200mm/ 1400mm sweep complete all as speicifed and directed. Make : CONA / SSK / ANCHOR
Fixing only super box rail type luminaries for single 40 watt fluorescent lamp comprising of CRCA sheet steel stove enamelled gray box type channel with white cover complete with ballast type BCCB, lamp holders, starter, fixed to wall with and including 2 Nos wooden round block of Ist class HW (teak) 8 cm dia & 4 cm depth open recessed including flexible copper cable of size 24/0.20 three core of required length from ceiling rose to tube light fitting complete all as specified and directed. NOTE : Fluorescent tube rod 4’ x 40 watt with box type fittings with all accessories shall be issued under Sch ‘B’ free for fixing only.
S & F bulk head light fittings conforming to sketch No 11 of electric plate No 6 of SSR Part-I (Without bulb) complete all as specified and directed
S & F galvanised steel tubing of size 40mm bore 3M long with 2 Nos of GI bend medium grade for service bracket including clamps and nuts bolts required complete all as per specified and directed.
S & F sheet metal enclosure, distribution board, double door, powder coated, semi concealed in wall for housing MCB's with and including 200 Amp rated copper bus bar of following capacity complete all as specified and directed:-
08 Ways, 240 volts SPN
04 Ways, 240 volts SPN
S & F isolator single pole & neutral, 40 amp, 240volts complete all as specified and directed.
S & F MCB of curve 'C' conforming to IS 8828 of 1996 following capacity complete all as specified and directed. NOTE FOR ITEM NO 94.00 to 100.00 :- (i) Make Legrand / Schneider / ABB / C&S (ii) MCCB and DB should be of same make (iii) Blanker plates should be provided in MBC DB in blank holes (iv) Cable should be fixed through lugs of proper sizes
SP 5 to 10 Amp, 10 kA
SPN 20 Amp, 10 kA
S & F PVC insulated twin core multi-stranded aluminium conductor 10 sqmm, 1100 volts, heavy duty, served with inner sheathing of PVC tape and over all PVC sheathed in service connection suspended by insulating hangers not more than 1 metre apart & passing through service bracket including 4mm dia GI wire with one twin core cable complete all as specified and directed
All as per item No 101.00 above but in non metallic rigid PVC conduit 25mm dia fixed on wall/ceiling for service line with necessary hook fixed in wall etc complete all as specified and directed
S&F batten lamp holder, PVC/polycarbonate type with back plate suitable for batten lamp holder complete all as specified and directed. Make : Anchor / SSK / Cona
M & L for earthing complete with galvanized iron earth plate electrode 60 cm x 60 cm x 6 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level connected to galvanized earth lead wire 4.00 mm dia by means of bolts, nuts, check nuts and washer of galvanized iron or steel all as shown in electric plate No 5 of SSR Part-I connected to continuous earth wire on main switch board all as specified or indicated and testing on completion including provision of earth wire protection by 15 mm dia medium grade GI pipe and watering pipe shall be 20 mm bore, GI medium grade including excavation & earth work, PCC pit with RCC cover, charcoal, salt funnel, GI wire upto 7.5 m length complete all as specified and directed
JWALA ENTERPRISES
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .