Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹23.8 LAccepted-AOC DAULAT NAGAR SOHALLA ROAD AJIJPUR DHANOLI AGRA UP PIN 282001 | AGRA | UTTAR PRADESH | 282001 | 1 | Accepted-AOC Due to L-1 and credit | |
| 2 | 2₹26.0 L+₹2.1 L (8.79%)Rejected-Finance | 2 | Rejected-Finance Being other than L-1 |
Tender Value
₹27 L
EMD Value
₹54,000
Closing Date
30 Dec 2024, 6:00 pmClosed
GE (AF) ADM AREA AGRA
GE (AF) Adm Area Agra UP 282008
WORKS SERVICES FOR SETTING UP OF SOLID WASTE MANAGEMENT UNDER AGE BR-II OF GE(AF) ADM AREA AT AF STN AGRA.
2024_MES_686079_1
8000-2202/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) ADM AREA AGRA
Please refer Tender documents.
4 documents required · 4 mandatory
₹500
GE (AF) ADM AREA AGRA
₹54,000
Yes
1 Feb 2025
28 Nov 2024
1 Jan 2025
28 Nov 2024
30 Dec 2024
12 Dec 2024
Amount
Dismantling asbestos cement (corrugated/semi corrugated etc) sheets in roof coverings complete all as specified and directed.
Dismantling structural steel work as in purlin, rafters & similar works complete all as specified and directed.
Taking down roof trusses(wooden), coupled rafters or trussed beams, above 8 metres & upto 12 metres complete all as specified and directed.
Surface excavation not exc 30 cm deep and averaging 15 cm deep and getting out in hard /dense soil complete all as specified and directed.
Excavating in post holes (or similar holes) each not exceeding 0.5 cum , getting out, returning, filling in and ramming earth or brocken rubble mixed with earth around in layers not exceeding 25 cm , watering and removing surplus soil to a distance not exc 50 M and making good surface , in hard dense soil complete all as specified and directed.
Excavation in trenches not exc.1.5 Mtr in width and not exceeding 1.5 Mtr in depth for foundation / laying of cable etc and getting out in hard/dense soil etc complete all as specified and directed.
M&L for cement concrete in foundation, filling and mass concrete type D2 1:4:8 (using 40 mm graded stone aggregates) complete all as specified and directed.
M&L for mild steel TMT bars 10mm dia and over cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire annealed not less then 0.9 mm dia for securing with clips complete all as specified and directed.
All as per item No-08 above but 5 mm dia and over upto and including 10 mm dia in strripus, spaces and binders
M&L formwork to sides of concrete foundations, foottings, bases of columns and plinth beams and similar works for rough finished surfaces of concrete flat complete all as specified and directed.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate) as in foundations,footings, plinth beams, bases for colums etc. complete all as specified and directed.
M&L formwork to sides of pillers, posts, columns etc rough finished surface of concrete Squre or rectagularcomplete all as specified and directed.
M&L RCC M-25 Design Mix (using 20mm graded stone aggregate ) as in columns pillers,piers,posts and struts complete all as specified and directed.
M&L for fly ash brick work using subclass-B, bricks straight or curved on plan, exc 6m mean radius built in CM 1:6 complete all as specified and directed.
S&F rolled mild steel section of grade Fe 410 (Gde E-250) quality -A as in framed roof trusses and similar works fixed with and incl. angle cleats or other connecting plates complete all as specified and directed.
S&F mild steel rolled section of grade Fe 410 (Gde E-250) quality- A as in main and cross beams hip and jack rafters; purlins where connected tocommon rafter and running rails ; and similar works fixed with and incl. angle cleats or other connecting plates complete all as specified and directed.
All as per item No-16 above but fixing only Remarks. Old serviceable structural members, retreived from item No. 2 shall be used in this item.
S & F 0.50 mm thick pre painted Galvalume aluminium zinc coating GI based corrugated steel sheet of an having.colour on exterior side tensile strength of 550MPA as in roof covering/cladding to walls fied with self tapping screws complete all as specified and directed.
All as per itm No18 above but plain sheet as in ridges
Returning, filling in including spreading, levelling, watering and well ramming in layer not exceeding 25 cm thick using soil complete all as specified and directed.
Spreading of earth and leveling in layers n.exc 25 cm thick including well ramming as required complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and directed.
M&L for hard core guage n. exc. 63mm of broken stone deposited spread and levelled in layers n. exc. 15cm thick watered and rammed to a true surface complete all as specified and directed.
M&L cement concrete 1:4:8 type D-2 (using 40 mm graded stone aggt) as in sub base of floor (75 mm thick) complete all as specified and directed.
M&L 75 mm thick cement concrete 1:2:4 type B-1 (using 20 mm graded stone aggt) as in floor, finished even & smooth without using extra cement complete all as specified and directed.
Roughening surfaces of old concrete floor by picking,sweeping, clean and washing down with water to remove dust ets and brushing neat cement slurry with 3 kg of cement per sqm complete all as specified and directed.
M&L for 50 mm thick plain cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in floor finished even and fair complete all as specified and directed.
M&L for PCC 1:3:6 type C2 (using 40mm graded stone aggrigate) 75mm thick as in plinth projection/hard standings, finished even and rough to receive the top layer complete all as specified and directed.
Taking down cement plaster on brick or stone walls etc including raking out joints, hacking for key scrubbing down with water etc. complete all as specified and directed.
M&L rendering 15mm on fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L rendering 15mm on other than fair faces of brick work in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying three coats of white wash on walls complete all as specified and directed.
M&L for preparation of old plastered wall surfaces and applying two coat of white wash on walls complete all as specified and directed.
M&L for preparation of new plastered wall surfaces and applying two coats of weather coat exterior paint of required shade, over & including primer coat of exterior primer, all as per manufacturer's specification complete all as specified and directed.
M&L for preparation of old plastered wall surfaces and applying two coats of weather coat exterior paint of required shade, over & including primer coat of exterior primer, all as per manufacturer's specification complete all as specified and directed.
S&F Mild steel framed work conforming to Gde-E-250 quality ‘A’ as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. doors, etc. to be prepared for hanging complete all as specified and directed.
S&F Mild steel, plain, 1.25mm thick, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivet steel framing with plain 40mm lap joints with riveted or welded seams, complete all as specified and directed.
M&L two coat of synthentic enamel paint on new/old steel surface including preparation over 10cm width or girth over one coat of primer complete all as specified and directed.
M&L for PCC 1:4:8 type D2 concrete bed to drain pipe including packing under and haunching against the sides of pipe of 150mm bore after they are laid and tested complete all as specified and directed.
M&L SGSW pipe 150mm bore laid in trenches jointed in cement mortar 1:1 and jointed complete all as specified and directed.
M&L for rendering 15mm thick plaster on concrete surface in CM 1:4 using WPC @ 3% by weight of cement and finishing surface even and smooth without using extra cement including integral waterproofing compound as per manufacturer instruction complete all as specified and directed.
M&L type B1 1:2:4 (20mm graded stone aggregate) providing RCC precast cement concrete as in cover slab for man hole and similar article with plain face. Set in cement mortar 1:4 complete all as specified and directed.
M&L for PCC 1:2:4 type B0 as in benching including weathering slightly rounded or chanferred angle and throating complete all as specified and directed.
S&F 100 mm bore UPVC pipe complete to walls ceiling or infloors etc. complete all as specified and directed.
M&L for construction of septic tank designed to carry sewage and sludge water, including excavation in any type of soil, PCC 1:4:8 below foundation, brick walls, baffle walls and roof slab including vent shaft, manhole openings and cover connections etc complete with effective depth 1.50m and over all depth 3.00 m for 30 user's complete all as specified and shown on Drg No. TD-217 sheet 1/2 & 2/2 and as directed.
M&L for construction of soakage well including excavation in any type of soil, foundation in PCC 1:3:6 wall of honey combed masonry with top ring of M-25 concrete including intercepting chamber and screen chamber, made of brick masonry in CM (1:4). RCC cover slab in M-25/SFRC cover, interconnecting pipes of RCC/DWC filled with brick bats of size 3.0 m dia x 3.0 m deep. complete all as specified & shown in Drg No. TD-576 sheet No 1/2 & 2/2 and directed.
M & L for point wiring for light/fan controlled by one switch with 1.5 sqmm single core 1100V grade FRLSH PVC insulated unsheathed multistranded copper conductor with and including PVC concealed conduit of medium grade with all fittings including MS pressed steel shet (1.6mm thick) sunk box with 3mm thick ISI marked laminated bakellite sheet fixed with cromium / nicckel plated screws and washers for switches and sockets, including 1.5 sqmm single core 1100v grade FRLSH PVC insulated unsheathed multistranded copper conductor as earth continuity conductor connected to common earth dolly and including cutting chases in walls / floors for concealed conduiting and making good disturbed surface area and white wash/colour wash to matching with the existing colour complete all as specified and directed.
All as per srl item No 47 above but for 3 pin 5 amps socket outlet on the same board with other switch complete all as specified and directed.
All as per srl item No 47 above but for one 3 pin socket outlet 15 amps socket on independent board with 2.5 sqmm cable and 2.5 sqmm cable as earth continuity conductor.. Note: (a) colour coding is to be maintained .(Ph-Red, N-Black,Earth- Green)
All as per srl item No 47 above but for wiring with 4.00 Sqmm for 15 Amps switch socket combination on ndependent board/two pin earth plug and socket including 4 Sqmm PVC insulated multi stranded unsheathed copper earth continuity conductor and connected to common earth dolly.
S&F switch piano flush type one way 5 amps SP 240 volts complete all as specified and directed.
S&F switch piano flush type one way 16 amps SP 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 5 pin 5/6 amps flush type 240 volts complete all as specified and directed.
S&F socket outlet 2 in 1, 6 pin, 5 and 15 amps flush type 230 volts complete all as specified and directed.
S&F ceiling rose 65 x 50mm three terminals complete all as specified and directed.
S&F ceiling fan regulator, electronic stepped type 5 stage speed regulation, ISI marked complete all as specified and directed.
S&F in replacement existing U/S light fitting with energy saving decorative LED batten 20 watt (4 Feet), 230 voltas, energy efficient tube light fitting extruded aluminium housing provided for efficient heat dissipation with polycarbonate diffusre & integrated electronic driver complete with all accessories prewired and includeing making connections with 3 core twisted flexible copper cable of size 23/.0076 from ceilling rose/PVC connector to light fittings complete all as specified and directed. Note:- Power factor should not be less thtn 0.95 Make- Halonix- , ORIENT Cat part No-LBLN-20-C-AL /BAJAJ-BCLAB 20W LED P/HALONIX- HLB-03-20-CW-AL-SQ
Supply and Fixing BLDC 5 Star ceiling fan 1200mm sweep with remote suitable to work on single phase AC 230 volts 50Hz complete with connecting electrically to ceiling rose or connector black using PVC insulated and over all sheathed 3 core cable of size 0.75 Sqmm with flexible copper conductor complete all as specified and directed. Make -BAJAJ- ENERGOS 26 BEE 5 Star or equivelent to Havells/Crompton
Supply and fixing hevy duty exhaust fan 300 mm sweep, 1400 rpm, steel body, AC, Single phase, 230 volts complete with louvers shutters and including PVC insulated three core 1.5 sqmm copper cable from ceiling rose to exhaust fan complete all as specified and directed.
S&F sheet metal enclosures distribution boards, double door three phase 415 volts 8 ways vertical TPN DB for comprising three phase four wire 300 Amp rated copper strip bus bar of appropriate capacity complete all as specified and directed and comprising of the following :- (a) MCCB four pole 200Amps AC 415 Volts 25 KA - 01 No. as incoming (b) 24 Nos. MCB SP 40 Amps, C curve rupturing capacity 10 KA as outgoing Note :- (i) The DB shall be flush fixed and making good the disturbed surface matching with existing specifications. (ii) All connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin /bottle type thimble -properly crimped. (iii) All vacant holes of the DB shall be provided with blank plates of appropriate size. (iv) Double continuous earth wire shall be provided for each three phase DB from earthing mains dolly (v) MCB's should have a same make as of DB.
S & F MCB single pole 240 volts, 'C' curv of rating from 6 to 32 amps, with rupturing capacity 10 KA,including providing thimble for out going cables complete all as specified and directed.
S & F sheet metal single pole and neutral enclosure with socket, plug top complete with one single pole MCB of 20 Amps, 240 volts complete all as specified and directed.
Supply and Fix MCCB TPN, 100 Amps, 415 Volts, 16 KA , 'C' Series including removing of unserviceable complete all as specified and directed.
Supply & Fix sheet metal enclouser suitable for 100 Amps MCCB 4 pole and making good to the disturbed surfaces of wall complete all as specified and directed.
S&F sub main wiring with 4 run of 10 Sqmm single core PVC insulated unsheathed cable 1100 Volts grade multistranded with copper conductor (FRLS) drawn through and including non metallic rigid PVC conduit 20 mm dia including conduit accessories concealed/surface type on walls, roof, floors etc including two run of 10 Sqmm PVC copper conductor as earth continuity wire including taking down unserviceable sub main wiring and conduit complete all as specified and directed. Note :- 4 Runs of 10 sqmm cable 2 run of 10 sqmm cable and 1 run of PVC conduit shall measured as one unit for the purpose of payment.
S&F of PVC insulated copper conductor 4 core flexible cable of size 35 Sqmm laying of waal/floor including fixing arrangement and its connection complete all as specified and directed.
S&F for supply, fixing and laying GI water tubing 25 mm bore medium grade ISI marked with all required fittings such as bends, elbow, tees, short pieces, connector, check nuts and threading complete all as specified and directed.
S&F for Gun metal gate valve ISI marked with iron wheet head screwed both ends for pipe of size 25 mm complete all as specified and directed.
M&L earthing complete and providing new earthing with galvanised steel earth plate electrode, 600 x600 x 6mm thick burried directly in the ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5mtr below ground level connected to galvanised iron wire 4mm dia as earth lead by means of bolts, nuts and washers of GI up to test point, GI tubing 15 mm bore medium grade protection pipe, GI watering pipe 20mm bore light grade with funnel and wire mesh, charcoal, salt complete all as per SSR with PCC chamber, 50mm thick RCC cover in 1:2:4 type B-1 using 20mm graded stone aggregate reinforced with 8mm dia TMT bar @ 80mm c/c both way including earth work in any type of soil , removal of surplus soil to a distance n.exc 50 m and connecting, testing on completion all as shown on electric plate No 03 of SSR -2009 Part I complete all as specified and directed.(Note: Excavation and earth work is deemed to be included in the rates quoted).
S&F XLPE insulated armoured heavy duty electric cables with aluminium conductor, 1100 volts grade cross sectional area 70 Sqmm 3.5 core complete all as specified and directed.
Supply and laying in replacement of brick, double walled corrugated (DWC) HDPE duct pipe conforming to IS 16205 Pt -24 of approved color complete with fittings for cable protection of size 63 mm outer dia and 50 mm inner dia complete all as specified and directed.
saroj constructions (BID ID -3189545)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .