Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance A 28 SIDCO INDUSTRIAL ESTATE GUINDY GUINDY CHENNAI TAMIL NADU 600032 | CHENNAI | TAMIL NADU | 600032 | Admitted-Finance |
| 2 | Admitted-Finance 2E BERYL BLOOM M MURALI 2E BERYL BLOOM 6 SPARTAN NAGAR ANNA NAGAR WEST EXTN ANNA NAGAR WEST EXTN | Admitted-Finance |
| 3 | Admitted-Finance 47 48 49 MURASOLIMARAN STREET SANTHOSH NAGAR PERUNGUDI CHENNAI TAMIL NADU 600096 | CHENNAI | TAMIL NADU | 600096 | Admitted-Finance |
| 4 | Admitted-Finance 19 NA MC DALAL AND CO PONNAPPA CHETTY STREET VILLAGE TOWN TOWN CITY CHENNAI CHENNAI TAMIL NADU 600003 INDIA | CHENNAI | TAMIL NADU | 600003 | Admitted-Finance |
| 5 | Not Admitted-Fee 12 13 16 VISSVAAS CREST STREET NO 5 TARNAKA SECUNDERABAD RANGAREDDI TELANGANA 500047 | HYDERABAD | TELANGANA | 500047 | Not Admitted-Fee EMD/Instrument is not valid |
Tender Value
Refer Docs
EMD Value
₹5,000
Closing Date
14 May 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
The Director, JIPMER
The Director, JIPMER, Puducherry
Supply of consumables and Non-consumables for the department of Biomedical Engineering Division
2022_JIPMP_683508_1
JIP/PUR.1(10)/OeT/BMED/2022-23
Open Tender
Consumables (Hospital / Lab)
Supply
30 days
JIPMER
Please refer Tender documents.
10 documents required · 10 mandatory
₹590
Payable To The Director, JIPMER, Puducherry
₹5,000
Yes
2 Sept 2022
13 Apr 2022
17 May 2022
13 Apr 2022
14 May 2022
23 Apr 2022
13 Apr 2022 - 18 Apr 2022
730 days
GENERAL CONSUMABLES
Electrical Insulation tape (black color)
Power cord : Power cord should be approved by regulatory body such as IEC/URL/BIS and comply Indian plug Type D/M
Heat shrink sleeve tube : 2mm, 3mm, 5mm diameter (5 Mtr Each Size)
Male and female connectors for NIBP hose to cuff connection compatible for GE 350 Model(Pack Size-One Set)
Male and female connectors for NIBP hose to cuff connection compatible for GE 350 Model(Pack Size-One Set)
Male and female connectors for NIBP hose to cuff connection compatible for Nihon Kodhen Vismo Model. k Size-One Set)
Plug Top 16 Amps
Plug Top 6 Amps
Ventilator (humidifier) consumable - Heater wire adaptor with dual cable compatible for Adult disposable circuit to fit in Fischer and Paykel MR 850 humidifier
Ventilator (humidifier) consumable - Temperature/flow sensor with minimum length of 150cm compatible for Adult disposable circuit to fit in Fischer and Paykel MR 850 humidifier
Ventilator (humidifier) consumable - Heater wire adaptor with dual cable compatible for Adult disposable circuit to fit in Nice Neotech humidifier.
Ventilator (humidifier) consumable Temperature Flow Sensor compatible for Adult disposable circuit to fit in Nice Neotech humidifier.
Ventilator (humidifier) consumable - Heater wire adaptor with dual cable compatible for Infant disposable circuit to fit in GGM humidifier.
Ventilator (humidifier) consumable - Temperature/flow sensor with minimum length of 150cm compatible for Infant disposable circuit to fit in GGM humidifier.
Reusable water traps for adult reusable circuit
Reusable Y connector for adult reusable circuits
Adult Flow sensor for BEL CV200/ Hamilton C3 Ventilator
Infant Flow sensor for Wipro GE Ventilator Model. SLE 5000
Oxygen cell compatible for Wipro GE Ventilator Model. SLE5000
oxygen cell compatible for Maquet ventilator
oxygen cell compatible for Schiller Graphnet ventilator
oxygen cell compatible for Bellavista/Galileo Gold ventilator
oxygen cell compatible for Puritan Bennett PB840 Model
Battery for defibrillator - Rechargeable lead acid battery 10V, 2.5Ah compatible for Zoll M series defibrillator
Battery for defibrillator - Rechargebale 10.8 V lithium ion 5.8AH battery compatible for Zoll M2 Series defibrillator
Battery for defibrillator - Rechargeable Ni-MH battery 12V 2800mAh compatible for Nihon Kodhen TEC 5500 series defibrillator
Battery for Syringe Pump - Rechargeable battery Ni-MH battery 6 V - 1,8 Ah compatible for Fresenius Agilia syringe pump
Battery for Infusion Pump- Rechargeable battery Ni-MH battery 6 V - Ah compatible for Fresenius Model: Optima
Battery for Syringe Pump - Rechargeable Ni-MH battery 8.4V 1.3Ahr compatible for plenumtek Zion plus syringe pump
Battery for Syringe Pump - Rechargeable Lithium battery 11.1V compatible for Comen M200A syringe pump
Reusable 3 lead ECG Cable (Adult) Compatible for SSMed Monitors (Model:Max 66)
Reusable 3 lead ECG Cable (Adult) Compatible for Philips Goldway Monitors
Reusable 3 lead ECG Cable (Infant) Compatible for SSMed Monitors (Model: Max 66)
Reusable 3 lead ECG Cable (Adult) Compatible for Meditech England (Model: Meditech England )
Reusable 3 lead ECG Cable (Infant) Compatible for Meditech England (Model: Meditech England )
Reusable 3 lead ECG Cable Compatible for BPL Monitors (Model: ultima prime)
Reusable 3 lead ECG Cable Compatible for skanray Monitors (Model: Truskan s600 )
Reusable NIBP Hose Compatible for Philips MP Series
Reusable NIBP Hose Compatible for Truskan Monitors
Reusable NIBP Hose Compatible for SS Med Monitor
Reusable NIBP Hose Compatible for Meditech Monitor
Reusable SPO2 Adult Cable compatible for Meditech (MASIMO Compatible type)
Reusable SPO2 (Infant) Cable compatible for Meditech (MASIMO Compatible type)
Reusable SPO2 Cable (Adult) compatible for SS Med Monitor
Reusable SPO2 Cable (Infant) compatible for SS Med Monitor
Reusable SPO2 ( Adult )Cable Compatible for Truskan Monitor
Reusable SPO2 (Adult) Cable Compatible for BPL Monitor
Disposable Bacteria Filter for ICU Ventilator
Adult Breathing Circuit with dual heater wire and Humidification chamber set for ICU Ventilator: Compatible for use with servo controlled heated humidifier with port for temperature and flow sensor for feedback mechanism. The breathing circuit should be disposable and must have 1.5m inspiratory limb with spiral heating coil for uniform tubing. The expiratory limb should be made of moisture diffusing membrane. Must have auto-fill humidification chamber with dual float mechanism. It should be suitable for invasive ventilation, non-invasive ventilation and oxygen therapy.
Infant Breathing Circuit with dual heater wire and Humidification chamber set for ICU Ventilator: Compatible for use with servo controlled heated humidifier with port for temperature and flow sensor for feedback mechanism. The breathing circuit should be disposable and must have 1.5m inspiratory limb with spiral heating coil for uniform tubing. The expiratory limb should be made of moisture diffusing membrane. Must have auto-fill humidification chamber with dual float mechanism. It should be suitable for invasive ventilation, non-invasive ventilation and oxygen therapy.
For the items where "Samples to be shown/provided" is mentioned, the samples should be submitted to the department at the time of quotation submission. The quotation will not be considered if samples are not submitted. For non-consumable items, the brand name should be mentioned for each item. Those quotations without brand name will be rejected. The items should be door-delivered to the Department of Biomedical Engineering Division without any charge (loading'/ Unloading charge, etc.) The expiry date of consumables should not be less than one year after the date of supply. The firm should provide warranty for 1 year for the non-consumable items.
INDIAN MEDICAL SYSTEMS AND TECHNOLOGIES
Lub Dub Medical Technologies Pvt Ltd
M C DALAL AND CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .