Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
Tender Value
Refer Docs
EMD Value
₹1,000
Closing Date
11 Nov 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Chief Officer
Panchgani Municipal Council, Panchgani, Satara
Maintenance Water Supply Dranage Reparing Work etc For Panchgani Municipal Council
2022_DMA_830266_4
Annual Tender 5
Open Tender
Sanitory Works
Item Rate
365 days
Panchgani Municipal Council
Please refer Tender documents.
2 documents required · 2 mandatory
₹1,000
₹1,000
31 Jan 2023
7 Oct 2022
15 Nov 2022
7 Oct 2022
11 Nov 2022
7 Oct 2022
Amount
Providing and laying in walls/ceilings/floors 15 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.25 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1458, SSR No. 43.01, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 20 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.63 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1459, SSR No. 43.02, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 2.49 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1460, SSR No. 43.03, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 32 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.20 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1461, SSR No. 43.04, BDV 5, Page No. 208)
Providing and laying in walls/ ceilings/floors 40 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 3.68 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1462, SSR No. 43.05, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 5.17 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1463, SSR No. 43.06, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 8.57 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1464, SSR No. 43.07, BDV 5, Page No. 208)
Providing and laying in walls/ceilings/floors 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 12.43 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1465, SSR No. 43.08, BDV 5, Page No. 208)
Providing and laying in trenches 15 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes of 1.48 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1466, SSR No. 43.09, BDV 5, Page No. 209)
Providing and laying in trenches 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1467, SSR No. 43.10, BDV 5, Page No. 209)
Providing and laying in trenches 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 3.01 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1468, SSR No. 43.11, BDV 5, Page No. 209)
Providing and laying in trenches 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 3.89 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1469, SSR No. 43.12, BDV 5, Page No. 209)
Providing and laying in trenches 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 4.49 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1470, SSR No. 43.13, BDV 5, Page No. 209)
Providing and laying in trenches 50 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 6.33 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1471, SSR No. 43.14, BDV 5, Page No. 209)
Providing and laying in trenches 80 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 10.15 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1472, SSR No. 43.15, BDV 5, Page No. 209)
Providing and laying in trenches 100 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 14.74 Kilogram/metre necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1473, SSR No. 43.16, BDV 5, Page No. 209)
Providing and fixing 8 cm rigid PVC Nahani trap including PVC grating ,bend, connecting piece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) (SR. No. 1474, SSR No. 43.17, BDV 23, Page No. 209)
Providing and fixing 15 cm rigid PVC Nahani trap including PVC grating ,bend,connectingpiece of UPVC pipe up to the outside face of wall ,making the good damaged surface and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) (SR. No. 1475, SSR No. 43.18, BDV 24, Page No. 210)
Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 litre enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.(prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1476, SSR No. 43.19, BDV 21, Page No. 210)
Providing and fixing European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall without flushing cistern with flush cock and with water Jet and necessary fittings including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1477, SSR No. 43.20, BDV 21, Page No. 210)
Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1478, SSR No. 43.21, BDV 22, Page No. 210)
Providing and fixing European type Colour glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall without flushing cistern with flush cock and with water Jet and necessary fittings including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1479, SSR No. 43.22, BDV 23, Page No. 210)
Providing and fixing Anglo Indian type white glazed earthenware water closet pan with trap with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall with flushing cistern and necessary fittings including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1480, SSR No. 43.23, BDV 20, Page No. 210)
Providing and fixing high level 10 liter capacity with fittings inlet PVC pipe with stop tap ,brackets for fixing the cistern,32 mm dia. PVC flush pipe with fitting and clamps 20 mm dia. PVC overflow pipe with mosquito proof couplings, galvanised iron chain and pulley painting if ordered to cistern pipe etc. and cutting and making good the damaged wall and testing etc. complete ( Prior approval of sample and brand by Ex. Engr. is necessary before use) (SR. No. 1481, SSR No. 43.24, BDV 22, Page No. 210)
Providing and fixing in position UPVC ultra violet stabilized 110 mm outer diameter cowl dome confirming to I.S.-4985 including making joints with solvent cement etc. complete (SR. No. 1482, SSR No. 43.25, BDV 23, Page No. 210)
Providing and fixing Glass self 125 mm wide and 600 mm long with necessary chromium plated brackets providing T.W.gutties etc. complete (SR. No. 1483, SSR No. 43.26, BDV 23, Page No. 210)
Providing , constructing and fixing 250 mm dia. Inspection chamber made up of UPVC material of thickness 3.5 mm and height of 259 mm with inlet and outlet of 110 mm dia. with 75 mm dia. U Trap, Ultra shaft pipe of Upvc material having height of 470 mm and fixing Ultra 250 mm dia. UPVC cover and frame in 150 mm thick in c.c.1:2:4, having crushed sand bed of 100 mm thick of size 550 mm dia. Including excavation and refilling the sides of chamber by crushed sand cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. (SR. No. 1484, SSR No. 43.27, BDV 23, Page No. 211)
Providing , constructing and fixing 450 mm dia. Inspection chamber made up of Polypropylene / polyethylene material of thickness 3.5 mm and height of 388 mm with 160 or 200 mm main inlet (s) outlet and 110 and / or 160 mm branch inlets, with 450 mm dia. Ultra shaft pipe of HDPE material having height of 460 mm, having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc. complete. (SR. No. 1485, SSR No. 43.28, Bd-V, Page No. 211)
Providing , constructing and fixing 600 mm dia. Inspection chamber made up of Polypropylene / polyethylene material Having 315 mm diameter inlet(s)/outlets and with eccentric reducers as per requirement to connect 160 mm and 200 mm pipes having thickness of 5 mm and 600 mm in height, with inbuilt shaft achieve the invert depth as per site condition of wall thickness of 5 mm having R.C.C. cover and frame fixing in 150 mm thick in c.c.1:2:4, having crushed sand bed of 150 mm thick of size 750 mm dia. Including excavation and refilling the sides of chamber by ?sand crushed cushioning 150 mm thickness, connecting all required UPVC fittings with rubber lubricant etc.complete. (SR. No. 1486, SSR No. 43.29, Bd-V, Page No. 211)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super bib tap with flange including all accessories etc complete (SR. No. 1492, SSR No. 43.35, BDV, Page No. 211)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super Two Way bib tap with flange and extender including all accessories etc complete (SR. No. 1493, SSR No. 43.36, BDV, Page No. 212)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super push button type cock / tap with flange including all accessories etc complete (SR. No. 1494, SSR No. 43.37, BDV, Page No. 212)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super wall sink type tap with flange including all accessories etc complete (SR. No. 1495, SSR No. 43.38, BDV, Page No. 212)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super jet spray with flange 2 in 1 faucet 1.50 metre long including all accessories etc complete (SR. No. 1496, SSR No. 43.35, BDV, Page No. 212)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super right angle stop tap with flange including all accessories etc complete (SR. No. 1497, SSR No. 43.40, BDV, Page No. 212)
Providing and fixing 15 mm diameter PVC Aqua kraft type of approved make super Pillar tap with flange including all accessories etc complete (SR. No. 1498, SSR No. 43.41, BDV, Page No. 212)
Providing and fixing ISI 1729/2002 grade 75 mm dia Cast Iron Waste Water Pipe with lugs necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means by galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of gray oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge. (SR. No. 1499, SSR No. 43.42, BDV, Page No. 212)
Providing and fixing ISI 1729/2002 grade 100 mm dia Cast Iron Soil Pipes With lugs including plug bend necessary fittings such as bends, tees, single junction, double junction, slotted vent, offsets on wall or into the ground including filling joints with cement mortar 1:2 proportion fixing on wall by means of galvanised Mild Steel bracket of 30 x 5 mm plate and 8 mm square rod with Galvanised Iron clamp with washer as per design, drawing and as directed to keep pipe 50 mm away from wall including necessary scaffolding and painting the exposed faces with one coat of red lead oil paint and two coats of white oil paint including removing the existing pipe if necessary and conveying and stacking in PWD Chowky or as directed by Engineer-in-Charge. (SR. No. 1500, SSR No. 43.43, BDV, Page No. 212)
Providing and fixing Wall Mounted European type white glazed earthenware water closet pan with UPVC seat and lid with chromium plated brass hinges and rubber buffers including UPVC and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 mm dia. UPVC flush pipe with fittings and clamps ,20 mm dia.UPVC overflow pipe ,mosquito proof couplings G.I. chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (SR. No. 1501, SSR No. 43.44, BDV, Page No. 212)
Guniting by dry mix process as per IS 9012 ( 1978) to ceiling sofit etc. in C.M. 1:3, 20mm thick under pressure of 2.1Kilogramto 2.8Kilogramper sq.cm including forms, scaffolding,floating the surface, curing for 14 days etc. complete (Excluding reinforcement) (SR. No. 1502, SSR No. 44.01, BDW 2, Page No. 213)
Guniting by dry mix process as per IS 9012 ( 1978) to the vertical surface ( other than column) in C.M. 1:3, 25mm thick under pressure of 2.1Kilogramto 2.8Kilogramper sq.cm.including forms,scaffolding, floating the surface curing for 14 days etc.complete ( excluding reinforcement) (SR. No. 1509, SSR No. 44.08, BDW 2L, Page No. 213)
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S.Angles ( 50mm x 50mm x 6mm) at 2.5 Metres, Center to center including excavating pits for foundqtion, fixing post in cement cocnrete 1:4:8 of size 45 x 45 x 45 cm fastening the wire and painting the M.S.Angles with one coat of red lead primer and two coats of painting etc.complete. (SR. No. 1510, SSR No. 44.09, BDW 3, Page No. 213)
Providing and fixing mild steel grill gate with angle iron frame 65mm x 65mm x 10mm with iron bars at 150mm C/C and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram/Smt. (SR. No. 1511, SSR No. 44.10, BDW 6, Page No. 213)
Providing and fixing 90 cm x 60 cm Marble plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete (SR. No. 1512, SSR No. 44.11, BDW 7, Page No. 213)
Providing and fixing 90 cm x 60 cm Granite plate engraving 10 cm. height letter, figures including painting the lefters/figures with approved colour and shade complete (SR. No. 1513, SSR No. 44.12, BDW 7, Page No. 213)
Providing and erecting 1.2 meter high wire fencing with five rows of barbed wire supported on mild steel angle ( 50 x 50x 6mm) post at 2.5 m c/c including excavation of pits of foundation concrete fixing the posts in ( 1:4:8) cement concrete block of 45x45x45 cm and fastening the Wires and painting the angles with one coat with red lead primer and two coats of oil painting etc.complete (SR. No. 1514, SSR No. 44.13, BDW, Page No. 214)
Providing and fixing rain tattis with bamboos and karve grass with 75 mm thick grass and removing the same after rain is over (size of bamboos 50 mm to 75mm dia and 3 M to 3.5 M long) (SR. No. 1515, SSR No. 44.14, BDW, Page No. 214)
Providing and fixing grass chhapper (roof) with necessary bamboos and karve frame with 75mm. thick grass etc.removing the same after rain is over (size of bamboos 50mm to 75mm dia and 3 M to 3.5M long) (SR. No. 1516, SSR No. 44.15, BDW, Page No. 214)
Providing and fixing grass chhapper (roof) with necessary bamboos and karve frame with 75mm. thick grass etc.removing the same after rain is over (size of bamboos 25mm dia and 3 M to 3.5 M long) (SR. No. 1517, SSR No. 44.16, BDW, Page No. 214)
Providing and fixing Bamboo Matting screen for partition with bamboo sticks (SR. No. 1518, SSR No. 44.17, BDW, Page No. 214)
Providing and fixing lioghtening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25mm dia. 1.2 mm thick with multiple points head 1.2 mt. long ( Heavy Duty) welded or clamped to G.I. pipe pole B grade 50 mm diaof requiired length with M.S. round bnase plate 25 Cm diam and 10mm thick at bottom embeded in cement concrete 1:3:6 dfoundation of size 45 cm diam x 45 cm Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 cms with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40Kilogramcharcoal and salt with altemate layers of charcoal and salt and G.I.pipe 40mm dia 2 meter length burried in earthe upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item. (SR. No. 1519, SSR No. 44.18, BDW, Page No. 214)
Providing and fixing copper strip 25mm wide and 3mm thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthinf pits is not considered in this item (SR. No. 1520, SSR No. 44.19, BDW, Page No. 214)
Providing and fixing in position alluminium strips of size 50mm x 3mm for nosing the steps including fixing with screws and raval plugs, bending and cutting to the required shape and size, finishing with paint, necessary mortar bedding of 1:3 cement mortar to get exact line and level including watering and curing etc.complete (SR. No. 1521, SSR No. 44.10, BDW, Page No. 214)
Providing and fixing crimped with G.I. mesh and size 20 mm x 20mm 10 guage to iron angle frame including welding crimp mesh to angle frame and steel flat, fixing the frame in its original position and oil painting etc.complete ( excluding cost of structural steel) (SR. No. 1522, SSR No. 44.21, BDW, Page No. 214)
Providig and fixing wleded mesh fabric for guniting of mesh size 75 mm x 75mm and 10 guage thick including scaffolding etc.complete (SR. No. 1523, SSR No. 44.23, BDW, Page No. 214)
Providing and fixing welded mesh fabric for guniting of mesh size 150mm x 150mm and 10 guage i.e. 3.25mm thick including scaffolding etc.complete (SR. No. 1523, SSR No. 44.24, BDW, Page No. 214)
Removing double country tiled roof with ridge and with battens and stacking the materials as directed with all leads and lifts, complete including removing wood work below etc. complete (SR. No. 1525, SSR No. 46.01, BDW 8-2, Page No. 215)
Removing planking from roof or ceiling and stacking them sa directed with all leads and lifts etc. complete (SR. No. 1526, SSR No. 46.02, BDW 8-4, Page No. 215)
Removing Queen Post truss from roof and stacking the materials as directed with all leads and lifts etc. complets (SR. No. 1527, SSR No. 46.03, BDW 8-2A, Page No. 215)
Removing King Post truss from roof and stacking the materials as directed with all leads and lifts etc. complets (SR. No. 1528, SSR No. 46.04, BDW 8-5B, Page No. 215)
Removing other type truss below 5 metres span from roof and stacking the materials as directed with all leads and lifts etc. complets (SR. No. 1529, SSR No. 46.05, BDW 8-5C, Page No. 215)
Dismantling flat wooden or A.C. Sheet ceiling with frame work including stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1530, SSR No. 46.06, BDW 8-8, Page No. 215)
Removing cloth ceiling including frame work and stacking the materials as ditected with all leads, lifts etc. complete (SR. No. 1531, SSR No. 46.07, BDW 8-9, Page No. 215)
Dismantling brick masonry in Mud and stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1532, SSR No. 46.08, BDW 8, Page No. 215)
Dismantling brick masonry in lime or cement mortar and stacking the materils as directed with all leads, lifts etc. (SR. No. 1533, SSR No. 46.09, BDW 8, Page No. 215)
Dismantling stone masonry in Mud including stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1534, SSR No. 46.10, BDW 8, Page No. 215)
Dismantling stone masonry in lime or cement mortar including stacking the materils as directed with all leads, lifts etc. (SR. No. 1535, SSR No. 46.11, BDW 8, Page No. 215)
Removing lime or lean cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (SR. No. 1536, SSR No. 46.12, BDW 8, Page No. 215)
Removing rich mix cement concrete including stacking the spoils as directed with all leads, lifts etc, complete. (SR. No. 1537, SSR No. 46.13, BDW 8, Page No. 215)
Removing brick bat coba including stacking the spoils as directed with all leads, lifts etc, complete. (SR. No. 1538, SSR No. 46.14, BDW 8, Page No. 215)
Removing doors and windows with frames and stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1539, SSR No. 46.15, BDW 8, Page No. 215)
Removing ventilators and small windows with frame and stacking the materials with all leads, lifts etc. complete. (SR. No. 1540, SSR No. 46.16, BDW 8, Page No. 215)
Removing wooden or A.C. partition including frame work and stack-ing the materials as with all leads, lifts etc. complete. (SR. No. 1541, SSR No. 46.17, BDW 8, Page No. 215)
Removing teak wood trellies work with frame including stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1542, SSR No. 46.18, BDW 8, Page No. 215)
Removing cement tiles, or marble or polished shahabad floor or dado without bed concrete including stacking the materials as directed with all leads, lifts etc. complete (SR. No. 1543, SSR No. 46.18, BDW 8, Page No. 215)
Dismantling wooden floor including beams and joists, stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1544, SSR No. 46.21, BDW 8, Page No. 216)
Removing mud plaster including disposing of the spoils as directed with all leads, lifts etc, complete. (SR. No. 1545, SSR No. 46.23, BDW 8, Page No. 216)
Removing wire fencing with wooden post and stacking the material with all leads, lifts etc. complete. (SR. No. 1546, SSR No. 46.24, BDW 8, Page No. 216)
Removing wire fencing with iron/ C.C. fencing post and stacking the materials as directed with all leads, lifts etc. complete. (SR. No. 1547, SSR No. 46.25, BDW 8, Page No. 216)
Removing iron pipe raling having wooden R.C.C. or C.C. or iron post and stacking the materials as directed etc. complete. (SR. No. 1548, SSR No. 46.26, BDW 8, Page No. 216)
Removing earthen, stonewate pipe and stacking them as directed with all leads, lifts etc. complete. (SR. No. 1549, SSR No. 46.27, BDW 8, Page No. 216)
Removing cast iron or wrought iron or A.C. pipe and stacking them as directed with all leads, lifts etc. complete. (SR. No. 1550, SSR No. 46.28, BDW 8, Page No. 216)
Dismantling the R.C.C. Work 1:2:4 and sorting out the materials such as steel etc. as directed and stacking them within the specified lead as directed etc. complete. (SR. No. 1551, SSR No. 46.29, BDW 8, Page No. 216)
Removing Np-2 and Np-3 class pipes including stacking at road side as directed by the Engineer in charge. Upto 900mm dia. etc complete. (SR. No. 1552, SSR No. 46.30, BDW 8, Page No. 216)
Removing Np-2 and Np-3 class pipes including stacking at road side as directed by the Engineer in charge. Upto 900mm dia and above. etc complete. (SR. No. 1553, SSR No. 46.31, BDW 8, Page No. 216)
Removing single country tiled roof with battens and stacking the materials as directed with all leads and lifts etc. complete. (SR. No. 1554, SSR No. 46.32, BDW 8, Page No. 216)
Removing battens from roof and stacking them as directed with all leads and lifts etc. complete. (SR. No. 1555, SSR No. 46.33, BDW 8, Page No. 216)
Removing matting from roof and stacking as directed with all leads and lifts etc. complete. (SR. No. 1556, SSR No. 46.34, BDW 8, Page No. 216)
Removing purlins from roof including stacking as directed with all leads , lifts etc. complete. (SR. No. 1557, SSR No. 46.35, BDW 8, Page No. 216)
Removing rafters from roof including the materials as directed with all leads , lifts etc. complete. (SR. No. 1558, SSR No. 46.36, BDW 8, Page No. 216)
Removing cloth partition with frame work and stacking the materials as directed with all leads , lifts etc. complete. (SR. No. 1559, SSR No. 46.37, BDW 8, Page No. 216)
Providing and fixing Jute Kantan (Tarat) screen to the scaffold-ing for external guniting as directed including removing the same after the work is over etc. complete. (SR. No. 1560, SSR No. 46.38, BDW, Page No. 216)
Providing and erecting chain link fencing 1.6 M. height with G.I. chain link of size 50 x 50 mm, 8 gauge thick and fixed 75 mm above ground level on vertical M.S. Angles of 40 x 40 x 6 mm size, includind excavating pits for foundation and embedded in C.C. block of 1:4:8 mix of size 450 x 450 x 670 mm. at 1.75 M. c/c with iron bar 16mm dia as hold fast including welding link with angle frame at 30 cm c/c with nuts and bolts and horizontal M.S. Angles at top and bottom of 25 x 25 x 5 mm size and vertical M.S. flat 35 x 5 mm and 25 x 5 mm horizontal including cross support of 40 x 40 x 6 mm angles both side at every corner or bend embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 mm including 3 coats of oil painting etc. complete. (SR. No. 1561, SSR No. 46.39, BDW, Page No. 217)
Removing urinal pans or wash hand basins with frame including disconnecting the sanitary and water supply connections, removing the same carefully and stacking the serviceable materials as and where directed including throwing the unserviceable materials outside etc complete (SR. No. 1562, SSR No. 46.30, BDW, Page No. 217)
Removing W.C. pans including disconnecting the sanitary and water supply connections, removing and breaking flooring and bed con-crete around pan removing the same carefully and stacking the serviceable materials as adn where directed including throwing the unserviceable materiasls out side etc. carefully and throwing out the refusal outside etc. complete. (SR. No. 1563, SSR No. 46.41, BDW, Page No. 217)
Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in- charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. (SR. No. 1564, SSR No. 46.42, BDW, Page No. 217)
Removing Manglore tiled roof and ridge tiles with battens, ridge and barge boards, eaves 8 A boards etc and sacking the materials as directed with all leads and lifts complete. Including removing wood work below etc. complete. (SR. No. 1565, SSR No. 46.43, BDW, Page No. 217)
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on M.S. Angles (50 mm x 50 mm x 6 mm) at 2.5 metres centre to centre including excavating pits for foundation, fixing posts in cement concrete of size 45 x 45 x 45 cm, fastening the wire and painting the M.S. Angles with one coat of red lead primer and two coats of painting etc. complete. (SR. No. 1566, SSR No. 46.44, BDW, Page No. 217)
Providing and erecting 1.5 metre high wire fencing with seven rows of barbed wire supported on wooden post of specified size at 2.5 M C/C including excavating pits for foundation, fixing post in cement concrete 1:4:8 block of concrete of size 45 x 45 x 45 cm fastening the wire and coal tarring wooden post in two coats etc. complete. (SR. No. 1567, SSR No. 46.45, BDW, Page No. 217)
Replacement of damaged alluminium Butt Hinges of 125 mm of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer incharge. (SR. No. 1568, SSR No. 46.46, BDW, Page No. 217)
Replacement of damaged Mortise Lock of approved quality and make to door shutter including Removing and Refixing with Necessary screw, making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-chareg. (SR. No. 1569, SSR No. 46.47, BDW, Page No. 218)
Replacement of damaged Aldrop 300 mm Chromium plated of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. (SR. No. 1570, SSR No. 46.48, BDW, Page No. 218)
Replacement of damaged Aldrop 300 mm Iron Oxidised of approved quality and make to door shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. (SR. No. 1571, SSR No. 46.49, BDW, Page No. 218)
Replacement of damaged Tower Bolt 300 mm Chromium plated of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. (SR. No. 1572, SSR No. 46.50, BDW, Page No. 218)
Replacement of damaged Alluminium Handle 125 mm of approved quality and make to door/window shutter including removing existing the same in original position making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. (SR. No. 1573, SSR No. 46.51, BDW, Page No. 218)
Replacement of damaged Lock of approved quality and make to cupboard and doorwer including Removing and Refixing with necessary screw, making proper adjustment for smooth operation etc. complete as per sample approved by Engineer in-charge. (SR. No. 1574, SSR No. 46.52, BDW, Page No. 218)
Removing chockes and leakages from down take G.I/CI/PVC pipe line on walls floor level by using zoola / scaffolding and rectify the same for functioning with all lifts etc. complete. (SR. No. 1575, SSR No. 46.53, BDW, Page No. 218)
Manualy clearing the chockes from under ground drainage line including Inspection chambers with the help of required tools for propre functioning line chamber to chamber etc. complete. (SR. No. 1576, SSR No. 46.54, BDW, Page No. 218)
Manualy clearing by removeing the chockes from Nahni Trap, Gully Trap, Wash basin unit, Sink and WC with the help of required tools for proper functioning the same etc. complete. (SR. No. 1577, SSR No. 46.55, BDW, Page No. 218)
Filling tiles joint portion of flooring and dado filling with white cement by removing existing loose morter/ cement slurry from joint with tools and finish with washing cleaning and curing etc. complete. (SR. No. 1578, SSR No. 46.56, BDW, Page No. 218)
Providing and fixing 6 mm thick commercial plywood with jungle wood frame work of 50 x 35 mm size at 60 cm on both ways for closing the window portion/openings for protection from falling debris, dust etc. including cutting, fixing with nails and removing after the same after completion of the work. (To be used after approval of Superintending Engineer) (SR. No. 1579, SSR No. 46.57, BDW, Page No. 218)
Removal of plants / ficus grown by pulling out root system embedded in masnory, cutting stem and application of high/gur/lime formulation as specified by the Architect or other patented chemical biocide treatment such as biocide 'Glycel' (iso proplamine salt of glyphosate) or other chemical as specified by the Engineer in charge etc. complete. (SR. No. 1580, SSR No. 46.58, BDW, Page No. 218)
Lowering down the debris obtained from breaking and removing the cement plaster / burnt brick masonry of the first floor by any means without causing dust nuisance and damage to structure, stacking the same as and where directed including cleaning the site complete. (SR. No. 1581, SSR No. 46.59, BDW, Page No. 218)
Providing and laying cast iron pipes of B class of 80mm diameter with sockets and spigot ends/ flanges and cast centrifugally / vertically including specials, laying pipes and back filling the trench complete including excavation. (SR. No. 1300, SSR No. 41.01, BDV 1, Page No. 194)
Providing and laying cast iron pipes of B class of 100mm diameter with sockets and spigot ends/ flanges and cast centrifugally/vertically including specials, laying pipes and back filling the trench complete including excavation. (SR. No. 1301, SSR No. 41.02, BDV 1A, Page No. 194)
Providing and laying cast iron pipes of B class of 150mm diameter with sockets and spiget ends/ flanges and cast centrifugally/ vertically including specials, laying pipes and back filling the trench complete including excavation. (SR. No. 1302, SSR No. 41.03, BDV 1B, Page No. 194)
Providing and making lead joints for 80mm diameter cast iron pipe line including lead and testing. (SR. No. 1303, SSR No. 41.04, BDV 2, Page No. 194)
Providing and making lead joints for 100mm diameter cast iron pipes line including lead and testing. (SR. No. 1304, SSR No. 41.05, BDV 2 A, Page No. 194)
Providing and making lead joints for 150mm diameter cast iron pipe line including lead and testing (SR. No. 1305, SSR No. 41.06, BDV 2B, Page No. 194)
Providing and making flanged connection for the 80mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete. (SR. No. 1306, SSR No. 41.07, BDV 3, Page No. 194)
Providing and making flanged connection for the 100mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete. (SR. No. 1307, SSR No. 41.08, BDV 3A, Page No. 194)
Providing and making flanged connection for the 150mm diameter cast iron pipe line including painting rubber insertion, nuts and bolts etc. complete. (SR. No. 1308, SSR No. 41.09, BDV 3B, Page No. 194)
Providing and fixing on walls/ ceiling/ floors, 15 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 1.48 Kilogram/metre with necessary fittings. remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1309, SSR No. 41.10, BDV 5, Page No. 194)
Providing and fixing on walls/ ceiling/ floors 20 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes of 1.93 Kilogram/meter with necessary fitting remaking good the demolished portion and applying primer of anti-corrosive oil paint, 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1310, SSR No. 41.11, BDV 5, Page No. 194)
Providing and fixing on walls/ ceiling/ floors, 25 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.01 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1311, SSR No. 41.12, BDV 5, Page No. 194)
Providing and fixing on walls/ ceiling/ floors, 32 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 3.89 Kilogram/meter with necessary fittings . remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1312, SSR No. 41.13, BDV 5, Page No. 195)
Providing and fixing on walls/ ceiling/ floors, 40 mm dia. heavy grade having embossed as ISI Mark galvanised iron pipes weight of 4.49 Kilogram/meter with necessary fittings and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1313, SSR No. 41.14, BDV 5, Page No. 195)
Providing and fixing on walls/ ceiling/ floors, 50 mm dia heavy grade having embossed as ISI Mark galvanised iron pipes weight of 6.33 Kilogram/meter with necessary fittings.and remaking good the demolished portion and primer of anti corrossive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1314, SSR No. 41.15, BDV 5, Page No. 195)
Providing and fixing on walls/ ceiling/ floors, 80 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 10.15 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1315, SSR No. 41.16, BDV 5, Page No. 195)
Providing and fixing on walls/ ceiling/ floors, 100 mm dia.heavy grade having embossed as ISI Mark galvanised iron pipes weight of 14.74 Kilogram/meter with necessary fittings. and remaking good the demolished portion and applying primer of anti-corrosive oil paint 2 coats Including necessary scaffolding and removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1316, SSR No. 41.17, BDV 5, Page No. 195)
Providing and laying in trenches 15 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes of 1.25 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1317, SSR No. 41.18, BDV 5, Page No. 195)
Providing and laying in trenches 20 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 1.63 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1318, SSR No. 41.19, BDV 5, Page No. 195)
Providing and laying in trenches 25 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 2.49 Kilogram/meter necessary fitting remaking good the ?demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.(SR. No. 1319, SSR No. 41.20, BDV 5, Page No. 195)
Providing and laying in trenches 32 mm dia.medium grade having embossed as ISI Mark galvanised iron pipes ?of 3.20 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1320, SSR No. 41.21, BDV 5, Page No. 195)
Providing and laying in trenches 40 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 3.68 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1321, SSR No. 41.22, BDV 5, Page No. 196)
Providing and laying in trenches 50 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 5.17 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1322, SSR No. 41.23, BDV 5, Page No. 196)
Providing and laying in trenches 80 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 8.57 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint, 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1323, SSR No. 41.24, BDV 5, Page No. 196)
Providing and laying in trenches 100 mm dia. medium grade having embossed as ISI Mark galvanised iron pipes ?of 12.43 Kilogram/meter necessary fitting remaking good the demolished portion with filling trenches and with primer of anti-corrosive oil paint , 2 coats Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1324, SSR No. 41.25, BDV 5, Page No. 196)
Providing and fixing 15mm diameter water meter with non-return valve including strainer, sockets/ union nut including water meter box making locking arrangement and lock. [Without chamber]. (SR. No. 1325, SSR No. 41.26, BDV 7, Page No. 196)
Providing and fixing 20mm diameter water meter with non-return valve including strainer, sockets/ union nut including water meter box making locking arrangement and lock. (without chamber).(SR. No. 1326, SSR No. 41.27, BDV 7, Page No. 196)
Providing and fixing 25mm diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber]. (SR. No. 1327, SSR No. 41.28, BDV 7, Page No. 196)
Providing and fixing 40mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangements and lock. [Withoutchamber]. (SR. No. 1328, SSR No. 41.29, BDV 7, Page No. 196)
Providing and fixing 50mm diameter water meter with non-return valve including strainer,sockets/ union nut and including water meter box making locking arrangement and lock. [without chamber] (SR. No. 1329, SSR No. 41.30, BDV 7, Page No. 196)
Providing and fixing 15 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. (SR. No. 1332, SSR No. 41.40, BDV 8, Page No. 196)
Providing and fixing 20 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. (SR. No. 1333, SSR No. 41.41, BDV 8, Page No. 197)
Providing and fixing 25 mm dia. screw down bib/ stop tap of brass including necessary socket union nut complete. (SR. No. 1334, SSR No. 41.42, BDV 8, Page No. 197)
Providing and fixing screw down 15 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete (SR. No. 1335, SSR No. 41.43, BDV 9, Page No. 197)
Providing and fixing screw down for 20 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (SR. No. 1336, SSR No. 41.44, BDV 9, Page No. 197)
Providing and fixing screw down for 25 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (SR. No. 1337, SSR No. 41.45, BDV 9, Page No. 197)
Providing and fixing screw down for 32 mm dia. wheeled stop tap of brass including necessary sockets/union nut complete. (SR. No. 1338, SSR No. 41.46, BDV 9, Page No. 197)
Providing and fixing 15mm diameter concussion push button type brass/gun metal self- closing tap including necessary socket complete. (SR. No. 1344, SSR No. 41.52, BDV 14, Page No. 197)
Providing and fixing 25mm diameter concussion push button type brass/gun metal self- closing tap including necessary socket complete (SR. No. 1345, SSR No. 41.53, BDV 14, Page No. 197)
Providing and fixing push cock (Self closing tap) symet type of 15 mm dia. including necessary socket, testing etc. complete. (SR. No. 1346, SSR No. 41.54, BDV, Page No. 197)
Providing and fixing push cock (Self closing tap) symet type of 20 mm dia. including necessary socket, testing etc. complete. (SR. No. 1347, SSR No. 41.55, BDV, Page No. 197)
Providing and fixing 45 cm wide mild steel ladder of 40mm x 6 mm mild steel flat stringers and steps of 18 mm dia. mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60cm x 30cm x 30cm and painting the ladder complete. (Anti Corossive Paint) (SR. No. 1348, SSR No. 41.56, BDV 19, Page No. 198)
Providing and fixing White Glazed Earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall (SR. No. 1349, SSR No. 41.57, BDV 23, Page No. 198)
Providing and fixing White Glazed Earthenware Squatting plate (Ladies Urinal) with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 mm dia. P.V.C flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connectionup to the outside face of the wall (SR. No. 1350, SSR No. 41.58, BDV 23, Page No. 198)
Providing and fixing coloured glazed earthenware full stall type Urinal with P.V.C. flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap brackets for fixing the cistern 32mm dia. P.V.C. flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap soil pipe connection up to the outside face of the wall. (SR. No. 1351, SSR No. 41.59, BDV 23, Page No. 198)
Providing and fixing white glazed earthenware lipped flat back/corner type Urinal with PVC 5 liters flushing cistern with fittings, inlet pipe with stop tap, brackets for fixing the cistern, 32 mm diameter P.V.C. flush pipe with fitting including lead soil pipe, lead trap and soil pipe connection up to the outside face of wall. (SR. No. 1352, SSR No. 41.60, BDV 26, Page No. 198)
Providing and fixing coloured glazed earthenware lipped flat back/corner type urinal with PVC 5 liters flushing cistern with fittings,capacity with fittings, inlet pipe and stop tap, brackets for fixing the cistern, P.V.C. flush pipe with fittings including lead soil pipe, lead trap and soil pipe connection up to the outside face of the wall.(SR. No. 1353, SSR No. 41.61, BDV 27, Page No. 198)
Providing and fixing white glazed earthenware Wash Hand Basin of 55cm. x 40 cm. size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connections including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. (SR. No. 1355, SSR No. 41.63, BDV 30, Page No. 198)
Providing and fixing white glazed earthenware Wash Hand Basin of 45cm x 30cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. (SR. No. 1356, SSR No. 41.64, BDV 30, Page No. 198)
Providing and fixing white glazed earthenware Wash Hand Basin of 63cm x 45cm size including Bib cock stop tap brass heavy 15mm, brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. (SR. No. 1357, SSR No. 41.65, BDV 30, Page No. 198)
Providing and fixing coloured glazed earthenware Wash Hand Basin of 55cm x 40 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. (SR. No. 1358, SSR No. 41.66, BDV 30, Page No. 198)
Providing and fixing coloured glazed earthenware Wash Hand Basin of 45 cm x 30 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. Making good the damaged surface, testing etc. complete. (SR. No. 1359, SSR No. 41.67, BDV 30, Page No. 199)
Providing and fixing White glazed with bottle trap earthenware Wash Hand Basin of 55x40 cm size including cold water piller taps, brackets, rubber plugs and brass chain, stop tap, chromium plate bottle trap and necessary pipe connections including UPAC waste pipe and trap upto the outside face of the wall, making good the damaged surface, testing etc. complete. (SR. No. 1360, SSR No. 41.69, BDV 23, Page No. 199)
Providing and fixing coloured glazed earthenware Wash Hand Basin of 63 cm x 45 cm size including cold water pillar tap/cold and hot water pillar tap brackets, rubber plugs and brass chain, stop tap and necessary pipe connection including P.V.C. waste pipe and trap up to the outside face of the wall. (SR. No. 1363, SSR No. 41.74, BDV 30, Page No. 199)
Providing and fixing white glazed earthenware sink 600mm x 200mm x 450mm including all connection of the G.I. supply and P.V.C. waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. (SR. No. 1364, SSR No. 41.75, BDV 31, Page No. 199)
Providing and fixing white glazed earthenware sink 450mm x 200mm x 300mm including all connection of the G.I. supply and lead waste pipes up to the outside face of the wall, cold water chromium plated screw down bib tap, rolled steel or C.I. brackets, rubber plug with chain and stop tap complete. (SR. No. 1365, SSR No. 41.76, BDV 31, Page No. 199)
Providing and fixing Autoclosing pillar cock of pressmatic tap of approved make or equivalent including all fixtures, fittings etc. complete. (SR. No. 1363, SSR No. 41.74, BDV 30, Page No. 199)
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 mm x 450 mm size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 mm thick supports with kadappah top 35 to 40 mm thick and polished granite 16 to 20 mm top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 cm height and top granite of 75 x 40 cm including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (Platform top size 5.00 m x 0.60 m and height is 0.75 m) (SR. No. 1367, SSR No. 41.78, BDV, Page No. 199)
Providing and fixing 8 cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. (SR. No. 1368, SSR No. 41.79, BDV 32, Page No. 199)
Providing and fixing 10cm C.I. Nahani Trap including C.I. grating bend and piece of C.I. pipe upto the outside face of the wall complete. (SR. No. 1369, SSR No. 41.80, BDV 32, Page No. 199)
Providing and laying concrete pipes of I.S.NP. class of 100mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (SR. No. 1375, SSR No. 42.06, BDV 41, Page No. 200)
Providing and laying concrete pipes of I.S.NP. class of 150mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (SR. No. 1376, SSR No. 42.07, BDV 41, Page No. 200)
Providing and laying concrete pipes of I.S.NP. class of 225mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (SR. No. 1377, SSR No. 42.08, BDV 41, Page No. 200)
Providing and laying concrete pipes of I.S.NP. class of 300mm diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete. (SR. No. 1378, SSR No. 42.09, BDV 41, Page No. 200)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight C. I. cover of 75Kilogramwith lid and frame fixed in cement concrete. (SR. No. 1380, SSR No. 42.10, BDV 43, Page No. 200)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and C.I. lid cover of 75Kilogramwith lid and frame fixed in cement concrete. (SR. No. 1380, SSR No. 42.11, BDV 43, Page No. 200)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. (SR. No. 1381, SSR No. 42.12, BDV 43, Page No. 200)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm x 90cm including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round G.S.W.pipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with R.C.C. Cover medium duty 140Kilogramwith frame etc complete. (SR. No. 1382, SSR No. 42.13, BDV 43, Page No. 200)
Providing and constructing Brick Masonry inspection Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, with C.I. lead cover of 75Kilogramwith frame fixed in cement concrete. (SR. No. 1383, SSR No. 42.14, BDV 44, Page No. 201)
Providing and constructing Brick Masonry inspection trap Chamber 90cm x 45cm including 1:4:8 C.C foundation, 1:2:4 C.C.channels/half round glazed stoneware pipe channel, salt glazed stone-ware intercepting trap with rodding pipe set in 1:4:8 cement concrete block, brick masonry plastering inside and Outside, fixed in cement concrete with R.C.C. Cover medium duty 140 Kilogram. etc complete (SR. No. 1384, SSR No. 42.15, BDV 44, Page No. 201)
Providing and constructing Brick Masonry Inspection Chamber 60cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight 75 mm thick R.C.C. cover medium duty 100Kilogrametc. complete. (SR. No. 1385, SSR No. 42.16, BDV , Page No. 201)
Providing and constructing Brick Masonry Inspection Chamber 90cm x 45cm With R.C.C. raft in B.C. soil area including cost of reinforcement, 1:2:4 cement concrete channels half round G.S.W. pipes, Brick Masonry, plastering from inside and airtight with 75 mm thick R.C.C. cover medium duty 140Kilogrametc. complete. (SR. No. 1386, SSR No. 42.17, BDV, Page No. 201)
Providing and fixing hume pipe septic tank 900mm diameter with vent pipe and cap including necessary (including excavation and laying) (SR. No. 1387, SSR No. 42.18, BDV 45, Page No. 201)
Providing soak pit of size 120cm x 120cm x 120cm including excavating and filling with brick-bats. (SR. No. 1387, SSR No. 42.18, BDV 45, Page No. 201)
Providing and fixing 450mm x 550mm size superior type Belgium mirror with 16mm dia. nickel plated towel rod etc. complete. (SR. No. 1389, SSR No. 42.20, BDV, Page No. 201)
Providing, laying and fixing P.V.C. pipe of 15mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1390, SSR No. 42.21, BDV 60, Page No. 201)
Providing, laying and fixing P.V.C. pipe of 20mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1391, SSR No. 42.22, BDV 60, Page No. 201)
Providing, laying and fixing P.V.C. pipe of 25mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1392, SSR No. 42.23, BDV 60, Page No. 201)
Providing, laying and fixing P.V.C. pipe of 32mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1393, SSR No. 42.24, BDV 60, Page No. 201)
Providing, laying and fixing P.V.C. pipe of 40mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1394, SSR No. 42.25, BDV 60, Page No. 202)
Providing, laying and fixing P.V.C. pipe of 50mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1395, SSR No. 42.26, BDV 60, Page No. 202)
Providing, laying and fixing P.V.C. pipe of 75mm dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1396, SSR No. 42.27, BDV 60, Page No. 202)
Providing, laying and fixing P.V.C. pipe of 110 mm. dia. with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1397, SSR No. 42.28, BDV 60, Page No. 202)
Providing and fixing partition with kadappa stone of all sizes and 25 mm thick polished on both side and edges to original including fixing in position in cement mortor 1:4 curing polish- ing, cleaning etc complete. (SR. No. 1398, SSR No. 42.29, BDV, Page No. 202)
Providing and fixing Orissa type white glazed earthenware 575 mm water closet pan including S trap with earthenware foot rests, cast iron soil and vent pipe upto outside face of the wall 1:2:4 brick bat lime concrete bedding without flushing tank and its accessories etc. complete. (SR. No. 1399, SSR No. 42.30, BDV, Page No. 202)
Providing and fixing chromium plated towel rod 16 mm dia and 75 cm. in length including all accessories complete. (SR. No. 1400, SSR No. 42.31, BDV, Page No. 202)
Providing and Fixing half turn 25 mm dia gun metal flushing cock including all accessories etc. complete. (SR. No. 1401, SSR No. 42.32, BDV, Page No. 202)
Providing and fixing 1st class white glazed earthenware Orissa Type W.C. Pan 580 mm dia including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter P.V.C. flushing cistern with all necessary pipe connection etc. complete. (SR. No. 1402, SSR No. 42.33, BDV, Page No. 202)
Providing and fixing European type white glazed earthenware coupled closet symphonic trap with symphonic low level white glazed 10 litres cistern with black backlite seat with all necessary pipe connection etc. complete. (SR. No. 1403, SSR No. 42.34, BDV, Page No. 202)
Providing and fixing orissa type colour glazed earthenware 625 x 450 mm. w.c. pan including trap, C.I. soil and vent pipe upto the out side face of wall including 100 mm. dia. C.I. plug, bend, 15mm. thick 10 litre PVC flushing cistern with all necessary pipe connection etc. complete. (SR. No. 1404, SSR No. 42.35, BDV, Page No. 202)
Providing and fixing 40 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (SR. No. 1405, SSR No. 42.36, BDV, Page No. 202)
Providing and fixing 15 mm. dia Ball cock medium type with PVC float including sockets and necessary fittings and tested as per municipal requirement etc. complete. (SR. No. 1406, SSR No. 42.37, BDV, Page No. 202)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. i)Tank capacity up to 2,000 litre. (SR. No. 1407, SSR No. 42.38, BDV, Page No. 203)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. ii) Tank capacity up to 2,001 to 5000 litre. (SR. No. 1408, SSR No. 42.39, BDV, Page No. 203)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. iii) Tank capacity up to 5,001 to 7000 litre. (SR. No. 1409, SSR No. 42.40, BDV, Page No. 203)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. iv) Tank capacity up to 7,001 to 10000 litre. (SR. No. 1410, SSR No. 42.41, BDV, Page No. 203)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. v) Tank capacity upto 10,001 to 15,000 litre. (SR. No. 1411, SSR No. 42.42, BDV, Page No. 203)
Cleaning elevated water storage Reservoir within a given period, by using bleaching powder at the rate of 14 gm/sq.m .washing thrice potassium permanganate at the rate of 2.50 gm/sq.m. finally, cleaning washing by using nylon brush, coir string and duster, bailing out water etc. complete. vi) Tank capacity upto 15,001 to 20,000 litre. (SR. No. 1412, SSR No. 42.43, BDV, Page No. 203)
Providing and fixing 75 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete (SR. No. 1420, SSR No. 42.51, BDV, Page No. 204)
Providing and fixing 100 mm dia stabiliser pipe/ P.V.C. soil vent/waste pipe and with necessary fixtures and fitting such as bends, tees, single junctions, slotted vent, clamps etc. complete. (SR. No. 1421, SSR No. 42.52, BDV, Page No. 204)
Providing and fixing H.D.P container one piece moulded water tank made out of high density polythyler and built corrugated inclusive of delivery up to destination hoisting and fixing of accessories such as inlet,outlet overflow pipe inclusive of all tanks capacity between 200 to 1000 liters (SR. No. 1422, SSR No. 42.53, BDV, Page No. 204)
Providing and fixing H.D.P container one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (SR. No. 1423, SSR No. 42.54, BDV, Page No. 204)
Providing and fixing on walls/ ceiling/ floor 15 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1424, SSR No. 42.55, BDV, Page No. 204)
Providing and fixing on walls/ceiling/floor 20 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1425, SSR No. 42.56, BDV 5, Page No. 204)
Providing and fixing on walls/ ceiling/ floor 25 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1426, SSR No. 42.57, BDV 5, Page No. 204)
Providing and fixing on walls/ ceiling/ floor 32 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1427, SSR No. 42.58, BDV 5, Page No. 204)
Providing and fixing on walls /ceiling/ floor 40 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1428, SSR No. 42.59, BDV 5, Page No. 204)
Providing and fixing on walls/ ceiling/ floor 50 mm dia. CPVC pipe with necessary fittings, remaking good the demolished portion etc. complete. (SR. No. 1429, SSR No. 42.60, BDV 5, Page No. 204)
Providing and laying in trenches 15 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1430, SSR No. 42.61, BDV 5, Page No. 205)
Providing and laying in trenches 20 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1431, SSR No. 42.62, BDV 5, Page No. 205)
Providing and laying in trenches 25 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1432, SSR No. 42.63, BDV 5, Page No. 205)
Providing and laying in trenches 32 mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1433, SSR No. 42.64, BDV 5, Page No. 205)
Providing and laying in trenches 40mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1434, SSR No. 42.65, BDV 5, Page No. 205)
Providing and laying in trenches 50mm dai. CPVC pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (SR. No. 1435, SSR No. 42.66, BDV 5, Page No. 205)
Providing and fixing 10 cm PVC nahani trap with grating etc. complete. (SR. No. 1436, SSR No. 42.67, BDV 32, Page No. 205)
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (225 Kilogram) (SR. No. 1437, SSR No. 42.68, BDV, Page No. 205)
Providing and fixing reinforced cement concrete cover of size 90 cm x 45 cm with frame over inspection chamber etc. complete. Medium duty (140 Kilogram) (SR. No. 1438, SSR No. 42.69, BDV, Page No. 205)
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete. Heavy duty (160 Kilogram) (SR. No. 1439, SSR No. 42.70, BDV, Page No. 205)
Providing and fixing reinforced cement concrete cover of size 60 cm x 45 cm with frame over inspection chamber etc. complete.Medium duty (100 Kilogram) (SR. No. 1440, SSR No. 42.71, BDV, Page No. 205)
Providing and making ISI Mark ferrule connection of 15 mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1441, SSR No. 42.72, BDV 4, Page No. 206)
Providing and making ISI Mark ferrule connection of 20 mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1442, SSR No. 42.73, BDV 4, Page No. 206)
Providing and making ISI Mark ferrule connection of 25mm dia.to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1443, SSR No. 42.74, BDV 4, Page No. 206)
Providing and making ISI Mark ferrule connection of 32 mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1444, SSR No. 42.75, BDV 4, Page No. 206)
Providing and making ISI Mark ferrule connection of 40mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1445, SSR No. 42.76, BDV 4, Page No. 206)
Providing and making ISI Mark ferrule connection of 50 mm dia. to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete. (SR. No. 1446, SSR No. 42.77, BDV 4, Page No. 206)
Providing and fixing stainless steel sink of size 600 x 510 x 200 mm incluidng coupling, outlet pipe, elbow and other necessary fitting, finishing etc. complete. (SR. No. 1447, SSR No. 42.78, BDV 4, Page No. 206)
Providing and fixing C.P. Angular stop clock with wall flange of approved make continental including necessary sockets/union nut etc. complete. (SR. No. 1448 SSR No. 42.79, BDV, Page No. 206)
Providing and fixing C.P.Two way BIB cock of approved make continental including necessary sockets/union nut etc. complete. SR. No. 1449 SSR No. 42.80, BDV, Page No. 206)
Providing and fixing C.P. wall mixer with provision for overhead shower with 115mm long bend pipe and wall flange of approved make including necessary sockets/union nut etc. complete. SR. No. 1450 SSR No. 42.81, BDV, Page No. 206)
Providing and fixing C.P. pillar cock long neck with aerator of approed make including necessary sockets/union nut etc. complete. SR. No. 1451 SSR No. 42.82, BDV, Page No. 206)
Providing and fixing C.P. BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete. SR. No. 1452 SSR No. 42.83, BDV, Page No. 206)
Providing and fixing C.P. sink cock with raised J" shaped swinging casted spout ofapproved make including necessary sockets/ union nut etc. complete." SR. No. 1453 SSR No. 42.84, BDV, Page No. 206)
Providing and fixing P.V.C. Rain water pipes of 160mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. SR. No. 1454 SSR No. 42.85, BDV, Page No. 207)
Providing and fixing European type wall-hung white water closet of approved make with push valve concealed type with cover plate 32mm size of approved make including soil pipe, vent pipe up to outside face of wall ,100mm dia. G.I. plug bend inlet pipe all fittings, cuttingand making good walls, floors etc. complete. SR. No. 1455 SSR No. 42.86, BDV, Page No. 207)
Providing and fixing P.V.C. Rain water pipes of 110mm outer diameter and having wall thickness of 2.2 to 2.7 mm confirming to I.S. 13592-1992 including proper rainwater receiving recess with P.V.C. plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25mm to 40mm from face of wall a fixing with clips of approved quality and number ,filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on C.C. or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the P.V.C. fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. SR. No. 1456 SSR No. 42.87, BDV, Page No. 2067)
providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 mm thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg incharge etc complete. (Counter size 1.20 m x 0.60 m ) SR. No. 1457 SSR No. 42.88, BDV, Page No. 207)
stage.html
html • 0.03 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .