Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.8 CrAccepted-AOC | ₹12.8 Cr Quoted ₹13.0 Cr | L1 | Accepted-AOC L1 |
| 2 | L2₹14.5 CrRejected-Finance NOT SPECIFIED | ₹14.5 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹17.7 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹17.7 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹20.0 CrRejected-Finance | ₹20.0 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | Rejected-Technical BAKRON KA WADA NEAR NEELAM CINEMA JODHPUR ROAD BALOTRA BARMER RAJASTHAN 344022 | BALOTRA | BARMER | RAJASTHAN | 344022 | - | - | Rejected-Technical Does not qualify for opening of cover-2 as the bidder has not submitted EMD being un-enlisted firm due to change in constitution under process. |
Tender Value
₹9.2 Cr
EMD Value
₹7.8 L
Closing Date
1 Feb 2023, 6:00 pmClosed
Chief Engineer Pune Zone
Chief Engineer Pune Zone Dakshin Kaman Marg CAMP, Pune PIN- 411001
COMPLETION OF INCOMPLETE WORK FOR PROVISION OF OTM ACCOMODATION FOR CERTAIN REGT (PH I) AT DEOLALI
2022_MES_567291_1
CA NO. CEPZ/DEO/TOKEN-20 OF 2022-23
Open Tender
Civil Works
450 days
Deolali
Class S and category a(i)
Also refer NIT
8 documents required · 8 mandatory
₹3,000
GE Deolali
₹7.8 L
Yes
3 Mar 2023
5 Dec 2022
3 Feb 2023
5 Dec 2022
1 Feb 2023
14 Jan 2023
6 Dec 2022 - 17 Dec 2022
Amount
(NOTE : Schedule "A" Part-I (A & B) are not Pre-Priced by MES and the Rates indicated as "Rs 0.00" under Col 6 indicates this fact only)
SCHEDULE PART- I (A) (BUILDING WORKS- PARTLY COMPLETED BY THE DEFAULTING CONTRACTOR)
Note for Sl Item No 1.50 to 1.90: (a) Lumpsum quoted by the tenderer against BOQ Item Nos. 1.50 to 1.90 shall be deemed to include for all aspects as per execution & handing over of work in normal contracts.
(b) Lumpsum quoted by the tenderer against BOQ Item Nos. 1.50 to 1.90 shall be deemed to include for rectification of all defects (Indicated/ Noticed subsequantely) {except strengthening measures as mention in NOTE at srl No. 1.40 here-in-below} in the work executed by defaulting contractor.
Note for Sl Item No 1.50, 1.60 & 1.70 : Strengthening Measures to Defective Works in Completed/ Partially Completed Work shall be measured & paid separately under BOQ items under Schedule "A" Part-XIII (A) &(B) and shall not be included in quoted Lumpsum of respective items.
Construction & Completion of left over work of Block for Single living Accn for 23 Hav and 134 OR(G+2) including dining hall for 269 Hav/OR and 2 Nos Cook house for 134 Hav/OR all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on drawings, specifications, tentative measurements (stages) indicated in Annexure-1 to Schedule "A" Part 1(A) including rectification of defects in the executed work (Quantities/ tentative measurements indicated in Annexure-2 for rectification of defects are just for guidence only).
Construction & Completion of left over work of Block for Single living Accn for 22 Hav and 133 OR (G+2) including dining hall for 269 Hav/OR and 2 Nos Cook house for 134 Hav/OR all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on drawings, specifications, tentative measurements (stages) indicated in Annexure-II to Schedule "A" Part 1(A) including rectification of defects in the executed work (Quantities/ tentative measurements indicated in Annexure-2 for rectification of defects are just for guidence only).
Construction & Completion of left over work of Block for Mess (Clubs) for 36 JCOs all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on drawings, specifications, tentative measurements (stages) indicated in Annexure-III to Schedule "A" Part 1(A) including rectification of defects in the executed work (Quantities/ tentative measurements indicated in Annexure-2 for rectification of defects are just for guidence only).
Construction & Completion of left over work of Block of Scooter shed for 8 scooters all as shown on drawing and as specified. Note:- Amount of left over work shall be worked out by the tenderer based on drawings, specifications, tentative measurements (stages) indicated in Annexure-V to Schedule "A" Part1(A) including rectification of defects, if any in the executed work.
SCHEDULE "A" PART - I (B) (BUILDING WORKS - NOT STARTED BY THE DEFAULTING CONTRACTOR)
Construction of Septic tank for 10 users all as shown on drawing and as specified.
Construction of Septic tank for 25 users all as shown on drawing and as specified.
Construction of Septic tank for 300 users all as shown on drawing and as specified.
Construction of Soakage Well of size 1.2 m dia and 3.0 m depth all as shown on drawing No CEPZ/2019/TD/03 and as specified.
Construction of Soakage Well of size 1.8 m dia and 4.5 m depth all as shown on drawing No CEPZ/2019/TD/03 and as specified.
Construction of Soakage Well of size 3.6 m dia and 6.0 m depth all as shown on drawing No CEPZ/2019/TD/03 and as specified.
Construction of Steel gate 6m wide and 2.7 m high all as specified and shown on drawing.
Construction of Steel gate 3.5m wide and 2.1 m high all as specified and shown on drawing.
NOTE: Schedule ‘A’ Part II, III(A), IV(A), V(A), VI(A), VIII(A), IX, X, XI & XII are Prepriced by MES. Bidders shall insert their lumpsum amount in the blue coloured field under Col-6 only.
Total amount of Sch 'A' Part-II (Internal Water Supply)
Total amount of Sch 'A' Part-III(A) (Internal Electrification)
Total amount of Sch 'A' Part-IV(A) (External Water Supply)
Total amount of Sch ‘A’ Part -V(A) (External Electric Supply)
Total amount of Sch 'A' Part-VI(A) (Lightning Protection)
Total amount of Sch 'A' Part-VIII(A) (Solar Water Heater System)
Total amount of Sch ‘A’ Part-IX (Road)
Total amount of Sch ‘A’ Part-X (Sewage Disposal)
Total amount of Sch ‘A’ Part-XI (Area Drainage)
Total amount of Sch ‘A’ Part-XII (Fencing, Gate & Compound Wall)
Total amount of Sch ‘A’ Part-XIII SEC 'A' (Strengthening measures to defective works in completed /partially completed work)
SCHEDULE "A" PART - III (B) (INTERNAL ELECTRIFICATION))
Supply and fixing LED light fitting mirror type with high output diffuser 2 feet, 05 watt 220V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. MAKES: Havells Cat No LUMILINEVS5WLED865SPCWH, Bajaj Cat No BCLSB 05 W WH/ Crompton Cat No TRIMLINE LDL-05-CDL or of equivalent make specified here-in-after.
Supply and fixing LED light fitting 20W, 220V, AC 4 feet tube light fitting, extruded polycarbonate housing and robust construction LED lighting with lumen output, environment friendly, energy efficient CRI-6500K, PF not less than 0.95, fixed on PVC square for mounting the fitting & electrically connecting with three core 23/0.0076 PVC insulated multi light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. MAKES: Havells Cat No LHEXBLP7PN1W020 / BENLO Cat No BL04BAT20WT5 / HALONIX Cat No HLB-08-20-CW-LP or of equivalent make specified here-in-after.
S&F Surface mounted LED 9/10 Watts, 2 feet tube light fitting, extruded polycarbonate housing and robust construction LED lighting with lumen output environment friendly energy efficient CRI-6500K, PF not less than 0.95, fixed on PVC square for mounting the fitting & electrically connecting with three core 23/0.0076 PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. MAKE : Havells Cat No LHEXBLP7INIW009/ Halonix Cat No HLB-07-10-CW-IP/ Wipro Cat No LL20-XXX-65 NE3 **6500K or of equivalent make specified here in after.
Supply and fixing LED Reccess mounted luminaire 36 watt, of size 4°x1 environment friendly, suitable for grid/ armstrong ceiling, electrically connecting with three core 23/0.0076 PVC insulated muti stranded copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. MAKES: Havells Cat No PLUTONEO4X1PLR36WLED840S / Bajaj Cat No BZRSLL B6LLED GX WH SD / Halonix Cat NoHLFPR14-0636-CW or of equivalent make specified here in after.
S&F LED Recces mounted luminaire 34/36 Watt Recess mounted suitable for grid/Amstrong ceiling 2x2 LED luminaire pluto neo panel with glare free soft light watt complete pre-wired electrically connecting with three core 23/0.0076 PVC insulated multi stranded copper flexible cable from ceiling rose to light fitting (connector of lamp fitting) and one for earthing complete all as specified and directed. MAKES: Bajaj Cat part No BZRSQL 36W LED ODSD/ Havells Cat No PLUTONEO 2X2PLR 34W LED 8405 / Halonix Cat No HLFPR22-02-34-CW-R-HLI or of equivalent make specified here-in-after.
S & F lamp holder,PVC/Polycarbonate type with back plate suitable for batten fitting including S&F LED lamp 12 watt 230 V complete.
S&F LED table lamp 4/ 5W pre wired complete all as specified and directed. MAKES: Havells Cat No LHEXBZP7BN1W004 / Crompton Cat No LED5WTBL-A198-BL/ Bajaj model soft light or of equivalent make specified here-in-after.
S/F MCB TP& N 415 Volts 63 Amps 10 KA 'B' series
S/F MCB TP& N 415 Volts 40 Amps 10 KA 'B' series
S/F MCB single pole 240 Volts 6 Amps to 32 Amps 10 KA 'B' series
S/F MCB SP & N 240 Volts 6 Amps to 32 Amps 10 KA 'B' series
S/F MCB SP & N 240 Volts 63 Amps 10 KA 'B' series
S & F blanking plate of PVC complete all as directed.
S & F exhaust fan, single phase, heavy duty, 225 mm sweep,1400 RPM including fixing of mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, and connecting with and including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed.
S & F exhaust fan, single phase, heavy duty, 350 mm sweep,1400 RPM including fixing of mounting frame in the round hole cutting in the wall, by means of rugged bolts, nuts and washers etc, and connecting with and including three core copper conductor flexible cord of 0.5 Sqmm cross sectional area of required length from ceiling rose to the porcelain connector block of the exhaust fan complete all as specified and directed.
S&F LED building security light fitting 35/36 Watt 230V AC outdoor type with high pressure die cast aluminum housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. MAKES: Philips Cat No BRPO30 LED35 CW MR PSU GR DX/ Bajaj Cat No ENXT P35L WH PO PC SD/ Crompton Cat No TRP-400-35-57-SL-LM-NSR or of equivalent make specified here in after.
Earthing complete with galvanised steel earth plate electrode 600 x 600 x 6.0 mm thick, buried vertically in ground (Earth pit not less than 2.25 metres deep below normal ground level and top edge of the plate not less than 1.5 m below ground level), connected to galvnised steel earthing lead wire 4 mm dia, by means of bolts, nuts & checknuts and washers etc; GI pipe 15 mm dia light grade pipe for protection of G.I earth lead wire, both to be provided to the extent of 7.5 metres, all as shown on electrical plate No 3 of MES SSR-2009 Part-I, other end connected to electrical main switch board (inside the bldg) GI protection pipe buried in ground, laid under floors/plinths or fixed on walls or concealed in walls etc; with provision of mixture of charcoal dust & common salt packed upto minimum 150 mm all around the earth plate , including PCC 1: 2 : 4 type B-1 earth pit with M.S angle iron frame, cast iron cover with locking arrangement, with G.I 20 mm dia medium grade pipe and M.S funnel with wire mesh for watering arrangement, including necessary excavation and earth work in any type of soil / strata & testing on completion complete all as specified, directed and shown on drgs.
M & L for LT Panel wall mounted type suitable for mounting following complete with aluminium busbar of 200 Amps complete. a) MCCB 4 pole 150 Amps 25 KA - 01 No b) MCCB 4 pole 63 Amps 25 KA - 03 Nos
S&F RG-11 coaxial cable in and including 20 mm dia PVC conduit accessories, concealed in wall for TV point
S&F Wiring with PVC insulated, sheathed cable 3 pair with copper wire (Copper wire of 0.5 mm dia and resistance of cable not less than 100 ohms per Km) in and including 20 mm dia PVC conduit and accessories, concealed in wall for P&T socket.
S&F TV single outlet with mounting block.
S&F Telephone jack single with shutter socket with PVC mounting block.
SCHEDULE "A" PART - IV (B) (EXTERNAL WATER SUPPLY)
Supply and fixing and testing CI sluice valves 80 mm bore, both ends flanged and drilled, with stainless steel spindle , bannet wedge stuffing box, gland thrust plate, hand wheel made out of grey CI complete suitable for tested hydrostatic pressure PN 1.6 ISI marked. including joints and jointing material.
Ditto- all as per item No 6.40 above but 100 mm bore.
Ditto- all as per item No 6.40 above but 200 mm bore.
Material & labour for PCC solid block masonary chamber using gde C5 blocks (valve chamber) built in cm 1:6 for sluice valve etc. all shown on Drawing No CEPZ/93/TD/20 of internal size 900x900x950mm
Note for item No. 6.70 above :- Excavation and earthwork required will be measured and paid under relevant items of Sch 'A' Part IV (A)
SCHEDULE "A" PART - V (B) (EXTERNAL ELECTRIC SUPPLY)
M&L for providing sleeves with heavy duty alkaline PVC pipe 25 mm dia from GOD to transformer etc all as specified and directed.
Supply & fix FRP type looping box for street light controls consisting of MCB SP 2.5 A- 01 No.
S&F LED street light fitting minimum 70 watt rating separate individual peanut plated lens and aluminium reflectors housing should be made of LM6 Pressure dia cast aluminum. Optical cover should be only Toughened Glass only Impact resistance > IK07/ IK08 IP Protection not less than IP-65, Protection should be class I Vibration should be as per IEC-60598, Product standard IS 10322/EC protector should be of same make, Driver should be V-140, V-270V, Driver frequency 50Hz Power factor > 0.9, Lumen output should not be less than130 Lumen/Watt and Luminaire Driver ckt should be mounted type weather proof construction, with separate surge protection device 5 KA rating and separate connector block for termination of incoming cable connection all as specified and directed by Engr-in-Charge. MAKES: Phillips Cat No BRP032 LED70CW MRPSU GR DX/ Havells Cat No ENDURAOMNIPLUSSL70WLED757SASYTOPC / Crompton Cat No CRP-70/57/SL-GL-NSG or of equivalent make specified here in after.
M&L for Provision of earthing with 600x600x6.3mm galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including G.I. Strip of size 32x6 mm by means of bolts,nuts and check nuts and washers of galvanised steel (and 50mm dia GI light grade pipe for protection of G.I strip) to the extent of 7.5 metres as earthing lead and connecting to the eqpt, viz transformer, L.T. kiosk, H.T.lightening arrestors etc. including charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, M& L complete including excavation and earthwork in any type of strata and testing complete all as specified and directed.
M&L for Pole earthing complete with galvanised steel earth plate electrode 600x600x6.3 mm, burried vertically in ground ( earth pit not less than 2.25 m deep below normal ground level) with top edge of plate vertically to a depth not less than 1.5m below ground level, connected to galvanised steel earth lead wire 4.00 mm dia ( 8 SWG) of any length as reqd at site, by means of bolts, nuts, check nuts and washers of galvanised steel, earth lead wire encased in and including 15mm bore G.I. light grade pipe from earth plate upto pole, upto 2.40 M height from GL by means of and including 25x3 mm M.S.F.I. Clamps, bolts, nuts and washers etc. and GI Earth lead wire then fixed bare along the pole and connected to O/H continuous earth wire for providing earthing to H.T/L.T poles/feeders, gang operated air break switches etc. with provision of charcoal dust and common salt packed all around the earth plate, including necessary excavation and earth work in any type of strata and testing complete all as specified and directed and shown on electrical plate No.3 of SSR Part I (2009). Including earth pit chamber all as directed complete.
Supply, install testing and commissioning weather and vermin proof L.T. feeder pillar box (Panel board)factory fabricated out door cubicle/kiosk type totally enclosed made out of 3.15 mm thick sheet metal enclosure of suitable size, with angle iron base frame of M.S. angle 50x50x6 mm suitable for operation on 3 phase 4 wire, 440 volts 50 HZ system, with hinged panel doors (covers) on two sides with handles, bottom gland plate and locking arrangement consisting of sufficient Nos of circular cable entry holes at bottom only with suitable PVC/rubber/wooden bushes to prevent ingress of water/vermin etc, inside the enclosure, the required nos of holes to be fixed with chromium plated brass cable glands for cable entry and exit complete with necessary internal wiring with stranded copper conductor PVC insulated cables of adequate size, duly spray painted grey hammer tone with one coat of red oxide primer and two coats of synthetic enamel paint of gray or any other approved colour, including connecting with L.T. armoured incoming and outgoing cables and including required sizes of cable lugs of aluminium complete all as specified and directed and consisting following.
(a) Bus bars of copper strips of 600 amp current rating capacity TPN, minimum 600 mm long or of length as actually required at site for 3 phase and half size for neutral, mounted on epoxy/FRP bus bar insulators-1 set
(b) MCCB TPN , 400 Amp, 50 KA 415 V, - 1 No. (incoming)
(c) MCCB TP, 100 Amp, 25 KA 415 V - 5 No. (outgoing)
(d) MCCB TP 63 Amp, 25 KA 415 V - 4 No. (outgoing)
(e) MCCB SPN 32 Amp, - 2 No. (outgoing)
(g) Indicator lamps (RYB) one set
(h) Timer switch 240 V, 50 HZ single phase 16 Amps for automatic ON/OFF operation of street lights feeder complete with 1 No contactor ML 4 all duly wired for automatic operation of street lights cat No ET 100 of L&T or other makes specified -( 01Sets)
Laying only and jointing,testing, commissioning LT cable 1100 volts grade, XLPE insulated armoured and PVC sheathed with stranded aluminium conductor heavy duty, conforming to IS 1554 Part I / ISI marked, to be laid in trenches, fixed along the poles or through G.I. Pipe laid under floors road etc; fixed concealed in walls encased in G.I. Pipe etc. complete of following sizes:-
(a) 25 Sqmm 4 Core
(b) 16 Sqmm 4 Core
(c) 10 Sqmm 2 Core
Note for item No 8.60 to 8.70 above:- XLPE cable shall be issued under Sch B free for laying only.
SCHEDULE "A" PART - VI (B) (LIGHTENING PROTECTION)
M&L for Provision of earthing with 600x600x6.00 mm Galvanised steel earth plate electrode buried vertically in ground (earth pit not less than 2.25 metre deep below normal ground level) with top edge of the plate at a depth of not less than 1.5m below ground level, connected to and including Galvanised steel Strip of size 32x 6 mm by means of bolts,nuts and check nuts and washers of galvanised steel and 50 mm dia GI light grade pipe for protection of GI strip to the extent of 7.5 metres as earthing lead including charcoal dust and salt packed all around the earth plate in the earth pit all as per electrical plate No. 3 of SSR Part I (2009) including PCC foundation / chamber in mix 1:2:4 type B1 with M.S. angle iron frame, C.I. Cover with provision of locking arrangement and 20mm dia light grade G.I. Pipe from top edge of the earth plate upto M.S. funnel with wire mesh provided inside the concrete earth pit for watering arrangement, M& L complete including excavation and earthwork in any type of soil strata and testing complete all as specified and directed.
SCHEDULE PART - VII (COOLING APPLIANCES)
Fixing only water coolers electric driven (single phase), having approx storage capacity of 80 liters and nominal cooling capacity of 40 Liters/hour complete all as specified and directed.
Ditto- all as per item No 9.20 above but storsge capacity of 120 litres and normal cooling capacity of 60 litres/ hour.
Note for item Nos 9.30 & 9.40 above : Water cooler shall be issued under sch 'B' free for fixing.
SCHEDULE PART - VIII (SECTION 'B') (SOLAR WATER HEATER SYSTEM)
Installation only solar water heater system with heat exchanger type for cold region of 200 ltr capacity with byelectric back up of 3.6 KW and make up water tank .
Note for item No 9.70 above : Solar water heater including make up water tank shall be issued under sch 'B' free for fixing.
SCHEDULE "A" PART - XIII (B) (STRENGTHENING MEASURES TO DEFECTIVE WORKS IN COMPLETED/ PARTIALLY COMPLETED WORK
Providing encasement to columns/beams/ retaining walls etc. with free flow high strength non shrink micro concrete M-35 using single component cement micro concrete shrinkage components 30% saturated dry stone aggregate and 70% microconcrete, water cement ratio shall be maintained properly as per manufactures specifications to achieve dense solid mass prepared micro concrete shall be poured properly as per in prefixed holding boards slurry tight form work properly aligned to required size and shape and well oiled air bubbles if any shall be removed by tapping the boards removing the boards after 24 hours and curing the micro concrete thoroughly for 14 days cost inclusive of curing etc. complete. (Excluding shuttering, reinforcement and preparation of damaged surface)
Tentative bifurcation of quanities is as under :- (a) Quantity for 23 Hav & 134 OR Accn = 58564.80 Kg (b) Quantity for 22 Hav & 133 OR Accn = 69300.00 Kg (c) Quantity for Mess (Clubs) for 36 JCOs = 17010.00 Kg
Providing and injecting epoxy grout including structuring of crack in the body of slab / beam / beam column joint by sand blasting, fixing inlet tube arrangement including cost of materials, machinery required for the work and labour charges etc. complete.
Tentative bifurcation of quanities is as under :- (a) Quantity for 23 Hav & 134 OR Accn = 202.00 Kg (b) Quantity for 22 Hav & 133 OR Accn = 151.00 Kg (c) Quantity for Mess (Clubs) for 36 JCOs = 202.00 Kg
Providing Polymer modified cement Mortar treatment after epoxy grouting & cleaning and preparing the surface.Applying Polymer cement bond coat and Polymer modified cement Mortar as per manufacturer specification up to 30 mm thick with 8% polymer by weight of cement to fill the all cavities & making protective cover plaster including shuttering ect. complete.
Tentative bifurcation of quanities is as under :- (a) Quantity for 23 Hav & 134 OR Accn = 40.00 Sqm (b) Quantity for 22 Hav & 133 OR Accn = 40.00 Sqm (c) Quantity for Mess (Clubs) for 36 JCOs = 40.00 Sqm
Providing Polymer modified cement Mortar treatment after epoxy grouting & cleaning and preparing the surface.Applying Polymer cement bond coat and Polymer modified cement Mortar as per manufacturer specification up to 15 mm thick with 8% polymer by weight of cement to fill the all cavities & making protective cover plaster including shuttering etc. complete.
Tentative bifurcation of quanities is as under :- (a) Quantity for 23 Hav & 134 OR Accn = 12.00 Sqm (b) Quantity for 22 Hav & 133 OR Accn = 10.00 Sqm (c) Quantity for Mess (Clubs) for 36 JCOs = 12.00 Sqm
NOTES FOR SCHEDULE "A" PART XIII (A&B) :- (i) Unit rates quoted shall include the cost for carrying out the testing of strengthened members by Government institution viz. IIT / NIT / Govt. Engineering College. In case the desired results are not obtained, the treatment shall be carried out again as advised by the manufacturer without any extra cost to the department. (ii) Balance work in respect of structures requiring strengthening measures as stated above shall only be commenced after successful completion of test for acceptability criteria adopted after strengthening of concrete members (ie. after confirmatory structural audit by the contractor from IIT/NIT/Govt Engg college). (iii) All applications and works shall be executed under the close supervision of Structural Consultant/specialist agency as approved by GE and fees payable to approved Structural Consultant/specialist agency shall be deemed to be included in the unit rates quoted. (iv) 25% of quoted amount of Scedule "A" Part XIII(A&B) for repairs/retrofitting works in these three buildings, shall be released only after getting the successful confirmatory structural audit report by the contractor from IIT/NIT/Govt Engg college.
Total amount of Sch ‘A’ Part-XIV (Partially completed DOs in completed/ partially completed work)
United Sales Corporation
SOOD ASSOCIATES PVT LTD
NITYA NAND AND SONS CONTRACTORS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.07 MB