Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.2 LAccepted-AOC 7TH MILE UPPER SHILLONG P O NONGLYER SHILLONG 793009 MEGHALAYA | EAST KHASI HILLS | MEGHALAYA | 793009 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹12.0 L+₹1.6 L (14.9%)Rejected-Finance AZARA THAKURIAPARA AZARA ASSAM 781 017 | KAMRUP METRO | ASSAM | 781017 | L2 | Rejected-Finance Being L2 | |
| 3 | L3₹12.3 L+₹1.8 L (17.5%)Rejected-Finance | L3 | Rejected-Finance Being L3 | |
| 4 | L4₹12.3 L+₹1.9 L (18.5%)Rejected-Finance AT ROAD MES TINALI PO CHABUA DISTT DIBRUGARH ASSAM 84 | CHABUA | DIBRUGARH | ASSAM | 786102 | L4 | Rejected-Finance Being L4 | |
| 5 | L5₹12.5 L+₹2.0 L (19.6%)Rejected-Finance AT ROAD NEAR MES TINALI PO CHABUA DIST DIBRUGARH ASSAM | L5 | Rejected-Finance Being L5 |
Tender Value
₹12 L
EMD Value
₹24,000
Closing Date
5 Nov 2019, 6:00 pmClosed
GE (AF) Mohanbari
GE (AF) Mohanbari, Mohanbari-Post, Dibrugarh-Dist, Pin-786012
REPAIR AND MAINTENANCE OF PERIMETER LIGHT, STREET LIGHT AND MISC E/M CONNECTED WORKS AT AF STN MOHANBARI UNDER GE (AF) MOHANBARI
2019_MES_289982_1
NIT No . 8001/168/01/E8 OF 2019-2020
Open Tender
Civil Works
Item Rate
270 days
Air Force Station Mohanbari
As per tender documents
8 documents required · 8 mandatory
₹500
GE (AF) Mohanbari
₹24,000
Yes
8 Jan 2020
15 Oct 2019
9 Nov 2019
15 Oct 2019
5 Nov 2019
30 Oct 2019
Amount
Taking down unserviceable Sodium Vapour/Metal Halide lamp fittings of any watt and any type from existing position on pole/wall/tower checking its serviceability for reuse/repair or replacement of unserieable items such as electronic ignitor,ballast, capacitor, porcelain holder, HPSV/MH lamps of any watts to make it fully functional, internal wiring in all respect complete and keeping unserviceable fittings in safe custody for re-use in the work as directed. Note:- (i) Spares required for repairs and replacement shall be measured and paid seperately under respective item. (ii) Quoted rate shall deemed inclusive of labour element for repair and replacement of spares. (iii) Inventory of all defective parts required to be replaced will be recorded in a separate register alongwith pole No & location / area and type of light fittings before replacement duly signed by JE, Engineer-In-Charge & contractor and the same shall be produced as and when desired for verification.
Supply only Electronic Ignitor of non integral HPSV fittings suitable for of 70 watts to 250 watts complete all as specified.
Supply only Electronic Ignitor SI for Metal Halide fittings of any Watts complete all as specified.
Supply only ballast copper wounded suitable for HPSV/MH fittings 250 watts and conforming to IS : 6616-1982 (Reaffirmed 2006 and Incorporating Ammendment No. 1) complete all as specified.
Supply only ballast copper wounded suitable for HPSV/MH fittings 150 watts and conforming to IS : 6616-1982 (Reaffirmed 2006 and Incorporating Ammendment No. 1) complete all as specified.
Supply only ballast copper wounded suitable for HPSV fittings 70 watts and conforming to IS : 6616-1982 (Reaffirmed 2006 and Incorporating Ammendment No. 1) complete all as specified.
Supply only ballast copper wounded suitable for Metal Halide fittings 150 watts 240 Volts 50 hz complete all as specified.
Supply only ballast copper wounded suitable for Metal Halide fittings 250 watts 240 Volts 50 hz complete all as specified.
Supply only ballast copper wounded suitable for Metal Halide fittings 400 watts 240 Volts 50 hz complete all as specified.
Supply only capacitor suitable for HPSV fittings 150/250 watts complete all as specified.
Supply only porcelain lamp holder screw type suitable for HPSV lamps any watts complete all as specified.
Supply only 250 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply only 150 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply only 70 watt HPSV lamp ISI marked conforming to IS:9974(Pt. 1)/1981 and IS: 9974 (Pt. 2)/1981, tubular shaped outer shell, internally coated with uniform diffusing powder coated, high pressure sodium vapour lamps with GES cap suitable for 200 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply only 250 watt universal burning Metal Halide Lamps ( MH) ,tubular shaped , clear metal halide lamp with ES cap suitable for HPSV ballast with ignitor ,220 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply only 150 watt universal burning Metal Halide Lamps ( MH) ,tubular shaped , clear metal halide lamp with ES cap suitable for HPSV ballast with ignitor ,220 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply only 400 watt universal burning Metal Halide Lamps ( MH) ,tubular shaped , clear metal halide lamp with ES cap suitable for HPSV ballast with ignitor ,220 to 240 Volts, 50 Hz, AC supply complete all as specified.
Supply & fixing in repair loop in loop out Polycarbonate Junction box in accordance with IEC 60670-22 of size 200 mm x 160 mm x 98 mm , suitable for LT cable 10/16/25 sqmm with front openable hinged cover and locking arrangements with IP 65 degree of protection complete with electrical connection fixed to pole with suitable size FI clamp nut bolts and washer including duty painted with powder coated paint complete all as specified and directed.
Cutting/Trimming and removing of tree branches of any girth all around the overhead lines upto 2 metres from the overhead lines and removing the cut branches from worksite outside MD land to any distance.complete all as specified and directed.
Supply and fixed in repairs MCB C-series, four pole of capacity 40 to 63 amps, 240 volts with 10 kA breaking capacity In accordance with IS/IEC 60898-1 including necessary connection complete all specified and directed.
Supply and fixed in repairs MCB C-series, single pole of capacity 6 to 32 amps, 240 volts with 10 kA breaking capacity In accordance with IS/IEC 60898-1 including necessary connection complete all specified and directed.
Supply and fixing in repair Integral metal halide luminaire 250 watt including 250 watt metal halide lamp alonwith channel, MS clamp, nuts, bolts and washers for fixing of MH fitting complete all as specified and directed.
Supply and fixing in repair GI bracket for street light made out of 32 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed.
Supply and fixing in repair GI bracket for street light made out of 25 mm dia GI pipe medium grade 1.5 metre in length bend in shape as required including necessary MS flat iron clamp, nuts and bolts etc complete all as specified and directed.
Material and Labour for drawing two runs of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 2.50 sq mm with one run of PVC insulated unsheathed single core multi stranded copper conductor FR cable of size 1.50 sq mm including 20 mm dia rigid steel conduit stove enameled black welded exclusive of boxes but inclusive of all tees, bends, elbow, reducers etc and fixing accessories such as couples, lock nuts, saddles, pipe hooks, clamps etc complete all as specified
Supply and fixing in repairs Astronomical digital time switch having 24 hours to 7 days time setting with memory location having 6 years battery backup, Two changeover contact and 28 memory location (programmable) complete all as specified. Make : L&T/ C&S Electric/ Legrand/Havells
Supply and fixing in replacement Triple Pole Power Contactor 40 Amps 3 module 3 N/O type of contact conforming to IEC/EN 61095 complete all as specified.
Excavation in trenches not exc 1.5 mtr wide and not exc 1.5 mtr in depth; for trench of cable etc and getting out in Soft/loose soil, making the surface plain complete all as specified and as directed.
Material and labour for sand cushioning for protection of underground cable consolidated and compacted with clean dry sand all as specified and as directed (Compacted thickness shall only be measured and paid).
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm in Soft/loose soil complete all as specified and as directed.
Removing excavated material to a distance n.exc 50 mtr and depositing where directed at level n.exc 1.5 mtr above the starting point all as specified and as directed.
Material and labour for well burnt bricks having crushing strength 75 kg/sqcm best quality locally available laid flat, dry in trenches for cable protection complete all as specified and as directed
Material and labour for galvanized iron tubing 25 mm bore light grade with all fitting for protection of cable, laid in trenches/wall/floor all as specified and as directed. Note: Excavation ,earth work shall be measured and paid separately.
Disconnecting the existing unserviceable LT cable of any size, Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 16 Sqmm 2 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Disconnecting the existing unserviceable LT cable of any size, Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 10 Sqmm 2 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Disconnecting the existing unserviceable LT cable of any size, Supply and fixing/laying XLPE insulated GI wire/strip armoured electric power cable (Heavy duty) with stranded aluminium conductor 1100 volts grade, cross sectional area 25 Sqmm 4 core laid in trench /poles/on wall/floor including nut and bolts, clamps as required at site all as specified and as directed. (Excavation, earth work, sand cushioning, protection brick and pipe shall be measured and paid separately under appropriate items).
Supply and Fixing in repair PVC insulated multi core stranded Copper Conductor cable 4 Sqmm for connection of luminaires all as specified and as directed.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 65 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 90 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed.
Supply and fixing LED street light epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 10200 lumen, system wattage 120 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light complete all as specified and directed.
Supply and fixing for Integrated LED Post Top lantern having Die-cast aluminium graphite grey powder coated spigot housing, spun aluminium graphite grey powder coated finish housing, die-cast aluminium decorative designer top, Opal polycarbonate diffuser, and low powder LEDs connected in series and parallel combination with better heat dissipation arrangement, noiminal voltage 240 Volts, system wattage 45 Watt, not less than 3300 lumen, Ingress protection IP-65 with all acessories including taking down unserviceable light and keep in safe custody for re-use complete all as specified and directed.
Material and labour for CFL lamp 85 Watt, 500 Lumen, minimun 500 average working hours, tri-phosphor coating, high color rendering - 80+ CRI, integrated electronic ballast including taking down unserviceable light and removing from work site complete all as specified and directed.
Supply and fixing for LED Highbay luminare with high efficacy, epoxy powder coated pressure die-cast aluminium housing with weatherproof gasket for LEDs and control gear compartments, pressure die-cast aluminium frame with heat resistant toughened clear glass fixed with SS screws, input voltage 140-280 Volts, delivering lumen equal to/greater than 11200 lumen, system wattage 120 Watt, Ingress protection IP-65 with all acessories including taking down unserviceable light and removing from work site complete all as specified and directed.
Material and labour for painting of erected steel tubular swaged poles of LT over head line ( Except embedded portion), 8.5/9 M long complete including all MS work mounted on pole , earth protection & water pipe ( if exists) with one coat of aluminium paint after necessary preparation and providing 07 Nos bands/ straps with synthetic enamel paint ( any tint 30 cm wide each) from top of plinth block and numbering of poles with white synthetic enamel paint on black ground complete all as specified.
M/s Lalowari Electricals
FREEZCON
M/S R G Construction
M/S RK Trading
M/S N K SAI TRADING
HIND CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .